HU1060 - Humidifier SOLAC - Free user manual and instructions
Find the device manual for free HU1060 SOLAC in PDF.
| Product type | Ultrasonic humidifier |
| Brand | SOLAC |
| Model | HU1060 |
| Technology | Ultrasonic for fine water particles |
| Water tank | Removable with lid and handle |
| Filters | Antibacterial filter and ion exchange resins |
| Steam flow regulator | Yes, adjustable |
| Indicator lights | Power indicator and empty tank indicator |
| Recommended placement area | Flat, stable surface, 50 cm - 1 m above the floor |
| Recommended relative humidity | 40 to 60% |
| Transducer maintenance | Weekly cleaning with vinegar using a cotton swab |
| Tank cleaning | Weekly with water and a few drops of bleach or disinfectant |
| Usage precautions | Do not use with empty tank, do not tilt, do not place near furniture or electronic devices |
| Power supply | Check voltage on the rating plate |
| Medical indications | Suitable for colds and laryngitis; not recommended for bronchial asthma and allergies |
Frequently Asked Questions - HU1060 SOLAC
User questions about HU1060 SOLAC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Humidifier in PDF format for free! Find your manual HU1060 - SOLAC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HU1060 by SOLAC.
USER MANUAL HU1060 SOLAC
natural_image
Line drawing of a Bollac air purifier device with control panel and buttons (no text or symbols)Solac is a registered Trade Mark
11/08
5-9 • ESPAÑOL
10-13 • ENGLISH
14-18 • FRANÇAIS
19-22 • DEUTSCH
23-26 • PORTUGUÊS
27-30 • ITALIANO
31-34 • NEDERLANDS
35-38 • ČESKY
39-42 • POLSKI
43-46 • SLOVENČINA
47-51 • MAGYAR
52-56 • българск
57-60 • HRVATSKA
61-64 • ROMÂNĂ
es
en
fr
de
pt
it
nl
CS
pl
sk
hu
bg
hr
ro



natural_image
Illustration of a hand holding a mechanical device with a rotating arrow and a warning icon (no text or symbols)Fig. 1
ESPAÑOL
es
1 ATENCIÓN
- Read the instructions carefully before using the product. Keep the instructions for future reference.
- Children should be supervised to ensure that they do not play with the appliance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety.
- Remove all elements from the inside or outside of the appliance used for protection during transport or for sales promotions, such as paper or plastic bags, plastic sheets, cardboard and stickers.
- Do not plug in the appliance without first checking that your home mains voltage matches that stated on the specifications plate.
- Do not cover the appliance while in use.
- Place on a flat, firm shelf about 0.5 m or 1 m from the floor. Never use on the floor. Never tip.
- Do not place the mist outlet near any furniture, the wall, a TV or any other appliance that can be damaged by damp. Water can condense around the appliance when the air in the room is not capable of absorbing the flow of mist produced by the humidifier.
- Use only for the purposes indicated. The manufacturer is not liable for damage caused by unsuitable or incorrect use of the humidifier.
- Do not use the humidifier if the connection cable is damaged or the appliance is faulty. Certain operations, such as replacing the power cord, will have to be done at an authorized service centre, as special tools are needed.
- If the humidifier is not to be used, unplug it from the mains.
- The unit must be unplugged for assembly, cleaning, removal or filling with water.
- Always fill the tank with clean water. Do not add detergent, freshener or essence. NEVER POUR WATER IN THE VAPORISATION CHAMBER.
- Never remove the water tank with the appliance working.








- Do not use the appliance if the water tank is empty.
- Do not expose to direct sunlight or place near heat sources.
- Ensure that the water tank cover is completely closed.
- Ensure that the appliance is unplugged before removing the water tank.
- Do not touch the ultrasound transmitter with your hands or with tools.
- Do not use the humidifier when barefoot. Do not touch the appliance with wet hands when in operation.
- When unplugging the appliance, do not pull on the power cord or the appliance.
- Never leave the appliance outdoors exposed to the elements.
- The appliance and its power cable must not be placed under water in any case.
- Do not fill it with hot water.

WARNING!!: When you want to dispose of the appliance, NEVER throw it in the bin. Take it to your nearest RECYCLING POINT or waste collection centre for treatment. You will thus be helping to take care of the environment.
2 MAIN COMPONENTS
1 On/off switch
2 Water tank
3 Tank cover
4 Tank handle
5 Steam outlet
6 Base
7 Ion exchange resins
8 Transducer
9 Steam flow regulator
10 Anti-bacteria filter
11 Interior water tank
12 Empty tank indicator light
13 "On" indicator light
3 OPERATION AND USE
1 Remove the water tank (2) from the base (6), turn it over, and remove the cover from the bottom part (3) by turning it counter-clockwise. Fig.1. Add cold tap water without filling it completely, otherwise the ion
exchange resins could cause the water to spill over the top when the cover is put on.
2 Put the cover back on by aligning the marks on the tank with the grooves on the cover, and turn it clockwise. Be sure that it is closed firmly.
3 Turn the tank back over, and place it on the base while making sure that it is seated correctly.
4 When placing the water tank (2) back on the base, part of the water that it contains will transfer to the space existing between the tank and the body (11). This is how the device works normally and poses no hazard.
5 Plug in the humidifier, and turn it on using the on/off switch (1). The "on" indicator light will come on.
6 Select the desired steam flow rate using the steam flow regulator (9).
7 If condensation is observed close to the humidifier, select a lower steam flow rate.
8 When you want to stop the steam flow, select the "off" position using the on/off switch (1).
9 If there is insufficient water in the tank, the "empty tank indicator light" (12) will come on, and steam generation will be stopped. In this case, it will be necessary to turn off the humidifier and refill the tank with water before turning the device back on.
While the humidifier is operating, the water used will be filtered through an anti-bacteria filter (10) located in the base, thus preventing impurities from being emitted into the atmosphere.
4 MAINTENANCE AND CLEANING
▲ Before any cleaning operation, switch the appliance off and unplug it.
1 There may be some scale deposits in the transducer, particularly in areas with hard water. Overcome this drawback by cleaning the transducer with vinegar at least once a week, as follows:
a) Moisten a cotton bud with vinegar and wipe the transducer gently, until the scale deposits disappear completely.
b) Rub down with a dry cloth and remove remains of moisture.
c) Do not rub the transducer with solid objects.
d) Do not clean with chemical products.
2 Clean the inside of the water tank at least once a week, as follows:
a) Fill the tank with clean water adding a few drops of bleach or a similar disinfectant. Close the tank completely with its cap and shake forcibly.
b) Rinse thoroughly.
i Note: Water accumulated over long periods may create bacteria and mildew (fungus).
3 The outside of the appliance can be cleaned using a soft damp cloth.
4 Store the appliance in a cool, dry place.
5 Do not place the transducer directly under the tap.
Water must not get into the appliance; should this happen, take it to an authorised service centre before using it again.
5 OBSERVATIONS
Humidifiers using ultrasound technology produce smaller water particles which can more easily reach the lower respiratory tracts.
This type of humidifier is therefore suitable for the treatment of symptoms of the common cold and laryngitis.
Their use is not however recommended for persons with bronchial asthma and allergies.
- Domestic humidifiers are ideal for obtaining a comfortable humidity environment between 40% and 60%, the range in which the risk of respiratory infection is minimised.