HU1050 - Humidifier SOLAC - Free user manual and instructions
Find the device manual for free HU1050 SOLAC in PDF.
| Product type | Ultrasonic humidifier |
| Brand | SOLAC |
| Model | HU1050 |
| Technology | Ultrasonic |
| Main functions | Humidification and ionization |
| Tank capacity | 2.5 L (estimated) |
| Vapor flow rate | 200-300 ml/h (estimated) |
| Recommended area | 20-30 m² (estimated) |
| Power supply | 220-240 V, 50/60 Hz |
| Power consumption | 30 W (estimated) |
| Dimensions (L x W x H) | 22 x 22 x 30 cm (estimated) |
| Net weight | 1.5 kg (estimated) |
| Noise level | < 35 dB (estimated) |
| Automatic shut-off | Yes, by water level detection |
| Ionization | Yes, emission of negative ions |
| Maintenance | Weekly cleaning of the transducer with vinegar |
| Water level indicator | Yes, indicator light |
| Cleaning brush included | Yes |
| Safety | Automatic disconnection of the transducer in case of water shortage |
Frequently Asked Questions - HU1050 SOLAC
User questions about HU1050 SOLAC
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Humidifier in PDF format for free! Find your manual HU1050 - SOLAC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HU1050 by SOLAC.
USER MANUAL HU1050 SOLAC
natural_image
Black and white photo of a baby blender with 'sOla' branding and cloud motif (no readable text or symbols beyond branding)Solac is a registered Trade Mark
09/07
5-9 • ESPAÑOL
10-14 • ENGLISH
15-19 • FRANÇAIS
20-24 • DEUTSCH
25-29 • PORTUGUÊS
30-34 • ITALIANO
35-39 • NEDERLANDS
40-44 • ČESKY
45-49 • POLSKI
50-54 • SLOVENČINA
55-60 • MAGYAR
61-66 • българск
67-71 • HRVATSKA
72-76 • ROMÂNĂ
es
en
fr
de
pt
it
nl
CS
pl
sk
hu
bg
hr
ro






























































































































































ESPAÑOL
es
1 ATENCIÓN
- Read the instructions carefully before using the product. Keep the instructions for future reference.
- Keep the appliance out of the reach of children.
- Remove all elements from the inside or outside of the appliance used for protection during transport or for sales promotions, such as paper or plastic bags, plastic sheets, cardboard and stickers.
- Do not plug in the appliance without first checking that your home mains voltage matches that stated on the specifications plate.
- Do not cover the appliance while in use.
- Place on a flat, firm shelf about 0.5 m or 1 m from the floor. Never use on the floor. Never tip.
- Do not place the mist outlet near any furniture, the wall, a TV or any other appliance that can be damaged by damp. Water can condense around the appliance when the air in the room is not capable of absorbing the flow of mist produced by the humidifier.
- Use only for the purposes indicated. The manufacturer is not liable for damage caused by unsuitable or incorrect use of the humidifier.
- Do not use the humidifier if the connection cable is damaged or the appliance is faulty. Certain operations, such as replacing the power cord, will have to be done at an authorized service centre, as special tools are needed.
- If the humidifier is not to be used, unplug it from the mains.
- The unit must be unplugged for assembly, cleaning, removal or filling with water.
- Always fill the tank with clean water. Do not add detergent, freshener or essence. NEVER POUR WATER IN THE VAPORISATION CHAMBER.
• Never remove the water tank with the appliance working. - Do not use the appliance if the water tank is empty.
- Do not expose to direct sunlight or place near heat sources.
- Ensure that the water tank cover is completely closed.
-
Ensure that the appliance is unplugged before removing the water tank.
-
Do not touch the ultrasound transmitter with your hands or with tools.
- Do not use the humidifier when barefoot. Do not touch the appliance with wet hands when in operation.
- When unplugging the appliance, do not pull on the power cord or the appliance.
- Never leave the appliance outdoors exposed to the elements.
- The appliance and its power cable must not be placed under water in any case.
- Do not fill it with hot water.

WARNING!!: When you want to dispose of the appliance, NEVER throw it in the bin. Take it to your nearest RECYCLING POINT or waste collection centre for treatment. You will thus be helping to take care of the environment.
en
2 MAIN COMPONENTS
1 Water tank
2 Mist outlet
3 Ioniser function on/off switch
4 Pilot light
5 Mist on/off switch
6 Ionised air outlet
7 Pilot light showing that the ioniser function is active
8 Water level float
9 Transducer
10 Internal water tank
11 Brush
3 OPERATION AND USE
1 Separate the water tank (1) from the base, turn it over and remove the cap from the bottom, turning it anticlockwise. Fig.1. Fill with cold water; do not fill completely.
2 Replace the plug, aligning the notches on the tank with the grooves on the cap, and turn it clockwise. Make sure it is well closed.
3 Turn the tank over and place it on its base making sure it fits perfectly.
4 When placing the water tank (1) back on the base, a part of the water it contains enters the space between the tank and the body (10); this is part of the normal operation of the appliance and does not entail any risk.
5 Plug the adapter into the mains socket. Use the on / off switch (5) to select the desired flow of mist. Fig. 2. The humidifier starts working and the pilot light (4) comes on.
6 When you want to deactivate the mist function, use the on/off switch (5) and return it to the original position.
The humidifier has a safety system that disconnects the transducer (9) before running dry, thanks to its water level float (8).
The ioniser function can be selected on its own or simultaneously with the emission of mist. It causes the appliance to emit negative oxygen ions, providing healthier, fresher air in the room. If the mist function is not required, the product can still be used as an air purifier.
- To use the ioniser function, press the on / off switch (3) Fig. 3. The pilot light (7) remains on while the ioniser function is active. To deactivate this function, press the selector again (3) and the pilot light (7) goes out.
4 MAINTENANCE AND CLEANING
▲ Before any cleaning operation, switch the appliance off and unplug it.
1 There may be some scale deposits in the transducer, particularly in areas with hard water. Overcome this drawback by cleaning the transducer with vinegar at least once a week, as follows:
a) Moisten a cotton bud with vinegar and wipe the transducer gently, until the scale deposits disappear completely.
b) Rub down with a dry cloth and remove remains of moisture.
c) Do not rub the transducer with solid objects.
d) Do not clean with chemical products.
2 Clean the inside of the water tank at least once a week, as follows:
a) Fill the tank with clean water adding a few drops of bleach or a similar disinfectant. Close the tank completely with its cap and shake forcibly.
b) Rinse thoroughly.
Note: Water accumulated over long periods may create bacteria and mildew (fungus).
3 The outside of the appliance can be cleaned using a soft damp cloth.
4 Store the appliance in a cool, dry place.
5 With each change of water the included brush (11) should be used to remove dust and any scale remains on the transducer.
6 Do not place the transducer directly under the tap.







Water must not get into the appliance; should this happen, take it to an authorised service centre before using it again.
5 TROUBLESHOOTING
| PROBLEM | POSSIBLE CAUSE | SUGGESTION |
| The appliance is not receiving power | The humidifier is not connected to the mains. | Plug the appliance into the mains. |
| The power socket is not receiving power. | Check the fuses and whether or not the socket is receiving power. | |
| No mist comes out | The water tank is empty (1). | Fill the water tank. |
| The fan is broken. | Call the authorised technical service. | |
| Some other component of the appliance is broken. | Call the authorised technical service. | |
| No mist comes out but the water tank is full. | The selected moisture output level is too low. | Select a higher moisture output level. |
| The appliance is not placed on a flat surface. | Place the appliance on a flat surface. | |
| There are scale deposits on the transducer. | Clean the transducer using the included brush and fill the tank | |
| Detergent was used to clean the tank. | Rinse the tank with clean water. | |
| The transducer is broken. | Call the authorised technical service. | |
| Scale deposits | Hard water with high mineral content | Use distilled water. |
| Bad smell | Water in the tank for too long. | Clean the tank with water and vinegar and rinse with clean water. |
| Leave the tank open for some time without the cap, in a cool place. |
6 OBSERVATIONS
Humidifiers using ultrasound technology produce smaller water particles which can more easily reach the lower respiratory tracts.
This type of humidifier is therefore suitable for the treatment of symptoms of the common cold and laryngitis.
Their use is not however recommended for persons with bronchial asthma and allergies.
- Domestic humidifiers are ideal for obtaining a comfortable humidity environment between 40% and 60%, the range in which the risk of respiratory infection is minimised.
FRANÇAIS
fr