Top Class Island IXBL/A/120 - Range hood ELICA - Free user manual and instructions

Find the device manual for free Top Class Island IXBL/A/120 ELICA in PDF.

ELICA Top Class Island IXBL/A/120 - Range hood
📄 280 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice ELICA Top Class Island IXBL/A/120 - page 18
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Island hood
Brand Elica
Model Top Class Island IXBL/A/120
Dimensions (L x D x H) 120 cm x 70 cm x 50-110 cm (adjustable height)
Weight Approx. 25 kg
Power supply 220-240 V / 50-60 Hz
Suction power Up to 650 m³/h
Maximum noise level 65 dB(A)
Energy class A+ (according to EU standard)
Lighting Integrated LED, adjustable intensity
Controls Touch panel with 4 speeds + boost mode
Filters Stainless steel grease filter (dishwasher-safe) + charcoal filter (optional)
Special functions Timer, automatic shut-off, filter saturation indicator
Material Brushed stainless steel and tempered glass
Installation Central island or wall-mounted
Connection diameter 150 mm (external evacuation)
Maintenance and cleaning Clean metal filters every 2 months; replace charcoal filter every 3-6 months
Safety Automatic shut-off in case of overheating, CE compliance
Spare parts and repairability Available via Elica after-sales service; replacement charcoal filter, LED bulbs, control panel
General information 2-year warranty; made in Italy

Frequently Asked Questions - Top Class Island IXBL/A/120 ELICA

How to install the Elica Top Class Island IXBL/A/120 hood?
Installation should be carried out by a professional. Fix the hood to the ceiling using the supplied bracket, connect to the exhaust (if in extraction mode) and plug in the power. Refer to the manual for precise dimensions.
What is the ideal height between the hood and the cooking surface?
For electric cooking, install the hood 65-75 cm above the hob; for gas cooking, 75-85 cm.
How to clean the grease filters?
The metal filters are dishwasher safe at 60°C. Use a mild detergent. Dry them before reinstalling.
When should the charcoal filter be replaced?
The charcoal filter must be replaced every 3 to 6 months depending on usage, or when the saturation indicator lights up.
Can the hood work in recirculation mode?
Yes, in recirculation mode with an active charcoal filter (sold separately). The air is cleaned and returned to the kitchen.
How to adjust the suction speed?
Use the touch panel to choose among 4 speeds. The boost mode provides temporary maximum suction.
Why is the hood making noise?
Normal noise may come from the motor or vibrations. Check that the hood is properly fixed and the filters are clean. A noise level up to 65 dB is acceptable.
What to do if the LED lights do not turn on?
Check the power supply. If the problem persists, contact after-sales service to replace the LED module.
How to reset the filter saturation indicator?
After cleaning or replacement, press and hold the indicator button for 3 seconds until the light turns off.
Where to find spare parts?
Parts are available from Elica customer service or authorized dealers. Use original parts for warranty.

User questions about Top Class Island IXBL/A/120 ELICA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Range hood in PDF format for free! Find your manual Top Class Island IXBL/A/120 - ELICA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Top Class Island IXBL/A/120 by ELICA.

USER MANUAL Top Class Island IXBL/A/120 ELICA

EN - Instruction on mounting and use

H 5

5 ΔH (cm) = (X - Y - M) + 10.5

16 x Ø 3.5x9.5mm 6

FRONT SX RX H - 11cm 7

Diagram illustrating a mechanical device with labeled parts and directional arrows, including a magnified inset showing a device with a coil.

Technical diagram illustrating a mechanical assembly with labeled components and directional arrows, including a magnified inset showing cross-sectional views.

Technical diagram showing mechanical assembly with labeled components and directional arrows indicating motion or movement.

11

16 x Ø 3.5x9.5mm 12

13 x 4

14 x 2

Ø 150 mm x 1 15

Ø 120÷125 mm * * *

6 x Ø 3.5x9.5mm 16

8 x Ø 3.5x9.5mm 17 H Min

18 x 8 x 4 x 4

19

220-240 V ~ 50-60 Hz 8 x Ø M4x7mm 20

21 2 x Ø 3x9mm

22 x 6 x 6

23

6 x Ø M4x7mm 24

25

26

2 x Ø 3x9mm 27

28.1 28.3 28

28.4

29

30

31

EN - Instruction on mounting and use

Closely follow the instructions set out in this manual. All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. The hood is conceived for the suction of cooking fumes and steam and is destined only for domestic use.

The hood can look different to that illustrated in the drawings in this booklet. The instructions for use, maintenance and installation, however, remain the same.

! It is important to conserve this booklet for consultation at any moment. In the case of sale, cession or move, make sure it is together with the product. ! Read the instructions carefully: there is important information about installation, use and safety. ! Do not carry out electrical or mechanical variations on the product or on the discharge conduits. ! Before proceeding with the installation of the appliance verify that there are no damaged all components. Otherwise contact your dealer and do not proceed with the installation.

Note: the elements marked with the symbol “(*)” are optional accessories supplied only with some models or elements to purchase, not supplied.

Caution

Before any cleaning or maintenance operation, disconnect hood from the mains by removing the plug or disconnecting the mains electrical supply. Always wear work gloves for all installation and maintenance operations.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.

Children shall not be allowed to tamper with the controls or play with the appliance.

Cleaning and user maintenance shall not be made by children without supervision.

The premises where the appliance is installed must be sufficiently ventilated, when the kitchen hood is used together with other gas combustion devices or other fuels.

The hood must be regularly cleaned on both the inside and outside (AT LEAST ONCE A MONTH).

This must be completed in accordance with the maintenance instructions provided in this manual. Failure to follow the instructions provided in this user guide regarding the cleaning of the hood and filters will lead to the risk of fires.

The flaming of foods beneath the hood itself is severely prohibited.

The use of exposed flames is detrimental to the filters and may cause a fire risk, and must therefore be avoided in all circumstances.

Any frying must be done with care in order to make sure that the oil does not overheat and ignite.

CAUTION: Accessible parts of the hood may become hot when used with cooking appliances.

For lamp replacement use only lamp type indicated in the Maintenance/Replacing lamps section of this manual.

WARNING! Do not connect the appliance to the mains until the installation is fully complete.

With regards to the technical and safety measures to be adopted for fume discharging it is important to closely follow the regulations provided by the local authorities.

The ducting system for this appliance must not be connected to any existing ventilation system which is being used for any other purpose such as discharging exhaust fumes from appliances burning gas or other fuels.

Do not use or leave the hood without the lamp correctly mounted due to the possible risk of electric shocks.

Never use the hood without effectively mounted grids.

The hood must NEVER be used as a support surface unless specifically indicated.

Use only the fixing screws supplied with the product for installation or, if not supplied, purchase the correct screws type.

Use the correct length for the screws which are identified in the Installation Guide.

In case of doubt, consult an authorised service assistance centre or similar qualified person.

WARNING! Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.

We will not accept any responsibility for any faults, damage or fires caused to the appliance as a result of the non-observance of the instructions included in this manual.

This appliance is marked according to the European directive 2012/19/EC on Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.

ELICA Top Class Island IXBL/A/120 - Caution - 1

The symbol

on the product, or on the documents

accompanying the product, indicates that this appliance may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal.

For further detailed information regarding the process, collection and recycling of this product, please contact the appropriate department of your local authorities or the local department for household waste or the shop where you purchased this product.

Appliance designed, tested and manufactured according to:

- Safety: EN/IEC 60335-1; EN/IEC 60335-2-31, EN/IEC 62233.

- Performance: EN/IEC 61591; ISO 5167-1; ISO 5167-3; ISO 5168; EN/IEC 60704-1; EN/IEC 60704-2-13; EN/IEC 60704-3; ISO 3741; EN 50564; IEC 62301.

- EMC: EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2; EN/IEC 61000-3-2; EN/IEC 61000-3-3. Suggestions for a correct use in order to reduce the environmental impact: Switch ON the hood at minimum speed when you start cooking and kept it running for few minutes after cooking is finished. Increase the speed only in case of large amount of smoke and vapour and use boost speed(s) only in extreme situations. Replace the charcoal filter(s) when necessary to maintain a good odour reduction efficiency. Clean the grease filter(s) when necessary to maintain a good grease filter efficiency. Use the maximum diameter of the ducting system indicated in this manual to optimize efficiency and minimize noise.

Additional Installation Specifications:

Use only the fixing screws supplied with the product for installation or, if not supplied, purchase the correct screws type.

Use the correct length for the screws which are identified in the Installation Guide.

In case of doubt, consult an authorised service assistance centre or similar qualified person.

WARNING! Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.

Use

The hood is conceived for the suction of cooking fumes and steam and is destined only for domestic use.

The hood is designed to be used either for exhausting or filter version.

ELICA Top Class Island IXBL/A/120 - Use - 1

Ducting version

In this case the fumes are conveyed outside of the building by means of a special pipe connected with the connection ring located on top of the hood.

Attention! The exhausting pipe is not supplied and must be purchased apart.

Diameter of the exhausting pipe must be equal to that of the connection ring.

In the horizontal runs the exhausting pipe must be slightly slanted (about 10°) and directed upwards to vent the air easily from the room to the outside.

Attention! If the hood is supplied with active charcoal filter, then it must be removed.

Connect the hood and discharge holes on the walls with a diameter equivalent to the air outlet (connection flange).

Using the tubes and discharge holes on walls with smaller dimensions will cause a diminution of the suction performance and a drastic increase in noise.

Any responsibility in the matter is therefore declined.

! Use a duct of the minimum indispensable length. ! Use a duct with as few elbows as possible (maximum elbow angle: 90°). ! Avoid drastic changes in the duct cross-section. ! Use a duct as smooth as possible inside. ! The duct must be made of certified material.

ELICA Top Class Island IXBL/A/120 - Ducting version - 1

Filter version

The aspirated air will be degreased and deodorised before being fed back into the room.

In order to use the hood in this version, you have to install a system of additional filtering based on activated charcoal.

The models with no suction motor only operate in ducting mode, and must be connected to an external suction device (not supplied).

The connecting instructions are supplied with the peripheral suction unit.

Installation

The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood must be not less than 50cm from electric cookers and 65cm from gas or mixed cookers.

If the instructions for installation for the gas hob specify a greater distance, this must be adhered to.

ELICA Top Class Island IXBL/A/120 - Installation - 1

Electrical connection

The mains power supply must correspond to the rating indicated on the plate situated inside the hood. If provided with a plug, connect the hood to a socket in compliance with current regulations and positioned in an accessible area, after installation. If it is not fitted with a plug (direct mains connection) or if the plug is not located in an accessible area, after installation, apply a double pole switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to over-current category III, in accordance with installation instructions.

Warning! Before re-connecting the hood circuit to the mains supply and checking the efficient function, always check that the mains cable is correctly assembled.

The hood is provided with a special power cable; if the cable is damaged, request a new one from Technical Service.

Mounting

Before beginning installation:

  • Check that the product purchased is of a suitable size for the chosen installation area.
  • Remove the charcoal (*) filter/s if supplied (see also relative paragraph). This/these is/are to be mounted only if you want to use the hood in the filtering version.
  • Check (for transport reasons) that there is no other supplied material inside the hood (e.g. packets with screws (*), guarantees (*), etc.), eventually removing them and keeping them.
  • If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall/ceiling. Otherwise put a thick, protective covering over countertop, cooktop or range to protect from damage and debris. Select a flat surface for assembling the unit. Cover that surface with a protective covering and place all canopy hood parts and hardware in it.
  • In addition check whether near the installation area of the hood (in the area accessible also with the hood mounted) an electric socket is available and it is possible to connect a fumes discharge device to the outside (only suction version).
  • Carry out all the masonry work necessary (e.g. installation of an electric socket and/or a hole for the passage of the discharge tube).

This type of cooker hood must be fixed to the ceiling.

Very heavy product; hood handling and installation must be carried out by at least two persons.

Attention! Before connecting the hood to the electrical mains.

If you have an Elica hob:

Perform the electrical connections of the hood and Elica hob at the same time to ensure the logical connection between the hood and Elica hob (also refer to the paragraph "Operation-Adjusting the parameters for automatic operation-Sensor calibration" and "Operation-Adjusting the parameters for automatic operation-Logical connection between hood and Elica hob").

If you do NOT have an Elica hob:

In this case, after being connected to the mains, the hood will still try connecting to a hob.

Wait for the hood to complete the connection attempts (approximately 5 minutes) and then disable the electronic connection module as follows:

With the hood switched off, simultaneously press and

ELICA Top Class Island IXBL/A/120 - Before beginning installation: - 1

ELICA Top Class Island IXBL/A/120 - Before beginning installation: - 2

hold keys and for more than 10 seconds, (see Operation paragraph). The hood emits an acoustic signal (beep) indicating that the disabling process is complete.

Reactivating the connection module between the hood and Elica hob: With the hood switched off,

ELICA Top Class Island IXBL/A/120 - Before beginning installation: - 3

simultaneously press and hold keys and for more than 10 seconds, (see Operation paragraph). The hood emits an acoustic signal (beep) indicating that the disabling process is complete.

Expansion wall plugs are provided to secure the hood to most types of walls/ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling. The wall/ceiling must be strong enough to take the weight of the hood. Do not tile, grout or silicone this appliance to the wall. Surface mounting only.

Operation

Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking.

For certain models, a remote control is available as accessory kit, by which you can control the main functions of the hood. Check with your authorised dealer or technical assistance centre the compatibility/suitability of your model.

Control panel with 6 buttons

To select the functions of the hood just touch the commands.

ELICA Top Class Island IXBL/A/120 - Control panel with 6 buttons - 1

Light key ON/OFF

ELICA Top Class Island IXBL/A/120 - Light key ON/OFF - 1

Intensive speed selection key (suction power) - duration 5 minutes: the hood sets this power and at the end of the 5 minutes returns to the previous setting.

ELICA Top Class Island IXBL/A/120 - Light key ON/OFF - 2

High-speed selection key (suction power).

ELICA Top Class Island IXBL/A/120 - Light key ON/OFF - 3

Medium-speed selection key (suction power) - when flashing it indicates the need to wash or replace the carbon filter. This signal is normally deactivated. To activate the alarm, disable the electronic by pressing the 0 button for 3 seconds.

Next, simultaneously press buttons 1 and 2 for 3 seconds; at first, only button 1 will flash, then both buttons 1 and 2 will flash to indicate activation. Repeat the procedure to deactivate the alarm; at first buttons 1 and 2 will flash and subsequently only button 1 to indicate deactivation.

ELICA Top Class Island IXBL/A/120 - Light key ON/OFF - 4

Low-speed selection key (suction power) – when flashing it indicates the need to wash the

fats filter.

ELICA Top Class Island IXBL/A/120 - Light key ON/OFF - 5

Motor key OFF (stand by) – excludes the electronics – reset wash/replace filters signals. MOTOR OFF

Press briefly to switch the motor off.

RESET FILTERS SIGNALS

In functioning mode, after carrying out filter maintenance, press the key until hearing the sound signal. The flashing LED 1 (grease filter) or 2 (carbon filter) stops flashing.

EXCLUDING THE ELECTRONICS

Press the key for 3 seconds. The hood command electronics will be excluded.

This function can be useful during the product cleaning operations.

Just repeat the operation to reinsert the electronics.

If the hood fails to operate correctly, briefly disconnect it from the mains power supply for almost 5 sec. by pulling out the plug. Then plug it in again and try once more before contacting the Technical Assistance Service.

Control panel with 7 buttons

To select the functions of the hood you simply touch the controls.

ELICA Top Class Island IXBL/A/120 - Control panel with 7 buttons - 1

ELICA Top Class Island IXBL/A/120 - Control panel with 7 buttons - 2

Automatic operation (sensor) and connection with SNAP® and Elica hob (See related section)

ELICA Top Class Island IXBL/A/120 - Control panel with 7 buttons - 3

Button ON/OFF lighting

Press briefly to switch on or off the lighting of the hob. Press and hold to switch on or off the room lighting (only on certain models).

ELICA Top Class Island IXBL/A/120 - Button ON/OFF lighting - 1

Button for intensive speed (suction power) selection – it lasts 5 minutes then it returns to medium speed (suction power) or it switches off if the delayed shutdown of the hood is activated (only with remote control).

The button flashes in both cases to indicate speed timing.

ELICA Top Class Island IXBL/A/120 - Button ON/OFF lighting - 2

Button for high speed (suction power) selection.

The button flashes if the delayed shutdown of the hood is activated (only with remote control).

ELICA Top Class Island IXBL/A/120 - Button ON/OFF lighting - 3

Button for medium speed (suction power) selection

The button flashes if the delayed shutdown of the hood is activated (only with remote control).

ELICA Top Class Island IXBL/A/120 - Button ON/OFF lighting - 4

Button for low speed (suction power) selection – when flashing, it indicates that you must wash the grease filter.

The button flashes if the delayed shutdown of the hood is activated (only with remote control).

ELICA Top Class Island IXBL/A/120 - Button ON/OFF lighting - 5

Button OFF motor (stand by)

Indicators of Filter Saturation

At regular time intervals, the hood signals the need to perform filter maintenance.

ELICA Top Class Island IXBL/A/120 - Indicators of Filter Saturation - 1

Button MAX on with steady light: perform grease filter maintenance.

ELICA Top Class Island IXBL/A/120 - Indicators of Filter Saturation - 2

Button MAX flashing: perform activated charcoal filter maintenance.

Note: Filter saturation signal is visible within the first minute after switching off the hood; within this time, the reset of saturation indicators must be performed.

Reset of filter saturation indicators:

Press and hold the button

ELICA Top Class Island IXBL/A/120 - Reset of filter saturation indicators: - 1

Activation of saturation indicator activated charcoal filter

Note: this operation must be performed with the hood off. This indicator is normally deactivated; press and hold the

ELICA Top Class Island IXBL/A/120 - Activation of saturation indicator activated charcoal filter - 1

Press the MAX button to activate the function: the button lights up with a steady light.

To deactivate the function, press and hold the button

ELICA Top Class Island IXBL/A/120 - Activation of saturation indicator activated charcoal filter - 2

: the button lights up flashing.

Automatic operation (sensor), connection with SNAP® and Elica hob

Attention! The proper operation of the hood will depend on the 'Setting of parameters for Automatic Operation' (see dedicated section).

Note: Automatic operation with the hob is only possible with specific hobs. For further details, please contact the official dealer or authorized technical assistance center.

Automatic operation (sensor)

Press the button. (The central LED "c" lights up in

white.

The hood will switch on at the most suitable speed based on the cooking fumes detected by the sensor on the hood.

Automatic operation of the hood with SNAP®

Press the button. (The LEDs "a" - "b" light up in orange

ELICA Top Class Island IXBL/A/120 - Automatic operation of the hood with SNAP® - 1

(1) to indicate that the hood can operate automatically with the SNAP®.

Note: SNAP® is an auxiliary suction unit that can operate

together with the hood. For further information, please consult the manual supplied with SNAP®.

Automatic operation of the hood with the Elica hob

Operation of the hood will also depend on use of the Elica hob.

ELICA Top Class Island IXBL/A/120 - Automatic operation of the hood with the Elica hob - 1

Press the button. (The LEDs "c" and "d" light up in white to indicate that the hood can automatically operate with the Elica hob; thus, hood operation will also depend on the Elica hob.)

ELICA Top Class Island IXBL/A/120 - Automatic operation of the hood with the Elica hob - 2

Press the button. (The LEDs "c" and "d" light up in white to indicate that the hood can automatically operate with the Elica hob; thus, hood operation will also depend on the Elica hob.)

Note: Automatic operation with the hob is possible only with specific cooking hobs; for further details, please contact the authorised dealer or technical assistance centre.

Automatic operation of the hood with SNAP® and Elica hob

Press the button Ⓗ. (The LEDs "a", "b", and "e" light up in orange (S) to indicate that the hood can operate automatically with the hob and the SNAP®.)

Press the button Ⓗ. (The LEDs "a", "b", and "e" light up in orange (S) to indicate that the hood can operate automatically with the hob and the SNAP®.)

Setting of parameters for Automatic Operation

Note: All calibration, selection, setting and logical connection operations described below can be performed with the hood off (OFF).

The adjustment of parameters is regularly done automatically every time the hood is reconnected to the mains (e.g. with the first installation or after a blackout) or manually.

Manual setting

To be performed when you notice unsatisfactory functioning of the Automatic operation, and is done when normal environmental conditions persist in the kitchen.

Manual setting includes:

- Hood calibration

  • Selection of hob (gas, induction, or electric)
  • Logical connection between the hood and the hob (if you have an Elica hob).

Logical connection between the hood and SNAP® (if you have SNAP®).

Hood calibration

Press and hold the button 📋, all button LEDs flash to indicate initiation of calibration; the process will last for approximately 5 minutes.

ELICA Top Class Island IXBL/A/120 - Hood calibration - 1

Selection of the hob (gas, induction, or electric)

Press and hold simultaneously the buttons

ELICA Top Class Island IXBL/A/120 - Hood calibration - 2

2: buttons, and start flashing for 5 seconds.

Within this timeframe, press:

button 1 in case of gas hob button 2 in case of electric hob button 3 in case of induction hob

The preselected button remains lit to indicate the selection was performed, after 10 seconds the button flashes briefly to indicate that the performed selection was recorded.

Logical connection between the hood and the hob (if you have an Elica hob).

a. Simultaneously connect the hood and Elica hob. b. the hood emits 2 acoustic signals (beeps) to indicate that it can receive the connection signal from the Elica hob. c. the connection attempts with the Elica hob last for 5 minutes; within this time, the hood emits 3 consecutive acoustic signals (beeps) to indicate the successful connection with the Elica hob. d. Check the successful connection with the Elica

hob: Press the button Ⓗ. (the LEDs "c"- "d")

ELICA Top Class Island IXBL/A/120 - Logical connection between the hood and the hob (if you have an Elica hob). - 1

light up in white

In case the logical connection between the hood and Elica hob is not successful, proceed as indicated below:

Disconnect and reconnect the hood from/to the mains at least 5 times within 30 seconds.

Repeat the operations a-b-c-d described above

Logical connection between the hood and SNAP® (if you possess a SNAP®).

Connection between the hood and SNAP® is automatic. No other setting has to be performed.

Remote control

Warning! Some functions of this remote control may only be activated with certain hood models.

L3 T1 T2 T3 T3a T4 T3 T3b T3 T3d T3 T3c T5 T6 SENSOR T7 RESET FILTER

Remote control affiliation:

Keep T2 + T5 pressed within the first minute the hood is powered. Once pairing is complete it is displayed on the hood.

Description of the remote control functions

T1. OFF key T2. ON/OFF key and dim light intensity adjustment T3. Suction speed (power) control key: T4. Hob light ON/OFF key T5. Delayed hood ON/OFF key T6. Sensor ON/OFF key. T7. Filter saturation warning reset key. L3. Remote control operation LED

Note: touch the keys lightly to select the available functions.

T1. OFF key Press to switch the hood off T2. ON/OFF key and dim light intensity adjustment Press briefly to switch the dim light on or off Press longer to adjust intensity. Note: The dim light is only available on some models.

T3. Suction speed (power) control key Touch the key starting from any position, turning it clockwise or anticlockwise to increase or decrease suction speed. The key is divided into several sectors. You can select the desired speed directly in the corresponding sector as follows:

T3a: Speed 1 (low suction)

T3b: Speed 2 (medium suction)

T3c: Speed 3 (high suction)

T3d: Speed 4 (intensive suction)

T4. Hob light ON/OFF key Press to switch the hob light on or off.

T5. Delayed hood ON/OFF key. Press to program the delayed switch-off of the hood based on the suction speed (power) active at that moment:

Speed 1 (low suction): 20 minutes

Speed 2 (medium suction): 15 minutes

Speed 3 (high suction): 10 minutes

T6. Sensor ON/OFF key Keep it pressed to activate/deactivate the mode with sensor which manages fume extraction in automatic mode.

Note: The sensor is only available in some models.

T7. Filter saturation warning reset key.

Maintenance of the remote control

Cleaning the remote control:

Clean the remote control with a damp cloth and a neutral solution of detergent without abrasive substances.

Changing the battery:

  • Open the battery casing.
  • Replace the flat batteries with 3 new 1.5 V type AAA batteries.

Respect the polarity indicated in the battery casing when inserting the new battery!

- Close the battery casing up again.

+1.5V - AAA - -1.5V - AAA + C

Disposal of the batteries

Ultimate disposal of the batteries should be handled according to all national laws and regulations. Do not place used batteries in your regular waste.

Ultimate disposal of the batteries must be done safely.

Contact your local waste management officials for other information regarding the environmentally sound collection, recycling, and disposal of the batteries.

Maintenance

ATTENTION! Before performing any maintenance operation, isolate the hood from the electrical supply by switching off at the connector and removing the connector fuse.

Or if the appliance has been connected through a plug and socket, then the plug must be removed from the socket.

Cleaning

The cooker hood should be cleaned regularly (at least with the same frequency with which you carry out maintenance of the fat filters) internally and externally. Clean using ONLY the cloth dampened with neutral liquid detergent. DO NOT

CLEAN WITH TOOLS OR INSTRUMENTS. Do not use abrasive products. DO NOT USE ALCOHOL!

Warning! Failure to carry out the basic cleaning recommendations of the cooker hood and replacement of the filters may cause fire risks.

Therefore, we recommend observing these instructions.

The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.

Grease filter

Fig. 26-31

Traps cooking grease particles.

This must be cleaned once a month (or when the filter saturation indication system – if envisaged on the model in possession – indicates this necessity) using non aggressive detergents, either by hand or in the dishwasher, which must be set to a low temperature and a short cycle.

When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity.

To remove the grease filter, pull the spring release handle.

Charcoal filter (filter version only)

Fig. 28

It absorbs unpleasant odours caused by cooking.

The activated charcoal filter can be one of these types:

- Washable activated charcoal filter.

• NON-washable activated charcoal filter.

Washable activated charcoal filter

The charcoal filter can be washed once every two months using hot water and a suitable detergent, or in a dishwasher at 65°C (if the dishwasher is used, select the full cycle function and leave dishes out).

Eliminate excess water without damaging the filter, then remove the mattress located inside the plastic frame and put it in the oven for 10 minutes at 100°C to dry completely. Replace the mattress every 3 years and when the cloth is damaged.

NON-washable activated charcoal filter

The saturation of the charcoal filter occurs after more or less prolonged use, depending on the type of cooking and the regularity of cleaning of the grease filter.

In any case it is necessary to replace the cartridge at least every four months.

The charcoal filter may NOT be washed or regenerated.

Assembly

Hook the charcoal filter at the back on the metal tongue of the hood first, then on the front with the two knobs.

Disassembly

Remove the charcoal filter by turning the knobs fixing it to the hood by 90°.

Replacing lamps

The hood is equipped with a lighting system based on LED technology.

The LEDs guarantee an optimum lighting, a duration up to 10 times as long as the traditional lamps and allow to save 90% electrical energy.

For replacement, contact the technical service.

MOTOR OFF button

Light ON/OFF button

Motor OFF button (stand by)

H 5

16 x Ø 3.5x9.5mm 6

FRONT SX RX H - 11cm 7

Diagram illustrating a mechanical device with labeled parts and directional arrows, including a house icon and a numbered section 8.

Technical diagram illustrating a mechanical assembly with labeled components and directional arrows, including a magnified inset showing cross-sectional views.

10

11

16 x Ø 3.5x9.5mm 12

13 x 4

14 x 2

Ø 150 mm x 1 15

Ø 120÷125 mm * * *

ELICA Top Class Island IXBL/A/120 - Light ON/OFF button - 13

ELICA Top Class Island IXBL/A/120 - Light ON/OFF button - 14

ELICA Top Class Island IXBL/A/120 - Light ON/OFF button - 15

8 x Ø 3.5x9.5mm 17

H Min

18 x 8 x 4 x 4

19

220-240 V ~ 50-60 Hz 8 x Ø M4x7mm 20

21 2 x Ø 3x9mm

22 x 6 x 6

23

6 x Ø M4x7mm 24

25

26

2 x Ø 3x9mm 27

28.1 28.2 28 28.3

28.4

29

30

31

DO NOT USE ALCOHOL!

- Waste Electrical and Electronic Equipment (WEEE).

Use the correct length for the screws which are identified in the Installation Guide.

MOTOR OFF BUTTON

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ELICA

Model : Top Class Island IXBL/A/120

Category : Range hood