| Type de produit | Capteur photoelectrique de proximite |
| Marque | Omron |
| Modele | E3ZM |
| Boitier | Acier inoxydable SUS316L compact |
| Indice de protection | IP67, IP69K |
| Alimentation | 10 a 30 VCC (incl. 10% d'ondulation) |
| Types de sortie | NPN ou PNP, collecteur ouvert, 100 mA max. |
| Portees disponibles | De 0,8 m (barrage avec fentes) a 15 m (barrage sans fentes) |
| Mode de detection | Barrage, retroreflexion, diffusion, BGS (arriere-plan) |
| Source lumineuse | LED rouge (660 nm) ou infrarouge (870 nm) |
| Reglage de sensibilite | Potentiometre un tour |
| Temps de reponse | 1 ms max. (marche ou arret) |
| Poids (modele pre-cable) | Environ 90 a 150 g selon modele |
| Poids (modele connecteur) | Environ 40 a 60 g selon modele |
| Materiaux principaux | Boitier SUS316L, lentille PMMA, joint FPM, indicateur PES, ajustement PEEK |
| Resistance aux detergents | Testee avec NaOH 1,5%, H2O2 6,5%, etc. (voir tableau) |
| Temperature ambiante | -25 a 55°C (fonctionnement), -40 a 70°C (stockage) |
| Humidite ambiante | 35 a 85% (fonctionnement), 35 a 95% (stockage) |
| Raccordement | Cable pre-cable 2 m ou connecteur M8 4 broches |
| Accessoires fournis | Notice d'instructions (reflecteurs et supports vendus separement) |
FOIRE AUX QUESTIONS - E3ZM OMRON
Questions des utilisateurs sur E3ZM OMRON
0 question sur cet appareil. Repondez a celles que vous connaissez ou posez la votre.
Poser une nouvelle question sur cet appareil
Téléchargez la notice de votre Capteurs de proximité au format PDF gratuitement ! Retrouvez votre notice E3ZM - OMRON et reprennez votre appareil électronique en main. Sur cette page sont publiés tous les documents nécessaires à l'utilisation de votre appareil E3ZM de la marque OMRON.
MODE D'EMPLOI E3ZM OMRON
Photoelectric sensor in compact stainless steel housing
E3ZM
- Compact size SUS 316L housing for highest mechanical protection
- Tested detergent and chemical resistance (certified by Henkel-Ecolab)
- Watertight construction for highest protection when cleaned with high pressure

Application
Detergent resistance

proven in intensive testing
| Product name | Concen- tration | Temper- ature | Time |
| Sodium hydroxide (NaOH) | 1.5 % | 70 °C | 240 h |
| Potassium hydroxide (KOH) | 1.5 % | 70 °C | 240 h |
| Phosphoric acid (H3PO4) | 2.5 % | 70 °C | 240 h |
| Sodium hypochlorite (NaClO) | 0.3 % | 25 °C | 240 h |
| Hydrogen peroxide (H2O2) | 6.5 % | 25 °C | 240 h |
| P3-topax-66s (Manufactured by Ecolab) | 3.0 % | 70 °C | 240 h |
| P3-topax-56 (Manufactured by Ecolab) | 5.0 % | 70 °C | 240 h |
| P3-oxonia active 90 (Manufactured by Ecolab) | 1.0 % | 25 °C | 240 h |
| TEK121 (Manufactured by ABC Compounding) | 1.1 % | 25 °C | 240 h |
Product concept for highest machine hygiene
and often cleaned environments.

Waterproofing ring: Fluorine rubber
Excellent resistance to detergents and disinfectants.
Optical plate: Methacrylic resin (PMMA)
Excellent resistance to detergents and disinfectants. High transparency and other qualities give PMMA excellent optical characteristics.
Seal
The seal provides the resistance to high-temperature and high-pressure water that complies with IP69K.
Indicator cover: Polyether Sulfone (PES)
Excellent resistance to detergents and disinfectants.
Sensitivity adjustment and operation switch: Polyether etherketone (PEEK)
Excellent resistance to detergents and disinfectants. Also has excellent abrasion resistance.
Case:SUS316L
Excellent corrosion resistance to many chemical reagents.
Cable: Vinyl chloride
Excellent resistance to detergents and disinfectants.
Red light Infrared light
Sensors
| Sensor type | Appearance | Connection method | Sensing distance | Model | ||||
| NPN output | PNP output | |||||||
| Through-beam *1 | → | Pre-wired (2 m) *2 | 15m | E3ZM-T61 | E3ZM-T81 | |||
| Connector type(M8, 4 pins) *3 | E3ZM-T66 | E3ZM-T86 | ||||||
| Pre-wired (2 m) *2 | 0.8 mwith built-in slits | E3ZM-T63 | E3ZM-T83 | |||||
| Connector type(M8, 4 pins) *3 | E3ZM-T68 | E3ZM-T88 | ||||||
| Retroreflective(with M.S.R.function) | ←→ *4 | Pre-wired (2 m) *2 | 4m[100mm] | *5 | E3ZM-R61 | E3ZM-R81 | ||
| Connector type(M8, 4 pins) *3 | (Using E39-R1S) | E3ZM-R66 | E3ZM-R86 | |||||
| Diffuse-reflective | ←→ | Pre-wired (2 m) *2 | 1m | E3ZM-D62 | E3ZM-D82 | |||
| Connector type(M8, 4 pins) *3 | E3ZM-D67 | E3ZM-D87 | ||||||
| BGS reflective(fixed distance) | ←→ | Pre-wired (2 m) *2 | 10 to 100 mm | E3ZM-LS61H | E3ZM-LS81H | |||
| Connector type(M8, 4 pins) *3 | E3ZM-LS66H | E3ZM-LS86H | ||||||
| Pre-wired (2 m) *2 | 10 to 150 mm | E3ZM-LS62H | E3ZM-LS82H | |||||
| Connector type(M8, 4 pins) *3 | E3ZM-LS67H | E3ZM-LS87H | ||||||
| Pre-wired (2 m) *2 | 10 to 200 mm | E3ZM-LS64H | E3ZM-LS84H | |||||
| Connector type(M8, 4 pins) *3 | E3ZM-LS69H | E3ZM-LS89H | ||||||
1. Through-beam Models are also available with a light emission stop function. When ordering, add "-G0" to the end of the model number (e.g.,E3ZM-T61-G0).
2. Pre-wired Models with a 5 m cable are also available for these products. When ordering, specify the cable length by adding "5M" to the end of the model number (e.g., E3ZM-LT61 5M).
M12 Pre-wired Connector Models are also available. When ordering, add "-M1J" to the end of the model number (e.g., E3ZM-R61-M1J 0.3m).
3. M8 Connector Models are also available with three-pin connectors. When ordering, add "-M5" to the end of the model number (e.g., E3ZM-T66-M5).
This does not apply to BGS Reflective Models, however, because they require 4 pins.
4. The Reflector is sold separately. Select the Reflector model most suited to the application.
*5. Values in parentheses indicate the minimum required distance between the Sensor and Reflector..
Accessories
Reflectors
| Name | E3ZM-R Sensing distance (typical) *1 | Model | Quantity | Remarks |
| Reflector | 3 m [100 mm] (rated value) | E39-R1 | 1 | • Reflectors are not provided with Retro-reflective models. • The MSR function is enabled. |
| 4 m [100 mm] (rated value) | E39-R1S | 1 | ||
| 5 m [100 mm] | E39-R2 | 1 | ||
| 2.5 m [100 mm] | E39-R9 | 1 | ||
| 3.5 m [100 mm] | E39-R10 | 1 | ||
| Fog preventing | 3 m [100 mm] | E39-R1K | 1 | |
| Small reflector | 1.5 m [50 mm] | E39-R3 | 1 | |
| Tape Reflector | 700 mm [150 mm] | E39-RS1 | 1 | |
| 1.1 m [150 mm] | E39-RS2 | 1 | ||
| 1.4 m [150 mm] | E39-RS3 | 1 |
*1. Values in parentheses indicate the minimum required distance between the Sensor and Reflector.
Note: 1 . When using a Reflector without a rated value, use 0.7 times typical value as a guideline for the sensing distance.
2. For stainless steel and glass covered reflectors please contact your OMRON representative.
Mounting Brackets
| Shape | Model | Quantity | Remarks | Appearance | Model | Quantity | Remarks |
| E39-L153 | 1 | Mounting Brackets | E39-L98 | 1 | Metal Protective Cover Bracket *1 | ||
| E39-L104 | 1 | E39-L150 | One set | (Sensor adjuster) | |||
| E39-L43 | 1 | Horizontal Mounting Bracket *1 | E39-L151 | One set | Easily mounted to the aluminum frame rails of conveyors and easily adjusted. | ||
| E39-L142 | 1 | Horizontal Protective Cover Bracket *1 | For left to right adjustment | ||||
| E39-L44 | 1 | Rear Mounting Bracket | E39-L144 | 1 | Compact Protective Cover Bracket *1 |
*1. Cannot be used for Standard Connector models.
Note: 1 . When using Through-beam Models, order one bracket for the Receiver and one for the Emitter.
Sensor I/O Connectors
General Purpose
| Size | Cable | Appearance | Cable type | Model | |
| M8 (4 pins) | Standard | Straight | 2 m | 4-wire type | XS3F-M421-402-A |
| 5 m | XS3F-M421-405-A | ||||
| L-shaped | 2 m | XS3F-M422-402-A | |||
| 5 m | XS3F-M422-405-A | ||||
| M12 (For -M1J models) | Straight | 2 m | 3-wire type | XS2F-D421-DC0-A | |
| 5 m | XS2F-D421-GC0-A | ||||
| L-shaped | 2 m | XS2F-D422-DC0-A | |||
| 5 m | XS2F-D422-GC0-A | ||||
| Straight | 2 m | 4-wire type | XS2F-D421-D80-A | ||
| 5 m | XS2F-D421-G80-A | ||||
| L-shaped | 2 m | XS2F-D422-D80-A | |||
| 5 m | XS2F-D422-G80-A | ||||
Note: Depending on the connector specification, the IP67 performance applies. When using high-pressure washing, use a suitable connector.
Detergent resistant sensor I/O connectors
Please contact your OMRON representative for sensor connectors with stainless steel nuts.
| Sensor method | Through-beam | Retroreflective model (with M.S.R. function) | Diffuse-reflective Models | ||
| Item | NPN output | E3ZM-T61 | E3ZM-T63 | E3ZM-R61 | E3ZM-D62 |
| E3ZM-T66 | E3ZM-T68 | E3ZM-R66 | E3ZM-D67 | ||
| PNP output | E3ZM-T81 | E3ZM-T83 | E3ZM-R81 | E3ZM-D82 | |
| E3ZM-T86 | E3ZM-T88 | E3ZM-R86 | E3ZM-D87 | ||
| Sensing distance | 15 m | 0.8 m | 4 m [100 mm] (Using E39-R1S) 3 m [100 mm] (Using E39-R1) | 1 m (White paper 300 x 300 mm) | |
| Spot Diameter (typical) | --- | ||||
| Standard sensing object | Opaque: 12 mm dia. min. | Opaque: 2 mm dia. min. | Opaque: 75 mm dia. min. | --- | |
| Differential travel | --- | 20% max. of sensing distance max. | |||
| Black/white error | --- | ||||
| Directional angle | Emitter and Receiver: 3° to 15° | Sensor: 3° to 10° Reflector: 30° | --- | ||
| Light source (wave length) | Infrared LED (870 nm) | Red LED (660 nm) | Infrared LED (860 nm) | ||
| Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | ||||
| Current consumption | Emitter, Receiver: 20 mA max. each | 25 mA max. | |||
| Control output | Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 2 V max.) Open-collector output (NPN/PNP output depending on model) Light-ON/Dark-ON switch selectable | ||||
| Protection circuits | Reversed power supply polarity protection, Output short-circuit protection, and Reversed output polarity protection | Reversed power supply polarity protection, Output short-circuit protection, Mutual interference prevention, and Reversed output polarity protection | |||
| Response time | Operate or reset: 1 ms max. | ||||
| Sensitivity adjustment | One-turn adjuster | ||||
| Ambient illumination (Receiver side) | Incandescent lamp: 3,000 lx max. Sunlight 10,000 lx max. | ||||
| Ambient temperature range | Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) | ||||
| Ambient humidity range | Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) | ||||
| Insulation resistance | 20 MΩ min. at 500 VDC | ||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance | Destruction: 500 m/s² 3 times each in X, Y, and Z directions | ||||
| Degree of protection *1 | IEC: IP67, DIN 40050-9: IP69K | ||||
| Connection method | Pre-wired cable (standard length: 2 m) Standard M8 4-pin Connector | ||||
| Indicator | Operation indicator (yellow), Stability indicator (green) (Emitter has only power supply indicator (green).) | ||||
| Weight (packed state) | Pre-wired cable | Approx. 150 g | Approx. 90 g | ||
| Standard Connector | Approx. 60 g | Approx. 40 g | |||
| Materials | Case | SUS316L | |||
| Lens | Methacrylic resin | ||||
| Display | PES (polyether sulfone) | ||||
| Sensitivity adjustment and operation switch | PEEK (polyether ether ketone) | ||||
| Seals | Fluoro rubber | ||||
| Accessories | Instruction sheet (Note: Reflectors and Mounting Brackets are sold separately.) | ||||
*1. IP69K Degree of Protection Specification IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050, Part 9.The test piece is sprayed with water at 80^ at a water pressure of 80 to 100 BAR using a specified nozzle shape. The distance between the test piece and nozzle is 10 to 15cm , and water is sprayed horizontally for 30 seconds each at 0^ , 30^ , 60^ , and 90^ while rotating the test object on a horizontal plane.

Rating and Specifications
| Sensor method | BGS Reflective Models | |||
| Model | NPN output | E3ZM-LS61H | E3ZM-LS62H | E3ZM-LS64H |
| E3ZM-LS66H | E3ZM-LS67H | E3ZM-LS69H | ||
| PNP output | E3ZM-LS81H | E3ZM-LS82H | E3ZM-LS84H | |
| E3ZM-LS86H | E3ZM-LS87H | E3ZM-LS89H | ||
| Item | ||||
| Sensing distance | 10 to 100 mm(White paper 100 x 100 mm) | 10 to 150 mm(White paper 100 x 100 mm) | 10 to 200 mm(White paper 100 x 100 mm) | |
| Spot Diameter (typical) | 4 mm dia. at sensing distance of 100 mm | 12 mm dia. at sensing distance of 150 mm | 18 mm dia. at sensing distance of 200 mm | |
| Standard sensing object | --- | |||
| Differential travel | 3% of sensing distance max. | 15% of sensing distance max. | 20% of sensing distance max. | |
| Black/white error | 5% of sensing distance max. | 10% of sensing distance max. | 20% of sensing distance max. | |
| Directional angle | --- | |||
| Light source (wave length) | Red LED (650 nm) | Red LED (660 nm) | ||
| Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | |||
| Current consumption | 25 mA max. | |||
| Control output | Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 2 V max.)Open-collector output (NPN/PNP output depending on model)Light-ON/Dark-ON cable connection selectable | |||
| Protection circuits | Reversed power supply polarity protection, Output short-circuit protection, Reversed output polarity protection, Mutual interference protection | |||
| Response time | Operate or reset: 1 ms max. | |||
| Sensitivity adjustment | --- | |||
| Ambient illumination(Receiver side) | Incandescent lamp: 3,000 lx max. Sunlight 10,000 lx max. | |||
| Ambient temperature range | Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) | |||
| Ambient humidity range | Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) | |||
| Insulation resistance | 20 MΩ min. at 500 VDC | |||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute | |||
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions | |||
| Shock resistance | Destruction: 500 m/s² 3 times each in X, Y, and Z directions | |||
| Degree of protection *1 | IEC: IP67, DIN 40050-9: IP69K | |||
| Connection method | Pre-wired cable (standard length: 2 m)Standard M8 4-pin Connector | |||
| Indicator | Operation indicator (yellow), Stability indicator (green) | |||
| Weight(packed state) | Pre-wired cable | Approx. 90 g | ||
| StandardConnector | Approx. 40 g | |||
| Materials | Case | SUS316L | ||
| Lens | Methacrylic resin | |||
| Display | PES (polyether sulfone) | |||
| Sensitivity adjustment and operation switch | PEEK (polyether ether ketone) | |||
| Seals | Fluoro rubber | |||
| Accessories | Instruction sheet (Note: Mounting Brackets are sold separately.) | |||
1. IP69K Degree of Protection Specification
2. IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050,
3. Part 9. The test piece is sprayed with water at 80^ at a water pressure of 80 to 100 BAR using a specified nozzle shape.
4. The distance between the test piece and nozzle is 10 to 15 cm ,and water is sprayed horizontally for 30 seconds
*5. each at 0^ ,30^ ,60^ ,and 90^ while rotating the test object on a horizontal plane.

Parallel Operating Range
Through-beam Models
E3ZM-T□1(T□6)

Retro-reflective Models
E3ZM-R□1(R□6)

Operating Range
Diffuse-reflective Models
E3ZM-S□2(D□7)

BGS Reflective Models
E3ZM-LS□1H(LS□6H), Top to Bottom

E3ZM-LS□1H(LS□6H), Left to Right

E3ZM-LS□2H(LS□7H), Top to Bottom

E3ZM-LS□2H(LS□7H), Left to Right

E3ZM-LS□4H(LS□9H), Top to Bottom

E3ZM-LS□4H(LS□9H), Left to Right
Excess Gain vs. Distance

Through-beam Models
E3ZM-T□1(T□6)

Retro-reflective Models
E3ZM-R□1(R□6)
Diffuse-reflective Models

E3ZM-D□2(D□7)
Sensing Object Size vs. Distance

Diffuse-reflective Models
E3ZM-D□2(D□7)
Spot Diameter vs. Distance

BGS Reflective Models
E3ZM-LS□1H(LS□6H)

E3ZM-LS□2H/LS□4H(LS□7H/LS□9H)
Sensing Distance vs. Sensing Object Material

BGS Reflective Models

E3ZM-LS2H(LS7H)

E3ZM-LS□4H(LS□9H)
Inclination Characteristics (Vertical)

BGS Reflective Models

E3ZM-LS□2H(LS□7H)

E3ZM-LS□4H(LS□9H)
Inclination Characteristics (Horizontal)

BGS Reflective Models

E3ZM-LS□2H(LS□7H)

E3ZM-LS□4H(LS□9H)
NPN output
| Model | Operation mode | Timing charts | Mode selector switch | Output circuit |
| E3ZM-T61E3ZM-T63E3ZM-T66E3ZM-T68E3ZM-R61E3ZM-R66E3ZM-D62E3ZM-D67 | Light ON | Light Incident Light Interrupted Operation indicator (yellow) OFF Output transistor ON OFF Load (e.g., relay) Operate Reset (Between brown and black leads) | L side (LIGHT ON) | Through-beam Receivers, Retro-reflective Models, Diffuse-reflective Models |
| Dark ON | Light Incident Light Interrupted Operation indicator (yellow) OFF Output transistor ON OFF Load (e.g., relay) Operate Reset (Between brown and black leads) | D side (DARK ON) | Operation indicator (Yellow) Stability indicator (Green) (Control output) (Control output) 100 mA max. Black Blue 0 V | |
| Through-beam Emitter | ||||
| E3ZM-T61-G0E3ZM-T63-G0E3ZM-T66-G0E3ZM-T68-G0 | --- | Light emission stop function ON OFF (Between blue (3) and pink (2) leads) Emitter LED ON OFF ON OFF Indicator (green) | --- | Through-beam Emitter Power indicator (Green) Brown 10 to 30 VDC Photo-electric Sensor Main Circuit Pink (Light emission stop input) Blue 0 V |
| E3ZM-LS61H E3ZM-LS66H E3ZM-LS62H E3ZM-LS67H E3ZM-LS64H E3ZM-LS69H | Light ON | Operation indicator (yellow) ON OFF Load (e.g., relay) Operate Reset (Between brown and black leads) | Connect pink lead (2) to brown lead (1). | Operation indicator (yellow) Stability indicator (Green) Brown 10 to 30 VDC Photo-electric Sensor Main Circuit Black 4 0% Dark-ON 0 V |
| Dark ON | Operation indicator (yellow) ON OFF Output transistor ON OFF Load (e.g., relay) Operate Reset (Between brown and black leads) | Connect pink lead (2) to blue lead (3) or leave open. | ||
PNP output
| Model | Operation mode | Timing charts | Mode selector switch | Output circuit |
| E3ZM-T81E3ZM-T83E3ZM-T86E3ZM-T88E3ZM-R81E3ZM-R86E3ZM-D81E3ZM-D86E3ZM-D82E3ZM-D87 | Light ON | Light Incident Light Interrupted Operation indicator ON (yellow) OFF Output transistor ON OFF Load (e.g., relay) Operate Reset (Between brown and black leads) | L side (LIGHT ON) | Through-beam Receivers, Retro-reflective Models, Diffuse-reflective Models Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 30 VDC Operation Indicator (Green) Stability Indicator (Red) Blue 0 V |
| Dark ON | Light Incident Light Interrupted Operation indicator ON (yellow) OFF Output transistor ON OFF Load (e.g., relay) Operate Reset (Between brown and black leads) | D side (DARK ON) | ||
| Through-beam Emitter | ||||
| E3ZM-T81-G0E3ZM-T83-G0E3ZM-T86-G0E3ZM-T88-G0 | ... | Light emission stop function ON OFF (Between brown (1) and pink (2) leads) Emitter LED ON OFF ON OFF | ... | Through-beam Emitter Power indicator (Green) Brown 10 to 30 VDC Operation indicator (Green) Stability Indicator (Green) Black 10 to 30 VDC Operation Indicator (Yellow) Stability Indicator (Green) Black 10 to 30 VDC Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 30 VDC Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 30 VDC Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 30 VDC Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 30 VDC Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 3V |
| E3ZM-LS81H E3ZM-LS86H E3ZM-LS82H E3ZM-LS87H E3ZM-LS84H E3ZM-LS89H | Light ON | Operation indicator ON (yellow) OFF Output transistor ON OFF Load (e.g., relay) Operate Reset (Between blue and black leads) | Connect pink lead (2) to brown lead (1). | Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 30 VDC Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 30 VDC Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 30 VDC Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 30 VDC Operation indicator (Yellow) Stability Indicator (Green) Black 10 to 100 mA max. Operation (Relay) Load (Relay) Dark-ON 0 V |
| Dark ON | Operation indicator ON (yellow) OFF Output transistor ON OFF Load (e.g., relay) Operate Reset (Between blue and black leads) | Connect pink lead (2) to blue lead (3) or leave open. | ||
Connector Pin Arrangement
M12 Pre-wired Connector (-M1J)
M12 Connector Pin Arrangement

Connectors (Sensor I/O connectors)

M8 4-pin Connectors


M12 3-wire Connectors

M8 Connector/M8 Pre-wired Connector (-M3J) M8 4-pin Connector Pin Arrangement

M8 Pre-wired 3-pin Connector (-M5J) M8 3-pin Connector Pin Arrangement


M12 4-wire Connectors

| Classification | Wire color | Connector pin No. | Application |
| DC | Brown | ① | Power supply (+V) |
| White | ② | Light emission stop input/operation selection | |
| Blue | ③ | Power supply (0 V) | |
| Black | ④ | Output |
Note: The above M8 and M12 Connectors made by OMRON are IP67.
Do not use in an environment where IP69K is required.
Nomenclature
Sensors with Sensitivity Adjustment and Mode Selector Switch
Through-beam Models
E3ZM-T□□ (Receiver)
Retro-reflective Models
E3ZM-R□□
Diffuse-reflective Models
E3ZM-D□□

Infinite Adjustment Emitter
BGS Reflective Models
E3ZM-LS□□H
Through-beam Models
E3ZM-T□□ (Emitter)

Safety Precautions
Refer to Warranty and Limitations of Liability on page 20.

Warning
This product is not designed or rated for ensuring safety of persons. Do not use it for such purpose.


Caution
Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire.

Never use the product with an AC power supply. Otherwise, explosion may result.

When cleaning the product, do not apply a concentrated spray of water to one location. Otherwise, parts may become damaged and the degree of protection may be degraded.

High-temperature environments may result in burn injury.

Precautions for Safe Use
The following precautions must be observed to ensure safe operation of the Sensor.
Operating Environment
Do not use the Sensor in an environment where explosive or flammable gas is present.
Connecting Connectors
Be sure to hold the connector cover when inserting or removing the connector. Be sure to tighten the connector lock by hand; do not use pliers or other tools. If the tightening is insufficient, the degree of protection will not be maintained and the Sensor may become loose due to vibration. The appropriate tightening torque is 0.3 to 0.4N· m .
Load
Do not use a load that exceeds the rated load.
Low-temperature Environments
Do not touch the metal surface with your bare hands when the temperature is low. Touching the surface may result in a cold burn.
Rotation Torque for Sensitivity Adjustment and Selector Switch
Adjust with a torque of 0.06 N·m or less.
Oily Environments
Do not use the Sensor in oily environments.
Modifications
Do not attempt to disassemble, repair, or modify the Sensor. Outdoor Use
Do not use the Sensor in locations subject to direct sunlight. Cleaning
Do not use thinner, alcohol, or other organic solvents. Otherwise, the optical properties and degree of protection may be degraded. Washing
Do not use highly concentrated detergents. They may cause malfunction. Do not use high-pressure water spray in excess of the specifications.
Surface Temperature
Burn injury may occur. The Sensor surface temperature rises depending on application conditions, such as the surrounding temperature and the power supply voltage. Use caution when operating or washing the Sensor.
Precautions for Safe Use
Do not install the Sensor in the following locations.
(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3)Locations subject to corrosive gas
(4) Locations where the Sensor may receive direct vibration or shock
Connecting and Mounting
(1) The maximum power supply voltage is 30 VDC. Before turning the power ON, make sure that the power supply voltage does not exceed the maximum voltage.
(2)Laying Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a separate conduit or use shielded cable.
(3) Use an extension cable with a minimum thickness of 0.3 mm^2 and less than 100 m long.
(4) Do not pull on the cable with excessive force.
(5) Pounding the Photoelectric Sensor with a hammer or other tool during mounting will impair water resistance. Also, use M3 screws.
(6) Mount the Sensor either using the bracket (sold separately) or on a flat surface.
(7) Be sure to turn OFF the power supply before inserting or removing the connector.
Cleaning
Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved.
Power Supply
If a commercial switching regulator is used, ground the FG (frame ground) terminal.
Power Supply Reset Time
The Sensor will be able to detect objects 100 ms after the power supply is tuned ON. Start using the Sensor 100 ms or more after turning ON the power supply. If the load and the Sensor are connected to separate power supplies, be sure to turn ON the Sensor first.
Turning OFF the Power Supply
Output pulses may be generated even when the power supply is OFF. Therefore, it is recommended to first turn OFF the power supply for the load or the load line.
Load Short-circuit Protection
This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. Be sure to not use an output current flow that exceeds the rated current. If a load short circuit occurs, the output will turn OFF, so check the wiring before turning ON the power supply again. The short-circuit protection circuit will be reset. The load shortcircuit protection will operate when the current flow reaches 1.8 times the rated load current. When using an L load, use an inrush current of 1.8 times the rated load current or higher.
Water Resistance
Do not use the Sensor in water, rainfall, or outdoors.
When disposing of the Sensor, treat it as industrial waste.
Mounting Diagram
Use a mounting torque of 0.5 N·m max.

Resistance to Detergents, Disinfectants, and Chemicals
- Performance is assured for typical detergents and disinfectants, but performance may not be maintained for some detergents and disinfectants. Refer to the following table when using these agents.
- The E3ZM passed testing for resistance to detergents and disinfectants performed using the items in the following table. Refer to this table when considering use of detergents and disinfectants.
| Category | Product name | Concen- tration | Temper- ature | Time |
| Chemical | Sodium hydroxide (NaOH) | 1.5 % | 70 °C | 240 h |
| Potassium hydroxide (KOH) | 1.5 % | 70 °C | 240 h | |
| Phosphoric acid \( \left( {{\mathrm{H}}_{3}{\mathrm{{PO}}}_{4}}\right) \) | 2.5 % | 70 °C | 240 h | |
| Sodium hypochlorite (Na- CIO) | 0.3 % | 25 °C | 240 h | |
| Hydrogen peroxide \( \left( {{\mathrm{H}}_{2}{\mathrm{O}}_{2}}\right) \) | 6.5 % | 25 °C | 240 h | |
| Alkaline foam detergent | P3-topax-66s (Manufactured by Ecolab) | 3.0 % | 70 °C | 240 h |
| Acidic foam detergent | P3-topax-56 (Manufactured by Ecolab) | 5.0 % | 70 °C | 240 h |
| Disinfectant | P3-oxonia active 90 (Manufactured by Ecolab) | 1.0 % | 25 °C | 240 h |
| TEK121 (Manufactured by ABC Compounding) | 1.1 % | 25 °C | 240 h |
Note: The Sensor was immersed in the chemicals, detergents, and disinfectants listed above at the temperatures in the table for 240 hours and then passed an insulation resistance of 100M min.
Sensors
Through-beam Models
Pre-wired Models
E3ZM-T61(-G0)
E3ZM-T81(-G0)
E3ZM-T63(-G0)
E3ZM-T83(-G0)


Emitter

4-dia. vinyl-insulated round cable with 2 or 3 conductors (Conductor cross section:
0.2mm^2 Insulator diameter: 1.1mm
Standard length: 2m

Receiver


4-dia, vinyl-insulated round cable with 3 conductors (Conductor cross section 0.2mm^2 Insulator diameter:1.1 mm), Standard length:2 m
M12 Pre-wired Connector (E3ZM-□□□-M1J

| Terminal No. | Specifications |
| 1 | +V |
| 2 | Light emission stop input (-G0 only) |
| 3 | 0V |
| 4 | --- |
M12 Pre-wired Connector (E3ZM-□□□-M1J

| Terminal No. | Specifications |
| 1 | +V |
| 2 | --- |
| 3 | 0V |
| 4 | Output |
Through-beam Models
Standard Connector
E3ZM-T66(-G0)
E3ZM-T86(-G0)
E3ZM-T68(-G0)
E3ZM-T88(-G0)


Receiver



| Terminal No. | Specifications |
| 1 | +V |
| 2 | Light emission stop input (-G0 only) |
| 3 | 0V |
| 4 | --- |

Receiver



| Terminal No. | Specifications |
| 1 | +V |
| 2 | --- |
| 3 | 0V |
| 4 | Output |
Retro-reflective Models
Pre-wired Models
E3ZM-R61
E3ZM-R81
Diffuse-reflective Models
Standard Connector
E3ZM-D62
E3ZM-D82




4-dia. vinyl-insulated round cable with
3 conductors (Conductor cross section
0.2mm^2 Insulator diameter: 1.1mm
Standard length: 2m
M12 Pre-wired Connector
(E3ZM-□□□-M1J

| Terminal No. | Specifications |
| 1 | +V |
| 2 | --- |
| 3 | 0V |
| 4 | Output |
Retro-reflective Models
Pre-wired Models
E3ZM-R66
E3ZM-R86
Diffuse-reflective Models
Standard Connector
E3ZM-D67
E3ZM-D87





| Terminal No. | Specifications |
| 1 | +V |
| 2 | --- |
| 3 | 0V |
| 4 | Output |
BGS Reflective Models
Pre-wired Models
E3ZM-LS61H
E3ZM-LS62H
E3ZM-LS64H
E3ZM-LS81H
E3ZM-LS82H
E3ZM-LS84H




4-dia. vinyl-insulated round cable with
4 conductors (Conductor cross section:
0.2mm^2 Insulator diameter: 1.1mm
Standard length: 2m
M12 Pre-wired Connector
(E3ZM-□□□-M1J

| Terminal No. | Specifications |
| 1 | +V |
| 2 | Operation selection |
| 3 | 0V |
| 4 | Output |
BGS Reflective Models
Standard Connector
E3ZM-LS66H
E3ZM-LS67H
E3ZM-LS69H
E3ZM-LS86H
E3ZM-LS87H
E3ZM-LS89H





| Terminal No. | Specifications |
| 1 | +V |
| 2 | Operation selection |
| 3 | 0V |
| 4 | Output |
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTIBILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTYES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
- Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
- Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
- Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLEPRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Cat. No. E369-E2-01-X
In the interest of product improvement, specifications are subject to change without notice.
OMRON EUROPE B.V.
Wegalaan 67-69,
NL-2132 JD, Hoofddorp,
The Netherlands
Phone: +31 23 568 13 00
Fax: +31 23 568 13 88
www.eu.omron.com