TEFAL Intense Pur Air PU6075 - Air purifier

Intense Pur Air PU6075 - Air purifier TEFAL - Free user manual and instructions

Find the device manual for free Intense Pur Air PU6075 TEFAL in PDF.

📄 18 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice TEFAL Intense Pur Air PU6075 - page 5
View the manual : English EN 한국어 KO
Pick your language and provide your email: we'll send you a specifically translated version.
TypeAir purifier
BrandTefal
ModelIntense Pur Air PU6075
Filtration levels4: Pre-filter, Active carbon filter, HEPA filter, NanoCaptur filter
Filtration efficiencyUp to 99.97% of fine particles (PM2.5), pollen, dust mites, animal allergens, mold, bacteria/viruses; captures formaldehyde
SensorsInfrared particle sensor and gas sensor
ModesAuto Day, Auto Night, Boost, Silent
Additional functionsIonizer, Timer/Delayed start (1/2/4/8 h), Control panel lock, Adjustable air outlet grid (3D Pure Air)
Air quality indicatorColor-coded: Blue (excellent), Purple (average), Red (poor)
Filter replacement indicatorsSeparate lights for pre-filter cleaning, active carbon filter replacement, HEPA filter replacement, NanoCaptur filter check
Pre-filter maintenanceClean every 2–4 weeks (vacuum or wash with water)
Active carbon filter replacementEvery 12 months (part no. XD6061)
HEPA filter replacementEvery 3 years (part no. XD6071)
NanoCaptur filter replacementBased on color change indicator; check every 6 months (part no. XD6081)
Sensor cleaningEvery 2 months: clean particle sensor lens with cotton swab, gas sensor with soft brush
Power supplyClass II double insulation; voltage, frequency, and power must suit local supply
Safety featuresAuto shut-off if front door not correctly assembled; child lock
Installation clearanceAt least 50 cm from walls, curtains, or other obstacles on each side
WarrantyInternational warranty through Tefal/Rowenta service centers

Frequently Asked Questions - Intense Pur Air PU6075 TEFAL

How often should I clean the pre-filter?
The pre-filter should be cleaned every 2 to 4 weeks using a vacuum cleaner or by washing with water. Ensure it is completely dry before reinstalling.
How do I replace the HEPA filter?
Turn off and unplug the appliance. Open the front door and remove the old HEPA filter. Insert the new HEPA filter (ref. XD6071) and close the door. Then press and hold the reset button for 2 seconds to reset the filter indicator.
What does the air quality indicator color mean?
The indicator shows: Blue = excellent air quality, Purple = average, Red = poor air quality. If the indicator does not match perceived air quality, you can adjust the sensor sensitivity.
How do I set the timer?
When the appliance is on, briefly press the timer button (11) to select 1, 2, 4, or 8 hours; the appliance will turn off automatically after that time. When off, press the same button to set a delayed start in 1, 2, 4, or 8 hours.
How do I activate the ionizer?
Briefly press the ionizer button (10) to activate or deactivate the negative ion release function. The ionizer is off by default.
What should I do if the air flow is weak?
Check if the filters need cleaning or replacement. The pre-filter may be clogged or the HEPA/active carbon filter may be saturated. Also ensure that the air inlets and outlet are not blocked and that the appliance is placed with at least 50 cm clearance.
How do I adjust the sensor sensitivity?
Turn off the appliance. Hold down the filtration speed setting button (12) for 2 seconds. Then briefly press the same button to cycle through low, medium, and high sensitivity. The new setting is saved after 10 seconds of inactivity.
Why does my appliance not start?
Check that the power cord is connected and the front door is properly closed (the appliance has a safety interlock). Also ensure there is no power outage. If all else fails, contact an approved service center.
How do I reset the filter indicator after replacement?
After replacing a filter, press and hold the reset button (8) for 2 seconds. If you replaced a filter before its end of life, enter forced reset mode by holding reset for 2 seconds, then briefly press to select the filter type, then hold reset again for 2 seconds.
Can I wash the HEPA or NanoCaptur filters?
No. Only the pre-filter can be washed with water. The HEPA, active carbon, and NanoCaptur filters are not washable and must be replaced when exhausted.

User questions about Intense Pur Air PU6075 TEFAL

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air purifier in PDF format for free! Find your manual Intense Pur Air PU6075 - TEFAL and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Intense Pur Air PU6075 by TEFAL.

USER MANUAL Intense Pur Air PU6075 TEFAL

INTENSEPUREAIRPU6075K0

www.tefal.com

EN

Please read the instruction manual and safety instructions carefully before using the appliance and keep the instruction manual for reference. For your safety, this appliance complies with all applicable standards and regulations (Low Voltage, Electromagnetic Compatibility, Environmental directives etc.).

KO

natural_image Line drawing of a hand inserting a device into a large air purifier (no text or symbols)

TEFAL Intense Pur Air PU6075 - KO - 1

natural_image Illustration of hands installing or adjusting a grid-patterned air conditioner unit (no text or symbols visible)

Step-by-step diagram showing a device being processed, labeled 3 to 6 with directional arrows indicating movement.

CLICK! CLICK! ⑦

TEFAL Intense Pur Air PU6075 - KO - 4

natural_image Illustration of a hand inserting a fan into a power heater (no text or symbols visible)

TEFAL Intense Pur Air PU6075 - KO - 5

natural_image Illustration of a hand inserting a filter into a power plant (no text or symbols visible)

CLICK !CLICK !

CLICK! 1112

CLICK!

필터분리 및 설치

SAFETY INSTRUCTIONS

  • Before use, always check that the appliance, plug and power cord are in good condition.
  • The appliance must be used in normal conditions of use as defined in this notice.
  • Never allow any liquid to get into the appliance.
  • Do not touch the appliance with wet hands.
  • Never insert objects into the appliance (e.g. needles, etc.).
  • Do not cover your appliance.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Your appliance must be unplugged before any maintenance.
  • For maintenance and adjustment operations, please refer to the "Maintenance" section.
  • Ensure that the air purifier is switched off from the supply mains before removing the guard.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.

RECOMMENDATIONS

The electrical facilities of the room, as well as the installation and use of the appliance must comply with the standards in force in your country.

Do not use your appliance near inflammable objects or products. In general, you should always place the appliance at least 50 cm away from any object (walls, curtains, aerosols, etc.).

Never place anything on the appliance.

Do not pull on the power cord or the appliance, even when unplugging it from a wall socket.

This appliance is designed for indoor domestic household use only. In case of professional use, inappropriate use or failure to comply with the instructions, the manufacturer accepts no responsibility and the guarantee does not apply.

Always unroll the power cord completely before use.

Do not use the appliance in a dusty room or a location where there is a risk of fire.

This appliance must not be used in a humid environment.

Never use the appliance close to a heat source.

The warranty will be invalidated if damage occurs due to incorrect use.

Do not cover the air inlets or the outlet grid.

Never use the appliance in an inclined or horizontal position. Place the appliance on a flat, stable surface.

In the case of prolonged absence: switch the appliance off using the button (9) and unplug it.

DESCRIPTION

Product description

A Air quality indicator

B Adjustable air outlet grid

C Control panel

D Front door

E Handle

F Air inlets

G Particle sensor

H Gas sensor

Power cord outlet

Control panel lights

1 Locked control panel

2 Filter change indicator

3 lonizer function

4 Timer / delayed start

5 Mode display Auto Day / Auto Night / Boost / Silent modes

Control buttons

6 Light

7 Control Panel Lock

8 Filter reset

9 Start

10 lonizer function

11 Timer / delayed start setting

12 Automatic modes / filtration speed selection

OPERATING PRINCIPLE

The new Intense Pure Air purifier from Tefal enables you to breathe up to 99.97% pure air in your home and protects your health with 4 filtration levels as described below. Each level is essential and traps characteristic pollutants:

LEVEL 3:

HEPA FILTER

  • Fine particles (PM2.5)
  • Pollen
  • Dust mites
    • Animal allergens
    • Mold
  • Bacteria / viruses

LEVEL 4:

NANOCAPTUR FILTER

- Formaldehyde

TEFAL Intense Pur Air PU6075 - LEVEL 4: - 1

LEVEL 1:

PRE-FILTER

• Dust
- Hair
• Fur
• Lint

LEVEL 2:

ACTIVE CARBON FILTER

• Volatile organic components (VOCs)
- Odors / gases

TEFAL Intense Pur Air PU6075 - LEVEL 2: - 1

« HOW TO ACHIEVE CLEANER INDOOR AIR »

In addition to using your Intense Pure Air purifier, here are some tips on how to improve the quality of your indoor air:

  • Ventilate the rooms for at least 10 min. every day, in summer and winter.
  • Maintain your ventilation system.
  • Limit the use of household products.
  • Do not smoke indoors.
  • Avoid home fragrances, incense sticks, scented candles, etc.
  • Ventilate whenever any work is being conducted in your home and for several weeks afterwards.
  • Avoid green plants that are allergenic or need frequent watering.

WHERE TO INSTALL THE APPLIANCE

Place the purifier on a flat, stable surface in the room requiring treatment.

To allow the air to circulate freely, avoid placing the appliance behind curtains, below a window, item of furniture or shelf unit, or close to any other obstacle, and leave at least 50 cm of free space on each side of the appliance.

BEFORE USING THE APPLIANCE FOR THE FIRST TIME

Make sure that the plastic packaging protecting the filters has been removed before using the appliance.

Before the first use, ensure the voltage, frequency and power of your appliance suit your electric supply.

Your appliance can operate using an unearthed plug. It is a class II (double electrical insulation). Before switching on your appliance, ensure that:

Before switching on your appliance, ensure that.

  • the appliance is completely assembled as described in the safety instructions,
  • the appliance is placed on a stable, horizontal surface,
  • the appliance is positioned in accordance with the instructions given in this manual,
  • the air inlets and the oultet grid are completely unobstructed,
  • the 4 filters and front panel have been correctly installed (See section "Disassembling/Reassembling filters").

IMPORTANT: You are advised to switch off and unplug the appliance when not in use.

This appliance is equipped with a device that automatically prevents it from operating if the front door is not correctly assembled.

Inserting and replacing the filters

This appliance is equipped with 4 types of filters:

TEFAL Intense Pur Air PU6075 - Inserting and replacing the filters - 1

natural_image Four identical black-and-white grid panels arranged in a 2x2 grid, each with a side bracket (no text or symbols visible)

TEFAL Intense Pur Air PU6075 - Inserting and replacing the filters - 2

natural_image Close-up of a hexagonal grid pattern with a small white dot in the center (no text or symbols)

TEFAL Intense Pur Air PU6075 - Inserting and replacing the filters - 3

natural_image Close-up of a rectangular electronic component with grid pattern and mounting holes (no visible text or symbols)

TEFAL Intense Pur Air PU6075 - Inserting and replacing the filters - 4

natural_image Geometric octagonal pattern composed of interconnected rectangular segments forming a circular center (no text or symbols)

Pre-filter Active carbon filter NanoCaptur filterHEPA filter

NB: For optimum performance of the appliance, only use filters provided by TEFAL.

To replace the filters, follow the instructions in the section "Disassembling/Reassembling filters".

Please note: certain filters may emit a temporary slight odour, due to the transport and storage conditions.

SWITCHING THE APPLIANCE ON

Connect the power cord and press the start button (9).

Your appliance will be preset to automatic mode the first time you turn it on.

Thanks to its infrared particle sensor and its gas sensor, it detects the level of pollution in the room and automatically adjusts the filtration speed accordingly in auto day for auto night mode.

The air quality indicator changes color to indicate the air quality in the room.

Air quality Air quality indicator color
Excellent Blue
Average Purple
Poor Red

EN

Setting the pollution sensors

The appliance is preset to medium sensitivity.

If the air quality indicator remains:

- poor after 2 hours in operation although the air seems to be purified - excellent for more than 1 hour although the air seems to be polluted

you can adjust the sensor sensitivity as follows:

  1. When the air purifier is off, hold down the filtration speed setting button for 2 seconds:

TEFAL Intense Pur Air PU6075 - Setting the pollution sensors - 1

  1. Set the sensitivity by briefly pressing the filtration speed setting button:

TEFAL Intense Pur Air PU6075 - Setting the pollution sensors - 2

TEFAL Intense Pur Air PU6075 - Setting the pollution sensors - 3 + Blue + Purple + RedTEFAL Intense Pur Air PU6075 - Setting the pollution sensors - 4TEFAL Intense Pur Air PU6075 - Setting the pollution sensors - 5
Low sensitivity Medium sensitivity High sensitivity
  • Select high sensitivity if the air purifier indicates excellent air quality for more than 1 hour although the air seems to be polluted.
  • Select low sensitivity if the air purifier continues to indicate poor air quality even though it has been operating for more than 2 hours and the air seems sufficiently purified.

  • The new setting is applied if no button is pressed for 10 seconds.

OPERATION

TEFAL Intense Pur Air PU6075 - OPERATION - 1

Start

Briefly press this button to switch the air purifier on or off.

TEFAL Intense Pur Air PU6075 - Start - 1

Mode / filtration speed selection

TEFAL Intense Pur Air PU6075 - Mode / filtration speed selection - 1

Auto day

Automatic: In this operating mode, the filtration speed automatically adjusts according to the air quality detected by the particle sensor and the gas sensor. This mode is recommended for general use.

TEFAL Intense Pur Air PU6075 - Auto day - 1

Auto Night

The filtration speed of your appliance is adjusted for a whisper quiet air flow during the night. The light intensity of the appliance is also reduced. If pollution is detected, the filtration speed increases slightly to purify your air but remains quiet to avoid disturbing your sleep.

TEFAL Intense Pur Air PU6075 - Auto Night - 1

Boost mode

The highest speed level of filtration.

TEFAL Intense Pur Air PU6075 - Boost mode - 1

Silent mode

The whisper quiet speed.

TEFAL Intense Pur Air PU6075 - Silent mode - 1

Light

You can change the light intensity of the appliance as you wish or according to the time of day.

Press Air quality indicator Control panel
1 Light upLight up
2 Moderatelight Moderate light
3 Off Moderatelight

TEFAL Intense Pur Air PU6075 - Light - 1

Ionizer function

The ionizer function releases negative ions into the air. This function is switched off by default. To activate it, briefly press button 10.

TEFAL Intense Pur Air PU6075 - Ionizer function - 1

Timer / delayed start

If the appliance is on: you can use this button to define the operating duration. Briefly press the button to select the number of operating hours desired (1, 2, 4 or 8) and the appliance will automatically turn off at the end of the selected period.

If the appliance is off: briefly press the button to set the appliance to turn on in a certain number of hours (1, 2, 4 or 8).

3D pure air function (adjustable grid)

You can adjust the position of the air outlet grid manually, as desired. For an optimum, even flow of purified air in the room, set the angle to 45^ ; for maximum comfort, set the angle to 90^ .

TEFAL Intense Pur Air PU6075 - 3D pure air function (adjustable grid) - 1

Control Panel Lock

The lock system prevents the purifier from being accidentally mis-set during operation.

To activate it, press the button (7) for 3 sec until the locked control panel indicator turns on. To exit this mode, press the button (7) again for 3 seconds, until the indicator turns off. When selected, the other buttons are locked.

MAINTENANCE

Always switch the appliance off with the button (9) and unplug it before conducting any maintenance operation.

You can clean the appliance with a slightly damp cloth.

IMPORTANT: Never use abrasive products which could damage your appliance's appearance.

Filters

Filter Action Cycles
Pre-filter Clean Every 2 to 4 weeks
Active carbon filter Replace Every12 months
HEPA filter Replace Every 3 years
NanoCaptur filter ReplaceColor changing(see Color chart on filter)

This data is based on an average use of around 8 hours per day at lowest speed of Auto Day Mode. The recommended frequency for cleaning and replacing the filters may vary depending on the duration of use and the operating environment.

  • The light indicates when the pre-filter needs cleaning.
  • The right indicates when the active carbon filter needs replacing.
  • The light indicates when the HEPA filter needs replacing.
  • The light indicates when the color of the NanoCaptur filter needs checking.

- The NanoCaptur filter contains translucent granules which change color according to the formaldehyde absorption rate. Refer to the color chart on the inside of the panel or the filter itself to establish the filter saturation rate. Once the saturation rate has reached its maximum, the filter must be replaced. You have to check the filter saturation rate every six months.

- The pre-filter can be re-used: remove the dust using a vacuum cleaner or wash with water.

CAUTION:

The appliance's efficiency can be reduced if the pre-filter is not cleaned regularly. Never use a pre-filter that is still damp.

EN

The pre-filter is the only filter which can be re-used and washed with water. The HEPA, NanoCaptur and active carbon filters cannot be cleaned and re-used. Never wash with water.

To replace the filters, follow the instructions in the section "Disassembling/Reassembling filters".

Your replacement filters are available under the following codes:

Filter Code PU6075
HEPA filter XD6071
Active carbon filter XD6061
NanoCaptur filter XD6081

IMPORTANT: Resetting the filters

The reset light flashes when a filter needs to be replaced. Once the filter has been replaced, hold down the reset

button for 2 seconds

Forced reset:

If you have replaced a filter before its end of life, force the reset of the filter replacement cycle:

  1. Hold the reset button for 2 seconds
  2. Press the reset button briefly to select the filter you have changed.
  3. After selecting the filter to reset, hold the reset button for 2 seconds. The electronic meter is then reset.
  4. If no button is activated for 10 seconds in forced reset mode, the reset mode is canceled.

TEFAL Intense Pur Air PU6075 - Forced reset: - 1

TEFAL Intense Pur Air PU6075 - Forced reset: - 2

  • Avoid handling used filters if you suffer from allergies or asthma.
  • Wear gloves when changing the filters, or wash your hands well afterwards.
  • Put used filters directly into a closed, air-tight bag before throwing them away to avoid spreading pollutants.

Pollution sensors

The particle sensor and gas sensor need to be cleaned regularly (every 2 months) and appropriately. Make sure you turn off and unplug the appliance before cleaning the pollution sensors and follow the recommendations below:

  1. Clean the air inlet and outlet using a soft brush or cloth.
  2. Open the sensor cover located on the right-hand side of the appliance.
  3. Lightly wet a cotton swab and remove any dust from the lens and the inlet/outlet. Wipe using a dry cotton swab.
  4. Clean the gas sensor using a soft brush or vacuum cleaner.

OIL MINT ①

TEFAL Intense Pur Air PU6075 - Pollution sensors - 2

natural_image Line drawing of a hand holding a small blood glucose meter, no text or symbols present

TEFAL Intense Pur Air PU6075 - Pollution sensors - 3

natural_image Line drawing of a hand holding a small object near a vertical line, with number 3 and a circled number 3 nearby (no text or symbols on the object itself)

SODA RADIANCE ④

IMPORTANT:

Never use a detergent or metal object to clean the sensors.

The efficiency of the sensors may be reduced if not cleaned regularly.

Cleaning frequency varies depending on the operating environment of the appliance. If it is used in a dusty environment, clean the sensors more frequently.

STORAGE

When you are not using the appliance, store it in a cool, dry place.

IN THE EVENT OF A PROBLEM

  • Do not disassemble the appliance yourself. A poorly repaired appliance may be dangerous for the user.
  • Check the troubleshooting table below before contacting an Approved Service Center:

Problem Check Solution

The appliance will not switch on.Is the power cord connected?Connect the power cord to a plug with the correct voltage.
Are all the display elements off?Press the start button and select the required function.
Is there a power outage?You can use your purifier once the power turns on again.
Is the front door closed? Close the front door properly.
The air flow does not change automatically.Is the appliance in Silent or Boost mode?Select the correct operating mode Auto day or Auto night.
The flow is a lot weaker than before.Does the filter need to be cleaned or replaced?Check the filter cleaning and replacement frequencies and clean/replace the filter(s) if necessary.
There is an unpleasant smell coming from the air outlet.Is the sensor lens covered with dust?Check the filter cleaning and replacement frequencies and clean/replace the filter(s) if necessary.
The air quality indicator does not change color.Does the light still indicate poor air quality?Clean the sensor lens.
Does the indicator still indicate poor air quality?Set the sensor sensitivity to "low" or "medium".
Does the indicator indicate excellent air quality?Set the sensor sensitivity to "high" or "medium".

WARRANTY

Do not use the appliance and contact an Approved Service Centre if:

- your appliance has been dropped;

- your appliance or its power cord are damaged;

- your appliance no longer functions properly.

You can find a list of Approved Service Centres on the ROWENTA and TEFAL international warranty cards.

HELP PROTECT THE ENVIRONMENT!

TEFAL Intense Pur Air PU6075 - HELP PROTECT THE ENVIRONMENT! - 1

TEFAL Intense Pur Air PU6075 - HELP PROTECT THE ENVIRONMENT! - 2

Your appliance contains many materials which can be recovered or recycled.

Take it to a collection point or an approved service centre for processing.

If this appliance uses batteries: help us look after the environment, by not throwing away your used batteries. Instead, bring them to anyone of the special battery collection points. Do not throw them away with your household waste.

These instructions can also be found on our internet site, at www.rowenta.com and www.tefal.com.

안전 지침

natural_image Four-panel grid solar panel with mounting brackets (no text or symbols visible)

프리필터 액티브카본 필터 나노 캡쳐
TEFAL Intense Pur Air PU6075 - 안전 지침 - 1

natural_image Close-up of a hexagonal grid pattern with a small white cutout on the left side (no text or symbols)

TEFAL Intense Pur Air PU6075 - 안전 지침 - 2

natural_image Close-up of a rectangular solar panel with grid lines and a small hole, no visible text or symbols

헤파필터

TEFAL Intense Pur Air PU6075 - 안전 지침 - 3

natural_image Geometric octagonal diagram with concentric circles and radial segments, no text or symbols present

(Nanocaptur)필터

2

TEFAL Intense Pur Air PU6075 - 안전 지침 - 5

natural_image Line drawing of a hand holding a small object near a vertical line, with number 3 in the corner (no text or symbols on the object itself)

Diagram showing a hand holding a pen near a small bottle with a digital display, labeled with number 4.

중요사항:

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : TEFAL

Model : Intense Pur Air PU6075

Category : Air purifier