| Product Type | Air Purifier |
| Brand | Tefal |
| Model | Intense Pure Air PU4015 |
| Colour | White |
| Dimensions (H x W x D) | 700 x 420 x 260 mm |
| Weight | 8.5 kg |
| Power Supply | 220-240 V, 50 Hz |
| Power Consumption | 55 W (max) |
| Noise Level (min-max) | 20 - 55 dB(A) |
| Coverage Area (max) | 80 m² |
| CADR (Clean Air Delivery Rate) | 250 m³/h |
| Filtration System | Pre-filter, HEPA H13, Activated Carbon |
| Number of Fan Speeds | 3 + Auto mode |
| Timer Settings | 1, 2, 4, 8 hours |
| Air Quality Sensor | PM2.5 and VOC sensor |
| Filter Replacement Indicator | Yes |
| Night Mode | Yes, ultra-silent operation |
| Child Lock | Yes |
| Control Type | Touch panel |
| Casing Material | Plastic (ABS) |
| Filter Maintenance | Replace every 6-12 months |
| Energy Efficiency Class | A (EU) |
| Spare Parts Available | Replacement filters (reference: XD6000) |
| Warranty | 2 years (EU) |
Frequently Asked Questions - Intense Pure Air PU4015 TEFAL
User questions about Intense Pure Air PU4015 TEFAL
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Air purifier in PDF format for free! Find your manual Intense Pure Air PU4015 - TEFAL and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Intense Pure Air PU4015 by TEFAL.
USER MANUAL Intense Pure Air PU4015 TEFAL
INTENSEPUREAIRPU4015/PU6015
www.tefal.com



DISASSEMBLING/REASSEMBLING FILTERS









拆卸/重新安装滤网 - 초기 필터분리 및 설치 - فك وتركيب الفترات
DESCRIPTION
Product description
| A Ambient light (model PU6015 only) |
| B Adjustable air outlet grid |
| C Control panel |
| D Front door |
| E Handle |
| F Air inlets |
| G Power cord outlet |
Control panel Lights
| 1 Filter replacement indicator |
| 2 Filtration speed |
| 3 Timer / delayed start |
| 4 Ionizer function |
Control buttons
| 5 Light |
| 6 Filter reset |
| 7 Start |
| 8 Filtration speed selection |
| 9 Timer / delayed start setting |
| 10 Ionizer function |
Read the instructions for use and safety carefully before use and keep them for future reference.
SAFETY TIPS
It is essential that you read these instructions carefully and observe the following recommendations:
- For your safety, this appliance complies with the applicable standards and regulations (low voltage, electromagnetic compatibility, environmental directives, etc.).
- This appliance should not be used by persons (including children) with reduced physical, sensory or mental capacities or lack of experience and knowledge, unless they are supervised or have been given instructions beforehand concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure they do not play with the appliance.
- The appliance can be used by children aged 8 and over and persons with a lack of experience or knowledge or reduced physical, sensory or mental capacities, provided they are supervised, have been trained on the safe use of the appliance and are aware of the risks involved. Children must not play with the appliance.
- If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or a similarly qualified person so as to avoid any danger.
- Children should not clean or perform maintenance on the appliance without being supervised.
- For maintenance operations, please refer to the "Maintenance" section.
- Keep the appliance and its power cord out of the reach of children aged under 8.
- This appliance is designed for domestic use only. It should not be used for industrial purposes.
- The warranty will be invalidated if damage occurs due to incorrect use.
- Do not operate this appliance in a very dusty and/or humid place or in a location with fire hazards.
- Before use, always make sure that the appliance, plug and power cord are in good condition.
- Never insert objects into the appliance (e.g. needles, etc.).
- Do not pull on the power cord or the appliance, even to unplug it from the wall power outlet.
- Unroll the full length of the cord before use.
VERY IMPORTANT
Do not cover the air inlets or the outlet grid.
Do not touch the appliance with wet hands.
Never allow any liquid to enter the appliance.
Never use the appliance in a humid place.
Never use the appliance close to a heat source.
Never place anything on the appliance or insert anything into it.
Do not use the appliance close to flammable objects or products (curtains, aerosols, solvents, etc.).
Never use the appliance in an inclined or horizontal position. Place the appliance on a flat, stable surface.
In the case of prolonged absence: switch the appliance off using the button (7) and unplug it.
Switch off and unplug your appliance before moving it.
Unplug the air purifier during assembly and cleaning.
EN
OPERATING PRINCIPLE
The new Intense Pure Air purifier from Tefal enables you to breathe up to 99.97% pure air in your home and protect your health with 4 filtration levels as described below. Each level is essential and traps characteristic pollutants:
LEVEL 3:
HEPA FILTER
• Fine particles (PM2.5)
- Pollen
- Dust mites
• Animal allergens
• Mold
- Bacteria / viruses
LEVEL 4:
NANOCAPTUR FILTER
- Formaldehyde


LEVEL 1:
PRE-FILTER
• Dust
- Hair
• Fur
• Lint
LEVEL 2:
ACTIVE CARBON FILTER
• Volatile organic components (VOCs)
- Odors / gases

« HOW TO ACHIEVE CLEANER INDOOR AIR »
In addition to using your Intense Pure Air purifier, here are some tips on how to improve the quality of your indoor air:
- Ventilate the rooms for at least 10 min. every day, in summer and winter
- Maintain your ventilation system
- Limit the use of household products
- Do not smoke indoors
- Avoid home fragrances, incense sticks, scented candles, etc.
• Ventilate whenever any work is being conducted in your home and for several weeks afterwards - Avoid green plants that are allergenic or need frequent watering
WHERE TO INSTALL THE APPLIANCE
Place the purifier on a flat, stable surface in the room requiring treatment.
To allow the air to circulate freely, avoid placing the appliance behind curtains, below a window, item of furniture or shelf unit, or close to any other obstacle, and leave at least 50 cm of free space on each side of the appliance.
BEFORE USING THE APPLIANCE FOR THE FIRST TIME
Make sure that the plastic packaging protecting the filters has been removed before using the appliance.
Also make sure that:
• The voltage of your electrical installation corresponds to the one indicated on the appliance.
Your appliance can be used with a power plug without an earth connection. It is a class II appliance (double electrical insulation),
• The appliance is positioned in the house as described above,
• The air inlet and outlet grids are completely unobstructed,
- Ensure the 4 filters and front panel have been correctly installed (See section "Disassembling/Reassembling filters").
This appliance is fitted with a device that automatically prevents it from operating if the front door is not correctly assembled.
Inserting and replacing the filters
This appliance is equipped with 4 types of filters:

Pre-filter Active carbon filter NanoCaptur


HEPA filter

filter
NB: For optimum performance of the appliance, only use filters provided by TEFAL.
To replace the filters, follow the instructions in the section "Disassembling/Reassembling filters".
Please note: certain filters may emit a temporary slight odour, due to the transport and storage conditions.
SWITCHING THE APPLIANCE ON
Connect the power cord and press the start button (7).
When you switch your appliance on, it will be automatically set to speed 2, the optimum operating speed.
OPERATION
Start

Briefly press this button to switch the air purifier on or off.
Mode/filtration speed selection

This appliance has 4 filtration speeds. You can change these speeds as you wish or according to the time of day.
- Speed 1 is specially adapted for nighttime operation – for whisper-quiet air purification.
- Speed 2 is the optimum operating speed, combining performance and quietness.
- Speeds 3 and 4 purify the air faster, for times when pollution levels are high.
Light

You can change the light intensity of the appliance as you wish or according to the time of day.
| Press Ambient light (PU6015 only) Control panel | ||
| 1 Light up Light up | ||
| 2 Moderate light Moderate light | ||
| 3 (model PU6015 only) | Off Moderate light | |
Ionizer function

The ionizer function releases negative ions into the air. This function is switched off by default. To activate it, briefly press button 10.
Timer / delayed start

If the appliance is on: you can use this button to define the operating duration. Briefly press the button to select the number of operating hours desired (1, 2, 4 or 8) and the appliance will automatically turn off at the end of the selected period.
If the appliance is off: briefly press the button to set the appliance to turn on in a certain number of hours (1, 2, 4 or 8).
3D pure air function (adjustable grid)
You can adjust the position of the air outlet grid manually, as desired. For an optimum, even flow of purified air in the room, set the angle to 45° ; for maximum comfort, set the angle to 90° .
MAINTENANCE
Always switch the appliance off with the button (7) and unplug it before conducting any maintenance operation.
You can clean the appliance with a slightly damp cloth.
IMPORTANT: Never use abrasive products which could damage your appliance's appearance.
Filters
| Filter Action Cycles | ||
| Pre-filter Clean Every 2 to 4 weeks | ||
| Active carbon filter Replace Every | 12 months | |
| HEPA filter Replace Every 3 years | ||
| NanoCaptur filter Replace | Color changing(see Color chart on filter) | |
This data is based on an average use of 8 hours per day at speed 2.
The recommended frequency for cleaning and replacing the filters may vary depending on the duration of use and the operating environment.
- A "HEPA" light indicates when the HEPA filter needs to be replaced.
The 'Odor' light display indicates when the carbon filter needs replacing.
- The NanoCaptur filter contains translucent granules which change color according to the formaldehyde absorption rate. Refer to the color chart on the inside of the panel or the filter itself to establish the filter saturation rate.Once the saturation rate has reached its maximum, the filter must be replaced. You have to check the filter saturation rate every six months.
- The pre-filter can be re-used: remove the dust using a vacuum cleaner or wash with water.
CAUTION:
The appliance's efficiency can be reduced if the pre-filter is not cleaned regularly.
Never use a pre-filter that is still damp.
The pre-filter is the only filter which can be re-used and washed with water. The HEPA, NanoCaptur and active carbon filters cannot be cleaned and re-used. Never wash with water.
To replace the filters, follow the instructions in the section "Disassembling/Reassembling filters".
Your replacement filters are available under the following codes:
| Filter Code PU4015 Code PU6015 | ||
| HEPA filter | XD6070 | XD6071 |
| Active carbon filter | XD6060 | XD6061 |
| NanoCaptur filter | XD6080 | XD6081 |
IMPORTANT: Resetting the filters
The reset light flashes when a filter needs to be replaced. Once the filter has been replaced, hold down the reset
button for 2 seconds.
Forced reset:
If you have replaced a filter before its end of life, force the reset of the filter replacement cycle:

- Hold the reset button for 2 seconds.
- Press the reset button briefly to select the filter you have changed.
- After selecting the filter to reset, hold the reset button for 2 seconds. The electronic meter is then reset.
- If no button is activated for 10 seconds in forced reset mode, the reset mode is canceled.

- Avoid handling used filters if you suffer from allergies or asthma.
- Wear gloves when changing the filters, or wash your hands well afterwards.
- Put used filters directly into a closed, air-tight bag before throwing them away to avoid spreading pollutants.
STORAGE
When you are not using the appliance, store it in a cool, dry place.
IN THE EVENT OF A PROBLEM
- Never dismantle your appliance yourself. A poorly repaired appliance can cause risks for the user.
- Check the troubleshooting table below before contacting an approved Service Center:
| Problem Check Solution | ||
| The appliance will not switch on. | Is the power cord connected? | Connect the power cord to a plug with the correct voltage. |
| Are all the display elements off? | Press the start button and select the required function. | |
| Is there a power outage? | You can use your purifier once the power turns on again. | |
| Is the front door closed? Close the front door properly. | ||
| The flow is a lot weaker than before. | Does the filter need to be cleaned or replaced? | Check the filter cleaning and replacement frequencies and clean/replace the filter(s) if necessary. |
| There is an unpleasant smell coming from the air outlet. | Is the sensor lens covered with dust? | Check the filter cleaning and replacement frequencies and clean/replace the filter(s) if necessary. |
WARRANTY
Contact an approved Service Center if:
- your appliance has been dropped
- your appliance or its power cord is damaged
- your appliance is not working properly
LET'S HELP PROTECT THE ENVIRONMENT!

Your appliance contains valuable materials which can be recovered or recycled.
Leave it at a local waste collection point or take to an approved service center so that it can be processed.
EN

說明
產品說明
A 夜燈功能(僅限於PU6015型號
B 可調較的排氣柵
C 控制面板
D 前門板
E 手把
F 進氣口
G 微粒感測器
燈號
1 濾網更換指示燈
2 過濾速度
3 計時器/定時開啟
4 負離子功能
控制按钮
5 燈光
6 重置濾網
7 運行
8 過濾速度選擇
9 計時器/定時開啟
10負離子功能
第一層:
前層濾網 活性碳濾網


HEPA濾網

프리필터 액티브카본 필터 나노 캡쳐


헤파필터

(Nanocaptur)필터



УРОВЕНЬ 1:
ФИЛЬТР

Pra-penapis

Penapis HEPA

Penapis NanoCaptur
แผนกรองชั้นแรก