MICROLIFE BP B3 BT - Sphygmomanometer

BP B3 BT - Sphygmomanometer MICROLIFE - Free user manual and instructions

Find the device manual for free BP B3 BT MICROLIFE in PDF.

📄 96 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice MICROLIFE BP B3 BT - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Automatic Upper Arm Blood Pressure Monitor
Model BP B3 BT
Brand Microlife
Measurement Method Oscillometric
Measurement Range (Blood Pressure) 30 – 280 mmHg
Measurement Range (Pulse) 40 – 200 beats per minute
Accuracy (Blood Pressure) ±3 mmHg
Accuracy (Pulse) ±5% of reading
Cuff Size 22 – 42 cm (standard adult cuff)
Memory 60 readings with date and time
Irregular Heartbeat Detection Yes (IHB indicator)
WHO Classification Indicator Yes (color-coded display)
Average Measurement Function Yes (last 3 readings)
Bluetooth Connectivity Yes (for data sync with app)
Power Supply 4 x AAA batteries or AC adapter (6V, 600 mA)
Auto Power-Off Yes (after 1 minute)
Display LCD digital display
Dimensions (approx.) 12.0 x 10.0 x 6.0 cm
Weight (without batteries) Approximately 350 g
Operating Conditions 10°C to 40°C, 15% to 90% RH
Storage Conditions -20°C to 55°C, 10% to 95% RH
Cleaning Wipe with a soft, dry cloth. Do not use solvents.
Accessories Included Cuff (22-42 cm), batteries, storage bag, instructions
Certification CE, FDA, ISO 13485

Frequently Asked Questions - BP B3 BT MICROLIFE

How do I set the date and time on my Microlife BP B3 BT?
Press the SET button to enter date/time mode. Use the M button to adjust the year, month, day, hour, and minute. Press SET to confirm each setting.
Why does the device show an irregular heartbeat symbol?
The IHB symbol indicates that an irregular heartbeat was detected during the measurement. It means your heart rhythm varies by more than 25% from the average. If frequent, consult your doctor.
How do I pair the BP B3 BT with my smartphone?
Download the Microlife Health app (iOS/Android). On the device, press and hold the Bluetooth button until the icon flashes. In the app, select 'Add device' and follow the instructions.
Can I use the monitor without the Bluetooth feature?
Yes, the device works as a standard blood pressure monitor. Bluetooth is only for syncing data to the app. You can ignore it and take measurements as usual.
How do I clean the cuff and monitor?
For the monitor, wipe with a soft, dry cloth. For the cuff, clean with a damp cloth and mild soap if needed. Do not immerse in water or use harsh chemicals.
What does the WHO color bar indicator mean?
The color bar (green, yellow, orange, red) shows your blood pressure category according to WHO guidelines. Green is optimal, yellow is normal, orange is high-normal, and red indicates hypertension.
How many readings can be stored in memory?
The device stores up to 60 readings with date and time. Once full, the oldest reading is overwritten.
What should I do if the device displays an error code?
Common errors: E1 (cuff not connected properly), E2 (movement during measurement), E3 (battery low). Refer to the manual for all error codes. Ensure correct cuff placement and stay still.
How do I take a measurement correctly?
Sit comfortably with feet flat, back supported, and arm at heart level. Wrap the cuff around your upper arm. Press START. Do not speak or move during measurement.
Is the Microlife BP B3 BT suitable for use during pregnancy?
This device has not been clinically validated for preeclampsia. Consult your doctor before use if you are pregnant or have specific medical conditions.

User questions about BP B3 BT MICROLIFE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Sphygmomanometer in PDF format for free! Find your manual BP B3 BT - MICROLIFE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. BP B3 BT by MICROLIFE.

USER MANUAL BP B3 BT MICROLIFE

The following text will be followed by the author, "I'm not to know," and the author's name of the author's name is given by the author. The author's name of the author's name is given by the author's name of the author's name.

MICROLIFE BP B3 BT - 1

MICROLIFE BP B3 BT - 2

Pomahalal - 3 mohayar kow, Pomeromawert, w/ 185 n. m. m. (Pomeromawert, w/ 185 n. m. m. (Pomeromawert, w/ 185 n. m. m. (Pomeromawert, w/ 185 n. m. m. (Pomeromawert, w/ 185 n. m. m. (Pomeromawert, w/ 185 n. m. m. (Pomeromawert), w/ 185 n. m. m. (Pomeromawert, w/ 185 n. m. m. (Pomeromawert, w/ 185 n. m. m. (Pomeromawert, w/ 185 n. m. m. (Pomeromawert, w/ 185 n. m. m. (Pomeromawert, w/ 125 n. m. m. (Pomeromawert, w/ 125 n. m. m. (Pomeromawert, w/ 125 n. m. m. (Pomeromawert, w/ 125 n. m. m. (Pomeromawert, w/ 125 n. m. m. (Pomeromawert, w/ 125 n. m, (Pomeromawert, w/ 125 n. m. m. (Pomeromawert, w/ 125 n. m. m. (Pomeromawert, w/ 125 n. m. m. (Pomeromawert, w/ 125 n. m. m. (Pomeromawert, w/ 125 n. m. m. (Pomeromavert, w/ 125 n. m. m. (Pomeromavert, w/ 125 n. m. m. (Pomeromavert, w/ 125 n. m. m. (Pomeromavert, w/ 125 n. m. m. (Pomeromavert, w/ 125 n. m, (Pomeromavert, w/ 125 n. m, (Pomeromavert, w/ 125 n. m, (Pomeromavert, w/ 125 n. m, (Pomeromavert, w/ 125 n. m, (Pomeromavert, w/ 125 n. m, (Pomeromavert, w/ 125 n, (Pomeromavert, w/ 125 n, (Pomeromavert, w/ 125 n, (Pomeromavert, w/ 125 n, (Pomeromavert, w/ 125 n, (Pomeromavert, w/ 125 n, (Pomeromavert, w/ 125 n, (Pomeromavert, w / 125 n.m.m.(Pomeromavert, w/ 125 n.m.m.(Pomeromavert, w/ 125 n.m.m.(Pomeromavert, w/ 125 n.m.m.(Pomeromavert, w/ 125 n.m.m.(Pomeromavert, w/ 125 n.m.m.(Pomeromavert, w/ 125 n.m.m.(Pomeromavert, w/ 120 n.m.m.(Pomeromavert, w/ 120 n.m.m.(Pomeromavert, w/ 120 n.m.m.(Pomeromavert, w/ 120 n.m.m.(Pomeromavert, w/ 120 n.m.m.(Pomeromavert, w/ 120 n.m.m.(Pomeromavert, w/ 120 n.m.m(

The full class, but not just. (For example, we have a very little, very little, very little) of the course. (Of course, we have a very little, very little, very little) of the course. (For example, we have a very little, very little, very little) of the course. (Of course, we have a very little, very little, very little) of the course. (For example, we have a very little, very little, very little) of the course. (Of course, we have a very little, very little, very little) of the course. (For example, we have a very little, very little, very little) of the Course.

MICROLIFE BP B3 BT - 3

In the way we will be a real part of the main word, I have been made to find it. It is a very simple and very simple example that I can be used to use the same way. The way is not to be a simple example. I can be used to use the same way.

Microlio AG

Exper release 139

2442 Wohau/Switzerland

www.elsec.com

C€0044

EUP 2017-03-05

Microlife BP BS BT Microlife BP B3 BT Microlife BP B3 BT Guarantee Card Before each measurement

Technical diagram of a blood pressure monitor with labeled components and digital display showing reading values

microlife

1.

MICROLIFE BP B3 BT - 5

Avidating, having smoking cigarette prices 50 mls. Indication: tobacco price, 20 cents. Expenditure of tobacco products for the product is 20 cents per day.

Indication: tobacco price, 10 cents per day. Expenditure of tobacco products is 10 cents per day.

Indication: tobacco price, 10 cents per day. Expenditure of tobacco products is 10 cents per day.

Indication: tobacco price, 10 cents per day. Expenditure of tobacco products is 10 cents per day.

Indication: tobacco price, 10 cents per day. Expenditure of tobacco products is 10 cents per day.

Indication: tobacco price, 10 cents per day.

2.

MICROLIFE BP B3 BT - 6

Jahari activity and work in 10 min. B. P. (2) A class of an employee who has a computer-based programming tool. In addition to the computer's usage, it is not possible for all the users. A class of an employee with a computer, but it is not possible for all the users. System to use a computer with a computer, but it is not possible for all the users. System to use a computer with a computer, but it is not possible for all the users. Lagang, a teacher, is also available as at least 10 minutes. Kazak, in all kinder people, is also available as at least 10 minutes. Lagang, a teacher, is also available as at least 10 minutes. U. Lagang, a teacher, is also available as at least 10 minutes.

3.

MICROLIFE BP B3 BT - 7

Hawes befoamed sallar hake Hawes he apogrena reacnica Hawes inay, rava mala, marjavna a havan inam a vana nucena Havan perwtae cial pashra ka Havan deacnica eal, fara baka Havan tana pumutum nurni Obert inagc o zunup kwa Havan agyocce feudicu and fandir spintuagcn a conor lge Havan pumutum kwa

Name of Purchases / 10.12. (Note: One)
Firm - non-purchasing / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperforming / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperformings / Nonperforming

Sena N. maw / Cenab - A. kawp / Deszem kowep / Numar de serie / Vijcom drak / Vink 4/30 / Berjaka skolva / Berjak broj / Socrazazam / Berjaki broj / Numar senny

Echel F. Funches / Flume in herpice / Dalmi ni ascipitie 2/ Dura compiesy / Dalmi nianu / Darmi lity / Dalmi nianu / Dalmi kuposce dactetra dturna / Dalmi nianu / Dalmi rolo, pui

Special Data / Special data processing process Special data processing / Distribution of special data / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special data Processing / Special dataProcessing

microlife

① ON/OFF button
② Display
③ M-button (memory)
④ MAM button
⑤ User Button
⑥ Cuff Socket
⑦ Mains Adapter Socket
⑧ Battery Compartment
⑨ Cuff
⑩ Cuff Connector
⑪ Cuff Tube

Display

⑫ Active Bluetooth®
⑬ Systolic Value
⑭ Diastolic Value
⑮ Pulse Rate
⑯ MAM Mode
⑰ Battery Display
⑱ Cuff Fit Check

-A: Suboptimal Cuff Fit
-B: Arm Movement Indicator «Err 2»
-C: Cuff Pressure Check «Err 3»

⑲ Cuff Signal Indicator «Err 1»
⑳ Irregular Heartbeat (IHB) Symbol
②1 MAM Interval Time
②2 Traffic Light Indicator
②3 Pulse Indicator
⑳ User Indicator
⑲ Average Indicator «MyCheck»
②6 Stored Value
⑳ Clinical Blood Pressure Average «MyBP»
⑳ Date/Time

MICROLIFE BP B3 BT - Display - 1

Read the instructions carefully before using this device.

MICROLIFE BP B3 BT - Display - 2

Type BF applied part

MICROLIFE BP B3 BT - Display - 3

Keep dry

Intended use:

This oscillometric blood pressure monitor is intended for measuring non-invasive blood pressure in people aged 12 years or older.

It is clinically validated in patients with hypertension, hypotension, diabetes, pregnancy, pre-eclampsia, atherosclerosis, end-stage renal disease, obesity and the elderly.

Dear Customer,

This device was developed in collaboration with physicians and clinical tests carried out prove its measurement accuracy to be of a very high standard.*

If you have any questions, problems or want to order spare parts please contact your local Microlife-Customer Service. Your dealer or pharmacy will be able to give you the address of the Microlife dealer in your country. Alternatively, visit the internet at www.microlife.com where you will find a wealth of invaluable information on our products.

Stay healthy – Microlife AG!

* This device uses the same measuring technology as the award winning «BP 3BTO-A» model tested according to the British and Irish Hypertension Society (BIHS) protocol.

Table of Contents

1. Using the Device for the First Time

  • Inserting the batteries
  • Setting the date and time
  • Selecting the correct cuff
  • Selecting the user
  • Selecting standard or MAM mode

2. Checklist for Taking a Reliable Measurement

3. Taking a Blood Pressure Measurement

  • Manual inflation
    • How not to store a reading
    • How do I evaluate my blood pressure?
    • Average Indicator «MyCheck»
  • Appearance of the Irregular Heartbeat (IHB) Symbol

4. Data Memory

  • Viewing the clinical blood pressure average «MyBP»
    • Viewing the average of the last 28 days
    • Viewing the stored single values
  • Clearing all values

5. Battery Indicator and Battery change

  • Low battery
  • Flat battery – replacement
  • Which batteries and which procedure?
    • Using rechargeable batteries

6. Using a Mains Adapter

7. Bluetooth® Function

8. Error Messages

9. Safety, Care, Accuracy Test and Disposal

  • Safety and protection
  • Device care
  • Cleaning the cuff
  • Accuracy test
  • Disposal

10. Guarantee

11. Technical Specifications Guarantee Card (see Back Cover)

1. Using the Device for the First Time

Inserting the batteries

After you have unpacked your device, first insert the batteries. The battery compartment ⑧ is on the bottom of the device. Insert the batteries (4 x 1.5 V, size AA), thereby observing the indicated polarity.

Setting the date and time

  1. After the new batteries are fitted, the year number flashes in the display. You can set the year by pressing the M-button ③. To confirm and then set the month, press the MAM button ④.

  2. Press the M-button to set the month. Press the MAM button to confirm and then set the day.

  3. Follow the instructions above to set the day, hour and minutes.
  4. Once you have set the minutes and pressed the MAM button, the date and time are set and the time is displayed.
  5. If you want to change the date and time, press and hold the MAM button for approx. 3 seconds until the year number starts to flash. Now you can enter the new values as described above.

Selecting the correct cuff

Microlife offers different cuff sizes. Select the cuff size to match the circumference of your upper arms (measured by close fitting in the centre of the upper arm).

Cuff size for circumference of upper arm
S 17 - 22 cm
M 22 - 32 cm
M - L 22 - 42 cm
L 32 - 42 cm
L - XL 32 - 52 cm

Only use Microlife cuffs.

Contact your local Microlife Service if the enclosed cuff ⑨ does not fit.
Connect the cuff to the device by inserting the cuff connector ⑩ into the cuff socket ⑥ as far as it will go.

Selecting the user

This device allows to store the results for 2 individual users.

▶ Select the intended user (user 1 or user 2 ②4) by pressing the user button ⑤.

Before each measurement, ensure that the correct user is selected.

Selecting standard or MAM mode

Before each measurement, select standard (single measurement) or MAM mode (automatic triple measurement). In MAM mode, 3 measurements are automatically taken in succession and the result is then automatically analysed and displayed. Because the blood pressure constantly fluctuates, a result obtained in this way is more reliable than when a single measurement is performed.

- To select MAM mode, press the MAM button ④ until the MAM-symbol ⑯ appears on the display. To change to standard mode (single measurement), press the MAM-button again, until the MAM-symbol disappears.

  • The bottom, right hand section of the display shows a 1, 2 or 3 to indicate which of the 3 measurements is currently being taken.
  • There is a break of 15 seconds between the measurements. A count down indicates the remaining time.
  • The individual results are not displayed. Your blood pressure will only be displayed after all 3 measurements are taken.
  • Do not remove the cuff between measurements.
  • If one of the individual measurements was questionable, a fourth one is automatically taken.

2. Checklist for Taking a Reliable Measurement

  • Avoid activity, eating or smoking immediately before the measurement.
  • Sit down on a back-supported chair and relax for 5 minutes. Keep the feet flat on the floor and do not cross your legs.
    ▶ Always measure on the same arm (normally left). It is recommended that doctors perform double arm measurements on a patients first visit in order to determine which arm to measure in the future. The arm with the higher blood pressure should be measured.
    Remove close-fitting garments from the upper arm. To avoid constriction, shirt sleeves should not be rolled up - they do not interfere with the cuff if they are laid flat.
    ▶ Always ensure that the correct cuff size is used (marking on the cuff).
    • Fit the cuff closely, but not too tight.
  • Make sure that the cuff is positioned 1-2 cm above the elbow.
  • The artery mark on the cuff (ca. 3 cm long bar) must lie over the artery which runs down the inner side of the arm.
    • Support your arm so it is relaxed.
  • Ensure that the cuff is at the same height as your heart.

3. Taking a Blood Pressure Measurement

  1. Select standard (single measurement) or MAM mode (automatic triple measurement): see details in chapter «1.».
  2. Press the ON/OFF button ① to start the measurement.
  3. The cuff will now pump up automatically. Relax, do not move and do not tense your arm muscles until the measurement result is displayed. Breathe normally and do not talk.
  4. The cuff fit check ⑱ on the display indicates that the cuff is perfectly placed. If the icon ⑳-A appears, the cuff is fitted suboptimally, but it is still ok to measure.

  5. When the correct pressure is reached, the pumping stops and the pressure falls gradually. If the required pressure was not reached, the device will automatically pump some more air into the cuff.

  6. During the measurement, the pulse indicator ②3 flashes in the display.
  7. The result, comprising the systolic ⑬ and the diastolic ⑭ blood pressure and the pulse rate ⑮ is displayed. Note also the explanations on further display symbols in this booklet.
  8. When the device has finished measuring, remove the cuff.
  9. Switch off the device. (The monitor does switch off automatically after approx. 1 min.).
    You can stop the measurement at any time by pressing the ON/OFF button (e.g. if you feel uneasy or an unpleasant pressure sensation).
    This monitor is specially tested for use in pregnancy and pre-eclampsia. When you detect unusual high readings in pregnancy, you should measure after a short while again (eg. 1 hour). If the reading is still too high, consult your doctor or gynecologist.

Manual inflation

In case of high systolic blood pressure (e.g. above 135 mmHg), it can be an advantage to set the pressure individually. Press the ON/OFF button after the monitor has been pumped up to a level of approx. 30 mmHg (shown on the display). Keep the button pressed until the pressure is about 40 mmHg above the expected systolic value – then release the button.

How not to store a reading

As soon as the reading is displayed press and hold the ON/OFF button ① until «M» ②6 is flashing. Confirm to delete the reading by pressing the MAM button ④.

«CL» is displayed when the reading is deleted from the memory successfully.

How do I evaluate my blood pressure?

The triangle on the left-hand edge of the display ② points at the range within which the measured blood pressure value lies. The value is either within the optimum (green), elevated (yellow) or high (red) range. The classification corresponds to the following ranges defined by international guidelines (ESH, ESC, JSH). Data in mmHg.

Range Systolic Diastolic Recommendation

1.blood pressure too high≥135 ≥85Seek medical advice
2.blood pressure elevated130 - 13480 - 84 Self-check
3.blood pressure normal<130 <80Self-check

The higher value is the one that determines the evaluation. Example: a blood pressure value of 140/80 mmHg or a value of 130/90 mmHg indicates «blood pressure too high».

Average Indicator «MyCheck»

This symbol ② indicates after each measurement, if the most recent measured value lies below, above or on the same level as your stored average value (see also chapter «4. Data Memory»).

If the measured Systole or Diastole is more than 5mmHg higher than the stored average, the arrow shows upwards. If the measured Systole or Diastole is more than 5mmHg lower than the stored average, the arrow shows downwards.
If the measured Systole and Diastole do not differ by more than 5mmHg from the stored average, the arrow shows straight on.
If the measured systole and diastole differ in different directions from the stored average, this is indicated first with the systole figure flashing, together with the up or down arrow for two seconds. Thereafter, the diastole figure flashes with the arrow pointing up or down for two seconds.

Appearance of the Irregular Heartbeat (IHB) Symbol

This symbol ⑳ indicates that an irregular heartbeat was detected. In this case, the measured blood pressure may deviate from your actual blood pressure values. It is recommended to repeat the measurement.

Information for the doctor in case of repeated appearance of the IHB symbol:

This device is an oscillometric blood pressure monitor that also measures the pulse during blood pressure measurement and indicates when the heart rate is irregular.

4. Data Memory

This device automatically stores up to 99 measurement values for each of the 2 users.

Select either user 1 or 2 by pressing the user button ⑤.

Viewing the clinical blood pressure average «MyBP»

Pressing the M-button ③ briefly when the device is switched off, allows you to see the average clinically relevant blood pressure «MyBP». The display first shows «M» ②6 and «MyBP» ②7. This average is only shown when 12 clinically relevant measurement values in the last 28 days have been performed.

«MyBP» average is not displayed if the number of clinically relevant measurement values do not meet the «MyBP» criteria.

Only measurements that were performed in the morning between 05:00-10:59 or in the evening between 17:00-22:59 are considered.
A maximum of 4 readings per day are considered (2 from the morning and 2 from the evening).
Measurements performed in standard mode and in MAM-mode are considered in the average, when they have been performed during the right time of the day.
Measurements performed in MAM-mode or single standard mode are both classed as single measurements for working out the «MyBP average».
Blood pressure readings with suboptimal cuff fit ⑳-A are not considered in the average value.

Viewing the average of the last 28 days

Press the M-button ③ again. The display first shows «M» ②6 and «28A», which stands for the average measurement values of the last 28 days.

Blood pressure readings with suboptimal cuff fit ⑳-A are not considered in the average value.

Viewing the stored single values

Pressing the M-button again, allows you to see the last performed measurement. The display first shows «M» ②6 and a value, e.g. «M17». This means that there are 17 single values in the memory. Pressing the M-button again displays the previous value. Pressing the M-button repeatedly enables you to move from one stored value to another.

Pay attention that the maximum memory capacity of 99 memories is not exceeded. When the 99 memory is full, the oldest value is automatically overwritten with the 100th value. Values should be evaluated by a doctor before the memory capacity is reached – otherwise data will be lost.

Clearing all values

Make sure the correct user is activated.

If you are sure that you want to permanently remove all stored values, hold down the M-button (the device must have been switched off beforehand) until «CL ALL» appears and then release the button. To permanently clear the memory, press the MAM button while «CL ALL» is flashing. Individual values cannot be cleared.

Cancel deletion: press ON/OFF button① while «CL ALL» is flashing.

5. Battery Indicator and Battery change

Low battery

When the batteries are approximately 3/4 empty the battery symbol ⑰ will flash as soon as the device is switched on (partly filled battery displayed). Although the device will continue to measure reliably, you should obtain replacement batteries.

Flat battery – replacement

When the batteries are flat, the battery symbol ⑰ will flash as soon as the device is switched on (flat battery displayed). You cannot take any further measurements and must replace the batteries.

  1. Open the battery compartment ⑧ at the back of the device.
  2. Replace the batteries – ensure correct polarity as shown by the symbols in the compartment.
  3. To set date and time, follow the procedure described in «Section 1.».

The memory retains all values although date and time must be reset – the year number therefore flashes automatically after the batteries are replaced.

Which batteries and which procedure?

Use 4 new, long-life 1.5 V, size AA alkaline batteries.
Do not use batteries beyond their date of expiry.
Remove batteries if the device is not going to be used for a prolonged period.

Using rechargeable batteries

You can also operate this device using rechargeable batteries.

Only use «NiMH» type reusable batteries.
Batteries must be removed and recharged when the flat battery symbol appears. They should not remain inside the device as they may become damaged (total discharge as a result of low use of the device, even when switched off).
Always remove the rechargeable batteries if you do not intend to use the device for a week or more.
Batteries cannot be charged in the blood pressure monitor. Recharge batteries in an external charger and observe the information regarding charging, care and durability.

6. Using a Mains Adapter

You can operate this device using the Microlife mains adapter (DC 6V, 600 mA).
Only use the Microlife mains adapter available as an original accessory appropriate for your supply voltage.
Ensure that neither the mains adapter nor the cable are damaged.
1. Plug the adapter cable into the mains adapter socket ⑦ in the blood pressure monitor.
2. Plug the adapter plug into the wall socket.
When the mains adapter is connected, no battery current is consumed.

7. Bluetooth ® Function

This device can be used in conjunction with a smartphone running the «Microlife Connected Health+» App.

Bluetooth ® can be activated manually by pressing and holding the ON/OFF button ① for about 4 seconds until the Bluetooth symbol begins flashing ⑫.

Bluetooth ® is automatically activated ⑫ after a measurement has been completed.

Bluetooth pairing and set up is required to use this device with the «Microlife Connected Health+» App. It is recommended to manually activate Bluetooth® and connect to the

MICROLIFE BP B3 BT - Bluetooth ® Function - 1

«Microlife Connected Health+» App to synchronize the date and time settings between the device and the smartphone. In case of difficulties connecting the device with the «Microlife Connected Health+» App, try to reset the Bluetooth® connection of this device to default settings:

Press and hold the ON/OFF button ① for 8 seconds until «CL Pr» is displayed. This clears the Bluetooth® pairing records on the device and reset it to factory settings. Bluetooth® automatically activates after the reset.

For more detailed information visit www.microlife.com/connect.

8. Error Messages

If an error occurs during the measurement, the measurement is interrupted and an error message, e.g. «Err 3», is displayed.

Error Description Potential cause and remedy
«Err 1»19Signal too weakThe pulse signals on the cuff are too weak. Re-position the cuff and repeat the measurement.*
«Err 2»20-BError signalDuring the measurement, error signals were detected by the cuff, caused for instance by movement or muscle tension. Repeat the measurement, keeping your arm still.
«Err 3»20-CAbnormal cuff pressureAn adequate pressure cannot be generated in the cuff. A leak may have occurred. Check that the cuff is correctly connected and is not too loose. Replace the batteries if necessary. Repeat the measurement.
«Err 5» Abnormal resultThe measuring signals are inaccurate and no result can therefore be displayed. Read through the checklist for performing reliable measurements and then repeat the measurement.*
«Err 6»MAM ModeThere were too many errors during the measurement in MAM mode, making it impossible to obtain a final result. Read through the checklist for performing reliable measurements and then repeat the measurement.*
«HI» Pulse or cuff pressure too highThe pressure in the cuff is too high (over 299 mmHg) OR the pulse is too high (over 200 beats per minute). Relax for 5 minutes and repeat the measurement.*
Error Description Potential cause and remedy
«LO» Pulse too lowThe pulse is too low (less than 40 beats per minute). Repeat the measurement.*
MICROLIFE BP B3 BT - Error Messages - 1Problem with Bluetooth® connectionIf any problem occurs with the Bluetooth connection, the Bluetooth® icon 12blinks rapidly for approximately 10 seconds. To solve the problem, please visit www.microlife.com/connect.

* Please immediately consult your doctor, if this or any other problem occurs repeatedly.

9. Safety, Care, Accuracy Test and Disposal

MICROLIFE BP B3 BT - Safety, Care, Accuracy Test and Disposal - 1

Safety and protection

  • Follow instructions for use. This document provides important product operation and safety information regarding this device. Please read this document thoroughly before using the device and keep for future reference.
  • This device may only be used for the purposes described in these instructions. The manufacturer cannot be held liable for damage caused by incorrect application.
  • This device comprises sensitive components and must be treated with caution. Observe the storage and operating conditions described in the «Technical Specifications» section.
  • Protect it from:

  • water and moisture

  • extreme temperatures
  • impact and dropping
  • contamination and dust
  • direct sunlight
  • heat and cold

  • The cuffs are sensitive and must be handled with care.

  • Do not exchange or use any other kind of cuff or cuff connector for measuring with this device.
    • Only pump up the cuff once fitted.
  • Do not use this device close to strong electromagnetic fields such as mobile telephones or radio installations. Keep a minimum distance of 3.3 m from such devices when using this device.
  • Do not use this device if you think it is damaged or notice anything unusual.
  • Never open this device.
  • If the device is not going to be used for a prolonged period the batteries should be removed.

  • Read the additional safety information provided within the individual sections of this instruction manual.

  • If you suffer from a cardiac arrhythmia consult with your doctor before using the device. See also chapter «Appearance of the Irregular Heartbeat (IHB) Symbol» of this user manual.
  • The measurement results given by this device is not a diagnosis. It is not replacing the need for the consultation of a physician, especially if not matching the patient's symptoms. Do not rely on the measurement result only, always consider other potentially occurring symptoms and the patient's feedback. Calling a doctor or an ambulance is advised if needed.
  • Permanently high blood pressure values can damage your health and must be treated by your doctor!
  • Always discuss your values with your doctor and tell him/her if you have noticed anything unusual or feel unsure. Never rely on single blood pressure readings.
  • Under no circumstances should you alter the dosages of drugs or initiate a treatment without consulting your doctor.
  • Deviations between measurements taken by your doctor or in the pharmacy and those taken at home are quite normal, as these situations are completely different.
  • The pulse display is not suitable for checking the frequency of heart pacemakers!
  • If you are pregnant, you should monitor your blood pressure regularly as it can change drastically during this time.
    Ensure that children do not use this device unsupervised; some parts are small enough to be swallowed. Be aware of the risk of strangulation in case this device is supplied with cables or tubes.
    Clean the device only with a soft, dry cloth.
    The cuff delivered with this device is washable.
  • Remove the cuff connector ⑩ from the cuff tube ⑪ and carefully pull the bladder through the opening at the edge of the cuff cover.
  • Hand wash the cuff cover in soapsuds: not hotter than 30 °C.
  • Completely dry the cuff cover by linen drying.
  • Loop the cuff tube back through its opening and carefully place the bladder flat in the cuff cover.
  • Reattach the cuff connector on the cuff tube.

MICROLIFE BP B3 BT - Safety and protection - 1

Device care

Cleaning the cuff

MICROLIFE BP B3 BT - Cleaning the cuff - 1

The bladder must lay straight in the cuff cover, not folded. Do not use fabric softener.

MICROLIFE BP B3 BT - Cleaning the cuff - 2

WARNING: Do not wash the cuff in a washing machine or dishwasher!

MICROLIFE BP B3 BT - Cleaning the cuff - 3

WARNING: Do not dry the cuff cover in a tumble dryer!

MICROLIFE BP B3 BT - Cleaning the cuff - 4

WARNING: Under no circumstances may you wash the inner bladder!

Accuracy test

We recommend this device is tested for accuracy every 2 years or after mechanical impact (e.g. being dropped). Please contact your local Microlife-Service to arrange the test (see foreword).

Disposal

MICROLIFE BP B3 BT - Disposal - 1

Batteries and electronic devices must be disposed of in accordance with the locally applicable regulations, not with domestic waste.

10. Guarantee

This device is covered by a 5 year guarantee from the date of purchase. During this guarantee period, at our discretion, Microlife will repair or replace the defective product free of charge.

Opening or altering the device invalidates the guarantee.

The following items are excluded from the guarantee:

• Transport costs and risks of transport.
- Damage caused by incorrect application or non-compliance with the instructions for use.
• Damage caused by leaking batteries.
• Damage caused by accident or misuse.
- Packaging/storage material and instructions for use.
• Regular checks and maintenance (calibration).
- Accessories and wearing parts: Batteries, power adapter (optional).

The cuff is covered by a functional guarantee (bladder tightness) for 2 years.

Should guarantee service be required, please contact the dealer from where the product was purchased, or your local Microlife service. You may contact your local Microlife service through our website:

www.microlife.com/support

Compensation is limited to the value of the product. The guarantee will be granted if the complete product is returned with the original invoice. Repair or replacement within guarantee does not prolong

or renew the guarantee period. The legal claims and rights of consumers are not limited by this guarantee.

  1. Technical Specifications
Operating conditions:10 - 40 °C / 50 - 104 °F
15 - 95 % relative maximum humidity
Storage conditions:-20 - +55 °C / -4 - +131 °F
15 - 95 % relative maximum humidity
Weight:402 g (including batteries)
Dimensions:138 x 94.5 x 62.5 mm
Measuring procedure:oscillometric, corresponding to Korotkoff method: Phase I systolic, Phase V diastolic
Measurement range:20 - 280 mmHg – blood pressure
40 - 200 beats per minute – pulse
Cuff pressure display range:0 - 299 mmHg
Resolution:1 mmHg
Static accuracy:pressure within ± 3 mmHg
Pulse accuracy:± 5 % of the readout value
Communication: Bluetooth ® 4.2
Compatibility: iOS: iOS 8.0 or newer
Android: Android 4.4.2 or newer
Voltage source:4 x 1.5 V alkaline batteries; size AA
Mains adapter DC 6V, 600 mA (optional)
Battery lifetime: approx. 920 measurements(using new batteries)
IP Class: IP20
Reference to standards:EN 1060-1 /-3 /-4; IEC 60601-1;IEC 60601-1-2 (EMC); IEC 60601-1-11
Expected service life:Device: 5 years or 10000 measurements
Accessories: 2 years
This device complies with the requirements of the Medical Device Directive 93/42/EEC.
Technical alterations reserved.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Micro-life Corp. is under license. Other trademarks and trade names are those of their respective owners.

WARNING: Under no circumstances may you wash the inner bladder!

Проверка точности

Batteries and electronic devices must be disposed of in accordance with the locally applicable regulations, not with domestic waste.

10.Гарантия

Stay healthy – Microlife AG!

In case of high systolic blood pressure (e.g. above 135

mmHg), it can be an advantage to set the pressure individually. Press the ON/OFF button after the monitor has been pumped up to a level of approx. 30 mmHg (shown on the display). Keep the button pressed until the pressure is about 40 mmHg above the expected systolic value – then release the button.

This device allows to store the results for 2 individual users.

* Please immediately consult your doctor, if this or any other problem occurs repeatedly.

Clean the device only with a soft, dry cloth.

Čiščenje manšete

Manšeta priložena poleg aparata je pralna.

  1. Odstranite priključek manšete ⑩ s cevke manšete ⑪ in previdno potegnite gumijasti notranji del manšete skozi odprtino na robu prevleke manšete.

  2. Manšeto ročno očistite z milnico, katera ne presega 30 °C.

  3. Prevleko manšete do konca posušite na zraku.
  4. Cevko manšete vstavite nazaj skozi odprtino in previdno name-stite gumijasti notranji del manšete plosko v prevleko manšete.
  5. Ponovno priključite priključek manšete na cevko manšete.

Gumijasti notranji del manšete mora ležati ravno v prevleki manšete in ne sme biti prepognjen.
Ne uporabljajte mehčalca za perilo.
OPOZORILO: Manšete ne smete prati v pralnem ali pomi-valnem stroju!
OPOZORILO: Manšete ne sušite v sušilnem stroju!
OPOZORILO: Pod nobenimi pogoji ne smete prati notranjega dela manšete!

Test natančnosti

www.microlife.com/support

Nadomestilo je omejeno na vrednost izdelka. Garancija se odobri, će se celoten izdelek vrne z originalnim računom. Popravilo ali zamenjava znotraj garancije ne podaljša ali obnovi garancijske dobe. Pravni zahtevki in pravice potrošnikov s to garancijo niso omejeni..

- Do not use this device close to strong electromagnetic fields such as mobile telephones or radio installations. Keep a minimum distance of 3.3 m from such devices when using this device.

- Do not use this device if you think it is damaged or notice anything unusual.

www.microlife.com/support

Kompenzacija je ograničena na vrednost proizvoda. Garancija će biti uvažena ako se vrati kompletan proizvod sa originalnim računom. Popravka ili zamena u garantnom roku ne produžava niti obnavlja garantni period.

11.Tehničke specifikacije

Radni uslovi: 10 - 40 °C / 50 - 104 °F
15 - 95 % relativna maksimalna vlažnost
Uslovi čuvanja:-20 - +55 °C / -4 - +131 °F
15 - 95 % relativna maksimalna vlažnost
Težina:402 g (uključujući baterije)

Dimenzije: 138 x 94.5 x 62.5 mm

Postupak merenja: oscilometrijski, u skladu sa Korotkoff-ovom metodom: Faza I sistolna, Faza V dijastolna

Raspon merenja: 20 - 280 mmHg – krvni pritisak 40 - 200 otkucaja u minuti – puls

Prikazani raspon

Do not use fabric softener.

MICROLIFE BP B3 BT - 11.Tehničke specifikacije - 1

www.microlife.com/support

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : MICROLIFE

Model : BP B3 BT

Category : Sphygmomanometer