CANopen does not provide for two identical EMCY objects to be sent consecutively.
| Index S-index Design Data type Default Details | |
| 0x1000 Device type ro UDINT 0x00F0191 Device type | |
| 0x1001 Error register ro USINT 0 Error register bit coded to profile | 301
Permissible values:
0b0000 0000 = no error
0b0000 0001 = generic error
0b0001 0000 = communication error
0b1000 0000 = manufacturer specific |
| 0x1018 0x00 Device identification Number of entries | ro USINT 0x04 | Device | identification |
|
| 0x01 | Vendor-ID | ro | UDINT | 0x0069666D | Vendor ID oft he device according to CiA specification |
| 0x02 | Product code ro STRING 0 Product code of the device |
| 0x03 | Revision number | ro UDINT 0 Revision number of the device |
| 0x04 | Serial number | ro UDINT 0 Serial number of the device |
| 0x1003 0x00 Predefined error field Number of entries | rw | UDINT 0 An error list with 4 entries is supported |
| 0x01 | Error history | ro UDINT 0 Error occurred, coded according to EMCY list The last error is indicated in the sub-index 1 |
| 0x02 | Error history | ro UDINT 0 Error occurred, coded according to EMCY list |
| 0x03 | Error history | ro UDINT 0 Error occurred, coded according to EMCY list |
| 0x04 | Error history | ro UDINT 0 Error occurred, coded according to EMCY list |
| 0x05 | Error history | ro UDINT 0 Error occurred, coded according to EMCY list |
| Index S-index Design Data type | Default Details | |
| 0x1005 | COB-ID | synch message | rw U | DINT 0x000 | 0080 Identifier of the synch messageBit 30 = 0 → device generates no synch messageBit 30 = 1 → device generates a synch messageBit 29 = 0 → 11 bit IDBit 29 = 1 → ID = 0x80 + node ID |
| 0x1006 | Communication cycle period | | rw U | DINT 0 Max. time between 2 synch objects in [μs]Control resolution = 1 ms |
| 0x1008 | Manufacturer device name | ro STRING CR204x Device designation (CR2040 or CR2041 or CR2042) |
| 0x1009 | Manufacturer hardware version | ro STRING V00.00.00 Hardware version |
| 0x100A | Manufacturer software version | ro STRING V00.00.00 Software version |
| 0x1010 | 0x00 | Store parametersLargest sub-index supported | ro USINT 0x01 | Number of "save options" |
| 0x01 | Save all parameters | rw U | DINT 2 Automatic saving of all parameters changed0 = AutoSave OFF2 = AutoSave ON |
| 0x1011 | 0x00 | Restore default parametersLargest sub-index supported | ro USINT 0x01 | Number of "restore options" |
| 0x01 | Restore all default parameters | rw U | DINT 0x01 | If the String "load" is entered here, the default parameters set at the factory are restored and become valid after the next reset. |
| 0x1014 | COBIidEmergency | rw | UDINT | 0x80 + node ID | Bit 31 = 0 → EMCY is validBit 31 = 1 → EMCY is not validBit 29 = 0 → 11-bit IDBit 29 = 1 → ID = 0x80 + node IDCAN identifier can be changed by the user. |
| Index S-index Design Data type Default Details | |
| 0x1016 | 0x00 | Consumer heartbeat times | ro USINT 0x01 Heartbeat monitoring | time for the nodeNumber of devices monitored = 1 |
| Numbers consumer heartbeat time |
| 0x01 | Consumer heartbeat time | rw USINT 0 Heartbeat monitoring | time for the nodeFormat: 0x0nntttttt tt=monitoring time [ms] nn = node numberif nn=0 or tttt=0 → no monitoring |
| 0x1017 | Producer | heartbeat time | rw USINT 0 Time | interval [ms] during | which the device generates a producer heartbeat |
| Index Sidx Designation Data type Default Details | |
| 0x1800 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 1number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x180 +Node ID | CAN ID of the transmit PDO 1Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0xFF 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UINT | 0 | delay time | in the transmissiontype "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 | | reserve | |
| 0x05 event time | rw | UINT | 0 | max. transfer break in the transmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| 0x1801 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 2number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x280 +Node ID | CAN ID of the transmit PDO 2Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| 0x1802 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 3number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x380 +Node ID | CAN ID of the transmit PDO 3Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index S-index Design Data type Default Details | |
| 0x1803 0x00 TransmitPDO CommunicationParameterNumber ofentries | ro USINT 0x05 Configuration transmits PIO number of entries = 5 |
| 0x01 OBID usedby PDO | rw USINT 0x480 +Node ID | CAN ID of the transmit PDO 4Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" syncho objectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UINT 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event timerw UINT 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index Sidx Designation Data type Default Details | |
| 0x1804 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 5number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x181 +Node ID | CAN ID of the transmit PDO 5Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index S-index Design Data type Default Details | |
| 0x1805 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 6number of entries = 5 |
| 0x01 OBID usedby PDO | rw USINT 0x281 +Node ID | CAN ID of the transmit PDO 6Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UINT 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event timerw UINT 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index Sidx Designation Data type Default Details | |
| 0x1806 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 7number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x381 +Node ID | CAN ID of the transmit PDO 7Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xFD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| 0x1807 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 8number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x481 +Node ID | CAN ID of the transmit PDO 8Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| 0x1808 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 9number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x182 +Node ID | CAN ID of the transmit PDO 9Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xFD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| 0x1809 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 10number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x282 +Node ID | CAN ID of the transmit PDO 10Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index S-index Design Data type Default Details | |
| 0x1A00 | 0x00 TransmitPDO map-pingNumber of mapped objects in PDO | rw USINT 0x07 mapping transmit | PDO 1number of integrated applicationobjects = 7 |
| 0x01 PDO map-ping | rw USINT 0x60000108 Index 0x6000, SubIndex 0x01binary inputs 00...07: actual values(bit coded) |
| 0x02 PDO map-ping | rw USINT 0x60000208 Index 0x6000, SubIndex 0x02binary inputs 08...15: actual values(bit coded) |
| 0x03 PDO map-ping | rw USINT 0x20200108 Index 0x2020, SubIndex 0x01binary inputs 00...07: flag "shortcircuit" (bit coded) |
| 0x04 PDO map-ping | rw USINT 0x20200208 Index 0x2020, SubIndex 0x02binary inputs 08...15: flag "shortcircuit" (bit coded) |
| 0x05 PDO map-ping | rw USINT 0x20210108 Index 0x2021, SubIndex 0x01outputs 00...07: flag " wire break " (bit coded) |
| 0x06 PDO map-ping | rw USINT 0x20210208 Index 0x2021, SubIndex 0x02outputs 08...15: flag " wire break " (bit coded) |
| 0x07 PDO map-ping | rw USINT 0x20250108 Index 0x2025, SubIndex 0x01inputs 00...03: flag " overload " (bit coded) |
| Index Sidx Design Data type |
| 0x1A01 | 0x00 TransmitPDO map-pingNumber of mapped objects in PDO | rw USINT 0x04 mapping transmit | PDO 2 (analogue inputs)number of integrated application objects = 4 |
| 0x01 PDO map-ping | rw USINT 0x64040110 Index 0x6404, SubIndex 0x01 analogue input 00: actual value (depending on the configuration 0x2000) |
| 0x02 PDO map-ping | rw USINT 0x64040210 Index 0x6404, SubIndex 0x02 analogue input 01: actual value (depending on the configuration 0x2000)) |
| 0x03 PDO map-ping | rw USINT 0x64040310 Index 0x6404, SubIndex 0x03 analogue input 02: actual value (depending on the configuration 0x2000) |
| 0x04 PDO map-ping | rw USINT 0x64040410 Index 0x6404, SubIndex 0x04 analogue input 03: actual value (depending on the configuration 0x2000) |
| 0x1A02 | 0x00 TransmitPDO map-pingNumber of mapped objects in PDO | rw USINT 0x04 mapping transmit | PDO 3 (analogue inputs)number of integrated application objects = 4 |
| 0x01 PDO map-ping | rw USINT 0x64040510 Index 0x6404, SubIndex 0x05 analogue input 04: actual value (depending on the configuration 0x2000) |
| 0x02 PDO map-ping | rw USINT 0x64040610 Index 0x6404, SubIndex 0x06 analogue input 05: actual value (depending on the configuration 0x2000)) |
| 0x03 PDO map-ping | rw USINT 0x64040710 Index 0x6404, SubIndex 0x07 analogue input 06: actual value (depending on the configuration 0x2000) |
| 0x04 PDO map-ping | rw USINT 0x64040810 Index 0x6404, SubIndex 0x08 analogue input 07: actual value (depending on the configuration 0x2000) |
| Index S-idx Design Data type | Default Details | |
| 0x1A03 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x04 mapping transmit | PDO 4number of integrated applicationobjects = 4 |
| 0x01 PDO mapping | rw USINT 0x20300110 Index 0x2030, SubIndex 0x01input 08: actual resistor value |
| 0x02 PDO mapping | rw USINT 0x20300210 Index 0x2030, SubIndex 0x02input 10: actual resistor value |
| 0x03 PDO mapping | rw USINT 0x20300310 Index 0x2030, SubIndex 0x03input 12: actual resistor value |
| 0x04 PDO mapping | rw USINT 0x20300410 Index 0x2030, SubIndex 0x04input 14: actual resistor value |
| 0x1A04 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x02 mapping transmit | PDO 5 (periodetime IN09, IN11)number of integrated applicationobjects = 2 |
| 0x01 PDO mapping | rw USINT 0x20120120 Index 0x2012, SubIndex 0x01frequency input IN09: periode time ofthe signal |
| 0x02 PDO mapping | rw USINT 0x20120220 Index 0x2012, SubIndex 0x02frequency input IN11: periode time ofthe signal |
| 0x1A05 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x02 mapping transmit | PDO 6 (periodetime IN13, IN15)number of integrated applicationobjects = 2 |
| 0x01 PDO mapping | rw USINT 0x20120320 Index 0x2012, SubIndex 0x03frequency input IN13: periode time ofthe signal |
| 0x02 PDO mapping | rw USINT 0x20120420 Index 0x2012, SubIndex 0x04frequency input IN15: periode time ofthe signal |
| Index Sidx Design Data type |
| 0x1A06 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x04 mapping transmit | PDO 7 (duty cycle of the signal on the frequency input IN09, IN11, IN13, IN15) number of integrated application objects = 4 |
| 0x01 PDO mapping | rw USINT 0x2014 0110 Index 0x2014, SubIndex 0x01 frequency input IN09: duty cycle of the signal in %o |
| 0x02 PDO mapping | rw USINT 0x2014 0210 Index 0x2014, SubIndex 0x02 frequency input IN11: duty cycle of the signal in %o |
| 0x03 PDO mapping | rw USINT 0x2014 0310 Index 0x2014, SubIndex 0x03 frequency input IN13: duty cycle of the signal in %o |
| 0x04 PDO mapping | rw USINT 0x2014 0410 Index 0x2014, SubIndex 0x04 frequency input IN15: duty cycle of the signal in %o |
| 0x1A07 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x02 mapping transmit | PDO 8 (frequency on IN09, IN11) number of integrated application objects = 2 |
| 0x01 PDO mapping | rw USINT 0x2015 0120 Index 0x2015, SubIndex 0x01 frequency input IN09: frequency value of the signal in Hz |
| 0x02 PDO mapping | rw USINT 0x2015 0220 Index 0x2015, SubIndex 0x02 frequency input IN11: frequency value of the signal in Hz |
| 0x1A08 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x02 mapping transmit | PDO 9 (frequency on IN13, IN15) number of integrated application objects = 2 |
| 0x01 PDO mapping | rw USINT 0x2015 0320 Index 0x2015, SubIndex 0x03 frequency input IN13: frequency value of the signal in Hz |
| 0x02 PDO mapping | rw USINT 0x2015 0420 Index 0x2015, SubIndex 0x04 frequency input IN15: frequency value of the signal in Hz |
| Index S-index Design Data type Default Details | |
| 0x1A09 0x00 TransmitPDO map-pingNumber ofmappedobjects inPDO | rw USINT 0x02 mapping transmit | PDO 10 (systemflag)number of integrated applicationobjects = 2 |
| 0x01 PDO map-ping | rw U DINT 0x204 00110 Index 0x2040, SubIndex 0x01supply voltage of the system VBSS |
| 0x02 PDO map-ping | rw U DINT 0x205 00010 Index 0x2050, SubIndex 0x00system temperature in °C |
| Index S-index Design Data type Default Details | |
| 0x2000 0x00 IO configuration Largest sub-index supported | ro USINT 16 Configuration inputs | outputs largest supported Sub-index = 32 |
| 0x01 Configuration IN00 | rw USINT 10 0 = 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0x0A11 = 0x0B12 = 0x0C | off Input IN000...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched |
| 0x02 Configuration IN01 | rw USINT 10 0 = 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0x0A11 = 0x0B12 = 0x0C | off Input IN010...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched |
| 0x03 Configuration IN02 | rw USINT 10 0 = 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0x0A11 = 0x0B12 = 0x0C | off Input IN020...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched |
| Index Sidx Designation Data type Default Details | |
| 0x2000 | 0x04 ConfigurationIN03 | rw USINT 10 0 = | 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0xA11 = 0xB12 = 0xC | off Input IN030...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched | |
| 0x05 ConfigurationIN04 | rw USINT 10 0 = | 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0xA11 = 0xB12 = 0xC | off Input IN040...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched | |
| 0x06 ConfigurationIN05 | rw USINT 10 0 = | 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0xA11 = 0xB12 = 0xC | off Input IN050...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched | |
| 0x07 ConfigurationIN06 | rw USINT 10 0 = | 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0xA11 = 0xB12 = 0xC | off Input IN060...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched | |
| 0x08 ConfigurationIN07 | rw USINT 10 0 = | 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0xA11 = 0xB12 = 0xC | off Input IN070...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched | |
| 0x09 ConfigurationIN08 | rw USINT 10 0 = | 0x00 | 10 = 0xA11 = 0xB18 = 0x12 | off Input IN08binary plus switched binary plus switched with diagnosis 16...30 000 Ohm | |
| Index S-index Design Data type Default Details | |
| 0x2000 | 0x0A Configuration IN09 | rw USINT 01 0 = 0x00 | 01 = 0x0114 = 0xE20 = 0x14 | off Input IN09 binary plus switched frequency0...30 000 Hz period duration |
| 0x0B Configuration IN10 | rw USINT 10 0 = 0x00 | 10 = 0xA11 = 0xB18 = 0x12 | off Input IN10 binary plus switched binary plus switched with diagnosis16...30 000 Ohm |
| 0x0C Configuration IN11 | rw USINT 01 0 = 0x00 | 01 = 0x0114 = 0xE20 = 0x14 | off Input IN11 binary plus switched frequency0...30 000 Hz period duration |
| 0x0D Configuration IN12 | rw USINT 10 0 = 0x00 | 10 = 0xA11 = 0xB18 = 0x12 | off Input IN12 binary plus switched binary plus switched with diagnosis16...30 000 Ohm |
| 0x0E Configuration IN13 | rw USINT 01 0 = 0x00 | 01 = 0x0114 = 0xE20 = 0x14 | off Input IN12 binary plus switched frequency0...30 000 Hz period duration |
| 0x0F Configuration IN14 | rw USINT 10 0 = 0x00 | 10 = 0xA11 = 0xB18 = 0x12 | off Input IN14 binary plus switched binary plus switched with diagnosis16...30 000 Ohm |
| 0x10 Configuration IN15 | rw USINT 01 0 = 0x00 | 01 = 0x0114 = 0xE20 = 0x14 | off Input IN15 binary plus switched frequency0...30 000 Hz period duration |
| 0x2012 | 0x00 Period input ro USINT 4 | Largest subindex supported |
| 0x01 Period durati-on IN09 | ro | UDINT | 0 | IN09 period duration [μs] |
| 0x02 Period durati-on IN11 | ro | UDINT | 0 | IN11 period duration [μs] |
| 0x03 Period durati-on IN13 | ro | UDINT | 0 | IN13 period duration [μs] |
| 0x04 Period durati-on IN15 | ro | UDINT | 0 | IN15 period duration [μs] |
| Index Sidx Designation Data type | Default Details | |
| 0x2013 0x00 Period input number of periods for average | ro USINT 4 Largest sub-index supported |
| 0x01 Numb der input number of periods IN09 | rw USINT 4 1...255 IN09 number of | periods |
| 0x02 Numb der input period sIN11 | rw USINT 4 1...255 IN11 number of | periods |
| 0x03 Numb der input period sIN13 | rw USINT 4 1...255 IN13 number of | periods |
| 0x04 Numb der input period sIN15 | rw USINT 4 1...255 IN15 number of | periods |
| 0x2014 0x00 Period input - ratio value | ro USINT 4 Largest sub-index supported |
| 0x01 Period ratio value IN09 | ro UINT 0 0...1 000 IN09 marc-to-space | ratio [%] |
| 0x02 Period ratio value IN11 | ro UINT 0 0...1 000 IN11 marc-to-space | ratio [%] |
| 0x03 Period ratio value IN13 | ro UINT 0 0...1 000 IN13 marc-to-space | ratio [%] |
| 0x04 Period ratio value IN15 | ro UINT 0 0...1 000 IN15 marc-to-space | ratio [%] |
| 0x2015 0x00 Frequency input | ro USINT 4 Largest sub-index supported |
| 0x01 Frequency IN09 | ro REAL 1 0...30 000 IN09 frequency [Hz] | |
| 0x02 Frequency IN11 | ro REAL 1 0...30 000 IN11 frequency [Hz] | |
| 0x03 Frequency IN13 | ro REAL 1 0...30 000 IN13 frequency [Hz] | |
| 0x04 Frequency IN15 | ro REAL 1 0...30 000 IN15 frequency [Hz] | |
| 0x2016 0x00 Timebase ro USINT 4 Largest sub-index supported |
| 0x01 Timebase IN09 | rw UINT 50 | 0...2 000 IN09 timebase [ms] |
| 0x02 Timebase IN11 | rw UINT 50 | 0...2 000 IN11 timebase [ms] |
| 0x03 Timebase IN13 | rw UINT 50 | 0...2 000 IN13 timebase [ms] |
| 0x04 Timebase IN15 | rw UINT 50 | 0...2 000 IN15 timebase [ms] |
| Index S-index Design Data type Default Details | |
| 0x1600 0x00 Receive PDO mapping Number of mapped objects in PDO | rw USINT 0x02 | Mapping read PDO | DO 1: binary outputs number of integrated application objects = 2 |
| 0x01 PDO mapping | ro UDINT 0x6200 | 0108 1 byte in | index 0x6200, SubIndex 01 Binary outputs OUT00...OUT070b---- ---X = OUT000b---- -X- = OUT010b---- -X-- = OUT020b---- X--- = OUT030b---- X---- = OUT040b--X---- = OUT050b-X---- = OUT060bX---- = OUT07 | |
| 0x02 PDO mapping | ro UDINT 0x6200 | 0208 1 byte in | index 0x6200, SubIndex 02 Binary outputs OUT08...OUT150b---- ---X = OUT080b---- -X- = OUT090b---- -X-- = OUT100b---- X--- = OUT110b---- X---- = OUT120b--X---- = OUT130b-X---- = OUT140bX---- = OUT15 | |
| Index S-idx Design Data type Default Details | |
| 0x1601 0x00 Receive PDO mapping Number of mapped objects in PDO | rw USINT 0x04 | Mapping read PDO 2: PWM outputs OUT00...OUT03 number of integrated application objects = 4 |
| 0x01 PDO mapping | rw U DINT 0x641 | 4 0110 PWM/current output OUT00 Index 0x6414, SubIndex 0x01 contains the preset value of the PWM output OUT00, the value is interpreted as duty cycle in %o or as target current value (depending on the configuration index 0x2000) |
| 0x02 PDO mapping | rw U DINT 0x641 | 4 0210 PWM/current output OUT01 Index 0x6414, SubIndex 0x02 contains the preset value of the PWM output OUT01, the value is interpreted as duty cycle in %o or as target current value (depending on the configuration index 0x2000) |
| 0x03 PDO mapping | rw U DINT 0x641 | 4 0310 PWM/current output OUT02 Index 0x6414, SubIndex 0x03 contains the preset value of the PWM output OUT02, the value is interpreted as duty cycle in %o or as target current value (depending on the configuration index 0x2000) |
| 0x04 PDO mapping | rw U DINT 0x641 | 4 0410 PWM/current output OUT03 Index 0x6414, SubIndex 0x04 contains the preset value of the PWM output OUT03, the value is interpreted as duty cycle in %o or as target current value (depending on the configuration index 0x2000) |
| 0x1602 0x00 "ReceivePDO map-pingNumber ofmappedobjects inPDO" | rw USINT 0x04 | Mapping read PDO 3: PWM outputs OUT04...OUT07number of integrated applicationobjects = 4 |
| 0x01 PDO map-ping | rw U DINT 0x641 | 4 0510 PWM/ current output OUT04Index 0x6414, SubIndex 0x05contains the preset value of thePWM output OUT04, the value isinterpreted as duty cycle in %o or astarget current value (depending onthe configuration index 0x2000) |
| 0x02 PDO map-ping | rw U DINT 0x641 | 4 0610 PWM/ current output OUT05Index 0x6414, SubIndex 0x06contains the preset value of thePWM output OUT05, the value isinterpreted as duty cycle in %o or astarget current value (depending onthe configuration index 0x2000) |
| 0x03 PDO map-ping | rw U DINT 0x641 | 4 0710 PWM/ current output OUT06Index 0x6414, SubIndex 0x07contains the preset value of thePWM output OUT06, the value isinterpreted as duty cycle in %o or astarget current value (depending onthe configuration index 0x2000) |
| 0x04 PDO map-ping | rw U DINT 0x641 | 4 0810 PWM/ current output OUT07Index 0x6414, SubIndex 0x08contains the preset value of thePWM output OUT07, the value isinterpreted as duty cycle in %o or astarget current value (depending onthe configuration index 0x2000) |
| 0x1603 0x00 Receive PDO mapping Number of mapped objects in PDO | rw USINT 0x04 | Mapping read PDO 4: PWM outputs OUT08...OUT11 number of integrated application objects = 4 |
| 0x01 PDO mapping | rw U DINT 0x641 | 4 0910 PWM/ current output OUT08 Index 0x6414, SubIndex 0x09 contains the preset value of the PWM output OUT08, the value is interpreted as duty cycle in %o or as target current value (depending on the configuration index 0x2000) |
| 0x02 PDO mapping | rw U DINT 0x641 | 4 0A10 PWM/ current output OUT09 Index 0x6414, SubIndex 0x0A contains the preset value of the PWM output OUT09, the value is interpreted as duty cycle in %o or as target current value (depending on the configuration index 0x2000) |
| 0x03 PDO mapping | rw U DINT 0x641 | 4 0B10 PWM/ current output OUT10 Index 0x6414, SubIndex 0x0B contains the preset value of the PWM output OUT10, the value is interpreted as duty cycle in %o or as target current value (depending on the configuration index 0x2000) |
| 0x04 PDO mapping | rw U DINT 0x641 | 4 0C10 PWM/ current output OUT11 Index 0x6414, SubIndex 0x0C contains the preset value of the PWM output OUT11, the value is interpreted as duty cycle in %o or as target current value (depending on the configuration index 0x2000) |
| Index S-index Design Data type Default Details | |
| 0x1800 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 1number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x180 +Node ID | CAN ID of the transmit PDO 1Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UINT 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event timerw UINT 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index Sidx Designation Data type Default Details | |
| 0x1801 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 2number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x280 +Node ID | CAN ID of the transmit PDO 2Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UINT 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UINT 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| 0x1802 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 3number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x380 +Node ID | CAN ID of the transmit PDO 3Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| 0x1803 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 4number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x480 +Node ID | CAN ID of the transmit PDO 4Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xFD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event timerw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index S-index Design Data type Default Details | |
| 0x1A00 0x00 TransmitPDO mappingNumber ofmappedobjects inPDO | rw USINT 0x04 mapping transmit | PDO 01 (output current OUT00...OUT03) number of integrated application objects = 4 |
|
| 0x01 PDO mapping | rw UDINT 0x2002 0110 Index 0x2002, SubIndex 0x01 current on output OUT00 |
| 0x02 PDO mapping | rw UDINT 0x2002 0210 Index 0x2002, SubIndex 0x02 current on output OUT01 |
| 0x03 PDO mapping | rw UDINT 0x2002 0310 Index 0x2002, SubIndex 0x03 current on output OUT02 |
| 0x04 PDO mapping | rw UDINT 0x2002 0410 Index 0x2002, SubIndex 0x04 current on output OUT03 |
| 0x1A01 0x00 TransmitPDO mappingNumber ofmappedobjects inPDO | rw USINT 0x04 mapping transmit | PDO 02 (output current OUT04...OUT07) number of integrated application objects = 4 |
|
| 0x01 PDO mapping | rw UDINT 0x2002 0510 Index 0x2002, SubIndex 0x05 current on output OUT04 |
| 0x02 PDO mapping | rw UDINT 0x2002 0610 Index 0x2002, SubIndex 0x06 current on output OUT05 |
| 0x03 PDO mapping | rw UDINT 0x2002 0710 Index 0x2002, SubIndex 0x07 current on output OUT06 |
| 0x04 PDO mapping | rw UDINT 0x2002 0810 Index 0x2002, SubIndex 0x08 current on output OUT07 |
| Index S-index Design Data type | Default Details | |
| 0x1A02 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x05 | mapping transmit | PDO 3number of integrated applicationobjects = 5 | |
| 0x01 PDO mapping | rw UDINT 0x202 | 20108 Index 0x2 | 2022, SubIndex 0x01outputs 00...07: flag " short circuit " (bit coded) | |
| 0x02 PDO mapping | rw UDINT 0x202 | 20208 Index 0x2 | 2022, SubIndex 0x02outputs 08...15: flag " short circuit " (bit coded) | |
| 0x03 PDO mapping | rw UDINT 0x202 | 30108 Index 0x2 | 2023, SubIndex 0x01outputs 00...07: flag " wire break " (bit coded) | |
| 0x04 PDO mapping | rw UDINT 0x202 | 30208 Index 0x2 | 2023, SubIndex 0x02outputs 08...015: flag " wire break " (bit coded) | |
| 0x05 PDO mapping | rw UDINT 0x202 | 40108 Index 0x2 | 2024, SubIndex 0x01outputs 00...07: flag " overload " (bit coded) | |
| 0x1A03 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x04 | mapping transmit | PDO 4 (systemflag)number of integrated applicationobjects = 4 | |
| 0x01 PDO mapping | rw UDINT 0x204 | 0110 Index 0x2 | 2040, SubIndex 0x01supply voltage of the system VBBS | |
| 0x02 PDO mapping | rw UDINT 0x204 | 10110 Index 0x2 | 2041, SubIndex 0x01output supply voltage VBB1 | |
| 0x03 PDO mapping | rw UDINT 0x204 | 10210 Index 0x2 | 2041, SubIndex 0x02output supply voltage VBB2 | |
| 0x04 PDO mapping | rw UDINT 0x205 | 0010 Index 0x2 | 2050, SubIndex 0x00system temperature in °C | |
| Index Sidx Designation Data type Default Details | |
| 0x2004 0x00 P-value ro USINT 8 | Large sub-index supported | | |
| 0x01 P-value OUT00 | rw USINT 30 0... | 255 OUT00 P-value for current control | |
| 0x02 P-value OUT01 | rw USINT 30 0... | 255 OUT01 P-value for current control | |
| 0x03 P-value OUT02 | rw USINT 30 0... | 255 OUT02 P-value for current control | |
| 0x04 P-value OUT03 | rw USINT 30 0... | 255 OUT03 P-value for current control | |
| 0x05 P-value OUT04 | rw USINT 30 0... | 255 OUT04 P-value for current control | |
| 0x06 P-value OUT05 | rw USINT 30 0... | 255 OUT05 P-value for current control | |
| 0x07 P-value OUT06 | rw USINT 30 0... | 255 OUT06 P-value for current control | |
| 0x08 P-value OUT07 | rw USINT 30 0... | 255 OUT07 P-value for current control | |
| 0x00 I-value ro USINT 8 Largest sub-index supported | |
| 0x01 I-value OUT00 | rw USINT 20 0... | 255 OUT00 I-value for current control | |
| 0x02 I-value OUT01 | rw USINT 20 0... | 255 OUT01 I-value for current control | |
| 0x03 I-value OUT02 | rw USINT 20 0... | 255 OUT02 I-value for current control | |
| 0x04 I-value OUT03 | rw USINT 20 0... | 255 OUT03 I-value for current control | |
| 0x05 I-value OUT04 | rw USINT 20 0... | 255 OUT04 I-value for current control | |
| 0x06 I-value OUT05 | rw USINT 20 0... | 255 OUT05 I-value for current control | |
| 0x07 I-value OUT06 | rw USINT 20 0... | 255 OUT06 I-value for current control | |
| 0x08 I-value OUT07 | rw USINT 20 0... | 255 OUT07 I-value for current control | |
| 0x00 PWM dither frequency | ro USINT 16 Largest sub-index supported | |
| 0x01 PWM dither frequency OUT00 | rw INT 0 0...PWM- | freq / 2 | OUT00 PWM dither frequency [Hz] | |
| 0x02 PWM dither frequency OUT01 | rw INT 0 0...PWM- | freq / 2 | OUT01 PWM dither frequency [Hz] | |
| Index S-index Design Data type Default Details |
| 0x2006 | 0x03 PWM dither frequency OUT02 | rw UINT 0 0...PWM- | freq / 2 | OUT02 PWM dither frequency [Hz] | |
| 0x04 PWM dither frequency OUT03 | rw UINT 0 0...PWM- | freq / 2 | OUT03 PWM dither frequency [Hz] | |
| 0x05 PWM dither frequency OUT04 | rw UINT 0 0...PWM- | freq / 2 | OUT04 PWM dither frequency [Hz] | |
| 0x06 PWM dither frequency OUT05 | rw UINT 0 0...PWM- | freq / 2 | OUT05 PWM dither frequency [Hz] | |
| 0x07 PWM dither frequency OUT06 | rw UINT 0 0...PWM- | freq / 2 | OUT06 PWM dither frequency [Hz] | |
| 0x08 PWM dither frequency OUT07 | rw UINT 0 0...PWM- | freq / 2 | OUT07 PWM dither frequency [Hz] | |
| 0x09 PWM dither frequency OUT08 | rw UINT 0 0...PWM- | freq / 2 | OUT08 PWM dither frequency [Hz] | |
| 0x0A PWM dither frequency OUT09 | rw UINT 0 0...PWM- | freq / 2 | OUT09 PWM dither frequency [Hz] | |
| 0x0B PWM dither frequency OUT10 | rw UINT 0 0...PWM- | freq / 2 | OUT10 PWM dither frequency [Hz] | |
| 0x0C PWM dither frequency OUT11 | rw UINT 0 0...PWM- | freq / 2 | OUT11 PWM dither frequency [Hz] | |
| 0x0D PWM dither frequency OUT12 | rw UINT 0 0...PWM- | freq / 2 | OUT12 PWM dither frequency [Hz] | |
| 0x0E PWM dither frequency OUT13 | rw UINT 0 0...PWM- | freq / 2 | OUT13 PWM dither frequency [Hz] | |
| 0x0F PWM dither frequency OUT14 | rw UINT 0 0...PWM- | freq / 2 | OUT14 PWM dither frequency [Hz] | |
| 0x10 PWM dither frequency OUT15 | rw UINT 0 0...PWM- | freq / 2 | OUT15 PWM dither frequency [Hz] | |
| Index S-index Design Data type Default Details |
| 0x2007 0x00 PWM dither value | ro USINT 16 Largest sub-index supported |
| 0x01 PWM dither value OUT00 | rw UINT 0 0...1 000 OUT00 PWM dither | value [%] | |
| 0x02 PWM dither value OUT01 | rw UINT 0 0...1 000 OUT01 PWM dither | value [%] | |
| 0x03 PWM dither value OUT02 | rw UINT 0 0...1 000 OUT02 PWM dither | value [%] | |
| 0x04 PWM dither value OUT03 | rw UINT 0 0...1 000 OUT03 PWM dither | value [%] | |
| 0x05 PWM dither value OUT04 | rw UINT 0 0...1 000 OUT04 PWM dither | value [%] | |
| 0x06 PWM dither value OUT05 | rw UINT 0 0...1 000 OUT05 PWM dither | value [%] | |
| 0x07 PWM dither value OUT06 | rw UINT 0 0...1 000 OUT06 PWM dither | value [%] | |
| 0x08 PWM dither value OUT07 | rw UINT 0 0...1 000 OUT07 PWM dither | value [%] | |
| 0x09 PWM dither value OUT08 | rw UINT 0 0...1 000 OUT08 PWM dither | value [%] | |
| 0x0A PWM dither value OUT09 | rw UINT 0 0...1 000 OUT09 PWM dither | value [%] | |
| 0x0B PWM dither value OUT10 | rw UINT 0 0...1 000 OUT10 PWM dither | value [%] | |
| 0x0C PWM dither value OUT11 | rw UINT 0 0...1 000 OUT11 PWM dither | value [%] | |
| 0x0D PWM dither value OUT12 | rw UINT 0 0...1 000 OUT12 PWM dither | value [%] | |
| 0x0E PWM dither value OUT13 | rw UINT 0 0...1 000 OUT13 PWM dither | value [%] | |
| 0x0F PWM dither value OUT14 | rw UINT 0 0...1 000 OUT14 PWM dither | value [%] | |
| 0x10 PWM dither value OUT15 | rw UINT 0 0...1 000 OUT15 PWM dither | value [%] | |
| Index S-index Design Data type Default Details | |
| 0x1800 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 1number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x180 +Node ID | CAN ID of the transmit PDO 1Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UINT 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event timerw UINT 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index Sidx Designation Data type Default Details | |
| 0x1801 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 2number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x280 +Node ID | CAN ID of the transmit PDO 2Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UINT 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UINT 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index S-index Design Data type Default Details | |
| 0x1802 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 3number of entries = 5 |
| 0x01 OBID usedby PDO | rw USINT 0x380 +Node ID | CAN ID of the transmit PDO 3Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UINT 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event timerw UINT 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index Sidx Designation Data type Default Details | |
| 0x1803 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 4number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x480 +Node ID | CAN ID of the transmit PDO 4Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xFD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index S-index Design Data type Default Details | |
| 0x1804 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 5number of entries = 5 |
| 0x01 OBID usedby PDO | rw USINT 0x181 +Node ID | CAN ID of the transmit PDO 5Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UINT 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event timerw UINT 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index Sidx Designation Data type Default Details | |
| 0x1805 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 6number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x281 +Node ID | CAN ID of the transmit PDO 6Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| 0x1806 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 7number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x381 +Node ID | CAN ID of the transmit PDO 7Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| 0x1807 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 8number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x481 +Node ID | CAN ID of the transmit PDO 8Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xFD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index S-index Design Data type Default Details | |
| 0x1808 0x00 TransmitPDO CommunicationParameterNumber ofentries | ro USINT 0x05 Configuration transmits PIO9number of entries = 5 |
| 0x01 OBID usedby PDO | rw USINT 0x182 +Node ID | CAN ID of the transmit PDO 9Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UINT 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event timerw UINT 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index Sidx Designation Data type Default Details | |
| 0x1809 0x00 TransmitPDO Com-municationParameterNumber ofentries | ro USINT 0x05 Configuration transmit PDO 10number of entries = 5 |
| 0x01 COBID usedby PDO | rw USINT 0x282 +Node ID | CAN ID of the transmit PDO 10Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 delay time inthe transmission | type "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 reserve | |
| 0x05 event time | rw UART 0 max. transfer break in thetransmissi-on type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index S-index Design Data type Default Details | |
| 0x180A | 0x00 TransmitPDO CommunicationParameterNumber ofentries | ro USINT 0x05 Configuration transmits PIO 11number of entries = 5 |
| 0x01 OBID usedby PDO | rw USINT 0x382 +Node ID | CAN ID of the transmit PDO 11Bit 31 = 0 → PDO is validBit 31 = 1 → PDO is not valid |
| 0x02 transmissiontype | rw USINT 0x01 0x00 = synch acyclic0x01...0xF0 = synch cyclic; valuesare only transmitted after „n" synchobjectsn = 1...240 = 0x01...0xF00xFC/0xCD not implemented0xFE = asynch man. spec. event;values are immediately transferred0xFF = asynch device profile event;values are immediately transferred |
| 0x03 inhibit time rw UART 0 | | delay time in the transmissiontype "asynch" before the PDO istransmitted again at the earliest.(0...65535 · 100 μs) |
| 0x04 reserved rw USINT 0 | | reserve | |
| 0x05 event time rw UART 0 | max. transferbreak in the transmis-sion type „asynch" (0...65535 ms)When this time has elapsed, the PDOis transferred even if the appl. eventhas not accured. |
| Index S-index Design Data type Default Details | |
| 0x1A00 | 0x00 TransmitPDO map-pingNumber of mapped objects in PDO | rw USINT 0x07 mapping transmit | PDO 1number of integrated applicationobjects = 7 |
| 0x01 PDO map-ping | rw USINT 0x60000108 Index 0x6000, SubIndex 0x01binary inputs 00...07: actual values(bit coded) |
| 0x02 PDO map-ping | rw USINT 0x2020108 Index 0x2020, SubIndex 0x01binary inputs 00...07: flag "shortcircuit" (bit coded) |
| 0x03 PDO map-ping | rw USINT 0x2021018 Index 0x2021, SubIndex 0x01binary inputs 00...07: flag "wire break"(bit coded) |
| 0x04 PDO map-ping | rw USINT 0x20250108 Index 0x2025, SubIndex 0x01inputs 00, 01, 02 und 03: flag "over-load" (bit coded) |
| 0x05 PDO map-ping | rw USINT 0x20220108 Index 0x2022, SubIndex 0x01outputs 00...07: flag " short circuit"(bit coded) |
| 0x06 PDO map-ping | rw USINT 0x20230108 Index 0x2023, SubIndex 0x01outputs 00...07: flag " wire break " (bit coded) |
| 0x07 PDO map-ping | rw USINT 0x20240108 Index 0x2024, SubIndex 0x01outputs 00...07: flag " overload " (bit coded) |
| 0x1A01 | 0x00 TransmitPDO map-pingNumber of mapped objects in PDO | rw USINT 0x04 mapping transmit | PDO 2 (analogue inputs)number of integrated application objects = 4 | |
| 0x01 DO map-ping | rw U DINT 0x6404 0110 Index 0x6404, SubIndex 0x01 analogue input 00: actual value (depending on the configuration 0x2000) | |
| 0x02 DO map-ping | rw U DINT 0x6404 0210 Index 0x6404, SubIndex 0x02 analogue input 01: actual value (depending on the configuration 0x2000)) | |
| 0x03 DO map-ping | rw U DINT 0x6404 0310 Index 0x6404, SubIndex 0x03 analogue input 02: actual value (depending on the configuration 0x2000) | |
| 0x04 DO map-ping | rw U DINT 0x6404 0410 Index 0x6404, SubIndex 0x04 analogue input 03: actual value (depending on the configuration 0x2000) | |
| 0x1A02 | 0x00 TransmitPDO map-pingNumber of mapped objects in PDO | rw USINT 0x04 mapping transmit | PDO 3 number of integrated application objects = 4 | |
| 0x01 DO map-ping | rw U DINT 0x2030 0110 Index 0x2030, SubIndex 0x01 input 04: actual resistor value | |
| 0x02 PDO map-ping | rw U DINT 0x2030 0210 Index 0x2030, SubIndex 0x02 input 05: actual resistor value | |
| 0x03 PDO map-ping | rw U DINT 0x2030 0310 Index 0x2030, SubIndex 0x03 input 06: actual resistor value | |
| 0x04 PDO map-ping | rw U DINT 0x2030 0410 Index 0x2030, SubIndex 0x04 input 07: actual resistor value | |
| 0x1A03 | 0x00 TransmitPDO mappingNumber of mapped objects inPDO | rw USINT 0x02 mapping transmit | PDO 4 (periode time IN00...IN01) number of integrated application objects = 2 |
| 0x01 PDO mapping | rw USINT 0x2012 0120 Index 0x2012, SubIndex 0x01 frequency input IN00: periode time of the signal |
| 0x02 PDO mapping | rw USINT 0x2012 0220 Index 0x2012, SubIndex 0x02 frequency input IN01: periode time of the signal |
| 0x1A04 | 0x00 TransmitPDO mappingNumber of mapped objects inPDO | rw USINT 0x02 mapping transmitPDO 5 (periode time IN02...IN03) number of integrated application objects = 2 |
| 0x01 PDO mapping | rw USINT 0x2012 0320 Index 0x2012, SubIndex 0x03 frequency input IN02: periode time of the signal |
| 0x02 PDO mapping | rw USINT 0x2012 0420 Index 0x2012, SubIndex 0x04 frequency input IN03: periode time of the signal |
| 0x1A05 | 0x00 TransmitPDO mappingNumber of mapped objects inPDO | rw USINT 0x04 mapping transmitPDO 6 (duty cycle of the signal on the frequency input IN00, IN01, IN02, IN03) number of integrated application objects = 4 |
| 0x01 PDO mapping | rw USINT 0x2014 0110 Index 0x2014, SubIndex 0x01 frequency input IN00: duty cycle of the signal in‰ |
| 0x02 PDO mapping | rw USINT 0x2014 0210 Index 0x2014, SubIndex 0x02 frequency input IN01: duty cycle of the signal in‰ |
| 0x03 PDO mapping | rw USINT 0x2014 0310 Index 0x2014, SubIndex 0x03 frequency input IN02: duty cycle of the signal in‰ |
| 0x04 PDO mapping | rw USINT 0x2014 0410 Index 0x2014, SubIndex 0x04 frequency input IN03: duty cycle of the signal in‰ |
| 0x1A06 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x02 mapping transmit | PDO 7 (frequencyon IN00...IN01)number of integrated applicationobjects = 2 | |
| 0x01 PDO mapping | rw USINT 0x2015 0120 Index 0x2015, SubIndex 0x01frequency input IN00: frequencyvalue of the signal in Hz | |
| 0x02 PDO mapping | rw USINT 0x2015 0220 Index 0x2015, SubIndex 0x02frequency input IN01: frequencyvalue of the signal in Hz | |
| 0x1A07 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x02 mapping transmit | PDO 8 (frequencyon IN02...IN03)number of integrated applicationobjects = 2 | |
| 0x01 PDO mapping | rw USINT 0x2015 0320 Index 0x2015, SubIndex 0x03frequency input IN02: frequencyvalue of the signal in Hz | |
| 0x02 PDO mapping | rw USINT 0x2015 0420 Index 0x2015, SubIndex 0x04frequency input IN03: frequencyvalue of the signal in Hz | |
| 0x1A08 | 0x00 TransmitPDO mappingNumber of mapped objects in PDO | rw USINT 0x04 mapping transmit | PDO 9 (outputcurrent OUT00...OUT03)number of integrated applicationobjects = 4 | |
| 0x01 PDO mapping | rw USINT 0x2002 0110 Index 0x2002, SubIndex 0x01current on output OUT00 | |
| 0x02 PDO mapping | rw USINT 0x2002 0210 Index 0x2002, SubIndex 0x02current on output OUT01 | |
| 0x03 PDO mapping | rw USINT 0x2002 0310 Index 0x2002, SubIndex 0x03current on output OUT02 | |
| 0x04 PDO mapping | rw USINT 0x2002 0410 Index 0x2002, SubIndex 0x04current on output OUT03 | |
| Index Sidx Designation Data type Default Details | |
| 0x1A09 0x00 TransmitPDO map- pingNumber of mapped objects in PDO | rw USINT 0x04 mapping transmit | PDO 10 (output current OUT04...OUT07) number of integrated application objects = 4 |
|
| 0x01 PDO map- ping | rw UDDINT 0x2002 0510 Index 0x2002, SubIndex 0x05 current on output OUT04 |
| 0x02 PDO map- ping | rw UDDINT 0x2002 0610 Index 0x2002, SubIndex 0x06 current on output OUT05 |
| 0x03 PDO map- ping | rw UDDINT 0x2002 0710 Index 0x2002, SubIndex 0x07 current on output OUT06 |
| 0x04 PDO map- ping | rw UDDINT 0x2002 0810 Index 0x2002, SubIndex 0x08 current on output OUT07 |
| 0x1A0A 0x00 TransmitPDO map- pingNumber of mapped objects in PDO | rw USINT 0x03 mapping transmit | PDO 11 (system flag) number of integrated application objects = 4 |
| 0x01 PDO map- ping | rw UDDINT 0x2040 0110 Index 0x2040, SubIndex 0x01 supply voltage of the system VBB5 |
| 0x02 PDO map- ping | rw UDDINT 0x2041 0110 Index 0x2041, SubIndex 0x01 output supply voltage VBB2 |
| 0x03 PDO map- ping | rw UDDINT 0x2050 0010 Index 0x2050, SubIndex 0x00 system temperature in °C |
| Index S-index Design Data type Default Details |
| 0x2000 | 0x00 IO | configuration | ro USINT 16 Configuration inputs | outputs largest supported Sub-index = 32 |
| Largest sub-index supported |
| 0x01 Configuration IN00 | rw USINT 10 0 = 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0x0A11 = 0x0B12 = 0x0C14 = 0x0E20 = 0x14 | off Input IN000...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched frequency0...30 000 Hz period duration as ratio 0...1 000 % |
| 0x02 Configuration IN01 | rw USINT 10 0 = 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0x0A11 = 0x0B12 = 0x0C14 = 0x0E20 = 0x14 | off Input IN010...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched frequency0...30 000 Hz period duration as ratio 0...1 000 % |
| 0x03 Configuration IN02 | rw USINT 10 0 = 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0x0A11 = 0x0B12 = 0x0C14 = 0x0E20 = 0x14 | off Input IN020...10 000 mV ratiometric 0...1000 %0...20 000 μA0...32 000 mV binary plus switched binary plus switched with diagnosis binary minus switched frequency0...30 000 Hz period duration as ratio 0...1 000 % |
| Index S-index Design Data type Default Details |
| 0x2000 0x04 Configuration IN03 | rw USINT 10 0 = 0x00 | 3 = 0x036 = 0x067 = 0x079 = 0x0910 = 0x0A11 = 0x0B12 = 0x0C14 = 0x0E20 = 0x14 | off Input IN030...10 000 mVratiometric 0...1000 %0...20 000 μAB0...32 000 mVbinary plus switched binary plus switched with diagnosis binary minus switched frequency0...30 000 Hzperiod duration as ratio 0...1 000 %。 | | |
| 0x05 Configuration IN04 | rw USINT 10 0 = 0x00 | 10 = 0x0A11 = 0x0B18 = 0x12 | off Input IN04binary plus switched binary plus switched with diagnosis16...30 000 Ohm | | |
| 0x06 Configuration IN05 | rw USINT 10 0 = 0x00 | 10 = 0x0A11 = 0x0B18 = 0x12 | off Input IN05binary plus switched binary plus switched with diagnosis16...30 000 Ohm | | |
| 0x07 Configuration IN06 | rw USINT 10 0 = 0x00 | 10 = 0x0A11 = 0x0B18 = 0x12 | off Input IN06binary plus switched binary plus switched with diagnosis16...30 000 Ohm | | |
| 0x08 Configuration IN07 | rw USINT 10 0 = 0x00 | 10 = 0x0A11 = 0x0B18 = 0x12 | off Input IN07binary plus switched binary plus switched with diagnosis16...30 000 Ohm | | |
| 0x09 Configuration OUT00 | rw USINT 2 0 = 0x00 | 2 = 0x024 = 0x045 = 0x0515 = 0x0F16 = 0x10 | off Output OUT00binary plus switched PWM output current control binary plus switched with diagnosis binary plus switched with diagnosis + protection | | |
| Index S-index Design Data type Default Details |
| 0x2000 | 0x0A Configuration OUT01 | rw USINT 2 0 = 0x00 | 2 = 0x024 = 0x045 = 0x0515 = 0xF16 = 0x10 | off Output OUT01 binary plus switched PWM output current control binary plus switched with diagnosis binary plus switched with diagnosis + protection |
| 0x0B Configuration OUT02 | rw USINT 2 0 = 0x00 | 2 = 0x024 = 0x045 = 0x0515 = 0xF16 = 0x10 | off Output OUT02 binary plus switched PWM output current control binary plus switched with diagnosis binary plus switched with diagnosis + protection |
| 0x0C Configuration OUT03 | rw USINT 2 0 = 0x00 | 2 = 0x024 = 0x045 = 0x0515 = 0xF16 = 0x10 | off Output OUT03 binary plus switched PWM output current control binary plus switched with diagnosis binary plus switched with diagnosis + protection |
| 0x0D Configuration OUT04 | rw USINT 2 0 = 0x00 | 2 = 0x024 = 0x045 = 0x0515 = 0xF16 = 0x10 | off Output OUT04 binary plus switched PWM output current control binary plus switched with diagnosis binary plus switched with diagnosis + protection |
| 0x0E Configuration OUT05 | rw USINT 2 0 = 0x00 | 2 = 0x024 = 0x045 = 0x0515 = 0xF16 = 0x10 | off Output OUT05 binary plus switched PWM output current control binary plus switched with diagnosis binary plus switched with diagnosis + protection |
| Index S-index Designation Data type | pe Default Details | | |
| 0x2000 | 0x0F Configuration OUT06 | rw USINT 2 0 = 0x00 | 2 = 0x024 = 0x045 = 0x0515 = 0x0F16 = 0x10 | off Output OUT06 binary plus switched PWM output current control binary plus switched with diagnosis binary plus switched with diagnosis + protection |
| 0x10 Configuration OUT07 | rw USINT 2 0 = 0x00 | 2 = 0x024 = 0x045 = 0x0515 = 0x0F16 = 0x10 | off Output OUT07 binary plus switched PWM output current control binary plus switched with diagnosis binary plus switched with diagnosis + protection |
| 0x2001 | 0x00 PWM fre-quency | ro USINT 8 Largest sub-index supported |
| 0x01 PWM frequency OUT00 | rw USINT 100 20...250 OUT00 PWM frequen- | cy [Hz] |
| 0x02 PWM frequency OUT01 | rw USINT 100 20...250 OUT01 PWM frequen- | cy [Hz] |
| 0x03 PWM frequency OUT02 | rw USINT 100 20...250 OUT02 PWM frequen- | cy [Hz] |
| 0x04 PWM frequency OUT03 | rw USINT 100 20...250 OUT03 PWM frequen- | cy [Hz] |
| 0x5 PWM frequency OUT04 | rw USINT 100 20...250 OUT04 PWM frequen- | cy [Hz] |
| 0x6 PWM frequency OUT05 | rw USINT 100 20...250 OUT05 PWM frequen- | cy [Hz] |
| 0x7 PWM frequency OUT06 | rw USINT 100 20...250 OUT06 PWM frequen- | cy [Hz] |
| 0x8 PWM frequency OUT07 | rw USINT 100 20...250 OUT07 PWM frequen- | cy [Hz] |
| Index S-index Design Data type Default Details | |
| 0x2002 0x00 Current value ro USINT 8 Largest sub-index supported | |
| 0x01 Current value OUT00 | ro UINT 0 20...4000 OUT00 output current | [mA] |
| 0x02 Current value OUT01 | ro UINT 0 20...4000 OUT01 output current | [mA] |
| 0x03 Current value OUT02 | ro UINT 0 20...4000 OUT02 output current | [mA] |
| 0x04 Current value OUT03 | ro UINT 0 20...4000 OUT03 output current | [mA] |
| 0x05 Current value OUT04 | ro UINT 0 20...2500 OUT04 output current | [mA] |
| 0x06 Current value OUT05 | ro UINT 0 20...2500 OUT05 output current | [mA] |
| 0x07 Current value OUT06 | ro UINT 0 20...2500 OUT06 output current | [mA] |
| 0x08 Current value OUT07 | ro UINT 0 20...2500 OUT07 output current | [mA] |
| 0x00 P-value ro USINT 8 Largest sub-index supported | |
| 0x01 P-value OUT00 | rw USINT 30 0..255 OUT00 P-value for | current control |
| 0x02 P-value OUT01 | rw USINT 30 0..255 OUT01 P-value for | current control |
| 0x03 P-value OUT02 | rw USINT 30 0..255 OUT02 P-value for | current control |
| 0x04 P-value OUT03 | rw USINT 30 0..255 OUT03 P-value for | current control |
| 0x05 P-value OUT04 | rw USINT 30 0..255 OUT04 P-value for | current control |
| 0x06 P-value OUT05 | rw USINT 30 0..255 OUT05 P-value for | current control |
| 0x07 P-value OUT06 | rw USINT 30 0..255 OUT06 P-value for | current control |
| 0x08 P-value OUT07 | rw USINT 30 0..255 OUT07 P-value for | current control |
| Index S-index Design Data type | Default Details | |
| 0x2007 | 0x00 PWM dither value | ro USINT 8 Largest sub-index supported |
| 0x01 PWM dither value OUT00 | rw USINT 0 0...1 000 OUT00 PWM dither | value [%0] |
| 0x02 PWM dither value OUT01 | rw USINT 0 0...1 000 OUT01 PWM dither | value [%0] |
| 0x03 PWM dither value OUT02 | rw USINT 0 0...1 000 OUT02 PWM dither | value [%0] |
| 0x04 PWM dither value OUT03 | rw USINT 0 0...1 000 OUT03 PWM dither | value [%0] |
| 0x05 PWM dither value OUT04 | rw USINT 0 0...1 000 OUT04 PWM dither | value [%0] |
| 0x06 PWM dither value OUT05 | rw USINT 0 0...1 000 OUT05 PWM dither | value [%0] |
| 0x07 PWM dither value OUT06 | rw USINT 0 0...1 000 OUT06 PWM dither | value [%0] |
| 0x08 PWM dither value OUT07 | rw USINT 0 0...1 000 OUT07 PWM dither | value [%0] |
| 0x2012 | 0x00 Period input ro USINT 4 Largest sub-index supported |
| 0x01 Period durati-on IN00 | ro USDINT 0 IN00 period duration [μs] |
| 0x02 Period durati-on IN01 | ro USDINT 0 IN01 period duration [μs] |
| 0x03 Period durati-on IN04 | ro USDINT 0 IN04 period duration [μs] |
| 0x04 Period durati-on IN05 | ro USDINT 0 IN05 period duration [μs] |
| 0x2013 | 0x00 Period input number of periods for average | ro USINT 4 Largest sub-index supported |
| 0x01 Number of periods IN00 | rw USINT 4 1...255 IN00 number of | periods |
| 0x02 Number of periods IN01 | rw USINT 4 1...255 IN01 number of | periods |
| 0x03 Number of periods IN02 | rw USINT 4 1...255 IN02 number of | periods |
| 0x04 Number of periods IN03 | rw USINT 4 1...255 IN03 number of | periods |
| Index Sidx Design Data type Default Details | | |
| 0x1001 Error register ro USINT 0 Error Number of entries | register to USINT 0 Error | register bit coded to profile | 301 permissible values: 0b0000 0000 = no error 0b0000 0001 = generic error 0b0001 0000 = communication error 0b1000 0000 = manufacturer specific |
| 0x1003 x00 Predefined error field Number of entries | rw UINT 0 An error list with 4 entries is supported. |
| 0x01 Error history ro UINT | 0 Error occurred; coded according to EMCY list The last error is indicated in the sub-index 1 |
| 0x02 Error history ro UINT | 0 Error occurred; coded according to EMCY list |
| 0x03 Error history ro UINT | 0 Error occurred; coded according to EMCY list |
| 0x04 Error history ro UINT | 0 Error occurred; coded according to EMCY list |
| 0x05 Error history ro UINT | 0 Error occurred; coded according to EMCY list |
| 0x2020 x00 Input - short to supply voltage | ro USINT 2 Largest sub-index supported |
| 0x01 Short to supply voltage IN00... IN07 | ro USINT 0 0 = normal | 1 = short circuit | channels (bit coded) 0b---- ---X = IN00 0b---- -X- = IN01 0b---- -X-- = IN02 0b---- X--- = IN03 0b---- X---- = IN04 0b--X---- = IN05 0b-X---- = IN06 0bx---- = IN07 |
| 0x02 Short to supply voltage IN08, IN10, IN12, IN14 | ro USINT 0 0 = normal | 1 = short circuit | channels (bit coded) 0b---- ---X = IN08 0b---- -X- = IN10 0b---- -X-- = IN12 0b---- X---- = IN14 |