Nailit - Manicure and pedicure set TensCare - Free user manual and instructions
Find the device manual for free Nailit TensCare in PDF.
| Product type | Set manicure and pedicure with blue light and laser |
| Brand | TensCare |
| Model | Nailit |
| Dimensions | 69.5 x 40.5 x 35.5 mm |
| Weight | 50 g |
| Power supply | Rechargeable Li-ion battery 3.7 V, 900 mAh, charging via USB-DC (5 V, 450 mA) |
| Battery life | Approximately 22 hours (185 sessions of 7 minutes) |
| Charging time | 2.5 to 3 hours |
| Laser type | Class 1M (IEC 60825-1) |
| Laser wavelength | 905 nm |
| Blue light wavelength | 470 nm |
| Laser power | 25 W (maximum pulse intensity 22 W) |
| Session duration | 7 minutes automatic |
| Recommended usage frequency | Once per day per nail |
| Time to visible improvement | 3 to 6 months of daily use |
| Cleaning | Medical alcohol on a cloth for the inner rubber padding |
| Protection rating | Do not immerse. Type B shock protection |
| Photobiological safety | Exempt group according to EN62471, no photobiological hazard |
| Safety classification | Internal power source, continuous operation, Class II equipment |
| Operating temperature | 5°C to 40°C |
| Operating humidity | 15 to 90% RH non-condensing |
| Spare parts and repairability | No user-serviceable parts. Battery replaceable only by a qualified technician. |
| Warranty | 1 year against manufacturing defects (excluding charging cable) |
Frequently Asked Questions - Nailit TensCare
User questions about Nailit TensCare
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Manicure and pedicure set in PDF format for free! Find your manual Nailit - TensCare and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Nailit by TensCare.
USER MANUAL Nailit TensCare
Nail cleaning device
User Manual
Manual del usuario
Mode d'emploi
Manuale d'uso
Benutzerhandbuch


Safety


The device should be used in strict compliance with the safety and operating instructions provided in this manual.
Do NOT use the device close to the womb during pregnancy.
Avoid direct eye contact from the laser radiation/blue light/infrared radiation to protect against the danger of excessive exposure to visible and infrared light.
Caution: Keep the device away from children. Children under the age of 18 years should only use the device under adult supervision.
Do NOT immerse your device in water or place it close to excessive heat such as a fireplace or radiant heater or sources of high humidity such as a nebulizer or kettle as this may cause it to cease to operate correctly.
Do NOT use this device if the clear plastic filter is broken or removed.
There are no user serviceable parts. No modification of this equipment is allowed.
Do NOT use the device for the following persons:
• Suffering from sunburn.
• Under medical care for diseases that involve photosensitivity.
• Receiving photosensitising medications.
If you experience any unexpected side effects such as itching, that occurs within the first 48 hours of using the device, medical advice should be sought prior to further exposure.
The device can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance and should not be left unsupervised.
Operating Instructions


The device should be applied to each nail you would like to clean. Nailit can be used with both hands and feet.
- Before using Nailit, be sure to thoroughly clean all nails which are to be used with the device.
- Clamp the Nailit device onto the nail. Ensure the nail is facing the transparent, round window and therefore exposed to the blue light.
- Press and hold the ON/OFF button for 3 seconds to switch on the device.
- The ON/OFF button will flash green, indicating the session is underway. The nail is now exposed to the laser and blue light. The green light will continue to flash for the duration of the session (7 minutes).
- At the end of the session, the green light will stop flashing and the device will switch off automatically.
Frequency of Use

Each nail should be used with the device once a day. A visible improvement of the appearance of the nails is estimated to take 3-6 months when used daily. However, the effectiveness may vary between individuals. This device can be used at home.
Charging
Nailit is powered by a rechargeable Li-ion battery. A USB-DC charging cable is included in the kit.
The battery should last 185 sessions. The battery has an estimated charging time of 2.5 – 3 hours from empty to fully charged. When the battery is running low, the LED indicator will flash red.
To charge the battery: Simply plug the charging cable in the device and charge with a standard USB charger. When charging the LED will flash green.
Warning: The battery in this device can only be replaced by qualified technicians.
The device cannot be operated while charging. When the battery is fully charged, the indicator will light green continuously.
Warning: Use only the charging cable supplied. Use of other cables could be hazardous and will negate the warranty.
Cleaning
After every use, we recommend that you clean the inner rubber padding. Apply medical alcohol to a cloth and wipe clean. Do not share the device with other people without cleaning the rubber padding.
Cleaning and user maintenance must not be carried out by children without supervision.
Troubleshooting


If your Nailit is not working properly, please check the following:
| Problem Possible causes Solution | ||
| Battery light is red | Rechargeable battery has run out of power | Connect device to charger until LED continuously lights green. The device cannot be operated while charging |
| Device does not operate | Technical fault C | Contact dealer/manufacturer |
If problems persist, or to report unexpected operation or events, call TensCare or your local dealer for advice.
Frequently Asked Questions
1. When will nail appearance improve?
Estimated time for visible improvement is 3 to 6 months. Effectiveness may vary between individuals.
2. Can the laser burn me?
No. Use of a Class 1M laser device should be pain-free with no side-effects or trauma.
Technical Information


| Laser type 1M (IEC 60825-1) | |
| Laser wavelength 905nm | |
| Blue light wavelength 470nm | |
| Laser power 25W | |
| Maximum pulse intensity 22W | |
| Output plug USB to DC (DC Φ2.5xΦ0.7x10 mm) | |
| Battery TW 902244 Li-ion battery 3.7V | |
| Battery life 22 hours | |
| Weight 50g | |
| Dimensions 69.5 x 40.5 x 35.5 mm | |
| Safety Classification Internal power source. Designed for continuous use. | |
| Environmental Specifications: | |
| Operating: Temperature range: 5°C-40°CHumidity: 15-90% RH non-condensing | |
| Storage: Atmospheric pressure: 700hPa-1060hPATemperature range: -10°C-60°CHumidity: 15% to 75% RHnon-condensingAtmospheric pressure: 700hPa-1060hPa | |
| Battery Specification | |
| Battery type Lithium ion battery (Model: TW 902244) | |
| Battery capacity 900mAh | |
| StoragetemperatureStorage humidity | -10°C-60°C (≤1 month)-10°C-45°C (≤3 months)-10°C-28°C (≤1 year)45% - 75% RH |
| ChargingSpecification | Current: max 450mAVoltage: 5VPower: 2.5W |
Warranty Information

The product is warranted to be free from manufacturing defects for 1 year from the date of purchase.
This warranty refers to the unit only and does not cover the charging cable.
This warranty is void if the product is modified or altered, is subject to misuse or abuse; damaged in transit; lack of responsible care; is dropped; if the unit has been immersed in water; if damage occurs by reason of failure to follow the user manual; or if product repairs are carried out without authority from TensCare Ltd.
Our goods come with guarantees that cannot be excluded under the UK consumer Law. You are entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality.
Before you send your unit for service please be sure to read the user manual and follow all the instructions.
Should repair be needed within the warranty period, please return the device with the following details:
Name:
- Address:
- Telephone:
E-mail:
• Date of Purchase:
• Proof of Purchase:
Returns should be sent to the following address:
TensCare Ltd
PainAway House,
9 Blenheim Road,
Longmead Business Park,
Epsom, Surrey
KT19 9BE, UK
For more information, please call +44 (0) 1372 723 434.

Complies with:
EN55015:2013 +A1:2015, EN IEC 61000-3-2:2019, EN61000-3-3:2013 +A1:2019, EN61547:2009, IEC 60825-1 :2014 (Third addition)
Photobiological safety
Exempt Group under EN62471:2006, does not pose any photobiological hazard.

Refer to Instructions for Use

Storage Temperature

Shock protection Type B

WEEE - Recycle responsibly

product

Class II equipment Class 1M

Keep away from sunlight
Seguridad


Longmead Business Park,
Epsom, Surrey
KT19 9BE, UK
Longmead Business Park,
Epsom, Surrey
KT19 9BE, UK
Longmead Business Park,
Epsom, Surrey
KT19 9BE, UK
Longmead Business Park,
Epsom, Surrey
KT19 9BE, UK
9 Blenheim Road, Epsom,
Surrey, KT19 9BE, UK
+44(0) 1372 723434
www.tenscare.co.uk
info@tenscare.co.uk

TensCare Europe BV
I-NL-ML [UK, ES, FR, IT, DE] Rev 2.2 07/21