Nailit - Manicure and pedicure set TensCare - Free user manual and instructions
Find the device manual for free Nailit TensCare in PDF.
Download the instructions for your Manicure and pedicure set in PDF format for free! Find your manual Nailit - TensCare and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Nailit by TensCare.
USER MANUAL Nailit TensCare
Safety The device should be used in strict compliance with the safety and operating instructions provided in this manual. Do NOT use the device close to the womb during pregnancy. Avoid direct eye contact from the laser radiation/blue light/ infrared radiation to protect against the danger of excessive exposure to visible and infrared light. Caution: Keep the device away from children. Children under the age of 18 years should only use the device under adult supervision. Do NOT immerse your device in water or place it close to excessive heat such as a replace or radiant heater or sources of high humidity such as a nebulizer or kettle as this may cause it to cease to operate correctly. Do NOT use this device if the clear plastic lter is broken or removed. There are no user serviceable parts. No modication of this equipment is allowed.
Do NOT use the device for the following persons: Suffering from sunburn. Under medical care for diseases that involve photosensitivity. Receiving photosensitising medications. If you experience any unexpected side effects such as itching, that occurs within the rst 48 hours of using the device, medical advice should be sought prior to further exposure. The device can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance and should not be left unsupervised.
Operating Instructions The device should be applied to each nail you would like to clean. Nailit can be used with both hands and feet. Before using Nailit, be sure to thoroughly clean all nails which are to be used with the device. Clamp the Nailit device onto the nail. Ensure the nail is facing the transparent, round window and therefore exposed to the blue light. Press and hold the ON/OFF button for 3 seconds to switch on the device. The ON/OFF button will ash green, indicating the session is underway. The nail is now exposed to the laser and blue light. The green light will continue to ash for the duration of the session (7 minutes). At the end of the session, the green light will stop ashing and the device will switch off automatically.
Frequency of Use Each nail should be used with the device once a day. A visible improvement of the appearance of the nails is estimated to take 3-6 months when used daily. However, the effectiveness may vary between individuals. This device can be used at home. Charging Nailit is powered by a rechargeable Li-ion battery. A USB-DC charging cable is included in the kit. The battery should last 185 sessions. The battery has an estimated charging time of 2.5 – 3 hours from empty to fully charged. When the battery is running low, the LED indicator will ash red. To charge the battery: Simply plug the charging cable in the device and charge with a standard USB charger. When charging the LED will ash green.
Warning: The battery in this device can only be replaced by
qualied technicians.6 The device cannot be operated while charging. When the battery is fully charged, the indicator will light green continuously.
Warning: Use only the charging cable supplied. Use of other
cables could be hazardous and will negate the warranty. Cleaning After every use, we recommend that you clean the inner rubber padding. Apply medical alcohol to a cloth and wipe clean. Do not share the device with other people without cleaning the rubber padding. Cleaning and user maintenance must not be carried out by children without supervision.7 Troubleshooting If your Nailit is not working properly, please check the following: Problem Possible causes Solution Battery light is red Rechargeable battery has run out of power Connect device to charger until LED continuously lights green. The device cannot be operated while charging Device does not operate Technical fault Contact dealer/manufacturer If problems persist, or to report unexpected operation or events, call TensCare or your local dealer for advice. Frequently Asked Questions When will nail appearance improve? Estimated time for visible improvement is 3 to 6 months. Effectiveness may vary between individuals. Can the laser burn me? No. Use of a Class 1M laser device should be pain-free with no side-effects or trauma.
Technical Information Laser type 1M (IEC 60825-1) Laser wavelength 905nm Blue light wavelength 470nm Laser power 25W Maximum pulse intensity 22W Output plug USB to DC (DC Φ2.5xΦ0.7x10 mm) Battery TW 902244 Li-ion battery 3.7V Battery life 22 hours Weight 50g Dimensions 69.5 x 40.5 x 35.5 mm Safety Classication Internal power source. Designed for continuous use.9 Technical Information Environmental Specications: Operating: Temperature range: 5°C-40°C Humidity: 15-90% RH non-condensing Storage: Atmospheric pressure: 700hPa-1060hPa Temperature range: -10°C-60°C Humidity: 15% to 75% RH non-condensing Atmospheric pressure: 700hPa-1060hPa Battery Specication Battery type Lithium ion battery (Model: TW 902244) Battery capacity 900mAH Storage temperature Storage humidity -10°C-60°C (≤ 1 month) -10°C-45°C (≤ 3 months) -10°C-28°C (≤ 1 year) 45% - 75% RH Charging Specication Current: max 450mA Voltage: 5V Power: 2.5W10 Warranty Information The product is warranted to be free from manufacturing defects for 1 year from the date of purchase. This warranty refers to the unit only and does not cover the charging cable. This warranty is void if the product is modied or altered, is subject to misuse or abuse; damaged in transit; lack of responsible care; is dropped; if the unit has been immersed in water; if damage occurs by reason of failure to follow the user manual; or if product repairs are carried out without authority from TensCare Ltd. Our goods come with guarantees that cannot be excluded under the UK consumer Law. You are entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality. Before you send your unit for service please be sure to read the user manual and follow all the instructions.11 Warranty Information Should repair be needed within the warranty period, please return the device with the following details: Name: Address: Telephone: E-mail: Date of Purchase: Proof of Purchase: Returns should be sent to the following address: TensCare Ltd PainAway House, 9 Blenheim Road, Longmead Business Park, Epsom, Surrey KT19 9BE, UK For more information, please call +44 (0) 1372 723 434.
ManualGo.com