Engine type 4-stroke, air-cooled
Displacement 196 cm³
Engine power 3.8 kW (5.2 PS)
Maximum flow rate 48,000 l/h
Maximum pressure 3.0 bar
Maximum suction height 6 m
Maximum discharge height 30 m
Connection diameter (suction/discharge) 3" (73.5 mm)
Fuel tank capacity 3.6 L
Recommended fuel Unleaded gasoline
Engine oil 15W-40, 0.8 L
Maximum water temperature +40°C
Sound level 103 dB (LWA)
Weight 26.8 kg
Dimensions (L × W × H) 550 × 430 × 490 mm
Warranty 12 months (professional use), 24 months (private)
Safety function Automatic shutdown in case of oil shortage (Auto Stop)
Priming Automatic (initial filling of the pump)
Usage Clean or slightly dirty water
Included accessories 2 hose connectors, 2 gaskets, 3 clamps, spark plug wrench, foot valve
Air filter maintenance Every 3 months or 50 operating hours
Spark plug maintenance Every 6 months or 100 operating hours

Frequently Asked Questions - GMP 200 4T Güde

How to start the GMP 200 4T pump?
Open the fuel valve, set the switch to ON, the choke lever to START, the throttle to FULL, then pull the starter cord firmly. Once started, slowly move the choke to the run position.
What to do if the pump does not pump or pumps little?
Check that the pump is filled with water, the suction line is airtight, the filter is not clogged, and the suction height does not exceed 6 m. Refer to the troubleshooting table for more details.
What type of engine oil should be used?
Use 15W-40 engine oil in a quantity of 0.8 liter. Check the level before each use and change it at least once a year.
How to maintain the air filter?
Clean the air filter every 3 months or after 50 hours of operation. Use a non-flammable solvent, never gasoline. Let it dry before reassembling. Replace it every 6 months or 300 hours.
What to do if the oil shortage sensor is activated?
The engine stops automatically. Check the oil level and add 15W-40 oil up to the MAX mark. Then restart normally.
Can salt water be pumped with this pump?
No, the pump is not suitable for pumping salt water, fecal matter, flammable liquids, or other hazardous liquids. It is designed for clean or slightly dirty water.
How to store the pump in winter?
Drain all water from the pump to prevent freezing. Let it dry completely. Drain the fuel tank and carburetor. Store in a dry, frost-free place.
What accessories are included with the pump?
The pump comes with 2 hose connectors, 2 hose gaskets, 3 clamps, a spark plug wrench, and a foot valve (suction strainer).
How to prime the system before first use?
Fill the pump with water through the fill port. Open the taps in the pressure line to let air escape. Start the engine at full throttle until water flows evenly.
What is the warranty period of the GMP 200 4T?
The warranty is 12 months for industrial use and 24 months for the end consumer. It covers material and manufacturing defects, provided the operating instructions are followed.

User questions about GMP 200 4T Güde

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Water pump in PDF format for free! Find your manual GMP 200 4T - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GMP 200 4T by Güde.

USER MANUAL GMP 200 4T Güde

natural_image Icon of an open book inside a black circle (no text or symbols)

Deutsch D 3

Translation of original operating instructions MOTOR PUMP

Français F 16

natural_image Technical line drawing of a portable pump or generator unit (no text or symbols visible)

CE

Labeled diagram of a portable pump with numbered components and safety warning symbols

Exploded view diagram of a mechanical component with numbered parts for identification

Güde GMP 200 4T - 3

Einleitung

We reserve right for technical changes for further improvement and development of the product.

This is the original operation manual.

Identification:

Warnings/prohibitions:

H2O ←→
Fill the pump with water.Other persons must step aside at a sufficient distance.
MAZ MIN → AUTO STOP →HIGH LOW
Oil low level sensor (see user guide)Throttle lever adjustment
![]('img_url')![]('img_url')
General warning instructionsUse outdoors only, toxic flue gases

STOP Warning instructions for refuelling Check for oil level before starting.

Product safety:

CE
The product complies with relevant EU standards

Environment protection:

Güde GMP 200 4T - Identification: - 2Güde GMP 200 4T - Identification: - 3
Dispose waste not to harm your environment.Packaging material from cardboard can be recycled in a collection point.
Güde GMP 200 4T - Identification: - 4
Defective and/or disposed electric or electronic devices must be delivered to relevant collection points.

Technical data:

Güde GMP 200 4T - Identification: - 5Güde GMP 200 4T - Identification: - 6
Motor power Volume of cylinders
Güde GMP 200 4T - Identification: - 7Güde GMP 200 4T - Identification: - 8
Delivered volume Suction lift
Güde GMP 200 4T - Identification: - 9Güde GMP 200 4T - Identification: - 10
Total head Weight
Güde GMP 200 4T - Identification: - 11
Noise level

Device description (figure A)

  1. Tank
  2. Tank lid
  3. Exhaust
  4. Fram e
  5. Suction neck
  6. Rubber foot
  7. Oil level indicator
  8. Oil drainingscrew
  9. Oil low level sensor
  10. ON/OFF switch
  11. Bowden starter
  12. Throttle lever
  13. Filling neck
  14. Output neck
  15. Saturator
  16. Air filter
  17. Carburettor
  18. Draining screw
  19. Gasoline cock

Accessories (Fig. B)

  1. 2 x hose connector
  2. 2 x hose seal
  3. 3 x hose clamps
  4. 1 x wrench for spark plugs
  5. 1 x foot valve (strainer)

Warranty

A warranty period of 12 months applies to commercial use and 24 months apply to private use and commences on the day of purchase of the device.

Warranty applies exclusively to failures due to defective material or workmanship. An original sale slip with indication of date of sale must be presented in case of claiming for the warranty rights.

Warranty does not cover unprofessional use such as device overload, violent use, damage caused by third party or foreign materials, failure to comply with operations and assembly manual, and normal wear and tear.

Technical information GMP 200

Engine type (air cooled)four stroke engine
Volume of cylinders196 ccm
Motor power3.8 kW – 5.2 PS
Max delivered volume48,000 l/h
Max water pressure in piping3.0 bar
Max suction lift6 m
Max total head30 m
∅ pressure/suction connectorAbout 73.5 mm
Tank volume3.6l
Pressure connector3" outer thread
FuelUnleaded gasoline
Engine oil15W-40/0.8 L
Max water temperature+ 40 °C
Noise levelLWA 103 dB
Weight26,8 kg
Dimensions length x width x height550x430x490 mm

General safety instructions

Please read through this user guide and make sure you know all controls and proper use of this product. We shall not be responsible for damage caused by non-adherence of the instructions and procedures in this user guide. Damage due to non-adherence of the instructions and procedures are excluded from warranty. Keep the user guide well and pass it to a new owner of the machine.

Children and person not informed about content of this user guide must not operate the machine. Supervise children to prevent playing with the machine. Applicable directives in certain countries restrict minimum age of the potential user and these directives must be respected.

Physically and mentally handicapped persons or persons with sensorial limitations must not operate the machine albeit under supervision of a security engineer or based on instructions for operation received from a responsible person.

Please obey the special safety instructions listed in the chapters of this user guide.

Cautions and instructions with the following symbol must be followed with special care:

Güde GMP 200 4T - General safety instructions - 1

Failure to comply with this instruction may

result in hazard to humans and/or material damage!

Check the machine for transport damage. In case of damage, inform your sales representative immediately.

The pump is not suitable for pumping of salt water, faecal solids, flammable, corrosive, explosive and other dangerous liquids. Furthermore, the pump is not suitable for pumping of potable water and other foods.

The transported liquid must not drop below or exceed minimum or maximum liquid temperature specified in the technical data.

Emergency procedures

For reasons of potential injury, a first aid box according to DIN 13164 must be available on workplace. Replenish immediately material used from the first aid box.

If you require assistance, please give the following details:

Place of accident

Type of accident

Number of injured persons Type of injury

Administer first aid according to injury and call for qualified medical assistance.

Protect injured person against other injuries and keep him/her in rest.

Application according to intended use

Gasoline engine pump for pumping of clean or moderately contaminated water. Any other use contradicts to the intended use. Manufacturer is not responsible for subsequent damage and injuries. Please note the appliance is intended for domestic use only.

Area of applicability

The machine is suitable for pumping of clean or moderately contaminated water.

Thanks to high performance, the model can be used industrially and in agriculture.

Standard areas of applicability of the gasoline engine pump:

■ water delivery on construction sites
- irrigation of gardens, flowerbeds, fields and raining
- pumping of water from wells, tanks, flows, streams etc.
- draining and filling of fish ponds, pits etc.

Disposal

Disposal instructions are illustrated in the form of pictograms on the device or packaging. Description of the pictograms is given in "Identification" chapter.

Disposal of transport packaging

Packaging protects the device against damage during transport. Packaging materials are usually selected according to their effect on environment and disposal methods and can therefore be recycled.

Returning of the packaging back to circulation saves resources and costs for packaging disposal.

Parts of the packaging (e.g. foil, styropor) may be dangerous for children. Risk of suffocation!

Keep these parts of the packaging out of reach of children and dispose as soon as possible.

Operator requirements

The operators must thoroughly read operation manual before use.

Qualification

Except for thorough training by an expert for use of the device, no special qualification is required.

Minimum age

The machine may be used by persons over 18 years and trained in handling and function of the machine. Supervision is required for persons from 16 to 18 years.

An exception is use by younger person if the use takes place under supervision of an adult trainer in the course of education.

Training

Use of the device requires corresponding guidance by an expert or operation manual only. No special training is required.

Transport and storing

  • For long-term storing, the machine must be thoroughly cleaned and no unauthorized persons may have access to the machine.
  • Secure the machine against turning over before each transport.

Assembly/first commissioning

The gasoline engine pump is installed in a stable cage made from steel tubes with vibration damper. These devices must not be disassembled during operation because they provide stability and reduce vibrations.

General installation instructions

Güde GMP 200 4T - General installation instructions - 1

All connection piping must be absolutely tight. Leaking piping may influence operation of the pump negatively and cause substantial damage.

Güde GMP 200 4T - General installation instructions - 2

During installation, the machine must not be

running.

All connection piping must be absolutely tight because leaking piping may influence operation of the pump negatively and cause substantial damage. Therefore, make screw connections between the pump and the piping and seal with Teflon tape. Use of the sealing material such as Teflon tape will ensure airtight assembly.

Do not overtighten the screw joints to avoid damage. During installation of the connection piping, make sure the pump is free of any forces, weight, vibration, and stress.

Installation of the suction piping

Güde GMP 200 4T - Installation of the suction piping - 1

A filter must be installed at the input of the suction to remove coarse impurities from water with potential or clogging or damaging the pump.

The suction piping will transport the liquid to be pumped up to the pump. Use the suction piping of diameter identical to the pump suction connector. For pumping lift with the difference between the pump and the pumped liquid level of more than 4 metres, using of +1/4 diameter is recommended.

A filter must be installed at the input of the suction piping to remove coarse impurities from water with potential of either clogging or damaging the pump.

In addition, it is highly recommended to install the return valve to prevent pressure leak after turning the pump off and protecting the machine against damage due to pressure surges. The return valve can be connected directly on the pump suction connector or the suction piping input. Installation on the suction piping input is favourable. The suction piping can be easily deaerated by filling with water.

The suction piping input must always be located at least 0.30 m under pumped liquid level to avoid air inlet. In addition to this, pay attention to sufficient distance of the suction piping from soil and streams, rivers, fishponds banks to avoid suction of stones, plants etc.

Installation of the force piping

The force piping transports the liquid to be pumped from the pump to the consumption point. To avoid losses from flow, using of the force piping of at least identical diameter as the pump connector is recommended.

Fixed installation

For fixed installation, attach the gasoline engine pump to a suitable stable supporting surface. To reduce vibrations, it is recommended to insert an anti-vibration material, e.g. rubber layer, between the pump and the supporting surface.

Commissioning

Installation and visual control

Güde GMP 200 4T - Installation and visual control - 1

Flue gases of the gasoline engine pump contain less toxic carbon monoxide that may result in serious issues and death under extreme conditions. To protect s and animals, the machine must not be used in poorly red places and not in closed spaces. Generally, avoid ing of the flue gases.

Güde GMP 200 4T - Installation and visual control - 2

Check the gasoline engine pump with respect to safety use. Do not use the machine if damaged.

Güde GMP 200 4T - Installation and visual control - 3

The gasoline engine pump may only be used in areas at risk of floods.

For each starting of the machine, it is necessary to make sure the pump is installed safely and in a stable position. Always pay attention to a flat surface under the pump, otherwise the oil low level sw itch may be activated and starting is not enabled. The gasoline engine pump may only be used in areas without risk of floods.

Select the place of the pump installation so that no environmental damage is caused by leaked fuel or engine oil. If used in fish ponds, pits, construction pits, rivulets, streams and similar places, the pump must be secured against fall.

Check the gasoline engine pump visually before use of the pump. Pay attention to correct tightness of the bolts and perfect condition of all connectors. Do not use the machine if damaged.

Fuel and fuelling/engine oil

Güde GMP 200 4T - Fuel and fuelling/engine oil - 1

The gasoline engine pump is powered by gasoline. Use I specified in the technical data applicable to your t.

Güde GMP 200 4T - Fuel and fuelling/engine oil - 2

Do not smoke and work with open flame when ing. Do not breathe vapours.

Güde GMP 200 4T - Fuel and fuelling/engine oil - 3

Gasoline and engine oil are toxic substances. Do not w gasoline or engine oil and do not breathe vapours. Any direct contact of gasoline and engine oil with skin, and clothes.

Do not refuel if the engine is running. Turn the pump off and let it cool for at least five minutes before refuelling. During refuelling, the machine must be placed on a flat surface in vertical position to avoid fuel leak. Refuel in well-ventilated area only. All leaked gasoline must be first cleaned and then start up the engine.

Do not smoke and work with open flame when refuelling. Do not breathe vapours.

Güde GMP 200 4T - Fuel and fuelling/engine oil - 4

Check oil level before use (see

Replacement/check of oil)

Filling the pump with water or deaerating of the system

Pour water in the filling hole of the pump. Check for water leaks. Close the filling hole again to be airtight. It is recommended - but not absolutely necessary - to fill the suction piping with water as well.

The gasoline engine pump is self-suctioning device. It means that for starting, only the pump and not the suction piping must be filled. In either way, the pump will need some more minutes to draw the pumped liquid. Additional filling of the suction piping will significantly facilitate and fasten the first suction. If the suction piping is not filled with the liquid, it will be perhaps necessary to prime the pump several times with water. It depends on length and diameter of the suction piping.

Open potential closures in the force piping (e.g. water cock) to release air during suction.

Starting of the engine

Open the gasoline cock to turn the engine on (Fig. A/19). Set the ignition breaker (Fig. A/10) to ON position, set the saturator lever (Fig. A/15) in Start position and the power controller (Fig. A/12) to Full throttle position. Then, pull with the starting rope (Fig. A/11) several times until the engine starts. Then, slowly set the saturator lever (Fig. A/15) in the operation position. As soon as the engine starts, suction commences. Now, leave the power controller (Fig. A/12) in the Full throttle position. If the liquid is drawn equally or without any air, the suction is interrupted and the system deaerated. Now, set the power controller (Fig. A/12) according to individual requirements.

Operation

Güde GMP 200 4T - Operation - 1

The gasoline engine pump must not be used with very point closed.

Güde GMP 200 4T - Operation - 2

The pump must not be used w ithout w ater for longer of time. Dry operation, i.e. w ithout pumping of w ater, sult in substantial damage of the machine.

Güde GMP 200 4T - Operation - 3

The gasoline engine pump and the piping system be protected against freeze and weather conditions.

Güde GMP 200 4T - Operation - 4

Flammable substances and things, easily unable or explosive substances must be out of reach pump during operation. Do not put anything on the

Güde GMP 200 4T - Operation - 5

If the engine is in operation, do not refuel or pour oil in the pump off before refuelling.

Güde GMP 200 4T - Operation - 6

During operation, some parts of the engine pump - e.g. t or exhaust cover - are very hot. To avoid burning , touch the machine during operation and after turning it d cooling dow n on the designed points only - e.g. on es and handles.

During first 20 hours of operation, the brand new engine must not be fully loaded. Operation at 2/3 of possible output performance is recommended. Full throttle operation is now permissible for short term only up to 10 minutes - e.g. for starting due to suction operation.

Turning the engine off

Set the power controller (Fig. A/12) to Idle Throttle position and set the ignition breaker (Fig. A/10) to OFF position. The pump input is fitted with a valve that prevents leaking of water from the pump after it is turned off. Stopping of the back flow will result in shorter time for re-suction during the next start. Therefore, the pump must not be primed again during restart.

Decommissioning

Güde GMP 200 4T - Decommissioning - 1

Transport of the pump with the fuel tank filled is not ed.

Discharge water in the pump from the relevant discharge hole after use. Let the pump dry well to avoid damage due to corrosion. Water entrapped in the pump may cause damage if frozen.

If the device is transported, all fuel must be discharged. Transport of the pump with the fuel tank filled is not approved.

Care and maintenance

Güde GMP 200 4T - Care and maintenance - 1

If possible, turn the engine off, remove the spark plug and let the engine cool down before maintenance. If the must be on during maintenance, provide sufficient action because the exhaust fumes are toxic.

Regular maintenance and diligent care reduce the risk of potential operation failures and contribute to improved lifecycle of your machine. The engines consist of the up-to-date technology and many rotary components exposed to substantial mechanic, thermal as well as chemical effect of environment and the combustion process. Use of correct, high quality and clean operation liquids - fuel and engine oil - is prevention against damage to the engine and operation failures.

Abrasive substances in the delivered liquid, such as sand, increase wear and tear and reduce total performance. Installation of a pre-filter is highly recommended for pumping of liquids with abrasive substances. The recommended accessories filter sand and other similar substances from the liquid effectively and reduce wear and tear and improve lifecycle of the pump.

Oil check and replacement

Güde GMP 200 4T - Oil check and replacement - 1

Check for oil level before starting.

Oil must be replaced at least annually. Engine oil deteriorates during this period despite the fact the engine is not almost used. For oil replacement, discharge old oil and pour new oil in the filling hole in the oil tank (for type and quantity of oil - see Technical data). Excessive amount of oil has negative effect as well- (see quantity of oil - Technical data).

Diligent care includes oil level check before use. Use prescribed oil dipstick for inspection. During the oil level check, the machine must stand flat, turned off and cooled down. Make sure oil level does not exceed maximum quantity and fall under minimum quantity required as indicated on the dipstick. (For type and quantity of oil - see Technical data).

Please, observe local requirements applicable to disposal of used oil.

Güde GMP 200 4T - Oil check and replacement - 2

If the engine operates, do not pour engine oil in it.

Before filling of the engine oil, turn the pump off and let it cool down for at least 5 minutes. During pouring of the engine oil, the machine must be placed on a flat surface in vertical position to avoid engine oil leak. All leaked engine oil must be first cleaned and then start up the engine.

Güde GMP 200 4T - Oil check and replacement - 3

Do not smoke and work with open flame when

pouring the engine oil. Do not breathe vapours.

Automatic Auto Stop activation (safety feature for low oil level) for low oil level.

This technology automatically turns the engine off when the oil level is lower than minimum required. The engine can be restarted after sufficient quantity of engine oil is replenished. When replenishing engine oil, adhere to all instructions related to the engine oil and engine oil check as specified in this guide.

Ignition plug

Cleaning of the ignition plug and correction of distances of the electrodes must be performed in six-month intervals or after 100 hours of operation. First, remove the ignition plug shield before maintenance of the ignition plug. Then, screw the ignition plug out using the ignition plug key. To ensure failure-free operation, the dry ignition plug without burnt residues must show distance of the electrodes 0.6 - 0.7 mm.

If necessary, clean the ignition plug. To remove the burnt residues, use a fine wire brush. Distance of the electrodes must be corrected by slight bending of the electrode. It is recommended to use a new ignition plug in case of strong accumulation or worn electrodes.

Checked, cleaned or a new ignition plug must be screwed first manually to stop. Then, tighten the ignition plug using the ignition plug key. Avoid excessive forces not to damage the ignition plug due to torque. Finally, slide the ignition plug shield back on the ignition plug.

Air filter

Güde GMP 200 4T - Air filter - 1

To clean the air filter, do not use gasoline or a

thinner with low flash point in any case due to fire and explosion danger.

If the air filter is clogged, it prevents air flow to the carburettor. To avoid operation failures of the carburettor, air filter must be regularly checked and cleaned or replaced, if necessary.

Generally, checking of the air filter as far as clogging is concerned is recommended before use. Cleaning is required in three-month interval or after 50 hours of operation. When the pump is operated in dirty or dusty environment, cleaning must be performed in ten-hour intervals. Use a new air filter in six-month interval or after 300 hours of operation.

Open air filter cabinet and remove the air filter before maintenance. Wash the air filter with an inflammable thinner, if necessary - e.g. detergent. To clean the air filter, do not use gasoline or a thinner with low flash point in any case due to fire and explosion danger. Let the air filter dry after cleaning.

Insert checked, cleaned or new air filter and close it again. Do never use the pump without the air filter to avoid increased wear and tear of the engine.

Replacement of the slide locking ring

The slide locking ring is the seal between the pump body and the engine shaft. The ring is a component with natural wear and tear.

If the slide locking ring is defective, water leaks between the engine and the pump body. Demount the pump body, manual starting device and the pump moving wheel. Then, the slide locking ring may be replaced. Finally, carefully mount the moving wheel of the pump, manual starting device and the pump body.

Removal of foreign particles from the pump

Coarser particles in the pumped liquid may block the pump body and the pump moving w heel. For this case, the pump body can be demounted in order to remove all impurities from the pump moving w heel.

Storing

If the machine is not used for longer time, all water in the pump must be drained. Let the pump dry to avoid corrosion. Drain the fuel tank and the carburettor. Cleaning and preserving of the machine before storing is recommended. Make sure the machine is stored in dry and frost-proof place.

Failures

Make sure no water gets in the machine.

Güde GMP 200 4T - Failures - 1

We shall not be liable for damage due to unprofessional attempts. Damage due to unprofessional repair attempts void any warranty claims.

All measures for removal of defects may be performed only if the engine is stopped.

The following list specifies some potential machine damages, potential reasons and tips for removal. All measures for removal of defects may be performed only if the engine is stopped. If you are unable to remedy the defect, please contact either the customer service or your sales representative. Overhaul repairs may be performed by authorized personnel only. Please note that w arranty claims shall void in case of damage due to unprofessional repair attempts and w e shall not be responsible for any consequent damage.

In case of operation failures, first check for operator error or other cause not associated with the machine defect - e.g. no fuel.

Maintenance table

DetectPossible causeRemedy
The pump does not pump or pumps too little of liquid, the engine runs.1. Too much liquid in the pump.2. Suction piping not sealing.3. Too low engine power selected.4. Suction piping input filter clogged.5. Suction piping clogged.6. Pump moving wheel blocked by impurities.7. Too high suctionlift/total head.8. Defective slide locking ring.9. Pump moving w heel not fitted correctly.10. Damaged pump moving w heel.11. Irregular engine operation.1. Pour liquid in the filling hole of the pump body.2. Tighten the suction piping and piping connectors with Teflon tape. Replace the suction piping if irreparable damage is detected.3. Increase engine power.4. Clean the filter.5. Clean the suction piping.6. Remove impurities.7. Change theinstallation so that the suction lift/total head does not exceed max imum value.8. Replace the slide locking ring.9. Place the pump moving w heel correctly.10. Replace the pump moving w heel.11. Contact the customer service.
Vibration or noisy operationToo high suction lift/total head.Foreign particle blocks the suction piping and/or the pump moving w heel.Unstable installation.Unstable machine installation.Damaged pump moving w heel.Other technical defect.Change the installation so that the suction lift/total head does not exceed max imum value.Remove foreign particle.Stabilize the installation.Ensure stable position of the machine.Replace the pump moving w heel.Contact the customer service.
The engine does not start or turns off during operation.Low fuel.No ignition spark.Clogged carburettor.Clogged air filter.Activated Auto Stop because of low engine oil level.Other technical defect.Open the gasoline cock and/or refuel.Check the ignition sw itch. Or check the ignition plugs.Clean the carburettor.Clean air filter.Replenish engine oil.Contact the customer service.

Introduction

EC-DECLARATION OF CONFORMITY

We, hereby declare the conception and construction of the below mentioned appliances correspond - at the type of construction being launched - to appropriate basic safety and hygienic requirements of EC Directives. In case of any change to the appliance not discussed with us the Declaration expires.

DECLARATION CE DE CONFORMITE

PROHLASENI O SHODE EU

97/6 8/EC_2004/26/EC

Emission No.: e11*97/68SA*2004/26*0590*00

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Güde

Model : GMP 200 4T

Category : Water pump