Captur Timer Kit (Fujifilm) - Remote control Hähnel - Free user manual and instructions
Find the device manual for free Captur Timer Kit (Fujifilm) Hähnel in PDF.
User questions about Captur Timer Kit (Fujifilm) Hähnel
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Remote control in PDF format for free! Find your manual Captur Timer Kit (Fujifilm) - Hähnel and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Captur Timer Kit (Fujifilm) by Hähnel.
USER MANUAL Captur Timer Kit (Fujifilm) Hähnel
Note:For Panasonic. Receiver end plug is grey in colour. Push in fully. Note: For Panasonic. Timer end plug is grey in colour. Push in fully. Note: For Panasonic. Receiver end plug is grey in colour. Push in fully. Note:For Panasonic. Timer end plug is grey in colour. Push in fully. Lock Start/Stop SET Manual Timer Kit Captur Module - Timer 1 Connecting your Captur - Timer Kit Wireless: Connect Receiver to Camera Wired: Connect Timer to the camera 90mm 90mm 86mm2 Captur Module - Timer Captur - Timer Kit Controls APTUR Module - ProSETLock Start/Stop APTUR Module - Timer SET Lock Start/Stop APTUR Receiver APTUR Transmitter Lock Start/StopOff/OnReleaseButton
LED lightTest/DCM buttonOff/OnCamera / Tripod MountCable PortCable PortHotshoe (ash mount) Cables Timer Kit - Canon C1 & C3 Cables (Canon only) Timer Kit - Nikon N1 & N3 Cables (Nikon only) Timer Kit - Sony S2 Cable (Sony only) Timer Kit - Oly/Pana O1, P1 & C1 Cables (Olympus/Pana only) Timer Kit - Fujilm C1 & F1 Cables (Fujilm only) Please insert all batteries provided. Instructions in this manual assume that the Captur Receiver & Timer and any other equipment are already turned on. C1 CableC3 CableN1 Cable N2 CableN3 Cable S1 Cable S2 Cable O1 CableP1 Cable F2 Cable F1 Cable Batteries 4 x AA Alkaline BatteriesInterval timed photography chart APTURModule - Timer SET Lock Start/StopAPTURModule - Timer SET Lock Start/Stop 1/2 Push Autofocus
10sec 10sec 10sec 10sec 10sec 10sec Y INTVL2 20Sec1min20Sec20Sec 1min1Hr SHOOT SHOOT SHOOT SHOOT SHOOT SHOOT SHOOT SHOOT SHOOT
=3 shots Captur Module - Timer 3Captur Module - Timer 4 SET SET SET Interval Timer Toggle ButtonContents English 7 German 10 French 13 Polish 16 Dutch 19 Spanish 22 Czech 25 Portugese 28 Swedish 31 Finnish 34 Italian 37 Hebrew 40 PageCaptur Module - Timer 7 Captur Module - Timer
Delay before shooting starts
Duration of burst/exposure with
Number of shots at 1st Interval Number of times program is repeated
Low battery indicator
Shot count 0 to 999, --- (unlimited)
Toggle Button Setting up Captur - Timer Kit The Captur Module - Timer is used with the Captur Receiver to control the camera wirelessly. Alternatively you can also connect the Captur Module - Timer directly to a DSLR camera with the camera cable included. Single Shot Mode Select single shot on camera. The Release Button works similarly to the camera shutter release. ½ push = Autofocus, LED
shows steady green. Full push = Shutter release, LED
shows red. Continuous Shot Mode Select continuous mode on camera. Press and hold the Release Button - after 3secs timer LED ashes red = . Full press Release Button
GB8 Captur Module - Timer BULB Mode Select BULB mode on camera. Press and hold the Release Button to open the shutter - after 3secs timer LED ashes red = . Full press Release Button = to close shutter. For more advanced timed BULB shooting use the and settings. Interval Timer Programmable Functions Press Start/Stop button to ‘Start’ the ‘Interval Timed Photography’. The Captur Module - Timer will now take a photo continuously at the factory set interval time. Press Start/Stop again to ‘Stop’ the interval timed photography. The values of the following parameters can be adjusted as required. Use Toggle Button
< or > to move between the parameters which need to be adjusted. Press SET button
+ or - is used to adjust the value of the parameters. Press SET button
again to conrm adjustment. Parameters
Setting 0s to max 99hrs 59’min 59”s (in 1s increments) 1s to max 99hrs 59’min 59”s (in 1s increments) 1 to 999 and --- (unlimited) 1s to max 99hrs 59’min 59”s (in 1s increments) Description Delay before 1st shutter is released Burst/Bulb time 1st Interval Time = Number of shots for 1st Interval = Number of times program is repeated 2nd Interval Time Digital Channel Matching – DCM a. Timer - Press and hold Release Button + Turn ‘ON’. LED will ash green b. Receiver - Press and hold button + Turn ‘ON’. LED will show steady red c. DCM is complete. Turn both Timer & Receiver ‘OFF’ and ‘ON’ to reboot Note: For multiple Receivers repeat step ‘b’ for all receivers without turning off timer Camera & Flash Remote Control Requires an additional Captur receiver and Transmitter which are synced on a differnet channel. GBPlease note: To ensure camera and ash gun are in sync, ash receivers must be triggered from a transmitter tted to the camera hotshoe. ReceiverTransmitter Sync 1 Sync 2 Timer Captur Captur Timer - Kit Receiver Warning
- Do not modify product
- Keep Captur - Timer Kit dry at all times
- Do not use in the presence of ammable gas
- Keep out of the reach of children
- Do not expose to excessive temperatures or strong direct sunlight
- Do not leave the unit in the trunk or on the dashboard of a vehicle
- Overheating can result in leaking, re or explosion
- Observe correct battery polarity
- Dispose in accordance with appropriate environmental regulations
< or > to move between the parameters which need to be adjusted. Press SET button
+ or - is used to adjust the value of the parameters. Press SET button
again to conrm adjustment. Asetus
EasyManual