IFM DP2122 - Motion detector

DP2122 - Motion detector IFM - Free user manual and instructions

Find the device manual for free DP2122 IFM in PDF.

📄 33 pages English EN Download 💬 AI Question
Notice IFM DP2122 - page 1
View the manual : Français FR Deutsch DE English EN 日本語 JA
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about DP2122 IFM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Motion detector in PDF format for free! Find your manual DP2122 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DP2122 by IFM.

USER MANUAL DP2122 IFM

Operating instructions Speed monitor

DP2122

Contents

1 Preliminary note 4

1.1 Symbols used 4
1.2 Warnings.... 4
1.3 Safety symbol on the device 4

2 Safety instructions.... 5
3 Intended use.... 6
4 Function 7

4.1 Operating modes 7
4.2 Application as an IO-Link device 7

4.2.1 General information.... 7
4.2.2 IO Device Description (IODD) 8

4.3 Function diagrams.... 8

4.3.1 Single point mode 8
4.3.2 Window mode 9
4.3.3 Two point mode 10
4.3.4 Deactivated mode 10
4.3.5 Standard IO mode.... 11
4.3.6 Switching delays 11
4.3.7 Switch-off delay.... 11

4.4 Start-up delay 12

5 Installation.... 13
6 Electrical connection.... 14

6.1 Input side 14
6.2 Connecting the device.... 14

6.2.1 Mounting the connector.... 15

6.2.1.1 Maximum cable length 15

7 Operating and display elements 16

7.1 Push rings (pushbuttons) 16
7.2 LEDs.... 16
7.3 Display 17

8 Menu....18

8.1 General.... 18
8.2 Menu structure 19

8.2.1 Operating mode 1 19
8.2.2 Operating mode 2 20

8.3 Parameters of the main menu.... 20

8.3.1 SSC1 – speed monitor OUT1 20
8.3.2 SSC2 – speed monitor OUT2 21
8.3.3 EF - extended functions.... 21

8.4 Parameters for OUT1 (SSC1) 21

8.4.1 ModE — switch point mode ..... 21
8.4.2 LoGc - switch point logic 21
8.4.3 SP1 — switch point 1....21
8.4.4 SP2 - switch point 2.... 21
8.4.5 HyS - switch points hysteresis 21
8.4.6 dS — switching delay.... 22
8.4.7 dr — switch-off delay 22
8.4.8 P-n - output configuration.... 22

8.5 Parameters for OUT2 (SSC2) 22

8.6 Parameters of the extended functions (EF).... 22

8.6.1 rES - restore factory setting 22
8.6.2 Lo/Hi - min/max measured input values 22
8.6.3 dSt — start-up delay time.... 22
8.6.4 ScAL - set decimal point 22
8.6.5 C. FEP — custom user endpoint for frequency 23
8.6.6 PrSC — prescaler 23

8.6.7 coLr - display colours and colour changes 23
8.6.8 cFH/cFL — upper/lower value for colour change 24
8.6.9 diS.b - display power on.... 25
8.6.10 diS. U — refresh rate of the displayed measured value.... 25
8.6.11 CMPT - indication of the operating mode.... 25

8.7 Parameters adjustable via IO-Link 25

8.7.1 C.uni - customer-specific unit 25
8.7.2 FLASH_ON – activate flashing of the display 25
8.7.3 FLASH_OFF – deactivate flashing of the display 25
8.7.4 SSC counter – switching counter 25
8.7.5 internal_temperature – operating temperature microcontroller 25
8.7.6 operation_hours - operating hours 26
8.7.7 Application-specific tag 26
8.7.8 Location tag 26
8.7.9 Function tag 26

9 Parameter setting 27

9.1 Parameter setting in general 27

9.1.1 Example [ModE] - switch point mode for OUT2.... 27

9.2 Notes on programming 28

9.2.1 Locking / unlocking 28
9.2.2 Timeout.... 28
9.2.3 Numerical entries with [▼] or [▲] 28

10 Operation 29

11 Troubleshooting 30
12 Maintenance, repair and disposal 31
13 Factory settings.... 32

1 Preliminary note

You will find instructions, technical data, approvals and further information using the QR code on the unit / packaging or at documentation.ifm.com.

1.1 Symbols used

√ Requirement
Instructions
Reaction, result

[...] Designation of keys, buttons or indications

→ Cross-reference

IFM DP2122 - Symbols used - 1

Important note

Non-compliance may result in malfunction or interference.

IFM DP2122 - Symbols used - 2

Information

Supplementary note

1.2 Warnings

Warnings indicate the possibility of personal injury and damage to property. This enables safe product handling. Warnings are graded as follows:

IFM DP2122 - Warnings - 1

WARNING

Warning of serious personal injury

▷ If the warning is not observed, fatal and serious injuries are possible.

IFM DP2122 - Warnings - 2

CAUTION

Warning of minor to moderate personal injury

▷ If the warning is not observed, minor to moderate injuries are possible.

ATTENTION

Warning of damage to property

▷ If the warning is not observed, damage to property is possible.

1.3 Safety symbol on the device

IFM DP2122 - Safety symbol on the device - 1

Safety symbol on the device:

▶ Adhere to the operating instructions for the safe operation of the unit.

2 Safety instructions

- The unit described is a subcomponent for integration into a system.

  • The system architect is responsible for the safety of the system.
  • The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system. This documentation must contain all necessary information and safety instructions for the operator, the user and, if applicable, for any service personnel authorised by the architect of the system.

  • Read this document before setting up the product and keep it during the entire service life.

  • The product must be suitable for the corresponding applications and environmental conditions without any restrictions.
  • Only use the product for its intended purpose (→ Intended use).
  • If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur.
  • The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator.
    • Installation, electrical connection, set-up, programming, configuration, operation and maintenance of the product must be carried out by personnel qualified and authorised for the respective activity.
  • Protect units and cables against damage.
  • Replace damaged units, otherwise the technical data and safety will be impaired.
  • Observe applicable documents.

3 Intended use

The unit is a pulse evaluation system. It monitors rotating, linear, vibrating or oscillating movements. It receives the pulses from external sensors, measures the pulse interval and calculates the input frequency. This value is compared with the set switch points; the outputs are switched in accordance with the set parameters.

IFM DP2122 - Intended use - 1

Fig. 1: Example: speed monitoring of a drive shaft on a conveyor belt

1: Conveyor belt

3: DP2122

5: Transistor output / IO-Link

2: Pulse pick-up on the drive shaft

4: Transistor output (e.g. to control a light indicator, horn or relay)

6: Signals depending on the selected switching function

The unit is not suited for environments with particular requirements on mechanical stability (e.g. shock/vibration).

The unit is intended for indoor use only.

▶ Observe the operating conditions ( → Technical data at www.ifm.com).

4 Function

Depending on the setting of the IO-Link parameter [CMPT], the unit displays the current frequency in Hz or the rotational speed in RPM. It generates output signals according to the operating mode and the parameter setting. In addition, it makes the process data available via IO-Link (in Hz or RPM, depending on the operating mode).

The unit is designed for half-duplex communication. So the following options are possible:

  • Remote display: reading and displaying the current frequency/speed
  • Remote parameter setting: reading and changing the current parameter setting
    • IO-Link parameter setting: IO Device Description (IODD) (→ 8)

4.1 Operating modes

The following operating modes are available:

Operating mode 1: HZ_M (default)
DescriptionDisplays the frequency in Hz
ApplicationStandard applications with frequency measurement in Hz
IODD designationDP1222 Factory setting / (CMPT=HZ_M)
IO-Link device ID1167 d / 00 04 8f h
IO-Link parameter CMPTHZ_M (default)
Operating mode 2: rpnM
DescriptionDisplays the frequency in revolutions per minute (RPM)
ApplicationConverted values in RPM
IODD designationDP1222_Status_B / (CMPT=rpnM)
IO-Link device ID1294 d / 00 05 0e h
IO-Link parameter CMPTrpnM

IFM DP2122 - Operating modes - 1

In operating mode 2, the display of the device always shows kRPM.

IFM DP2122 - Operating modes - 2

Manual selection of the operating mode:

CMPT — indication of the operating mode ( → ☐ 25) and ModE — switch point mode ( → ☐ 21) for OUT2

IFM DP2122 - Operating modes - 3

Selection of the operating mode via IO-Link interface:

▷ see document "Addition to the operating instructions: Selecting the operating mode using an IO-Link interface" at www.ifm.com

IFM DP2122 - Operating modes - 4

If the operating mode is changed, the parameters of the device are reset to the factory settings with the exception of CMPT.

4.2.1 General information

The unit has an IO-Link communication interface which requires an IO-Link capable module (IO-Link master).

The IO-Link interface allows direct access to the process and diagnostic data and enables setting of the parameters of the unit during operation.

You will find further information about IO-Link and all the necessary information about the required IO-Link hardware and software at:

www.io-link.ifm

4.2.2 IO Device Description (IODD)

You will find the IODDs required for configuration of the IO-Link device as well as detailed information about the process data structure, diagnostic information and parameter addresses at

documentation.ifm.com

4.3 Function diagrams

4.3.1 Single point mode

IFM DP2122 - Single point mode - 1

Fig. 2: NO (IO-Link parameter LoGc: no / high active)

SP1: Overspeed: Reset point / underspeed: Switch point

SP1+H: Overspeed: Switch point / underspeed: Reset point

If a set rotational speed is not reached, this is signalled by the switching signal as open.

IFM DP2122 - Single point mode - 2

Fig. 3: NC (IO-Link parameter LoGc: nc / low active)

SP1: Overspeed: Reset point / underspeed: Switch point

SP1+H: Overspeed: Switch point / underspeed: Reset point

If a set rotational speed is not reached, this is signalled by the switching signal as closed.

IFM DP2122 - Single point mode - 3

1: Power-on delay time
3: normally open

2: Start-up delay

4: normally closed

4.3.2 Window mode

IFM DP2122 - Window mode - 1

Fig. 4: NO (IO-Link parameter LoGc: no / high active)

If the set speed range is left, the switching signal will signal this as open.

IFM DP2122 - Window mode - 2

Fig. 5: NC (IO-Link parameter LoGc: nc / low active)
SP1: Switch-on point window
SP1+H: Switch-off point
SP2: Switch-on point window
SP2-H: Switch-off point

SP1: Switch-off point window

SP1+H: Switch-on point

SP2: Switch-off point window

SP2-H: Switch-on point

If the set speed range is left, the switching signal will signal this as closed.

IFM DP2122 - Window mode - 3

1: Power-on delay time
3: Normally open

2: Start-up delay

4: Normally closed

4.3.3 Two point mode

IFM DP2122 - Two point mode - 1

Fig. 6: NO (IO-Link parameter LoGc: no / high active)
SP1: Overspeed: Switch point / underspeed: Reset point
SP2: Overspeed: Reset point / underspeed: Switch point

If a set rotational speed is not reached, this is signalled by the switching signal as open.

IFM DP2122 - Two point mode - 2

Fig. 7: NC (IO-Link parameter LoGc: nc / low active)
SP1: Overspeed: Switch point / underspeed: Reset point
SP2: Overspeed: Reset point / underspeed: Switch point

If a set rotational speed is not reached, this is signalled by the switching signal as closed.

4.3.4 Deactivated mode

NO (IO-Link parameter LoGc: no / high active)

The switching signal is always signalled as open.

NC (IO-Link parameter LoGc: nc / low active)

The switching signal is always signalled as closed.

4.3.5 Standard IO mode

The yellow LEDs indicate the switching status of the unit.

Switching function NO:

transistor outputLED yellowDescription
ClosedonRotational speed > SP1 and during start-up delay
OpenoffRotational speed < SP2

Switching function NC:

transistor outputLED yellowDescription
ClosedonRotational speed < SP2
OpenoffRotational speed > SP1 and during start-up delay

4.3.6 Switching delays

The switching delay enables filtering of input signals. The switching delay is activated or restarted by a positive switching edge of the input signal. Only if the input signal is still active after the delay time has elapsed, the output will be set to the active switching state. Pulses that are shorter than the switching delay will be filtered.

IFM DP2122 - Switching delays - 1

4.3.7 Switch-off delay

The switch-off delay enables filtering of input signals. The switch-off delay is activated or restarted by a negative switching edge of the input signal. Only if the input signal is still inactive after the delay time has elapsed, the output will be set to the inactive switching state. Pulse pauses that are shorter than the switch-off delay will be filtered.

IFM DP2122 - Switch-off delay - 1

4.4 Start-up delay

The start-up delay enables the suppression of error signals when a plant is started. It is effective after the power supply is applied and is dependent on a low speed.

If the drive is frequently switched on and off, it is advisable to couple the voltage supplies of the drive and the speed monitor. By doing so, the start-up delay is active every time the motor is turned on.

If a coupled connection of the voltage supplies is not possible, a start trigger point can be set in the process date or in SIO via ENABLE (Pin 2) via IO-Link. The positive switching edge of the corresponding signal serves as the start trigger point. In addition, the system can start up by itself; after detection of the first pulses the delay timer is started (value: 0...999.9 s in steps of 0.1 seconds).

5 Installation

▶ Install the device so that the M12 connection parts and the device are protected from mechanical stress such as shock and vibration.
▶ If necessary, fix the device with a mounting clip. Use M4 screw or cable tie for this purpose.
▶ During installation, ensure that the pollution degree is 2 or better.

IFM DP2122 - Installation - 1

Fig. 8: Mounting clip

IFM DP2122 - Installation - 2

Fig. 9: Mounting clip with attached unit

The mounting clip is not supplied with the device. More information about available accessories at www.ifm.com.

The following applies to all types of mounting: The responsibility for the compliance with the requirements concerning mounting of the device in the application with regard to shock, vibration, acceleration and weight lies with the system architect.

6 Electrical connection

IFM DP2122 - Electrical connection - 1

The unit must be connected by a qualified electrician.

▶ Observe the national and international regulations for the installation of electrical equipment.

The input and output circuits are insulated from each other and from device surfaces that could be touched with basic insulation according to IEC 61010-1 (secondary circuit with max. 32 V DC, supplied from the mains circuit up to 300 V of overvoltage category II).

The external wiring has to be carried out in a way that ensures the required separation from other circuits.

6.1 Input side

Operating voltage (SELV/PELV)

IFM DP2122 - Input side - 1

CAUTION

The input current of the operating voltage is not limited.

▷ No fire protection.
▶ Protect the circuit.
▶ Protect the sensor supply via the same fuse.

PotentialM12 connector 1Fuse
L+ / supply voltagePin 1 ≤ 2 A

Required tripping characteristic of the fuse:

Tfuse ≤ 120 s at max. 6.25 A (fire protection)

▶ Alternatively supply the device via a limited energy circuit according to IEC 61010-1 or class 2 according to UL1310.

IFM DP2122 - Input side - 2

Output reaction to overload or short circuit:

For self-protection of the output in case of excessive thermal load (due to short circuit or overload), the output driver starts clocking. If a short circuit / overload continues for several hours, the driver may be damaged!

6.2 Connecting the device

▶ Disconnect power.
▶ Connect the unit as follows:

IFM DP2122 - Connecting the device - 1

Fig. 10: Electrical connection

1: 4-pole M12 connector

• Pin 1: L+ / supply voltage
• Pin 2: OUT2 / digital output 2
• Pin 3: L- / supply voltage
• Pin 4: OUT1 / IO-Link (C/Q)

2: 5-pole M12 socket

  • Pin 1: L+
  • Pin 3: L-
    • Pin 4: IN1 / digital input 1
    • Pin 5: not connected

• Pin 2: ENABLE for start-up delay in SIO mode

The device must not be externally supplied via the 5-pole M12 socket ②.

Always use the provided connection cables to connect other devices.

See also application examples ( → Intended use)

6.2.1 Mounting the connector

The threaded connections in the device correspond to the M12 standard. To ensure compliance with the specified protection rating, only cables that comply with this standard may be used. In the case of self-assembled cables, the system manufacturer is responsible for the protection rating.

▶ Use connectors with gold-plated contacts.
▶ During installation, place the connectors vertically so that the coupling nut will not damage the thread.
▶ Observe the coding of the connectors during installation.

If connector in the device:

▶ Tighten the cable sockets according to the torque specifications indicated by the cable vendor. Maximum permissible tightening torque: 1.8 Nm

If sockets in the device:

▶ Tighten the cable plug using 1.3 ± 0.1 Nm.
▶ Provide all outgoing cables with suitable strain relief after a maximum of 200 mm. Observe the minimum bending radius of the cables ( → information from the cable manufacturer).

6.2.1.1 Maximum cable length

• Without IO-Link communication: 30 m on each side
• With IO-Link communication: 20 m on the master side

7 Operating and display elements

IFM DP2122 - Operating and display elements - 1

1: Push rings (pushbuttons)
2: LEDs
3: Display

IFM DP2122 - Operating and display elements - 2

Here, the Enter button [●] is shown pressed, as an example.

7.1 Push rings (pushbuttons)

To execute an [esc], [●], [▼] or [▲] command, press the corresponding corner of a push ring.

ButtonFunction
[esc]EscapeReturn to the previous menu. Exit parameter setting without saving the new value.
[●]EnterOpen menu mode. Selection of the parameter and acknowledgement of a parameter value.
[▼]DownSelection of a parameter. Setting a parameter value (scrolling by holding down, incrementally by pressing repeatedly).
[▲]Up

To ensure correct operation of the push rings (buttons), do not install or place the unit directly on a metal surface.

For the installation use the mounting clip → Installation.

7.2 LEDs

LEDColourStatusDesignation
IOUT1yellowonOutput 1 switched.
PowergreenonVoltage supply OK. Unit in operating mode.
offUnit in programming mode.
IIOUT2yellowonOutput 2 switched.

Error signals and diagnosis: Troubleshooting

7.3 Display

ColourDesignation
Red/green7-segment LED display, 4 digits, with colour change

Error signals and diagnosis: Troubleshooting

When [▼] or [▲] is pressed during the operating mode for 1 second, the unit of measurement will be displayed. The displayed unit of measurement depends on the parameter C.uni.

In the operating mode the input frequency is displayed. The display value is scaled automatically in the basic setting.

IFM DP2122 - Display - 1

Operating mode 1:

Manual scaling via parameter [C. FEP] is activated by parameter [ScAL].

IFM DP2122 - Display - 2

Manual scaling:

Display constraint to a step increment of 1 Hz.

IFM DP2122 - Display - 3

Operating mode 2:

Process or parameter values with more than 4 digits cannot be fully displayed. In the local menu the setting accuracy is limited to the 4 visible digits.

8 Menu

IFM DP2122 - Menu - 1

If a scaling is set, the menu settings of all frequency and speed dependent parameters (SP, cFH, etc.) are also scaled.

8.1 General

Irrespective of the operating mode (standard IO mode or IO-Link device) there are two options to set the parameters of the device:

  • directly on the device via the menu (→ Parameter setting)
    • or via an IO-Link tool

Access via an IO-Link tool has a higher priority than parameter setting via the menu.

IFM DP2122 - General - 1

Parameter cloning and parameter setting backup is possible with an IO-Link tool.

IFM DP2122 - General - 2

Some parameters can only be set via the IO-Link interface: Parameters adjustable via IO-Link ( → ☐ 25).

IFM DP2122 - General - 3

If the device was locked via IO-Link, it can also only be unlocked via the IO-Link interface: Locking / unlocking ( → ☐ 28).

8.2 Menu structure

8.2.1 Operating mode 1

IFM DP2122 - Operating mode 1 - 1

1: Operating mode → Operating modes

2: Main menu → Parameters of the main menu

3: Extended functions → Parameters of the extended functions (EF)

→ Parameter list and factory settings

8.2.2 Operating mode 2

IFM DP2122 - Operating mode 2 - 1

1: Operating mode → Operating modes

2: Main menu → Parameters of the main menu

3: Extended functions → Parameters of the extended functions (EF)

→ Parameter list and factory settings

8.3 Parameters of the main menu

8.3.1 SSC1 — speed monitor OUT1

The parameter opens the menu of the settings for OUT1 of the speed monitor.

8.3.2 SSC2 – speed monitor OUT2

The parameter opens the menu of the settings for OUT2 of the speed monitor.

8.3.3 EF — extended functions

The parameter opens the extended functions menu.

8.4 Parameters for OUT1 (SSC1)

8.4.1 ModE — switch point mode

Setting of the switch point mode.

• [1-P] = Single point mode ( → ☐ 8)
• [und] = Window mode (→ 9)
• [2-P] = Two point mode ( → 10)
• [OFF] = Deactivated mode ( → ☐ 10)

8.4.2 LoGc – switch point logic

Setting of the switch point logic: Function diagrams ( → ☐ 8).

• [no] = switch is closed when activated.
• [nc] = switch is opened when activated.

8.4.3 SP1 – switch point 1

Threshold for the upper switch point.

IFM DP2122 - LoGc – switch point logic - 1

In "Single point mode" SP1 is adjustable over its entire value range. In "Two point mode" and "Window mode" the lower limit is restricted by SP2. It always applies: SP1 > SP2.

8.4.4 SP2 – switch point 2

Threshold for the lower switch point.

Only active in the switch point modes "Two point mode" and "Window mode".

IFM DP2122 - LoGc – switch point logic - 2

In "Single point mode" the existing setting of SP2 is ignored. When changing to "Two point mode" or "Window mode", SP2 is automatically adjusted. It always applies: SP2 < SP1.

IFM DP2122 - LoGc – switch point logic - 3

SP1 limits the maximum setting value of SP2. It always applies: SP2 < SP1.

8.4.5 HyS – switch points hysteresis

Setting of the hysteresis with respect to switch points SP1 and SP2: Function diagrams ( → ☐ 8).

Only active in the switch point modes "Single point mode" and "Window mode".

Setting range: 0.5...100 %

Resolution: 0.1 %

8.4.6 dS — switching delay

Delay when the output changes to the active switching status.

Setting range: 0...99.99 s

Resolution: 0.01 s

8.4.7 dr — switch-off delay

Delay when the output changes to the idle state.

Setting range: 0...99.99 s

Resolution: 0.01 s

8.4.8 P-n — output configuration

• [PnP] = load connected to ground
• [nPn] = load connected to VBB

8.5 Parameters for OUT2 (SSC2)

With the exception of P-n: see Parameters for OUT1 (SSC1) (→ 21)

8.6 Parameters of the extended functions (EF)

8.6.1 rES — restore factory setting

Resets all parameters to the Factory settings ( → ☐ 32).

▶ Select [rES].
▶ Press [●].
▶ Press and hold [▲] or [▼] until [----] is displayed.
▶ Briefly press [●].

8.6.2 Lo/Hi — min/max measured input values

[Lo] = lowest measured value

[Hi] = highest measured value

Delete memory:

▶ Select [Hi] or [Lo].
▶ Press and hold [▲] or [▼] until [----] is displayed.
▶ Briefly press [●].

8.6.3 dSt — start-up delay time

Setting of the delay time between switch-on/reset of the unit and start of speed evaluation.

8.6.4 ScAL — set decimal point

Operating mode 1: Operating modes ( → ☐ 7)

• [OFF] = indication in Hz with automatic decimal point setting.
• [cccc] = indication without decimal place.
• [ccc.c] = indication with 1 decimal place.
• [cc.cc] = indication with 2 decimal places.
• [c.ccc] = indication with 3 decimal places.

IFM DP2122 - ScAL — set decimal point - 1

With a fixed display screen ( [ScAL] ≠ OFF ) only the decimal point is set. No automatic scaling takes place.

C. FEP – custom user endpoint for frequency ( → ☐ 23)

IFM DP2122 - ScAL — set decimal point - 2

If [ScAL] is set to [cccc], [ccc.c], [cc.cc] or [c.ccc], decimal places of the frequency-dependent process and parameter values cannot be displayed.

IFM DP2122 - ScAL — set decimal point - 3

Depending on the scaling factor, the parameters can be set via the display with an accuracy of 0.4 Hz (C. FEP=5000) to 4 Hz (C. FEP=500).

8.6.5 C. FEP — custom user endpoint for frequency

Settings for scaled display values.

The parameters are only displayed in operating mode 1 and when [ScAL] is set to [cccc], [ccc.c], [cc.cc] or [c.ccc].

IFM DP2122 - C. FEP — custom user endpoint for frequency - 1

All displayed frequency/speed values are interpolated based on a 2-point approximation. IO-Link process data and parameters are not influenced by scaling.

IFM DP2122 - C. FEP — custom user endpoint for frequency - 2

U(f) corresponds to the scaled value f corresponds to the value in Hz

1: Scaling factor 2
2: Scaling factor 1
3: Scaling factor 0.5

8.6.6 PrSC — prescaler

Setting of the number of targets. The number of targets is automatically included in the measured values.

Only active in operating mode 2.

8.6.7 coLr – display colours and colour changes

Assignment of the display colours "red" and "green" within the measuring range.

IFM DP2122 - coLr – display colours and colour changes - 1

Fig. 11: Hysteresis function with [r1ou]

IFM DP2122 - coLr – display colours and colour changes - 2

Fig. 12: Hysteresis function with [G1ou]

For b/w printouts: gn = green, rd = red

• [rEd] = continuously red (independent of the measured value).
- [GrEn] = continuously green (independent of the measured value).
• [r1ou] = red when OUT1 switches.
• [G1ou] = green when OUT1 switches.

IFM DP2122 - coLr – display colours and colour changes - 3

Fig. 13: Window function with [r1ou]

IFM DP2122 - coLr – display colours and colour changes - 4

Fig. 14: Window function with [G1ou]

For b/w printouts: gn = green, rd = red

[r-cF] = red when the measured value is between the values [cFL] and [cFH].

[G-cF] = green when the measured value is between the values [cFL] and [cFH].

8.6.8 cFH/cFL — upper/lower value for colour change

If [coLr] is set to [r-cF] or [G-cF]

▶ Select [cFH] and set the upper limit.
Setting range corresponds to the measured values. The lowest setting value is [cFL].
▶ Select [cFL] and set the lower limit.
Setting range corresponds to the measured values. The highest setting value is [cFH].

IFM DP2122 - cFH/cFL — upper/lower value for colour change - 1

Fig. 15: Function [r-cF]

IFM DP2122 - cFH/cFL — upper/lower value for colour change - 2

Fig. 16: Function [G-cF]

For b/w printouts: gn = green, rd = red

8.6.9 diS.b — display power on

• [OFF] = the measured value display is switched off in the operating mode.
- [On] = the measured value display is switched on in the operating mode.

IFM DP2122 - diS.b — display power on - 1

Press any button to activate the display for at least 30 s in the switched-off state.

8.6.10 diS. U — refresh rate of the displayed measured value

• [d1] = update of the measured values every 50 ms.
• [d2] = update of the measured values every 200 ms.
• [d3] = update of the measured values every 600 ms.

IFM DP2122 - diS. U — refresh rate of the displayed measured value - 1

Even with an unsteady frequency, [d1] provides optimum readability.

8.6.11 CMPT — indication of the operating mode

Indicates the operating mode: Operating modes ( → ☐ 7)

  • [HZ_M] = DP2122_FREQ (unit of measurement Hz and customer-specific).
    • [rpnM] = DP2122_REVL (unit of measurement rpm).

IFM DP2122 - CMPT — indication of the operating mode - 1

If the operating mode is changed, the parameters of the device are reset to the factory settings with the exception of CMPT.

The following functions or parameters are only available via IO-Link tools.

8.7.1 C.uni – customer-specific unit

Customer-specific unit with max. 4 characters.

8.7.2 FLASH_ON – activate flashing of the display

Used to identify a unit. Display flashes and shows [dEVC].

8.7.3 FLASH_OFF – deactivate flashing of the display

Deactivates the flashing of the display.

8.7.4 SSC counter – switching counter

Counts the state changes from low to high of the internal detection. Counter values are not saved permanently.

8.7.5 internal_temperature – operating temperature microcontroller

Reads the data from the internal temperature sensor of the microcontroller.

8.7.6 operation_hours – operating hours

Only counts full operating hours. Operating times of less than one full hour are not saved. Counter readings are saved permanently.

8.7.7 Application-specific tag

Customer-specific application description, max. 32 characters long. Default value: “ *** ” / can be freely defined by the customer

8.7.8 Location tag

Customer-specific location tag of the unit, max. 32 characters long. Default value: “ *** ” / can be freely defined by the customer

8.7.9 Function tag

Customer-specific function tag of the unit, max. 32 characters long. Default value: “ *** ” / can be freely defined by the customer

9 Parameter setting

During parameter setting the unit remains in the operating mode. It continues its monitoring functions with the existing parameters until the parameter setting has been completed.

9.1 Parameter setting in general

Each parameter setting consists of 6 steps:

StepButton
1Change from operating mode to parameter setting mode.[●]
2Select the requested parameter [SP1], [C. FEP], etc.[▲] or [▼]
3Change to the programming mode of the parameter.[●]
4Select or change the parameter value.[▲] or [▼] > 2 s
5Acknowledge the set parameter value.[●]
6Return to the operating mode.[esc]

9.1.1 Example [ModE] - switch point mode for OUT2

StepDisplay
1Change from operating mode to parameter setting mode.
► ▶ Press [●] to get to the menu. ▷ The first parameter is displayed.IFM DP2122 - Example [ModE] - switch point mode for OUT2 - 1
2Select the requested parameter, here [SSC2].
► ▶ Press [▼] until [SSC2] is displayed.► ▶ Press [●] to get to the extended functions menu. ▷ The first parameter of the extended functions is displayed.IFM DP2122 - Example [ModE] - switch point mode for OUT2 - 2IFM DP2122 - Example [ModE] - switch point mode for OUT2 - 3
3Change to the programming mode of the parameter.
► ▶ Press [●] to change to the programming mode. ▷ The currently set parameter value is displayed.IFM DP2122 - Example [ModE] - switch point mode for OUT2 - 4
4Select or change the parameter value, here e.g. [und].
► ▶ Press [▼] or [▲] for at least 2 s. ▷ The currently set parameter value flashes, here e.g. [1-P]. ▷ After 2 s:- value is changed continuously by keeping the button pressed.- value is changed incrementally by pressing the button once. Numerical values (→9.2.3)IFM DP2122 - Example [ModE] - switch point mode for OUT2 - 5IFM DP2122 - Example [ModE] - switch point mode for OUT2 - 6
5Acknowledge the set parameter value.
► ▶ Briefly press [●]. ▷ The parameter is displayed again. ▷ The new setting value is saved.IFM DP2122 - Example [ModE] - switch point mode for OUT2 - 7
Setting of other parameters:► ▶ Press [▼] or [▲] until the requested parameter is displayed.
6Return to the operating mode.
► ▶ Press [esc].► ▶ - Press [▼] or [▲] several times until the current measured value is displayed.- Or wait for the timeout function (approx. 30 s). ▷ The unit has returned to the operating mode. ▷ The current value is displayed.IFM DP2122 - Example [ModE] - switch point mode for OUT2 - 8

9.2 Notes on programming

9.2.1 Locking / unlocking

The unit can be locked electronically to prevent unauthorised setting. Set parameter values and settings can be displayed but not changed.

To lock the unit:

▶ Make sure that the unit is in normal operating mode.

▶ Press [esc] + [▲] simultaneously for 10 s.

▷ [Loc] is displayed.

▷ The unit is locked.

▷ [Loc] is briefly displayed if you try to change parameter values.

To unlock the unit:

▶ Press [esc] + [▲] simultaneously for 10 s.

▷ [uLoc] is displayed.

On delivery the unit is not locked.

IFM DP2122 - Locking / unlocking - 1

Customer locking

If [C. Loc] is displayed when an attempt is made to modify a parameter value, an IO-Link communication is active (temporary locking).

IFM DP2122 - Locking / unlocking - 2

Software locking

If [S. Loc] is displayed, the sensor is permanently locked via software. This locking can only be removed using an IO-Link parameter setting software.

9.2.2 Timeout

If no button is pressed for 30 s during parameter setting, the unit returns to the operating mode with the unchanged value.

9.2.3 Numerical entries with [▼] or [▲]

▶ Press [▼] or [▲] for at least 2 s.

▷ After 2 s:

  • value is changed continuously by keeping the button pressed.
  • value is changed incrementally by pressing the button once.

Value is incrementally reduced with [] and increased with [] .

10 Operation

After power on, the unit is in the operating mode (SIO). It carries out its measurement and evaluation functions and provides output signals according to the set parameters: Menu.

11 Troubleshooting

DisplayLEDErrorTroubleshooting
IPowerII
OFFoffoffoffSupply voltage too low.Check/correct the supply voltage: → Electrical connection
SCflashescan differflashesExcessive current at the switching output OUTx (see LED I/II).Check switching output for short circuit or excessive current. Remove the fault.
C. Loccan differcan differcan differParameter setting via pushbuttons locked due to active IO-Link transmission.Wait until parameter setting via IO-Link is finished.
S. Loccan differcan differcan differParameter setting via pushbuttons disabled by software.Unlocking only possible via IO-Link interface/IO-Link parameter setting software.
Loccan differcan differcan differParameter setting via pushbuttons disabled.Unlock pushbuttons.
OLcan differoncan differProcess value too high (measured frequency > 5000 Hz / > 300000 RPM).Check connected sensor and value range.
Rotating segmentcan differcan differcan differTemperature in housing exceeds limit value.Press any button to switch the display on for 30 s.

12 Maintenance, repair and disposal

Cleaning the unit:

▶ Disconnect the unit from the voltage supply.
▶ Clean the unit from dirt using a soft, chemically untreated and dry micro-fibre cloth.

The operation of the unit is maintenance-free.

Only the manufacturer is allowed to repair the unit.

▶ After use dispose of the device in an environmentally friendly way in accordance with the applicable national regulations.

13 Factory settings

ParametersFactory settingsUser settings
SSC1. ModESwitch point mode OUT11-P• 1-Pund2-POFF
SSC1. LoGcSwitch point logic OUT1no• no• nc
SSC1. SP1Switch point 1 OUT 111
SSC1. SP2Switch point 2 OUT 110
SSC1. HySSwitch point hysteresis OUT110 %
SSC1.dSSwitching delay OUT10 s
SSC1.drSwitch-off delay OUT10 s
SSC1. P-nOutput configurationPnP• PnP• nPn
SSC2. ModESwitch point mode OUT21-P• 1-Pund2-POFF
SSC2. LoGcSwitch point logic OUT2no• no• nc
SSC2. SP1Switch point 1 OUT222
SSC2. SP2Switch point 2 OUT220
SSC2. HySSwitch point hysteresis OUT210 %
SSC2.dSSwitching delay OUT20 s
SSC2.drSwitch-off delay OUT20 s
rESFactory setting
LoLowest measured input value----
HiHighest measured input value----
dStStartup delay time 0 s
PrSC(only operating mode 2)Prescaler1
ScAL(only operating mode 1)Set decimal pointOFF• OFF• cccc• ccc.c• cc.cc• c.ccc
C. FEP(only operating mode 1)User endpoint for frequency2000
C.uni(only operating mode 1)Customer-specific unitUnit
coLrDisplay: colour settingrEd• rEd• grEn• r1ou• G1ou• r-cF• G-cF
cFHColour change: upper limit value11
cFLColour change: lower limit value10
diS.bDisplay power onOn• On• OFF
diS. URefresh rate of the displayed valued2 (200 ms)• OFF• d1 (50 ms)• d2 (200 ms)• d3 (600 ms)
CMPTIndication of the operating modeHZ_M• HZ_M• rpnM
Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : IFM

Model : DP2122

Category : Motion detector