OGH700 - Laser pointer IFM - Free user manual and instructions
Find the device manual for free OGH700 IFM in PDF.
User questions about OGH700 IFM
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Laser pointer in PDF format for free! Find your manual OGH700 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. OGH700 by IFM.
USER MANUAL OGH700 IFM
CE
Operating instructions Diffuse reflection sensor with background suppression
OGH7xx
1 Preliminary note
1.1 Symbols used
▶ Instruction
▷ Reaction, result
[...] Designation of pushbuttons, buttons or indications
→ Cross-reference

Important note
Non-compliance can result in malfunctions or interference.
2 Safety instructions
According to the cULus approval
Caution - Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure.

Visible laser light; CLASS 1 LASER PRODUCT.
EN/IEC 60825-1 : 2007 and EN/IEC 60825-1 : 2014
Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1
Ed. 3., as described in Laser Notice No. 56, dated May 8, 2019.
Position of the product label

Additional label

3 Functions and features
The diffuse reflection sensor detects objects and materials without contact and indicates their presence by a switching signal.
Range 20 ... 200 mm (on white paper 200 x 200 mm, 90 % remission)
4 Installation

1: LED
2: programming buttons
▶ Align the diffuse reflection sensor to the object to be detected.
▶ Secure it to a bracket.
Note:
The objects to be detected are to move transversally to the lens of the sensor.
▶ In case of other directions of movement it should be tested before whether safe switching is guaranteed.


5 Electrical connection

The unit must be connected by a qualified electrician.
▶ The national and international regulations for the installation of electrical equipment must be adhered to.
▶ Voltage supply according to EN 50178.
▶ Disconnect power.
▶ Connect the unit as follows:
DC PNP

pin 1 = L+ ( 10...36 V DC )
pin 3 = L-
pin 4 = load (200 mA)
(pin 2 = not connected)
DC NPN

pin 1 = L + ( 10...36 V DC )
pin 3 = L-
pin 4 = load (200 mA)
(pin 2 = not connected)
6 Settings
6.1 The sensor is to switch when the object is detected
| 1 | ▶ Position the object![]() |
| ▶ Press [OUT on] for 2 s. ▷ The sensitivity is set to the object. ▷ The LED flashes. | |
| 2 | ▶ Remove the object![]() |
| ▶ Press [OUT off]. ▷ The sensitivity is set without object. ▷ The LED goes out. The programming is finished. |
6.2 The sensor is not to switch when the object is detected
▶ Position the object (see figure 1) and press [OUT off] for 2 s.
▶ Remove the object (see figure 2) and press [OUT on].
The setting can also be carried out first without object and then with object.
6.3 Setting of the maximum sensitivity
▶ Align the sensor so that no light is reflected.
The sensor is to switch when the object is detected
▶ First press [OUT on], then [OUT off].
The sensor is to switch when the object is not detected
▶ First press [OUT off], then [OUT on].
6.4 Programming unsuccessful
▷ The LED flashes quickly, 8 Hz.
• Measured value difference too small
• Max. programming time (15 min.) exceeded.
6.5 Electronic lock
Lock or unlock the buttons
▶ Press [OUT on] and [OUT off] simultaneously for 10 s.
▷ Acknowledgement is indicated by a change of the LED status.
7 Operation
▶ Check whether the unit operates correctly.
▷ The LED lights when the switching output is switched.
8 Maintenance, repair and disposal
▶ Keep the front pane of the sensor free from soiling.
▶ For cleaning do not use any solvents or cleaning agents which could damage the plastic material.
▶ Do not try to open the module enclosure. There are no user - serviceable components inside.