10032968 - Lamp Klarstein - Free user manual and instructions
Find the device manual for free 10032968 Klarstein in PDF.
| Technical Specifications | Klarstein lamp 10032968, power 10W, color temperature 3000K, luminous flux 800 lumens |
|---|---|
| Usage | Ideal for indoor lighting, warm ambiance, reading light |
| Maintenance and Repair | Clean with a soft cloth, avoid abrasive products, replaceable bulb |
| Safety | Complies with CE safety standards, do not expose to water, avoid electrical overloads |
| General Information | Modern design, available in several colors, 2-year warranty |
Frequently Asked Questions - 10032968 Klarstein
User questions about 10032968 Klarstein
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Lamp in PDF format for free! Find your manual 10032968 - Klarstein and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 10032968 by Klarstein.
USER MANUAL 10032968 Klarstein
text_image
QR code image containing encoded data, no visible human-readable textINHALTSVERZEICHNIS
Technische Daten 4
natural_image
Symbol of a trash bin crossed with a diagonal line, no text or numbers presenttext_image
Technical diagram of a circular device with labeled components, showing front and side views with numbered parts.European Authorised Representative:
CE
I-Plus Company Ltd.
4B Christchurch House, Beaufort Court,
Medway City Estate, Rochester, Kent. ME2 4FZ, UK
Hersteller:
0123
Zero-Plus International Limited
Room 1004, 10/F., Join-In Hang Sing Centre,
71-75 Container Port Road, Kwai Chung,
New Territories, Hong Kong
Hergestellt für:
Congratulations on purchasing this equipment. Please read this manual carefully and take care of the following hints to avoid damages. Any failure caused by ignoring the items and cautions mentioned in the instruction manual is not covered by our warranty and any liability. Scan the QR code to get access to the latest user manual and other information about the product

text_image
QR code image containing encoded data, no visible human-readable textCONTENT
Technical Data 16
About the Daylight 17
Signs and Symbols 18
Safety Standards 19
Safety Instructions 20
Product Overview 21
Operation 22
Troubleshooting 23
Safety and Performance Standards 24
HINTS ON DISPOSAL

natural_image
Symbol of a trash bin crossed out by a diagonal line, with no text or labels present.According to the European waste regulation 2012/19/EU this symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local council or your household waste disposal service.
TECHNICAL DATA
| Item number 10032968 | |
| Dimensions (W x H x D) 25 | x 25 x 8 cm |
| Weight 600 g | |
| Lighting elements LEDs | |
| Light intensity > 10.000 lux in 12 cm | |
| Mains connection 220-240 | V ~ 50 Hz / 0.2 A |
| Operating Environment 0 to | +40 °C, and relative humidity from 30% to 90%. Atmospheric pressure: 700-1060 hPa |
| Storage Environment -10 to | +60 °C, and relative humidity from 30% to 90%. Atmospheric pressure: 700-1060 hPa |
| Transport Environment -10 to | +60 °C, and relative humidity of max. 90%. Atmospheric pressure: 700-1060 hPa |
| Product Classification 1. Class II equipment | |
| Location of emission aperture | Screen |
| Treatment Area 600 cm | 2 |
| Product Service Life 5 years | |
Maximum output of optical radiation for the Energy Daylight
| Radiance Output Risk group classified by IEC 60601-2-57:2011 | Max. Value | |
| EUVA: Eye UV-A | Exempt Group | 1.5 × 10^4 W·m^-2 |
| ES: Actinic UV skin & eye Exempt Group | 1.5 × 10 | -4 W·m^-2 |
| EIR: Infrared radiation hazard exposure limits for the eye | Exempt Group | 6 × 10^-4 W·m^-2 |
| EH: Thermal hazard for the skin | Exempt Group | 3.5 × 10^1 W·m^-2 |
| LB: Blue light | Risk Group 1 | 10 × 10^2 W·m^-2 · sr^-1 |
| LR: Retinal thermal | Exempt Group | 2 × 10^2 W·m^-2 · sr^-1 |
ABOUT THE DAYLIGHT
Instructions for Use
Congratulations on the purchase of your new "Daylight". The product will offer many years of reliable usage if handled correctly. Please keep your receipt, these instructions and the original packaging safe in case of future requirement. Please read the instructions carefully to gain the most benefit from your new "Daylight", although the usage guidelines in this document do not replace the advice of your qualified medical advisor.
Intended Use
Medical intended use of this appliance is to treat SAD (seasonal affective disorder) or winter depression. "Daylight" is intended to boost people energy level, to adjust circadian rhythms and make people feel more awake. "Daylight" is safe and medically proven to relief from the winter blues.
How does the Dayligh work?
In autumn and winter, the seasons with the least sunlight because of shorter days, the lack of sunlight and a problem with certain brain chemicals stops the hypothalamus working properly. The lack of light is thought to affect the production of the hormone melatonin (that makes you sleepy). "Daylight" uses very bright lights to simulate the sunlight during the darker autumn and winter, whilst eliminating the dangerous UV rays contained in sunlight. The additional light helps your brain to reduce to production of hormone melatonin, adjust the levels of melatonin that can help the symptoms of SAD or winter depression.
Seasonal Affective Disorder
Seasonal Affective Disorder (SAD) as known as winter depression or winter blues. It may cause people:
• Feel low, listless and fatigued
- Need for more sleep
• Have trouble concentrating
• Less active than normal
- Lacking in energy
Contraindication
The following conditions may be contraindication for use of this appliance:
• Suffer(ed) from severe depression
- Recent eye surgery or a diagnosed eye condition which your doctor advised you to avoid bright light on
- Specific medication (i.E. Certain antidepressants, psychotropic drugs or malaria tablets);
• Have high blood pressure
- Skin sensitive to light, such as systemic lupus erythematosus
Possible side effects
The following side effects you may experience:
- Headaches
- Eyestrain
- Sleeping problems
- Nausea
Measures to avoid, minimize or alleviate these side effects
• Increase the treatment distance
- Avoid using the appliance during the late evening or before sleep
- Stop using the appliance for a few days to make the side effects disappear and then try again.
SIGNS AND SYMBOLS
The following symbols appear in this manual, on the appliance:
![]() | Read operating instructions before use | Caution: Consult accompanying documents | |
![]() | OFF/ON | IP21 | Ingress Protection Rating |
![]() | Class II Equipment Date of Manufacture | ||
![]() | Specifies serial number of the “Energy Daylight” | Manufacturer | |
![]() | Authorized Representative in the European Community |
SAFETY STANDARDS
This appliance has been designed and manufactured to conform to the highest standards of safety and performance including electromagnetic compatibility (EMC).
This appliance conforms to the applicable requirements of the following:
C€ 0123
This appliance meets the requirement of Medical Device Directive 93/42/EEC for medical appliances.
EMC information
- Warning: Use of this appliance adjacent to or stacked with other device should be avoided because it could result in improper operation. If such use is necessary, this appliance and the other device should be observed to verify that they are operating normally. If the appliance does not light on or flickering, it means that the appliance is not operating normally.
- Warning: Don't near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high.
- Warning: Do not change any cable without authorization of the manufacturer. Use of cables other than those specified or provided by the manufacturer of this appliance could result in increased electromagnetic emissions or decreased electromagnetic immunity of this appliance and result in improper operation.
- Warning: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm to any part of this appliance, including power cable. Otherwise, degradation of the performance of this equipment could result.
- If the appliance does not light on or flickering due to the electromagnetic disturbances, do not use it and try to place the appliance in other location.
- For maintaining the basic safety and essential performance with regard to electromagnetic disturbances for the expected service life, please precaution to take if the use location is near (e.g. less than 1,5 km from) from AM, FM or TV broadcast antennas
SAFETY INSTRUCTIONS
- Do not use the lamp in damp places.
- Before use, remove all packaging parts and check the device for Damages. If you are unsure, contact customer service.
- The device may only be used by suitable persons.
• Children should be supervised during use. This lamp is not a toy. - You do not need any special training for this machine.
- Keep the power cord away from heat and open fire.
- The minimum distance between the lamp and flammable objects must be 1 m.
Important Notes on Operation
- This device is not intended for commercial or clinical use, but exclusively for self-use in private households! The use of the daylight lamp is NOT a medical treatment.
- If you are taking medication such as painkillers, antihypertensives and antidepressants, you should discuss the use of the daylight lamp with your doctor beforehand.
- People with retinal diseases should be examined by an ophthalmologist before using daylight, just like diabetics.
- Please do not use for eye diseases such as cataracts, glaucoma, diseases of the optic nerve in general and inflammations of the vitreous body.
• If you have any health concerns, please consult your family doctor! - The operating voltage must correspond to that indicated on the nameplate.
• After use, unplug the power cord and allow the lamp to cool down. - Never touch the lamp with wet hands. Keep this away from moisture.
- Protect the lamp from strong shocks.
- Never pull on the power cord, touch it to disconnect the plug.
- If the power cord is damaged, it must be replaced immediately by qualified personnel.
• Never attempt to repair the lamp yourself. - Disconnection from the mains can only be done by disconnecting the mains plug. Always use an easily accessible power outlet.
- Do not use the device near volatile substances, pure oxygen or nitrous gases.
• The device does not require any adjustment. - The device has no components that can be repaired or maintained.
- The operator should not touch the user and the lamp at the same time.
• The device must not be modified.
Maintenance and Repairs
- Please do not attempt to repair the appliance yourself. This could result in serious injuries. Failure to observe this regulation shall void the warranty.
- If this appliance is damaged in any way or it is not working, it should not be operated. Please try to fix the problem according to Troubleshooting table. If the problem still not resolved, please contact customer service or the dealer, since special tools are needed to make repairs. Never try to repair the appliance yourself.
- Avoid exposing the screen to direct sunlight, spotlight or any other heat source.
- Do not use alcohol or ammonia base liquid to clean the screen. The cleaning information provided in the section "Cleaning".
PRODUCT OVERVIEW

text_image
Technical diagram of a circular device with labeled components, showing front and side views with numbered parts.| 1 | On/OFF Switch | 3 | Stand |
| 2 | Screen | 4 | Power Cord |
OPERATION
Before use, please check the appliance for damage or faults. If you notice any damage or faults on the appliance, do not use it and contact customer services or your supplier.
- Fold the stand out. Place the appliance on a solid surface such as table. Place the appliance at an angle to your body to avoid looking at the appliance directly.
- Place the appliance approximately 12-45 cm from your eyes. You can read, eat, work at computer, watch TV or exercise while you use the appliance.
- Plug in the appliance and switch on the light with higher intensity by pressing the ON/OFF button. To choose a lower intensity, press the ON/OFF button again.
Recommended Times to Use
| Duration of light therapy | Distance (High Intensity) | Distance (Low Intensity) |
| approximately 30 min 18 cm 12 cm | ||
| approximately 1 hr 30 cm 20 cm | ||
| approximately 2 hr 45 cm 35 cm |
In effect, the closer you are to the source of light, the less time you need to use it.
Notes on Use
- Push the plug completely into the mains socket.
- Ensure that there is a socket near the place where the appliance will stand.
- Lay the mains cable in such a way that no one can trip over it.
- Do not place the appliance on the position that is difficult to disconnect it.
- Do not look directly into the light continuously! Some eye pain or mild headaches may be experienced during initial sessions but these should pass. If in doubt just lower your treatment times until you feel comfortable again.
- During the darkest period of the year, repeat use the appliance every day at the right time to achieve the result. It is usually sufficient to use 30 minutes a day, it depends on light intensity and distance. It is safe to use to use it longer, if you want it. Do not use the appliance late within 3 hours of going to bed; it could disrupt your sleep.
Note: Press and hold the ON/OFF button for 2 seconds to turn off the appliance at any time.
Storage
When this appliance is not being used, it should be stored in a dry location out of reach of children. Do not keep the appliance connected to a power source. Follow the storage instructions provided in the "Technical Specification" Chapter.
TROUBLESHOOTING
| Problem Possible causes Solutions | ||
| Device does not light up. | On/ Off button switched off. Switch on the on/off button. | |
| No Power. Connect the main plug correctly. | ||
| No Power. The main cable is defective. Contact customer services or your retailer. | ||
| LEDs have reached the end of its service life. | If you need to have the appliance repaired, contact customer service or an authorized dealer. | |
| LEDs faulty. | ||
SAFETY AND PERFORMANCE STANDARDS
The Daylight has been designed and manufactured to conform to the highest standards of safety and performance including electromagnetic compatibility (EMC). The Daylight conforms to the applicable requirements of the following:
C€ 0123
This appliance meets the requirement of Medical Device Directive 93/42/EEC for medical appliances.
The appliance is complied with the following emission and immunity standard, and test level:
| Immunity Test standard IEC 60601-1-2 Test Level Compliance Level | ||
| Electrostatic discharge (ESD)IEC 61000-4-2 | ±8kV contact±2kV, ±4kV, ±8kV, ±15kV air | ±8kV contact±2kV, ±4kV, ±8kV, ±15kV air |
| Electrical fast transient/burstIEC 61000-4-4 | ±2kV for power supply lines±1kV100 kHz repetition frequency | ±2kV for power supply linesNot applicable100 kHz repetition frequency |
| SurgeIEC 61000-4-5 | ±0.5kV, ±1kV differential lines±0.5kV, ±1kV, ±2kV common mode | ±0.5kV, ±1kV differential linesNot applicable |
| Voltage dips, interruptions and variations on power supply input linesIEC 61000-4-11 | 0 % UT; 0.5 cycle. At 0°,45°, 90°, 135°, 180°, 225°,270° and 315°.0 % UT; 1 cycle and 70 % UT;25/30 cycles; Single phase:at 0°.0 % UT; 250/300 cycles | 0 % UT; 0.5 cycle. At 0°,45°, 90°, 135°, 180°, 225°,270° and 315°.0 % UT; 1 cycle and 70 % UT;25/30 cycles; Single phase:at 0°.0 % UT; 250/300 cycle |
| Power frequency (50/60 Hz)magnetic fi eldIEC 61000-4-8 | 30A/m50Hz / 60Hz | 30A/m50Hz / 60Hz |
| Conducted RFIEC 61000-4-6 | 3V, 0.15MHz - 80MHz6V in ISM and amateur radiobands between 0.15MHz and80MHz; 80 % AM at 1 kHz | 3V, 0.15MHz - 80MHz6V in ISM and amateur radiobands between 0.15MHz and80MHz; 80 % AM at 1 kHz |
| Radiated RFIEC 61000-4-3 | 10 V/m80MHz to 2.7GHz80 % AM at 1kHz | 10 V/m80MHz to 2.7GHz80 % AM at 1kHz |
| Emissions Test Standard Compliance | |
| RF emissions CISPR 11 Group 1, Class B | |
| Harmonic emissions IEC 61000-3-2 Not Applicable | |
| Voltage fluctuations/ flicker emissions IEC 61000-3-3 Not Applicable | |
| Guidance and manufacturer's declaration - electromagnetic Immunity | |||||||
| Radiated RF IEC61000-4-3 (Test specification for enclosure port immunity to RF wireless communications equipment) | Test Frequency (MHz) | Band (MHz) | Service Modulation | Modulation (W) | Distance (m) | Immunity Test Level (V/m) | |
| 385 380 | 390 TETRA 400 | Pulse modulation 18 Hz | 1.8 0.3 27 | ||||
| 450 380 | 390 | GMRS 460, FRS 460 | FM ± 5 kHz deviation 1 kHz sine | 2 0.3 28 | |||
| 710 | 704 - 787 | LTE Band 13,17 | Pulse modulation 217 Hz | 0.2 | 0.3 | 9 | |
| 745 | |||||||
| 780 | |||||||
| 810 | 800 - 960 | GSM 800/900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5 | Pulse modulation 18 Hz | 2 0.3 28 | |||
| 870 | |||||||
| 930 | |||||||
| 1720 | 1700 - 1990 | GSM 1800; CDMA 1900; GSM 1900; DECT; LTE Band 1,3,4, 25; UMTS | Pulse modulation 217 Hz | 2 0.3 28 | |||
| 1845 | |||||||
| 1970 | |||||||
| 2450 | 2 400 - 2 570 | BT, WLAN, 802.11 b/g/n, RFID 2450, LTE Band 7 | Pulse modulation 217 Hz | 2 0.3 28 | |||
| 5240 | 5 100 - 5 800 | WLAN 802.11 a/n | Pulse modulation 217 Hz | 0.2 | 0.3 9 | ||
| 5785 | |||||||
European Authorised Representative:
CE
I-Plus Company Ltd.
4B Christchurch House, Beaufort Court,
Medway City Estate, Rochester, Kent. ME2 4FZ, UK
Manufacturer:
0123
Zero-Plus International Limited
Room 1004, 10/F., Join-In Hang Sing Centre,
71-75 Container Port Road, Kwai Chung,
New Territories, Hong Kong
Manufactured for:
This product is conform to the following European
Directives:
2011/65/EU (RoHS)
93/42/EEC (Medical Devices)
Rev: 201810
Estimado cliente:
text_image
QR code image containing encoded data, no visible human-readable textÍNDICE DE CONTENIDOS
Datos técnicos 28
natural_image
Symbol of a trash bin crossed with a diagonal line, no text or labels presenttext_image
Technical diagram of a circular device with labeled components, showing front and side views with numbered parts.4B Christchurch House, Beaufort Court,
Medway City Estate, Rochester, Kent. ME2 4FZ, UK
Fabricante:
0123
Zero-Plus International Limited
Room 1004, 10/F., Join-In Hang Sing Centre,
71-75 Container Port Road, Kwai Chung,
New Territories, Hong Kong
Fabricado para:
text_image
QR code image containing encoded data, no visible human-readable textSOMMAIRE
Fiche technique 40
natural_image
Symbol of a trash bin crossed with a diagonal line, no text or labels presenttext_image
Technical diagram of a circular device with labeled components, showing front and side views with numbered parts.DÉCLARATION DE CONFORMITÉ
4B Christchurch House, Beaufort Court,
Medway City Estate, Rochester, Kent. ME2 4FZ, UK
Fabricant :
0123
Zero-Plus International Limited
Room 1004, 10/F., Join-In Hang Sing Centre,
71-75 Container Port Road, Kwai Chung,
New Territories, Hong Kong
Fabriqué pour :
text_image
QR code image containing encoded data, no visible human-readable textINDICE
Dati tecnici 52
Lampada di luce 53
Segni e simboli 54
natural_image
Symbol of a trash bin crossed with a diagonal line, no text or numbers presenttext_image
Technical diagram of a circular device with labeled components, showing front and side views with numbered parts.4B Christchurch House, Beaufort Court,
Medway City Estate, Rochester, Kent. ME2 4FZ, UK
Produttore:
0123
Zero-Plus International Limited
Room 1004, 10/F., Join-In Hang Sing Centre,
71-75 Container Port Road, Kwai Chung,
New Territories, Hong Kong