OLIMPIA SPLENDID Limpia Pure - Humidifier

Limpia Pure - Humidifier OLIMPIA SPLENDID - Free user manual and instructions

Find the device manual for free Limpia Pure OLIMPIA SPLENDID in PDF.

📄 52 pages English EN 💬 AI Question
Notice OLIMPIA SPLENDID Limpia Pure - page 12
View the manual : Français FR Deutsch DE English EN Español ES Italiano IT
Manual assistant
Powered by ChatGPT
Waiting for your message
Product information

Brand : OLIMPIA SPLENDID

Model : Limpia Pure

Category : Humidifier

Download the instructions for your Humidifier in PDF format for free! Find your manual Limpia Pure - OLIMPIA SPLENDID and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Limpia Pure by OLIMPIA SPLENDID.

USER MANUAL Limpia Pure OLIMPIA SPLENDID

1 - CAUTION This is an electrical appliance and requires attention when in use.

2 - CAUTION To reduce the risk of severe burns, keep this product out of the reach of chil-

3 - CAUTION Do not allow children to play with any product packaging such as plastic bag

4 - Disassembly, repair or remodelling by an unauthorized person may result in serious harm

and will void the manufactures warranty.

5 - Do not operate the appliance in case of damaged cord or plug, after the appliance

malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment or repairing.

6 - Always place this humidier on a rm, at and level surface at least 60cm from the oor.

This humidier may not work properly on an uneven surface.

7 - Do not block air inlet or outlet.

8 - Do not place this product on cloth, carpet or an absorbent surface. This may block air

9 - Do not place humidier near heat sources such as stoves, radiators and heaters

10 - Do not place humidier near electrical outlet

11 - This product releases mist. Do not place this humidier directly on wood furniture, oor-

ing or any surfaces that could be damaged by water. Manufacturer does not accept any liability for damage in the case of the unit being placed incorrectly.

12 - Before lling or cleaning the unit, make sure it is unplugged.

13 - Once the humidier has been plugged in, do not tilt or move the unit.

14 - Do not remove the water tank from the unit while it is on.

15 - Do not handle the plug with wet hands.

16 - Do not excessively bend, twist, pull or damage the power cord.

17 - Avoid placing this product where the humidity spout is pointed directly at an object or

18 - Do not inhale the mist/vapor expelled from the product or drink water from the tank.

19 - Do not ll the water tank with hot or boiling water.13

20 - Do not use this product in direct sunlight or near a heat source such as a stove, heater

21 - If the water tank becomes cracked or damaged, do not use.

22 - Do not keep this product running for an extended period of time.

23 - Unplug the cord when unit is not in use for an extended period of time and/or when no

24 - Do not keep water in the tank when not in use for an extended period of time.

25 - Do not clean the unit, water tank or water reservoir with detergents or chemicals of any

26 - The use of water additives including ethereal/essential oils, fragrances, eucalyptus, water

conditioners, etc. will damage the appliance materials and as a consequence the whole unit. Any use of such additives will void the manufactures warranty.

27 - Do not use this product near any other electronic device.

28 - Do not cover the spray spout at any time during use. Do not put anything on or in the

29 - When unplugging from outlet hold humidier securely.

30 - Do not place cord over objects.

31 - Do not get water in or on the power cord or where it connects to the product.

32 - Do not use near a sink.

33 - Do not touch the water tank during operation.

34 - Do not submerse the unit in water or pour water on the unit or in the humidity spout.

35 - When emptying water from water tank, pour on drain side.

36 - Do not cover the spout with cloth or hand and do not use without the spout.

37 - Use clean or distilled water in tank. Hard water areas will require more frequent cleaning.

38 - If moisture forms on the walls or windows of the room, turn off the humidier.

The room already has plenty of humidity and additional moisture may cause damage.14 ENGLISH

1 - MAIN FEATURES AND FUNCTIONING

2 emission levels. Warm/cool mist. Transparent water tank to ensure the water level is visible. Night light can be controlled on/off. Misting nozzle rotates 360 degrees. Unit automatically switches off when the water is empty.

FOR HOUSEHOLD USE ONLY

Control panel Base Transducer Water tank cap Water tank Mist outlet15 ENGLISH AQUA PURE

2 - PRE-OPERATING INSTRUCTION

Select a rm, level, at location at least 15cm from any wall or object for proper air ow. Place the humidier on a water-resistant surface, as water can damage furnitu- re and some ooring. Do not place unit directly on carpet, towels, blankets or other absorbent surfaces. We will not accept responsibility for damage caused by water spillage. FILLING Make sure unit is unplugged.

1. Separate the tank from the

2. Flip over water tank and open

the tank lid, turning it to the left.

3. Pour cool, clean water directly

into the tank. Do not pour anything but water into the tank.

4. Close the tank lid, turning it to

the right. It is important to FIRMLY secure cap after ling the tank with water.

5. Attach tank to base of unit.

6. Before turning ON the humidier make sure there is water in the Bowl.16

Press button A to switch the humidier ON (button lit blue) and OFF (button lit white). B) Hot/cool mist Press button B to select hot (button lit blue) or cool mist (button lit white). C) Mist emission setting Press button C to adjust the emission level up or down. A low mist emission level is recom- mended at night-time. D) Night light Press button D to switch the night light on or off.17 ENGLISH AQUA PURE

4 - DAILY MAINTENANCE

Before clearing, turn off the power and unplug the appliance from the electrical outlet. Lift off the tank of the humidier from the housing. Carry the water tank and the housing to a sink, drain all the remaining water. Drain and rinse water tank and housing to remove any sediment and dirt. Wipe clean and dry with clean soft cloth or paper towel. Rell the water tank with cool tap water as instructed in lling water tank paragraph. It is necessary to remove daily any residual water, from both the tank and the tank and the bowl, then clean and dry both and nally rell with new and clean tap water.

Always unplug the unit before servicing in any way. GENERAL CLEANING

  • Inside the bowl. Pour excess water out of the unit. Wash out the unit with fresh water using the cleaning brush and a soft cloth as needed. Do not submerse the base of the unit into water, or allow water to enter inside the dry air exhaust port of the unit.
  • Water tank. Empty water tank. Remove mist nozzle and clean the mist tube with fresh water and a light brush (bottle cleaning brush is recommended).
  • Outer surface of the unit. Wipe the surface of the unit with a soft, damp cloth if needed. If you notice an accumulation of water during usage, reduce humidity and dry outer surface with a cloth.
  • Ultrasonic Transducer. If you use the hard water, distilled or tap water, you should clean the transducer weekly.18 ENGLISH DESCALING
  • Depending on usage and water type, cleaning to remove scale may be required weekly or every other week to optimize unit performance.
  • If you live in a hard water area, we recommend the use of distilled water or soften water for your humidier. This will help reduce the precipitation of minerals or ‘white dust’.
  • Do not clean the unit or water tank with detergents or cleaning chemicals of any kind. ULTRASONIC DISK

2. Remove the tank and empty all water from unit bowl and tank.

3. Locate the ultrasonic disk on the inside center of the base unit.

4. Use ONLY the enclosed cleaning brush to gently clean disk and remove build up and

deposits. Do not scrub or scrape the ultrasonic disk. *Clean the disk with the brush only. No other cleaning tool should be used. BRUSH ONLY. Ultrasonic Disk19 ENGLISH AQUA PURE If scale becomes difcult to remove with brush:

1. Fill the bowl with mixture of 1 tea spoon of white vinegar and 1 tea spoon of water

2. Let solution stand for 5 minutes.

3. With the vinegar in the bowl, clean all interior surfaces with a soft cloth or brush to help

4. Also check mist nozzle and mist tube in water tank. Clean as needed.

5. Rinse the Base thoroughly with water to remove scale and vinegar solution.

6 - END OF SEASON STORAGE

  • Follow the Cleaning and Descaling instructions when the humidier will be stored at the end of the season.
  • Dry the humidier completely before storing. DO NOT store with water inside the bowl or Water Tank.
  • Pack the unit in its original carton and store in a cool, dry location. NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.20 ENGLISH PROBLEM SOLUTION Water vapor and humidity are not produced. Power plug: Unplug and then try again. Power Failure: When the power is returned, try again. Tank Installation: Make sure the tank is correctly attached. The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. Air blows but water vapor is not produced. Excessive Water: Remove a certain amount of water from the tank. Detergent residue and/or oil ingredients from cosmetics, etc may be in tank; wash out tank and try again. The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. If you use hard water, replace with softer water. Humidity level is low. The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. The water in the unit is too cold: Replace with cool, but not cold water. The humidity has a bad smell. Poor maintenance or dirty water: Clean the product thoroughly, and ll it with fresh water. White dust is forming on nearby furniture. Hard water may deposit a certain of dust. Dust in the air also settles because of added humidity in the room. Use distilled water if this becomes a nuisance. Unit has stopped working. No or low water. Unplug unit and rell tank. Water is accumulating outside of unit or area surrounding unit. Saturation of humidity. Lower mist control setting. Unit not level and water is accumulating. Unplug and place on level surface. Point spray away from objects. Raise unit on a water-resistant level surface at least 60 cm from the oor. Water dripping when relling. Water remaining on bottom of tank. Wipe tank or tilt to drain before transporting. Increased noise level. Unit must be placed on a at, level, hard surface. Make sure it is NOT placed on a soft or absorbent surface. Flashing light symbols. Indicates low water. Unplug and rell tank.