USER MANUAL Alpha Sunzi ROBLIN

FITTING THE APPLIANCE

Thank you for buying a ROBLIN product which has been manufactured to the highest quality standards to meet your requirements. We recommend you carefully read this booklet in which you will nd instructions for installation, hints for use and maintenance. The Instructions for Use apply to several versions of this appliance. Accordingly, you may nd descrip- tions of individual features that do not apply to your specic appliance. 1 ELECTRICAL

  • This cooker hood is tted with a 3-core mains cable with a standard 10/16A earthed plug.
  • Alternatively the hood can be connected to the mains supply via a double-pole switch having 3mm minimum contact gap on each pole.
  • Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood.
  • Technical Specication: Voltage 220-240 V, single phase ~ 50 Hz / 220 V - 60Hz. 2 INSTALLATION ADVICE
  • Ensure the cooker hood is tted in compliance with the recommended xing heights.
  • To ensure the safe operation of this cooker hood, we recommend that the hood should not be tted below 65cm (for electric) or (70cm for gas) the measurements taken from the surface of the cooking appliance to the underside of the cooker hood.
  • It is a possible re risk if the hood is not sited as recommended.
  • To ensure the best results, the cooking fumes should be able to rise naturally towards the inlet grilles on the underside of the cooker hood and the cooker hood should be positioned away from doors and windows, which will create turbulence.
  • If the room where the hood is to be used contains a fuel-burning appliance such as a central heating boiler then its ue must be of the room sealed or balanced ue type.
  • If other types of ue or appliances are tted ensure that there is an adequate supply of fresh air to the room. Ensure the kitchen is tted with an airbrick, which should have a cross-sectional measurement equivalent to the diameter of the ducting being tted, if not larger.
  • The ducting system for this cooker hood must not be connected to any existing ventilation system, which is being used for any other purposes or to a mechanically controlled ventilation ducting.
  • The ducting used must be made from re retardant materials and the correct diameter must be used, as incorrect sized ducting will affect the performance of this cooker hood.
  • When the cooker hood is used in conjunction with other appliances supplied with energy other than electricity, the negative pressure in the room must not exceed 0.04 mbar to prevent the fumes from combustion being drawn back into the room.
  • The appliance is for domestic use only and should not be operated by children or people who are inrm without supervision.
  • This appliance must be positioned so that the wall socket is accessible.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 3 FITTING Any permanent electrical installation must comply with the latest regulations concerning this type of instal- lation and a qualied electrician must carry out the work. Non-compliance could cause serious accidents or injury and would deem the manufacturers guarantee null and void. IMPORTANT - The wires in this mains lead are coloured in accordance with the following code : green / yellow : earth blue : neutral brown : live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.6

- The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow. - The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. - The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. ATTENTION: Do not forget to use adequate plugs to the support brackets. Enquire after the manu- facturers. Do an embedding if necessary. The manufacturer accepts no responsibility in case of a faulty hanging due to the drilling and the setting up of plugs. The extractor unit is tted into the base board of the cooker hood (thickness: 12 to 22 mm). (Fig 1) Connect the electrical plug and set the extractor tube in place. Fit the appliance into the cutout and x it with the 4 screws supplied. The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker hood is ducted to the outside, charcoal lters are not required.The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from re retardant material, produced to BS.476 or DIN 4102-B1. Wherever possible use rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. Maximum length of ducting run: - 4 metres with 1 x 90° bend. - 3 metres with 2 x 90° bends. - 2 metres with 3 x 90° bends. The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood.

  • RECYCLING : The air is recirculated into the kitchen through the opening located on the upper side of the cabinet or of the hood (Fig. 2). Install the charcoal lters inside the canopy (Fig 3).7
  • To obtain the best performance we recommend you to switch ‘ON’ the cooker hood a few minutes (in the boost setting) before you start cooking and you should leave it running for approximately 15 minutes after nishing.
  • IMPORTANT: NEVER DO FLAMBÉ COOKING UNDER THIS COOKER HOOD
  • Do not leave frying pans unattended during use as over-heated fat and oil might catch re.
  • Do not leave naked ames under this cooker hood.
  • Switch ‘OFF’ the electric and gas before removing pots and pans.
  • Ensure heating areas on your hotplate are covered with pots and pans when using the hotplate and cooker hood simultaneously. Control panel

BUTTON LED FUNCTIONS

T1 Speed On Turns the Motor on at Speed one. Turns the Motor off. T2 Speed On Turns the Motor on at Speed two. T3 Speed Fixed When pressed briefly, turns the Motor on at Speed three. Flashing Pressed for 2 Seconds. Activates Speed four with a timer set to 10 minutes, after which it returns to the speed that was set previously. Suitable to deal with maximum levels of cooking fumes. L Light Turns the Lighting System on and off.

Warning: Button T1 turns the motor off, after first passing to speed one.8

6 MAINTENANCE Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply. The cooker hood must be kept clean; a build up of fat or grease may cause a re hazard. Casing

  • Wipe the cooker hood frequently with a clean cloth, which has been immersed in warm water contain- ing a mild detergent and wrung out.
  • Never use excessive amounts of water when cleaning particularly around the control panel.
  • Never use scouring pads or abrasive cleaners.
  • Always wear protective gloves when cleaning the cooker hood. Metal Grease Filters : The metal grease lters absorb grease and dust during cooking in order to keep clean the cooker hood inside. The grease lters should be cleaned once a month or more frequently if the hood is used for more than 3 hours per day. To remove and replace the metal grease lters
  • Remove the metal grease lters one at a time by releasing the catches on the lters; the lters can now be removed.
  • The metal grease lters should be washed, by hand, in mild soapy water or in a dishwasher.
  • Allow to dry before replacing. Active Charcoal Filter : The charcoal lter cannot be cleaned. The lter should be replaced at least every three months or more frequently if the hood is used for more than three hours per day. To remove and replace the lter
  • Remove the metal grease lters.
  • Press against the two retaining clips, which hold the charcoal lter in place and this will allow the lter to drop down and be removed.
  • Clean the surrounding area and metal grease lters as directed above.
  • Insert the replacement lter and ensure the two retaining clips are correctly located.
  • Replace the metal grease lters. Extraction tube : Check every 6 months that the dirty air is being extracted correctly. Comply with local rules and regulations with regard to the extraction of ventilated air. Lighting : If the lamp fails to function check to ensure it is tted correctly into the holder. If lamp failure has occurred then it should be replaced with identical replacement. Do not replace with any other type of lamp and do not t a lamp with a higher rating.

7 GUARANTEE AND AFTER SALES SERVICE

  • In the event of any malfunction or anomaly, notify your tter who will have to check the ap- pliance and its connection.
  • In the event of damage to the mains supply cable, this can only be replaced by at approved repair centre appointed by the manufacturer who will have the required tools and equipment to carry out any repairs properly. Repairs carried out by other persons will invalidate the guarantee.
  • Use only genuine spare parts. Should these warnings fail to be observed it could affect the safety of your cooker hood.
  • When ordering spare parts quote the model number and serial number written on the rating plate, which is found on the casing behind the grease lters inside the hood.
  • Proof of purchase will be required when requesting service. Therefore, please have your receipt available when requesting service as this constitutes the date from which your guarantee commenced. This Guarantee does not cover : - Damage or calls resulting from transportation, improper use or neglect, the replacement of any light bulbs or lters or removable parts of glass or plastic. These items are considered to be consumable under the terms of this guarantee. GB9 8 REMARKS This appliance complies with European regulations on low voltages Directive 2006/95/CE on electrical safety, and with the following European regulations: Directive 2004/108/CE on electromagnetic compat- ibility and Directive 93/68 on EC marking. When this crossed-out wheeled bin symbol is attached to a product it means the product is cov- ered by the European directive 2002/96/EC.Your product is designed and manufactured with high quality materials and components, which can be recycled and reused.Please inform yourself about the local separate collection system for electrical and electronic product. Please act according to your local rules and do not dispose of your old products with your normal household waste. The correct disposal of your old product will help prevent potential negative consequences for the environment and human health. GBA1

ELECTRICAL REQUIREMENTS Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations . For your own safety this should be undertaken by a qu alified electrician e.g. your local Electricity Board, or a contractor who is on the roll of the National Insp ection Council for Electrical Installation Contr acting (NICEIC). ELECTRICAL CONNECTION Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate insi de the cooker hood. This appliance is fitted with a 2 core mains cable and must be permanent ly connected to the electricity supply via a double-pole switch having 3mm minimum contact gap on each pole. A Switched Fuse Connection Unit to BS.1363 Part 4 , fitted with a 3 Amp fuse, is a recommended mains supply connection accessory to ensure compliance with the Safety Requirements applicable to fixe d wiring instructions. The wires in this mains lead are coloured in accordance with th

following code: Blue N eutral Brown Live As the colours of the wires in the mains lead of this appliance may not

entifying the te rminals in your connection u nit, proceed as follow s:- The wire which is coloured blue must be connected to the terminal w hich is marked with the letter ‘N’ or coloured black. The wire which is coloured brown must be connected to the terminal w hich is marked with the letter ‘L’ or coloured red.