USER MANUAL CS12AF LG

OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating

your set and retain it for future reference.

OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating

your set and retain it for future reference. P/NO : 5400826601 Rev.: www.lge.com

TYPE : WALL MOUNTED ENGLISHITALIANOESPAÑOL FRANCAIS DEUTSCHΕΛΛΗΝΙΚΆPORTUGUESENEDERLANDSPOLSKIMAGYAR2 Air Conditioner

Air Conditioner Owner’s Manual

TABLE OF CONTENTS FOR YOUR RECORDS Write the model and serial numbers here:

You can find them on a label on the side of each unit.

■ Staple your receipt to this page in the event you need

it to prove date of purchase or for warranty issues.

READ THIS MANUAL Inside you will find many helpful hints on how to use

and maintain your air conditioner properly. Just a little

preventive care on your part can save you a great deal

of time and money over the life of your air conditioner.

You'll find many answers to common problems in the

chart of troubleshooting tips. If you review our chart of

Troubleshooting Tips first, you may not need to call

• Contact the authorized service technician for

repair or maintenance of this unit.

• Contact the installer for installation of this unit.

• The air conditioner is not intended for use by

young children or invalids without supervision.

• Young children should be supervised to ensure

that they do not play with the air conditioner.

• When the power cord is to be replaced,

replacement work shall be performed by

authorized personnel only using only genuine

A. Safety Precautions3

B. Electrical Safety6

Temporary Use of an Adapter6

Temporary Use of an Extension Cord...6

Symbols used in this Manual6

C. Product Introduction7

Operation Indication Lamps 7

Self-Diagnosis Function 7

D. Operating Instructions8

How to insert the Batteries 8

Wireless Remote Controller

Healthy Dehumidification Operation....11

Auto Operation (Optional)11

Auto Changeover Operation

Jet Cool/Heat Operation12

Energy-Saving Cooling Mode

Setting the Current Time 14

Vertical / Horizontal Airflow

Air Circulation Mode15

Wired Remote Controller (Accessory)

Troubleshooting Tips!

Save time and money!19

Call the service immediately in the

following situations 19Owner's Manual 3

To prevent injury to the user or other people and property damage, the following instructions must be followed.

■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by

the following indications.

■ Meanings of symbols used in this manual are as shown below.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage.

Be sure to follow the instruction.

Always use a power plug and socket with

• There is a risk of electrical shock.

Do not use a defective or underrated

circuit breaker. Use the correctly rated

• There is a risk of electrical shock .

Do not use a multi consent. Always use

this appliance on a dedicated cicuit and

• Otherwise it can cause an electrical shock or

For electrical work, contact the dealer, seller,

a qualified electrician, or an Authorized

Service Center. Do not disassemble or repair

the product by yourself.

• There is a risk of fire or electrical shock.

Always ground the product as per the

wiring diagram. Do not connect the

ground wire to gas or water pipes

lightening rod or telephone ground wire.

• There is a risk of fire or electrical shock.

Install the panel and the cover of control

• There is a risk of fire or electrical shock due

to dust , water etc.

Use the correctly rated breaker or fuse.

• There is a risk of fire or electrical shock.

Do not modify or extend the power cable.

If the power cable or cord has scrathes or

skin peeled off or deteriorated then it

• There is a risk of fire or electrical shock.

For installation, removal or reinstall ,

always contact the dealer or an

Authorized Service Center.

• There is a risk of fire, electrical shock.,

explosion, or injury.

Do not install the product on a defective

installation stand. Be sure that the

installation area does not deteriorate with

• It may cause the product to fall.

Never install the outdoor unit on a

moving base or a place from where it

• The falling outdoor unit can cause damage or

injury or even death of a person.

When the product is soaked (flooded or

submerged) in water , contact an

Authorized Service Center for repair

before using it again.

• There is a risk of fire or electrical shock.

In outdoor unit the step-up capacitor

supplies high voltage electricity to the

electrical components. Be sure to

discharge the capacitor completely

before conducting the repair work.

• An charged capacitor can cause an electrical

When installing the unit, use the

installation kit provided with the product.

• Otherwise the unit may fall and cause severe

Be sure to use only those parts which

are listed in the svc parts list. Never

attempt to modify the equipment.

• The use of inappropriate parts can cause an

electrical shock, excessive heat generation or

Indoor/outdoor wiring connections must

be secured tightly and the cable should

be routed properly so that there is no

force pulling the cable from the

connection terminals.

• Improper or loose connections can cause

heat generation or fire.

Safely dispose off the packing materials.

Like screws, nails, batteries, broken

things etc after installation or svc and

then tear away and thraw away the plastic

• Children may play with them and cause

Make sure to check that the power cable

plug is not dirty, loose or broken and

then only insert the plug completely.

• Dirty, loose or broken power plug can

cause an electrical shock or fire.

Be sure to check the refrigerant to the

used. Please read the label on the product.

• Incorrect refrigerant used can prevent the

normal operation of the unit.

Don't use a power cord, a plug or a loose

socket which is damaged.

• Otherwise it may cause a fire or electrical

Do not touch , operate, or repair the

product with wet hands. Hold the plug by

hand when taking out

• There is a risk of electrical shock or fire.

Do not place a heater or other heating

appliances near the power cable.

• There is a risk of fire or electrical shock.

Do not allow water to run into electric

parts. Install the unit away from water

• There is a risk of fire, failure of the product, or

Do not store or use or even allow

flammable gas or combustibles near the

• There is a risk of fire.

Do not use the product in a tightly closed

space for a long time. Perform ventilation

• Oxygen deficiency could occur and hence

Do not open the front grille of the product

during operation. (Do not touch the

electrostatic filter, if the unit is so equipped.)

• There is a risk of physical injury, electrical

shock, or product failure.

If strange sounds, smell or smoke comes

from product.Immediately turn the breaker

off or disconnect the power supply cable.

• There is a risk of electrical shock or fire.

Ventilate the product room from time to

time when operating it together with a

stove, or heating element etc.

• Oxygen deficiency can occur and hence harm

Turn the main power off and unplug the

unit when cleaning or repairing the

• There is a risk of electrical shock.

When the product is not to be used for a

long time, disconnect the power supply

plug or turn off the breaker.

• There is a risk of product damage or failure,

or unintended operation.

Take care to ensure that nobody

especially kids could step on or fall onto

• This could result in personal injury and

Take care to ensure that power cable

could not be pulled out or damaged

• There is a risk of fire or electrical shock.

Do not place ANYTHING on the power

• There is a risk of fire or electrical shock.

Do not plug or unplug the power supply plug to turn the unit

• There is a risk of fire or electrical shock.

When flammable gas leaks, turn off the gas and open a window

for ventilation before turn the product on.

• Do not use the telephone or turn switches on or off. There is a risk of

Two or more people must lift and

transport the product.

• Avoid personal injury.

Do not install the product where it will be

exposed to sea wind (salt spray) directly.

• It may cause corrosion on the product.

Install the drain hose to ensure that the

condensed water is drained away properly.

• A bad connection may cause water leakage.

Keep level even when installing the

• To avoid vibration or noise.

Do not install the product where the noise

or hot air from the outdoor unit could

damage or disturb the neighborhoods.

• It may cause a problem for your neighbors

Always check for gas (refrigerant)

leakage after installation or repair of

• Low refrigerant levels may cause failure of

product.Owner's Manual 5

Do not use the product for special purposes,

such as preserving foods, works of art, etc. It

is a consumer air conditioner, not a precision

refrigeration system.

• There is a risk of damage or loss of property.

Do not block the inlet or outlet of air flow.

• It may cause product failure.

Use a soft cloth to clean. Do not use

harsh detergents, solvents or splashing

• There is a risk of fire, electrical shock, or

damage to the plastic parts of the product.

Do not touch the metal parts of the

product when removing the air filter.

• There is a risk of personal injury.

Do not step on or put anyting on the

product. (outdoor units)

• There is a risk of personal injury and failure of

Always insert the filter securely after

cleaning. Clean the filter every two weeks

or more often if necessary.

• A dirty filter reduces the efficiency.

Do not insert hands or other objects

through the air inlet or outlet while the

product is operating.

• There are sharp and moving parts that could

cause personal injury.

Be cautious when unpacking and

installing the product.

• Sharp edges could cause injury.

If the refrigerant gas leaks during the

repair, do not touch the leakaing

• The refrigernat gas can cause frostbite (cold

Do not tilt the unit when removing or

• The condensed water inside can spill .

Do not mix air or gas other than the

specified refrigerant used in the system .

• If air enters the refrigerant system, an

excessively high pressure results, causing

equipment damage or injury.

If the refrigerant gas leaks during the

installation, ventilate the area immediately.

• Otherwise it can be harmfull for your health.

Dismantling the unit, treatment of the

refrigerant oil and eventual parts should

be done in accordance with local and

Replace the all batteries in the remote

control with new ones of the same type.

Do not mix old and new batteries or

different types of batteries.

• There is a risk of fire or product failure.

Do not recharge or disassemble the

batteries. Do not dispose off batteries in

• They may burn or explode.

If the liquid from the batteries gets onto

your skin or clothes, wash it well with

clean water. Do not use the remote if the

batteries have leaked.

• The chemicals in batteries could cause burns

or other health hazards.

If you eat the liquid from the batteries,

brush your teeth and see doctor. Do not

use the remote if the batteries have

• The chemicals in batteries could cause

burns or other health hazards.

Do not let the air conditioner run for a

long time when the humidity is very high

and a door or a window is left open.

• Moisture may condense and wet or damage

Do not expose your skin or kids or

plants to the cool or hot air draft.

• This could harm to your health.

Do not drink the water drained from the

• It is not sanitary and could cause serious

Use a firm stool or ladder when cleaning,

maintaining or repairing the product at

• Be careful and avoid personal injury.

ENGLISH6 Air Conditioner

Electrical Safety • This appliance must be properly grounded.To minimize the risk of an electrical shock, you must always plug into a grounded outlet.• Do not cut or remove the grounded prong from the power plug. • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the applianceunless the cover screw is metal and not insulated, and the wall receptacle is grounded through thehouse wiring.• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle andcircuit checked by a qualified electrician.We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections,use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in theadapter is aligned with the large slot in the receptacle for a proper polarity connection.To disconnect the power cord from the adapter, use one hand on each to avoid damaging the groundterminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.• Never use the appliance with a broken adapter. We strongly discourage the use of an extension cord due to potential safety hazards. Temporary Use of an Adapter

Temporary Use of an Extension Cord

This symbol alerts you to the risk of an electrical shock.

This symbol alerts you to hazards that may cause harm to the

This symbol indicates special notes.

NOTE Symbols used in this Manual

This appliance should be installed in accordance with national wiring regulations. This guide acts as aguide to help to explain product features.ENGLISH Owner's Manual 7

Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your

The display will be activated for 10 seconds during STARTing operaion or by pressing any button on the

remote controller. After 10 seconds, display retains about 50% luminosity.

• Blue lamp : during Cooling, Dehumidification, Auto Operation cooling, Auto Changeover cooling, Air

circulation Operation. Error code (1 digits)

• Red lamp : during Heating, Auto Operation heating, Auto Changeover heating .

Error code (10 digits)

Error Indicator : lights up Blue lamp and red lamp alternately

Operation Indication Lamps

Self-Diagnosis Function

Error code Description

05 Communcation error between in and out

ENGLISH8 Air Conditioner

Operating Instructions

How to insert the Batteries

Wireless Remote Controller Maintenance

1. Remove the battery cover by pulling it according to the arrow

2. Insert new batteries making sure that the (+) and (-) of battery are

installed correctly.

3. Reattach the cover by sliding it back into position.

1. Always use/replace both batteries of same type.

2. If the system is not to be used for a long time, remove the

batteries to save their working life.

3. If the display screen of remote controller starts fading, replace

both of the batteries.

Choose a suitable place where its safe & easy to reach.

2. Fix the holder to wall etc with the supplied

3. Slide the remote controller inside the holder.

1. Remote controller should never be exposed to

2. Signal transmitter & receiver should always be

clean for proper communication. Use a soft

cloth to clean them.

3. In case some other appliances also get

operated with remote control, change their

position or consult your serviceman.

1. The signal receiver is inside the unit.

Aim the remote controller towards the unit to operate it.

There should not be any blockage in between.

NOTE Operating Instructions

6 Cooling OperationAuto Operation or Auto ChangeoverHealthy Dehumidification OperationFlip-up door(opened)Heating Operation Signal transmitter

The controls will look like the following.

Wireless Remote Controller

1. START/STOP BUTTON Used to turn off/on the unit.

low, medium, high and CHAOS.

6. CHAOS SWING BUTTON Used to stop or start louver movement and set the

desired up/down airflow direction.

7. ON/OFF TIMER BUTTONS Used to set the time of starting and stopping

8. TIME SETTING BUTTONS Used to adjust the time.

9. TIMER SET/CANCEL BUTTON Used to set and to cancel the timer operation.

10. SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation.

11. AIR CIRCULATION BUTTON(OPTIONAL)

Used to circulate the room air without cooling or heating.

ENERGY-SAVING COOLING MODE BUTTON

(OPTIONAL) For inverter type models

12. ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature.

13. PLASMA BUTTON(OPTIONAL)

Used to start or stop the plasma-purification function.

14. HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (OPTIONAL)

Used to set the desired horizontal airflow direction.

15. RESET BUTTON Used prior to resetting time.

16. 2nd F BUTTON Used prior to using modes printed in blue at the

bottom of buttons. 17. AUTO CLEAN BUTTON(OPTIONAL)Used to set auto clean mode.In some models this button has a 2nd function of LEDluminosity control.18. HEATER BUTTON(OPTIONAL)(Not available in all models)19. LCD LUMINOSITY BUTTON(OPTIONAL)Used to adjust LCD luminosity.To use the functions printed in blue at the bottom of the buttons press 2 nd F button first and then the required functionbutton. Pressing the 2 nd F button activates the blue printed function of the respective button. To cancel the functionpress the 2nd F button again else it will automatically cancel if remains idle after 10 seconds.

NOTE JET COOL/JET HEAT BUTTON Used to start or stop the speed cooling

The Jet Cool/Jet Heat operates

(Heat pump model only)

To lower the temperature

To raise the temperature

4 Fan speed is on low. Fan speed is on medium. Fan speed is on high.CHAOS Air

Operating Instructions

Press the START/STOP BUTTON to

The unit will respond with a beep.

Open the door of the remote controller and press the

operation mode button. Each time the button is pressed, the

operation mode is shifted in the direction of the arrow.

For cooling or heating operation set the desired indoor

temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS.

For cooling the temperature can be set within 18°C~30°C and

for heating the temperature range is 16°C~30°C.

Set the fan speed with the remote controller. You can select the fan speed in four steps-low,

medium, high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON.

Each time the button is pressed, the fan speed mode is shifted.

Natural wind by the CHAOS logic

For fresher feeling, press the INDOOR FAN SPEED SELECTOR BUTTON selector and set to CHAOS mode.

In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.

Operation ModeOwner's Manual 11

ENGLISH During Healthy Dehumidification Operation

❏ If you select the dehumidification mode on the OPERATION MODE SELECTION BUTTON, the product starts to run the dehumidification

function. It automatically sets the room temperature and airflow volume to

the best condition for dehumidification, based on the sensed current room

In this case, however, the setting temperature is not displayed on the remote

controller and you are not able to control the room temperature either.

❏ During the healthy dehumidification function, the airflow volume is

automatically set according to the optimization algorithm responding to the

current room temperature status, so that the room condition is kept healthy

and comfortable even in the very humid season.

Auto operation basically is heating or cooling function of the air

But during this operation the controller changes the operation mode

automatically to keep the temperature within ±2°C with respect to the

setting temperature.

Operating Instructions

In this operation the actual operating mode is automatically set by the

electronic control logic based on the current room temperature or other

connected indoor unit. If you feel hot or cold, you can set the temperature

or fan speed for more cooling or heating effect.

Setting Temp. Range : 18~30°C To run the healthy dehumidification mode follow steps 1, and 2 and 4

(See operation mode)

To run the auto operation follow steps 1, and 2. (See operation mode)

To run this operation follow steps 1, 2, 3, and 4. (See operation mode)

Auto Operation (Optional)

Auto Changeover Operation (Optional)

Healthy Dehumidification Operation

ENGLISH12 Air Conditioner

Operating Instructions

Jet Cool/Heat Operation

❏ During Auto Clean function, you can use only START/STOP BUTTON, PLASMA BUTTON and AUTO CLEAN BUTTON.

Auto Clean function remove moisture in indoor units after cooling operation(cooling, healthy dehumidification,

auto operation cooling, auto changeover cooling)

1. Press the AUTO CLEAN BUTTON to activate this function.

2. Now whenever the unit is turned off, the indoor fan is still running for about 30

minutes internally without cooling or dehumidification operation. Also the louver is

3. This dries up any remains of moisture & cleans the unit internally.

4. If you press AUTO CLEAN BUTTON again during operation, this function is

Jet Cool function can be used to cool the room quickly in hot summer. When this

function is turned on, the air conditioner runs in cooling operation mode with super

high fan speed and 18°C setting temperature for 30 minutes for fast and effective

Similarly,Jet Heat function (available only in some models) warms up the room quickly

by operating at super high fan speed and 30°C setting temperature for 30 minutes.

You can activate this operation by pressing the JET COOL/HEAT BUTTON.

To change from Jet Cool mode to high fan speed cooling mode, press the JET COOL/HEAT BUTTON or

INDOOR FAN SPEED SELECTOR BUTTON or the ROOM TEMPERATURE SETTING BUTTON again.

• Jet Cool/Heat operation cannot be activated during Air Circulation operation, Auto operation and Auto

changeover operation.

• Jet Heat operation cannot be activated when wired remote controller is connected.

• You can use Jet Heat function by pressing JET COOL/HEAT BUTTON in heating operation.

NOTEOwner's Manual 13

Energy-Saving Cooling Mode (Optional)

Operating Instructions

Energy-saving cooling mode can save energy in cooling and healthy dehumidification operation, because it

can operate efficiently by setting body-adaptation time according to the change of time and temperature and

adjusting automatically desired temperature.

1. Press the START/STOP BUTTON to start the unit.

2. Open the door on the remote controller.

Select cooling operation or healthy dehumidification operation.

3. Press the ENERGY-SAVING COOLING MODE BUTTON.

4. To cancel the energy-saving cooling mode, press the ENERGY-SAVING COOLING MODEL BUTTON again and unit will operate in previous

mode(Cooling or healty dehumidification mode).

Operation procedures when the remote control can't be used.

The operation will be started if the ON/OFF button is pressed.

If you want to stop operation, re-press the button.

Display Luminosity (Optional)

The Display Luminosity can be adjusted by using the remote control.

Press the start/stop button to start the unit. Open the door on the remote control, press the 2ndF button

and, press display luminosity button.

Display will be dark. Press the button again to set bright display.

Room Temp. ≥ 24°C 21°C ≤ Room Temp. < 24°C Room Temp. < 21°C Operating mode Cooling Cooling Healthy Dehumidification Heating

22°C 22°C 23°C 24°C Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room

temperature and resets in 18 minutes.

During test operation, if remote controller signal is received, the unit operates as remote controller sets.

If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound

If you want to stop the operation, re-press the button.

ENGLISH14 Air Conditioner

Operating Instructions

Delay off timer Delay on timer Delay off and on timer Delay on and off timer

1. Press the SLEEP MODE AUTO BUTTON to set the time when you want the unit to stop automatically.

2. The timer is programmed in one-hour increments by pressing the SLEEP MODE AUTO BUTTON 1 to 7 times.

The sleep mode is available for 1 to 7 times.

To alter the time period in steps of 1 hour, press the SLEEP MODE AUTO BUTTON while aiming at air conditioner.

• The sleep mode will operate indoor fan at slow speed in cooling mode and at low speed in heating mode for

In cooling mode or healthy dehumidification mode:

The setting temperature will rise automatically two times by 1°C over next consecutive 30 minutes (2°C in 1 hour) for a

comfortable sleep. Now this will be the final setting temperature as long as sleep mode is functioning.

The setting temperature will drop automatically two times by 1°C over next consecutive 60 minutes for a comfortable

sleep. Now this will be the final setting temperature as long as sleep mode is functioning.

1. Time can be set only when you press the RESET BUTTON. Having replacing the batteries,

you should press the RESET BUTTON to reset the time. Press the Start/Stop button.

2. Press 2nd F button and check if icon is on.

3. Press the TIME SETTING BUTTONS until the desired time is set.

4. Press the TIME SET/CANCEL BUTTON.

Check the indicator for A.M. and P.M.

1. Make sure to set current time correctly on the display of the remote controller.

2. Press 2nd F button.

3. Press the ON/OFF TIMER BUTTONS to turn timer on or off.

4. Press the TIME SETTING BUTTONS until the desired time is set.

5. To set the selected time, press the TIMER SETTING BUTTONS aiming the remote controller at the

To cancel the timer setting

Check if icon is off.

Press the TIMER CANCEL BUTTON aiming the remote controller at the signal receptor.

(The timer lamp on the air conditioner and the display will go off.)

Select one of the following four types of operation.

NOTE ON OFF CANCEL SET CANCEL SET CANCEL SET Sleep Mode

Setting the Current Time

Timer SettingOwner's Manual 15

This operation circulates the air without cooling or heating. It can

be activated by pressing the AIR CIRCULATION BUTTON. Once

the air circulation is activated you can select the air speed by

pressing the INDOOR FAN SPEED SELECTOR BUTTON.

Operating Instructions

Vertical / Horizontal Airflow Direction Control

• By pressing the CHAOS SWING BUTTON the horizontal air flow direction is changed automatically based on the chaos

algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if

enjoying natural breeze.

• Always use the remote controller to adjust the up and down air flow direction. Manually moving the vertical air flow

direction louver by hand could damage the mechanism.When the unit is shut off, the up/down airflow direction louver will

close the air outlet vent of the system.

NOTE CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically

changed from high to low or vice versa, depending on the ambient temperature.

NOTE This feature is enabled by factory default setting, but you can disable it

by pressing the ON/OFF button for 6 seconds. The display will

double-blink 3~4 times. To enable it, press the button again for 6

seconds. The display will blink 3~4 times.

NOTE Air Circulation Mode

This function is useful in the situation of power failure. When power regains after a failure this feature restore

the previous operating condition and the air conditioner will run in the same settings.

Auto Restart Function

The up/down airflow (Vertical airflow) can be

adjusted by using the remote controller.

1. Press the START/STOP BUTTON to start the

4. To stop the louver at a desired

The left/right(Horizontal airflow) can be adjusted

by using the remote control.

1. Press the START/STOP BUTTON to start the

4. To stop the louvers at a desired

direction by manually moving the

horizontal airflow direction louver

by hand. At this time, be careful

not to touch the fan with hands.

ENGLISH16 Air Conditioner

OPERATION INDICATION SCREEN SET TEMPERATURE BUTTON FAN SPEED BUTTON ON/OFF BUTTON OPRATION MODE SELECTION BUTTON WIRELESS REMOTE CONTROLLER RECEIVER

• Some products don't receive the

Please attach the inform label inside of the door.

Please choose proper language depend on your

❊ Some functions may not be operated and displayed depending on the product type.

❊ Read Remote Controller's Owner's manual for detail operation method.

Wired Remote Controller (Accessory)Owner's Manual 17

Maintenance and Service

Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and

unplug the power cord.

Clean the unit with a soft dry cloth. Do not use bleach or abrasives.

Never use any of these

• Water hotter than 40°C. It may cause deformation and discoloration.

• Volatile substances. They may damage the surface of the air conditioner.

The air filters behind the front panel / grill should be checked and

cleaned once in every 2 weeks or more often if necessary. To

remove the filters see the self explanatory diagrams for each

model type. Clean the filters with a vacuum cleaner or warm

soapy water. If dirt is not easily removed, wash with a solution of

detergent in lukewarm water. Dry well in shade after washing and

reinstall the filters back in place.

Allergy Free Filter + Triple Filter

Remove the Allergy Free Filter + Triple Filter behind the air filter

and expose them in direct sunlight for 2 hours.

And then insert these filters into original position.

Maintenance and Service

Open the front panel as shown.

Then pull the filter tab slightly forward to remove the air filter.

After removing the air filter remove the Allergy Free and Triple filter by slightly pulling forward.

Maintenance and Service

The heat exchanger coils and panel vents of the outdoor unit should be checked regularly.

If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned.

Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.

NOTE Operation Tips!

Do not overcool the room.

This is not good for the health and

Keep blinds or curtains

Do not let direct sunshine enter

the room when the air conditioner

Keep the room temperature

Adjust the vertical and horizontal

airflow direction to ensure a

uniform temperature in the room.

Avoid opening doors and

possible to keep the cool

Clean the air filter

Blockages in the air filter

reduce the airflow and

dehumidifying effects.

Clean at least once every

Since windows are kept

closed, it is a good idea

ventilate the room now

for effective and fast

The unit gives its rated

cooling capacity when the

fan speed is high.Owner's Manual 19

Maintenance and Service

Troubleshooting Tips! Save time and money!

The air conditioner may be operating abnormally when:

■ The air conditioner is

■ The fuse is blown/circuit

■ Airflow is restricted.

■ The air filter is dirty.

The room may have been hot.

■ Cold air is escaping.

Check the temperature settings.

■ There might be any heating

• Make sure the air conditioner plug is

pushed completely into the outlet.

• Check the house fuse/circuit breaker box

When power is restored, wait 3 minutes to

restart the air conditioner to prevent

tripping of the compressor overload.

• If the voltage is unusually very high or low

the circuit breaker will trip.

• Make sure there are no curtains, blinds, or

furniture blocking the front of the air

• Clean the filter at least every 2 weeks.

See the Maintenance and Service section.

• When the air conditioner is first turned on,

you need to allow time for the room to cool

• Check for open furnace floor registers and

• Make sure they are correct.

• Check and remove such source or turn it

off while using the air conditioner.

What To DoPossible Causes

1. Anything abnormal such as burning smell, loud noise etc. happen. Stop the unit and

turn the breaker off. Never try to repair by yourself or restart the system in such cases.

2. Main power cord is too hot or damaged.

3. Error code is generated by self diagnosis.

4. Water leaks from indoor unit even if the humidity is low.

5. Any switch, breaker (safety, earth) or fuse fails to work properly

User must carry routine checkup & cleaning to avoid unit’s poor performance.

In case of special situation, the job must be carried out by service person only.

Call the service immediately in the following situations

ENGLISH20 Air ConditionerMANUALE DELL’UTENTE CLIMATIZZATORE Leggere con attenzione questo manuale prima di usare

Istruzioni per il funzionamento

In this operation mode the actual operating mode is automatically set by the

electronic control logic based on the current room temperature or other

connected indoor unit. If you feel hot or cold, you can set the temperature or fan

speed for more cooling or heating effect.

Setting Temp. Range : 18~30°C Per avviare la modalità di deumidificazione, seguire le operazioni 1, 2 e 4

Please attach the inform label inside of the door.

Please choose proper language depend on your

4. Para parar as persianas no

Mantenha as persianas ou

Wired Remote Controller (Accessory)16

stekker of stopcontact.

Please attach the inform label inside of the door.

Please choose proper language depend on your

Wired Remote Controller (Accessory)

Please attach the inform label inside of the door.

Please choose proper language depend on your

Wired Remote Controller (Accessory)

Please attach the inform label inside of the door.

Please choose proper language depend on your