DAVY MIST - Essential Oil Diffuser LANAFORM - Free user manual and instructions
Find the device manual for free DAVY MIST LANAFORM in PDF.
Download the instructions for your Essential Oil Diffuser in PDF format for free! Find your manual DAVY MIST - LANAFORM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DAVY MIST by LANAFORM.
USER MANUAL DAVY MIST LANAFORM
Davy Mist EN ENGLISH
Introduction Always place the device on a hard, flat, horizontal surface inside your home. Keep it away from walls and heat sources such as stoves, radiators, etc. Caution: 5 · English broken_image The photographs and other images of the product in this manual and on the packaging are as accurate as possible, but do not claim to be a perfect reproduction of the product. warning_amber Please read all instructions before using your humidifier, particularly these essential safety instructions.
Thank you for choosing the Davy Mist diffuser by Lanaform. Thanks to its variable intensity light and 2 diffusion intensities, the Davy Mist essential oil diffuser invites you to relax and enjoy the benefits of aromatherapy. Designed from noble materials (smooth glass and beech wood base), the Davy Mist diffuser offers a modern, sleek design that will easily adapt to all current trends.
6 · English If it is not placed on a horizontal surface, it may not work properly. Check that your mains voltage is the same as that of your appliance. Do not connect or disconnect the plug with wet hands. If the power cable is damaged, it must be replaced by a similar cable available from the supplier or the supplier’s after-sales department. Do not leave the device in the sun for a long period of time. Do not dismantle the device completely. Do not lift the glass cover when the device is on. If you notice a suspicious smell or sound, switch the device off immediately and consult the “Troubleshooting” section of these instructions for use. If the problem persists, have it examined by the supplier or its after-sales department. Do not use essential oils that are not recommended for diffusion. To do this, consult the
7 · English instructions for using the essential oils in these instructions for use. Do not use perfumes or synthetic essences as this may damage the device. Microorganisms that may be present in water or in the environment where the device is used or stored may develop in the water reservoir and be blown into the air, resulting in possible serious health problems if the water is not renewed and the reservoir is not properly cleaned every 3 days. Use only the AC adapter supplied with this device. The supplied adapter should only be used with the device and not for other purposes. Do not wash the entire unit with water and do not immerse it. Consult the cleaning instructions in these instructions for use. Do not use chemicals (such as acids, alkalis, etc.) or corrosive detergents to clean the device. Never scrape the transducer
8 · English with a hard tool and consult the cleaning instructions in this manual. Be sure to never empty the water from the reservoir into the air outlets, as this will damage the diffuser. Empty the water in the opposite direction of the air outlet. For optimal maintenance, use mineral water. Do not fill above the line indicating the maximum water level. Always add water before adding essential oils. Do not use essential oils without diluting them in water. This device is not intended to be used by people, including children, with reduced physical, sensory or mental capabilities, or people with lack of experience or knowledge, unless they are supervised or instructed on the use of the device by a person responsible for their safety. Children should be supervised to make sure they do not play with the device. Never move the device
while it is running. Avoid dropping or hitting the device Unplug the device when filling with water or during maintenance. Never leave water in the reservoir when the product is not in use. Never place anything on the device while it is running. Place the power cord so that no one can trip when the device is in use. Remove the power cord when the product is no longer in use. Use this device only for its intended purpose, as described in these instructions for use. Device components insert_photo1 Mist outlet 07 Transducer Glass cover 08 DC jack socket Internal reservoir cover 09 Beach wood base LED lamp 10 Diffusion and light Water reservoir adjustment button Air outlet 9 · English
Instructions for use Characteristics
Ultrasound diffuser Beach wood base Glass cover 120 ml capacity 2 emission intensities (10-20 ml/hr) & (20-30ml/hr)
Preparation insert_photo2 01 Place the Davy Mist diffuser in the room half an hour before turning it on so that it can adjust to the room temperature. 02 Ensure that it is always placed on a hard, flat and horizontal surface. 03 Make sure the device is clean before starting to use it. 04 Remove the glass cover (1). 05 Then remove the reservoir cover (2). 06 Pour fresh, preferably demineralised water into the reservoir and do not exceed the maximum level (3). 07 Pour 3 or 4 drops of essential oil into the water (4). 08 Replace the reservoir cover then the glass cover (5). 09 Make sure your hands are completely dry when connecting (and even disconnecting) the device (6). 10 The diffuser is now operational. Instructions for use
Press once on the diffusion and light adjustment button (Fig. 1, point 10) to start diffusion. It defaults to the lowest intensity (10-20ml/hr). Press the button a second time to select the high intensity diffusion (20-30ml/hr). Press the button a third time: the mist emission turns off. By default, the light mode is not disabled. To switch off the device completely (diffusion + light), press and hold the diffusion and light adjustment button for two seconds. To start the diffuser again, press the diffusion and light adjustment button (Fig. 1, point 10. The emission intensity is low (10-20ml/hr) and the light intensity is similar to that before turning off.
Turn the light adjustment button (Fig. 1, point 10) clockwise to activate the light and increase the intensity. Turn the light adjustment button (Fig. 1, point 10) anti-clockwise to reduce the light intensity and turn it off. info By default, the light does not turn off when diffusion stops. To turn the light off, turn the light adjustment button (Fig. 1, point 10) in the opposite direction until the 11 · English
light is turned off or hold the diffusion and light adjustment button for two seconds. report_problem Even though there is a safety device that stops the transducer from working, do not leave the device connected when you are not using it. report_problem Additional information on the use of essential oils.
Before using the essential oils, please check the harmful effects that use of these products may have on your health. Always choose quality essential oils: pure and 100% natural and intended for diffusion. Use them with moderation and care. Follow the instructions and warnings indicated on the packaging of the essential oils, in particular ensuring that: Pregnant women and people with epilepsy, asthma or allergies, heart problems or serious conditions must not use essential oils. Essential oils should only be used for periods not exceeding 10 minutes in a baby's room (- 3 years old) and only when the baby is not present in the room. Make sure that children and minors do not play with or use the device. Only a few drops (3 to 4 drops at most) of essential oils are sufficient to ensure the device works properly and the fragrance is diffused. Excessive use of essential oils could damage the device.
First, pour the water into the reservoir before adding the drops of essential oils. Lanaform cannot be held liable in the event of accidental damage resulting from any use contrary to the instructions given in these instructions for use. Maintenance and storage report_problem insert_photo3 When not using the diffuser, empty the water from the reservoir. Never empty the water from the reservoir on the side of the air outlet. If water enters the air outlet, it will damage the device! (Fig. 3)
Use a container to pour water into the reservoir. Do not shake the diffuser. Do not move the diffuser when there is water in the reservoir.
To prevent this from happening: report_problem Always unplug the device with dry hands before cleaning it! If the water contains too much calcium and magnesium, it may deposit a “white powder” in the device. If this foam is deposited on the transducer (Fig. 1, point 7), it will prevent the device from working properly. We recommend: 13 · English Maintenance 01 using fresh, distilled or demineralised water for each use. 02 cleaning the reservoir every 3 days and cleaning the transducer every week. 03 emptying and cleaning the device (see explanations below), as well as making sure that all its parts are completely dry when it is not in use.
To clean the transducer insert_photo5: 01 place 2 to 5 drops of vinegar on its surface and allow to stand for 2 to 5 minutes. 02 brush the foam off the surface with a soft brush or cotton swab. Do not use a hard tool to scrape the surface. 03 Do not use soap, solvent or spray cleaner to clean the transducer. To clean the reservoir and reservoir cover: 01 Use a soft cloth and vinegar if there are any foam or limescale deposits on the inside. 02 Rinse with clean water. report_problem Never use products containing bleach to clean the device, but only dishwashing detergent or vinegar! 14 · English report_problem Never immerse the base (Fig. 1, point 9) in water! Storage Store the device in a dry, cool place out of reach of children after cleaning and drying. healing Faults and remedies In case of malfunction, under normal conditions of use, please refer to the following list: help_outline The diffuser is not plugged in. sentiment_satisfied Check whether the device is connected and that there is no mains fault. help_outline The water level in the reservoir is too low. sentiment_satisfied Add water to the reservoir. help_outline Water leakage from the reservoir. sentiment_satisfied Check that the reservoir is in the right position. help_outline The temperature of the unit is too low. sentiment_satisfied Place the unit in a room at room temperature half an hour before use.
sentiment_dissatisfied No mist. help_outline The water has been standing in the reservoir for too long. sentiment_dissatisfied Low intensity. sentiment_satisfied Clean the reservoir and pour fresh, distilled or demineralised water into it. 15 · English sentiment_dissatisfied Mist has an unusual smell.
16 · English help_outline Too much/too little water in the reservoir. sentiment_satisfied Empty (add) the water from the reservoir. help_outline Sediment on the transducer. sentiment_satisfied Clean the transducer. help_outline The water is too cold. sentiment_satisfied Use room temperature water. help_outline Water is not clean. sentiment_satisfied Clean the reservoir and pour fresh, distilled or demineralised water into it. Technical data
Reference: LA120325 Power supply: DC 24V Consumption: 12 W Reservoir capacity: 120ml Emission rate: 10-30 ml/h Dimensions: 11×11×18.8 cm dvice regarding the disposal of waste All the packaging is composed of materials that pose no hazard for the environment and which can be disposed of at your local sorting centre to be used as secondary raw materials. The cardboard may be disposed of in a paper recycling bin. The packaging film must be taken to your local sorting and recycling centre. Limited warranty
When you have finished using the device, please dispose of it in an environmentally friendly way and in accordance with the law. The Lanaform guarantee does not cover damage caused as a result of normal wear to this product. In addition, the guarantee covering this Lanaform product does not cover damage caused by abusive or inappropriate or incorrect use, accidents, the use of unauthorized accessories, changes made to the product or any other circumstance, of whatever sort, that is outside Lanaform’s control. Lanaform may not be held liable for any type of circumstantial, indirect or specific damage. 17 · English Lanaform guarantees this product against any material or manufacturing defect for a period of two years from the date of purchase, except in the circumstances described below. All implicit guarantees relating to the suitability of the product are limited to a period of two years from the initial date of purchase as long as a copy of the proof of purchase can be supplied. 18 · English
On receipt, Lanaform will repair or replace your appliance at its discretion and will return it to you. The guarantee is only valid through Lanaform’s Service Centre. Any attempt to maintain this product by a person other than Lanaform’s Service Centre will render this guarantee void. FRANÇAIS