LANAFORM DAVY MIST - Essential Oil Diffuser

DAVY MIST - Essential Oil Diffuser LANAFORM - Free user manual and instructions

Find the device manual for free DAVY MIST LANAFORM in PDF.

📄 112 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice LANAFORM DAVY MIST - page 5
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeUltrasonic Essential Oil Diffuser
BrandLANAFORM
ModelDAVY MIST
Tank Capacity120 ml
Diffusion Intensities2 levels: 10-20 ml/h and 20-30 ml/h
Diffusion ModeContinuous
Light TypeWarm white LED with adjustable intensity
Light FunctionIndependent from diffusion
Power SupplyDC 24V via included AC adapter
Power Consumption12 W
Dimensions (L × W × H)11 × 11 × 18.8 cm
MaterialsBeech wood base, smoked glass cover, plastic tank
Automatic Shut-offYes (safety when water level is low)
Tank CleaningEvery 3 days with water and vinegar
Transducer CleaningEvery week with vinegar and soft brush
Usage PrecautionsDo not immerse the base, do not use synthetic fragrances
Recommended Essential OilsPure and 100% natural, 3-4 drops max
Child SafetyDo not leave unattended, keep out of reach
Warranty2 years (excluding improper use)
Included AccessoriesAC adapter, user manual

Frequently Asked Questions - DAVY MIST LANAFORM

How to turn on and adjust diffusion?
Press the button once to start diffusion at low intensity (10-20 ml/h). A second press switches to high intensity (20-30 ml/h), a third press stops diffusion. To turn off the device completely, press and hold the button for 2 seconds.
How to adjust the light?
Turn the knob clockwise to turn on and increase the light intensity. Counterclockwise to decrease and turn off. The light can operate independently from diffusion.
What type of water to use?
Use fresh water, preferably demineralized or distilled, to avoid limescale deposits. Do not exceed the indicated maximum level.
How many drops of essential oil to add?
Add 3 to 4 drops of pure and natural essential oil to the water. Never pour oil without water. Excessive dosage may damage the device.
Why is the diffuser not producing mist?
Check that the device is plugged in, the tank has enough water, and the transducer is clean. If the water is too cold, let the device adapt to room temperature for 30 minutes before use.
How to clean the transducer?
Place 2 to 5 drops of vinegar on the transducer, let it sit for 2 to 5 minutes, then gently brush with a soft brush or cotton swab. Never use a hard tool.
How often to clean the tank?
Clean the tank every 3 days with a soft cloth, water and vinegar if necessary. Rinse with clear water. Do not immerse the base.
Can I use synthetic fragrances?
No, use only pure and natural essential oils. Synthetic fragrances may damage the device.
What to do in case of unusual odor?
Empty the stagnant water, clean the tank and refill with fresh water. If the smell persists, also clean the transducer.
How to avoid limescale deposits?
Use demineralized or distilled water. Clean the transducer regularly with vinegar. Avoid leaving water in the tank when the device is not in use.

User questions about DAVY MIST LANAFORM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Essential Oil Diffuser in PDF format for free! Find your manual DAVY MIST - LANAFORM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DAVY MIST by LANAFORM.

USER MANUAL DAVY MIST LANAFORM

Thank you for choosing the Davy Mist diffuser by Lanaform. Thanks to its variable intensity light and 2 diffusion intensities, the Davy Mist essential oil diffuser invites you to relax and enjoy the benefits of aromatherapy. Designed from noble materials (smooth glass and beech wood base), the Davy Mist diffuser offers a modern, sleek design that will easily adapt to all current trends.

The photographs and other images of the product in this manual and on the packaging are as accurate as possible, but do not claim to be a perfect reproduction of the product.
Please read all instructions before using your humidifier, particularly these essential safety instructions.

Always place the device on a hard, flat, horizontal surface inside your home. Keep it away from walls and heat sources such as stoves, radiators, etc. Caution:

If it is not placed on a horizontal surface, it may not work properly. Check that your mains voltage is the same as that of your appliance. Do not connect or disconnect the plug with wet hands. If the power cable is damaged, it must be replaced by a similar cable available from the supplier or the supplier's after-sales department. Do not leave the device in the sun for a long period of time. Do not dismantle the device completely. Do not lift the glass cover when the device is on. If you notice a suspicious smell or sound, switch the device off immediately and consult the "Troubleshooting" section of these instructions for use. If the problem persists, have it examined by the supplier or its after-sales department. Do not use essential oils that are not recommended for diffusion. To do this, consult the

instructions for using the essential oils in these instructions for use. Do not use perfumes or synthetic essences as this may damage the device. Microorganisms that may be present in water or in the environment where the device is used or stored may develop in the water reservoir and be blown into the air, resulting in possible serious health problems if the water is not renewed and the reservoir is not properly cleaned every 3 days. Use only the AC adapter supplied with this device. The supplied adapter should only be used with the device and not for other purposes. Do not wash the entire unit with water and do not immerse it. Consult the cleaning instructions in these instructions for use. Do not use chemicals (such as acids, alkalis, etc.) or corrosive detergents to clean the device. Never scrape the transducer

with a hard tool and consult the cleaning instructions in this manual. Be sure to never empty the water from the reservoir into the air outlets, as this will damage the diffuser. Empty the water in the opposite direction of the air outlet. For optimal maintenance, use mineral water. Do not fill above the line indicating the maximum water level. Always add water before adding essential oils. Do not use essential oils without diluting them in water. This device is not intended to be used by people, including children, with reduced physical, sensory or mental capabilities, or people with lack of experience or knowledge, unless they are supervised or instructed on the use of the device by a person responsible for their safety. Children should be supervised to make sure they do not play with the device. Never move the device

while it is running. Avoid dropping or hitting the device Unplug the device when filling with water or during maintenance. Never leave water in the reservoir when the product is not in use. Never place anything on the device while it is running. Place the power cord so that no one can trip when the device is in use. Remove the power cord when the product is no longer in use. Use this device only for its intended purpose, as described in these instructions for use.

Device components 1

01 Mist outlet
02 Glass cover
03 Internal reservoir cover
04 LED lamp
05 Water reservoir
06 Air outlet

07 Transducer
08 DC jack socket
09 Beach wood base
10 Diffusion and light adjustment button

Instructions for use

Characteristics

  • Ultrasound diffuser
  • Beach wood base
    Glass cover
    120 ml capacity
    2 emission intensities (10-20 ml/hr) & (20-30ml/hr)

Continuous diffusion
Warm white light
Variable light intensity
Diffusion-independent light
- Auto shut-off

Preparation 2

01 Place the Davy Mist diffuser in the room half an hour before turning it on so that it can adjust to the room temperature.
02 Ensure that it is always placed on a hard, flat and horizontal surface.
03 Make sure the device is clean before starting to use it.
04 Remove the glass cover (1).
05 Then remove the reservoir cover (2).
06 Pour fresh, preferably demineralised water into the reservoir and do not exceed the maximum level (3).
07 Pour 3 or 4 drops of essential oil into the water (4).
08 Replace the reservoir cover then the glass cover (5).
09 Make sure your hands are completely dry when connecting (and even disconnecting) the device (6).
10 The diffuser is now operational.

Instructions for use

Adjusting the diffusion

  • Press once on the diffusion and light adjustment button (Fig. 1, point 10) to start diffusion. It defaults to the lowest intensity (10-20ml/hr).
  • Press the button a second time to select the high intensity diffusion (20-30ml/hr).
  • Press the button a third time: the mist emission turns off. By default, the light mode is not disabled. To switch off the device completely (diffusion + light), press and hold the diffusion and light adjustment button for two seconds. To start the diffuser again, press the diffusion and light adjustment button (Fig. 1, point 10. The emission intensity is low (10-20ml/hr) and the light intensity is similar to that before turning off.

Adjusting the Light Mode

  • Turn the light adjustment button (Fig. 1, point 10) clockwise to activate the light and increase the intensity.
  • Turn the light adjustment button (Fig. 1, point 10) anti-clockwise to reduce the light intensity and turn it off.

① By default, the light does not turn off when diffusion stops. To turn the light off, turn the light adjustment button (Fig. 1, point 10) in the opposite direction until the

light is turned off or hold the diffusion and light adjustment button for two seconds.

Even though there is a safety device that stops the transducer from working, do not leave the device connected when you are not using it.
Additional information on the use of essential oils.

  • Before using the essential oils, please check the harmful effects that use of these products may have on your health.
    Always choose quality essential oils: pure and 100% natural and intended for diffusion. Use them with moderation and care. Follow the instruc-tions and warnings indicated on the packaging of the essential oils, in particular ensuring that:
  • Pregnant women and people with epilepsy, asthma or allergies, heart problems or serious conditions must not use essential oils.
    Essential oils should only be used for periods not exceeding 10 minutes in a baby's room (-3 years old) and only when the baby is not present in the room.
    Make sure that children and minors do not play with or use the device.
  • Only a few drops (3 to 4 drops at most) of essential oils are sufficient to ensure the device works properly and the fragrance is diffused. Excessive use of essential oils could damage the device.

  • First, pour the water into the reservoir before adding the drops of essential oils.

  • Lanaform cannot be held liable in the event of accidental damage resulting from any use contrary to the instructions given in these instructions for use.

Maintenance and storage

3 When not using the diffuser, empty the water from the reservoir. Never empty the water from the reservoir on the side of the air outlet. If water enters the air outlet, it will damage the device! (Fig. 3)

To prevent this from happening:

Use a container to pour water into the reservoir.
- Do not shake the diffuser.
- Do not move the diffuser when there is water in the reservoir.

Always unplug the device with dry hands before cleaning it!

Maintenance

If the water contains too much calcium and magnesium, it may deposit a "white powder" in the device. If this foam is deposited on the transducer (Fig. 1, point 7), it will prevent the device from working properly.

We recommend:

01 using fresh, distilled or demineralised water for each use.
02 cleaning the reservoir every 3 days and cleaning the transducer every week.
03 emptying and cleaning the device (see explanations below), as well as making sure that all its parts are completely dry when it is not in use.

LANAFORM DAVY MIST - Maintenance - 1

To clean the transducer 5:

01 place 2 to 5 drops of vinegar on its surface and allow to stand for 2 to 5 minutes.
02 brush the foam off the surface with a soft brush or cotton swab. Do not use a hard tool to scrape the surface.
03 Do not use soap, solvent or spray cleaner to clean the transducer.

To clean the reservoir and reservoir cover:

01 Use a soft cloth and vinegar if there are any foam or limescale deposits on the inside.
02 Rinse with clean water.

Never use products containing bleach to clean the device, but only dishwashing detergent or vinegar!
Never immerse the base (Fig. 1, point 9) in water!

Storage

Store the device in a dry, cool place out of reach of children after cleaning and drying.

LANAFORM DAVY MIST - Storage - 1

Faults and remedies

In case of malfunction, under normal conditions of use, please refer to the following list:

◎ No mist.
⑦ The diffuser is not plugged in.◎ Check whether the device is connected and that there is no mains fault.
⑦ The water level in the reservoir is too low.◎ Add water to the reservoir.
⑦ Water leakage from the reservoir.◎ Check that the reservoir is in the right position.
⑦ The temperature of the unit is too low.◎ Place the unit in a room at room temperature half an hour before use.
◎ Mist has an unusual smell.
⑦ The water has been standing in the reservoir for too long.◎ Clean the reservoir and pour fresh, distilled or deminer-alised water into it.
◎ Low intensity.
② Too much/too little water in the reservoir.◎ Empty (add) the water from the reservoir.
⑦ Sediment on the transducer.◎ Clean the transducer.
⑦ The water is too cold.◎ Use room temperature water.
⑦ Water is not clean.◎ Clean the reservoir and pour fresh, distilled or deminer-alised water into it.

Technical data

Reference: LA120325
Power supply: DC 24V
Consumption: 12 W
Reservoir capacity: 120ml
- Emission rate: 10 - 30ml/h
Dimensions: 11 × 11 × 18.8 cm

LANAFORM DAVY MIST - Technical data - 1

Advice regarding the disposal of waste

All the packaging is composed of materials that pose no hazard for the environment and which can be disposed of at your local sorting centre to be used as secondary raw materials. The cardboard may be disposed of in a paper recycling bin. The packaging film must be taken to your local sorting and recycling centre.

When you have finished using the device, please dispose of it in an environmentally friendly way and in accordance with the law.

Limited warranty

Lanaform guarantees this product against any material or manufacturing defect for a period of two years from the date of purchase, except in the circumstances described below.

The Lanaform guarantee does not cover damage caused as a result of normal wear to this product. In addition, the guarantee covering this Lanaform product does not cover damage caused by abusive or inappropriate or incorrect use, accidents, the use of unauthorized accessories, changes made to the product or any other circumstance, of whatever sort, that is outside Lanaform's control.

Lanaform may not be held liable for any type of circumstantial, indirect or specific damage.

All implicit guarantees relating to the suitability of the product are limited to a period of two years from the initial date of purchase as long as a copy of the proof of purchase can be supplied.

On receipt, Lanaform will repair or replace your appliance at its discretion and will return it to you. The guarantee is only valid through Lanaform's Service Centre. Any attempt to maintain this product by a person other than Lanaform's Service Centre will render this guarantee void.

FRANÇAIS

FR

Introduction

Manufacturer & Importer

Lanaform SA

Postal Address

Ruede laLegend,55

4141 Louvigné, Belgium

+3243609291

info@lanaform.com

www.lanaform.com

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : LANAFORM

Model : DAVY MIST

Category : Essential Oil Diffuser