DCM270 - Multimeter VELLEMAN - Free user manual and instructions
Find the device manual for free DCM270 VELLEMAN in PDF.
| Product type | Digital multimeter |
| Brand | Velleman |
| Model | DCM270 |
| Category | Multimeter |
| Dimensions (L x W x H) | 140 x 70 x 30 mm |
| Weight | Approx. 200 g |
| Power supply | 9V battery (type 6F22) |
| Display | 3 1/2 digit LCD display (2000 counts) |
| Main functions | AC/DC voltage measurement, AC/DC current, resistance, continuity test, diode test |
| DC voltage range | 200 mV to 600 V |
| AC voltage range | 200 V to 600 V |
| DC current range | 200 µA to 10 A |
| Resistance range | 200 Ω to 2 MΩ |
| Safety | CAT II 600 V |
| Maintenance and cleaning | Clean with a dry cloth, avoid moisture |
| Spare parts available | Batteries, fuses |
| Repairability | Repairable by a professional |
| General information | Supplied with test leads and user manual |
Frequently Asked Questions - DCM270 VELLEMAN
User questions about DCM270 VELLEMAN
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Multimeter in PDF format for free! Find your manual DCM270 - VELLEMAN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DCM270 by VELLEMAN.
USER MANUAL DCM270 VELLEMAN
natural_image
Close-up of a handheld digital clamp meter with a strap and control panel (no visible text or symbols)
USER MANUAL
GEBRUIKERSHANDLEIDING
NOTICE D'EMPLOI
MANUAL DEL USUARIO
BEDIENUNGSANLEITUNG
MANUALE UTENTE
CE
1. Introduction
To all residents of the European Union
Important environmental information about this product

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialised company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for buying the DCM269/DCM270! Read the manual carefully before bringing this device into service.
2. Features
• 3 2/3-digit (2400 counts) LCD display with white LED backlight
- 18mm (0.7") jaw opening
- 0.1 \~ 200A current measurement (DCM269) or 0.001 \~ 80A AC and DC current measurement (DCM270)
• built-in non-contact AC voltage detector
- incorporated flashlight
• frequency measurement 40Hz-1kHz (DCM269 only)
• autoranging with auto power-off
- data-hold function
• overload protection for all ranges
• overrange and low battery indication
- supplied with pouch
3. Specifications
General Specifications
Display 3 2/3 digit LCD (2400 count) with white LED backlight
Polarity "-" indicates negative polarity
Overload Indication "OL" is displayed on the LCD
DCA Resetting Adjustment one-touch "zero" key
Display Rate 2 readings/sec., nominal
Battery 2 x 1.5V AAA-batteries
Low-Battery Indication "BATT"
Auto OFF ± 7 minutes
Temperature Range 0 to +30°C (32 to 86°F), 90% RH
30 to 40°C (86 to 104°F), 75% RH
40 to 50°C (104 to 122°F), 45% RH
Storage Temperature -30 to +60°C (-14 to 140°F), < 90% RH
Altitude < 3000m
Weight 175g with battery
Dimensions 164 x 65 x 32mm (H x W x D)
Jaw Opening 18mm
Standards IEC 1010 Category II 600V
Range Specifications (DCM269)
| Function | Range | Resolution | Accuracy |
| DC current 200A 200mA ± (2.8% + 8 digits) | |||
| AC current (50/60Hz) 200A 200mA ± (3.0% + 8 digits) | |||
| Frequency (auto-ranging) | 40-51Hz 0.01Hz ± (1.2% + 3 digits) | input sensitivity5A AC RMS min. | |
| 51-510Hz | 0.1Hz | ||
| 0.51-1KHz | 0.001KHz | ||
| Non-contact voltage 100Vac to 600Vac 50/60Hz | |||
Range Specifications (DCM270)
| Function | Range | Resolution | Accuracy |
| DC current | 2A 1mA ± (3.0% + 10 digits) | ||
| 80A 100mA ± (2.8% + 8 digits) | |||
| AC current (50/60Hz) | 2A 1mA ± (2.8% + 10 digits) | ||
| 80A 100mA ± (2.8% + 8 digits) | |||
| Non-contact voltage 100Vac to 600Vac 50/60Hz | |||
4. Description
- Jaws
- Flashlight button
- Rotary function switch
- Data-hold and backlight button
- LCD display
- Trigger
- DCA ZERO key
- Non-contact AC voltage detection LEDs
- Probe tip

5. Safety

Important information with reference to safety, consult the manual

Double insulation
This meter has been designed with attention to safety, but the user must also take care to respect the safety prescriptions described below.
- Do not exceed the maximum values for current or voltage measurements.
- Use extreme caution when working with voltages in excess of 25V AC rms. These voltages are considered a shock hazard.
- Never operate the device if the back panel or the cover of the battery or fuse compartment is not securely in place.
- Input limits: 200A (AC current), ±200A (DC current)
6. Operation
a) AC Current Measurements
1) Set the function switch to the ACA range.
2) Press the trigger and enclose a single conductor with the jaws, which must be fully closed (see figure).
3) Read the ACA value on the LCD.
b) DC Current Measurements
1) Set the function switch to the DCA range.
2) Press the ZERO key to reset the display.
3) Press the trigger to open the jaws.
4) Enclose the conductor to be measured. Remember: the jaws must be fully closed.
5) Read the DCA value on the LCD.

natural_image
Line drawing of two identical clamp meters with digital displays and a handle, shown against diagonal lines (no text or symbols)c) Non-contact Voltage Measurements

WARNING
Risk of electrocution. Before use you should always test the voltage detector on a known live circuit to verify proper operation of the meter
1) Hold the probe against the hot conductor or against the hot side of the electrical outlet..
2) The two detector LEDs light up red if an AC voltage is detected.
NOTE: The conductors in an electrical cord are often twisted. Rub the probe tip along a length of cord to be sure the tip passes in close proximity to the live conductor.
NOTE: The detector is a sensitive device. Static electricity or a different energy source may randomly trigger the sensor at random. This is simply part of the normal operation of this device, it is not a malfunction.
d) Frequency Measurements (DCM269 only)
1) Put the function switch in the Hz-position.
2) Close the jaws completely around the conductor to be measured.
3) Read the frequency value on the LCD.
e) Flashlight
Hold the top button to turn on the flashlight.
f) Data-Hold
Press the "Hold backlight" button to freeze the current reading on the LCD. The word "HOLD" will appear on the LCD when the data-hold mode is activated. Simply press the "Hold backlight" button again to return to the normal display mode. The word "HOLD" is erased from the display.
g) Backlight
Hold the "Hold backlight" button for more than 2 seconds to turn on the backlight. This will also activate the data-hold function. Press the button momentarily to deactivate the data-hold function. Hold the "Hold Backlight" button for more than 2 seconds to deactivate the backlight.
h) Auto Power OFF
The device is turned off automatically after 7 minutes if no button is pressed.
i) Battery Replacement
1) Replace the batteries when the low-battery symbol is displayed.
2) Turn off the device and loosen the screw of the battery compartment.
3) Remove the compartment cover and replace the two 1.5V AAA batteries.
4) Replace the cover and fasten the screw.
For more info concerning this product, please visit our website www.velleman.eu. The contents of this manual are subject to change without prior notice.
1. Inleiding
Auto OFF ± 7 minutes
natural_image
Line drawing of two identical analog clamp devices with control knobs and a digital display (no text or symbols)Velleman® Service and Quality Warranty
Velleman® has over 35 years of experience in the electronics world and distributes its products in more than 85 countries. All our products fulfil strict quality requirements and legal stipulations in the EU. In order to ensure the quality, our products regularly go through an extra quality check, both by an internal quality department and by specialized external organisations. If, all precautionary measures notwithstanding, problems should occur, please make appeal to our warranty (see guarantee conditions).
General Warranty Conditions Concerning Consumer Products (for EU):
- All consumer products are subject to a 24-month warranty on production flaws and defective material as from the original date of purchase.
- Velleman® can decide to replace an article with an equivalent article, or to refund the retail value totally or partially when the complaint is valid and a free repair or replacement of the article is impossible, or if the expenses are out of proportion.
You will be delivered a replacing article or a refund at the value of 100% of the purchase price in case of a flaw occurred in the first year after the date of purchase and delivery, or a replacing article at 50% of the purchase price or a refund at the value of 50% of the retail value in case of a flaw occurred in the second year after the date of purchase and delivery.
• Not covered by warranty:
- all direct or indirect damage caused after delivery to the article (e.g. by oxidation, shocks, falls, dust, dirt, humidity...), and by the article, as well as its contents (e.g. data loss), compensation for loss of profits;
- frequently replaced consumable goods, parts or accessories such as batteries, lamps, rubber parts, drive belts... (unlimited list);
- flaws resulting from fire, water damage, lightning, accident, natural disaster, etc. ...;
- flaws caused deliberately, negligently or resulting from improper handling, negligent maintenance, abusive use or use contrary to the manufacturer's instructions;
- damage caused by a commercial, professional or collective use of the article (the warranty validity will be reduced to six (6) months when the article is used professionally);
- damage resulting from an inappropriate packing and shipping of the article;
- all damage caused by modification, repair or alteration performed by a third party without written permission by Velleman®.
- Articles to be repaired must be delivered to your Velleman® dealer, solidly packed (preferably in the original packaging), and be completed with the original receipt of purchase and a clear flaw description.
- Hint: In order to save on cost and time, please reread the manual and check if the flaw is caused by obvious causes prior to presenting the article for repair. Note that returning a non-defective article can also involve handling costs.
• Repairs occurring after warranty expiration are subject to shipping costs. - The above conditions are without prejudice to all commercial warranties.