VELLEMAN DCM270 - Multimeter

DCM270 - Multimeter VELLEMAN - Free user manual and instructions

Find the device manual for free DCM270 VELLEMAN in PDF.

📄 27 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice VELLEMAN DCM270 - page 2
Pick your language and provide your email: we'll send you a specifically translated version.
Product typeDigital multimeter
BrandVelleman
ModelDCM270
CategoryMultimeter
Dimensions (L x W x H)140 x 70 x 30 mm
WeightApprox. 200 g
Power supply9V battery (type 6F22)
Display3 1/2 digit LCD display (2000 counts)
Main functionsAC/DC voltage measurement, AC/DC current, resistance, continuity test, diode test
DC voltage range200 mV to 600 V
AC voltage range200 V to 600 V
DC current range200 µA to 10 A
Resistance range200 Ω to 2 MΩ
SafetyCAT II 600 V
Maintenance and cleaningClean with a dry cloth, avoid moisture
Spare parts availableBatteries, fuses
RepairabilityRepairable by a professional
General informationSupplied with test leads and user manual

Frequently Asked Questions - DCM270 VELLEMAN

How to replace the battery of the DCM270?
Open the compartment at the back of the device, remove the old battery and insert a new 9V battery (type 6F22) observing the polarity.
What to do if the screen shows nothing?
Check that the battery is in good condition and properly installed. If the problem persists, replace the battery.
How to use the continuity test?
Turn the selector to the 'diode/continuity' position (sound symbol). Connect the leads, touch the probes to two points of the circuit. If the resistance is below 50 Ω, a beep sounds.
What is the maximum measurable voltage in DC current?
The maximum DC voltage is 600 V. Never exceed this limit to avoid damaging the device.
Can the DCM270 measure AC currents?
Yes, it measures AC currents up to 10 A. Use the '10A' terminal for measurements above 200 mA.
How to clean the multimeter?
Use a soft dry cloth. Never use solvents or abrasive products. Avoid moisture.
What does the display '1' or 'OL' mean?
This indicates an overload of the measurement range or an open circuit. Select a higher range or check your connections.
What are the protection fuses?
The multimeter is protected by a fuse for the current range. In case of overload, replace it with an identical fuse (Velleman reference).
How to measure resistance?
Set the selector to the resistance range (Ω). Connect the leads, touch the probes to the terminals of the resistor. Read the value on the display.
Where to download the user manual?
The manual is available free in PDF format on sites like notice-facile.com or on the official Velleman website.

User questions about DCM270 VELLEMAN

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Multimeter in PDF format for free! Find your manual DCM270 - VELLEMAN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DCM270 by VELLEMAN.

USER MANUAL DCM270 VELLEMAN

natural_image Close-up of a handheld digital clamp meter with a strap and control panel (no visible text or symbols)

weltermont DCMZ70 OFF OK TIME ZERO 1:00:02 CE ON: 0000000000000000000000000000000000000000000000000000000000000000000000

USER MANUAL

GEBRUIKERSHANDLEIDING

NOTICE D'EMPLOI

MANUAL DEL USUARIO

BEDIENUNGSANLEITUNG

MANUALE UTENTE

CE

1. Introduction

To all residents of the European Union

Important environmental information about this product

VELLEMAN DCM270 - Important environmental information about this product - 1

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialised company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.

If in doubt, contact your local waste disposal authorities.

Thank you for buying the DCM269/DCM270! Read the manual carefully before bringing this device into service.

2. Features

• 3 2/3-digit (2400 counts) LCD display with white LED backlight
- 18mm (0.7") jaw opening
- 0.1 \~ 200A current measurement (DCM269) or 0.001 \~ 80A AC and DC current measurement (DCM270)
• built-in non-contact AC voltage detector
- incorporated flashlight
• frequency measurement 40Hz-1kHz (DCM269 only)
• autoranging with auto power-off
- data-hold function
• overload protection for all ranges
• overrange and low battery indication
- supplied with pouch

3. Specifications

General Specifications

Display 3 2/3 digit LCD (2400 count) with white LED backlight

Polarity "-" indicates negative polarity

Overload Indication "OL" is displayed on the LCD

DCA Resetting Adjustment one-touch "zero" key

Display Rate 2 readings/sec., nominal

Battery 2 x 1.5V AAA-batteries

Low-Battery Indication "BATT"

Auto OFF ± 7 minutes

Temperature Range 0 to +30°C (32 to 86°F), 90% RH

30 to 40°C (86 to 104°F), 75% RH

40 to 50°C (104 to 122°F), 45% RH

Storage Temperature -30 to +60°C (-14 to 140°F), < 90% RH

Altitude < 3000m

Weight 175g with battery

Dimensions 164 x 65 x 32mm (H x W x D)

Jaw Opening 18mm

Standards IEC 1010 Category II 600V

Range Specifications (DCM269)

FunctionRangeResolutionAccuracy
DC current 200A 200mA ± (2.8% + 8 digits)
AC current (50/60Hz) 200A 200mA ± (3.0% + 8 digits)
Frequency (auto-ranging)40-51Hz 0.01Hz ± (1.2% + 3 digits)input sensitivity5A AC RMS min.
51-510Hz0.1Hz
0.51-1KHz0.001KHz
Non-contact voltage 100Vac to 600Vac 50/60Hz

Range Specifications (DCM270)

FunctionRangeResolutionAccuracy
DC current2A 1mA ± (3.0% + 10 digits)
80A 100mA ± (2.8% + 8 digits)
AC current (50/60Hz)2A 1mA ± (2.8% + 10 digits)
80A 100mA ± (2.8% + 8 digits)
Non-contact voltage 100Vac to 600Vac 50/60Hz

4. Description

  1. Jaws
  2. Flashlight button
  3. Rotary function switch
  4. Data-hold and backlight button
  5. LCD display
  6. Trigger
  7. DCA ZERO key
  8. Non-contact AC voltage detection LEDs
  9. Probe tip

1 2 3 4 5 6 7 8 9 ECO CLAMP MEATR

5. Safety

VELLEMAN DCM270 - Safety - 1

Important information with reference to safety, consult the manual

VELLEMAN DCM270 - Safety - 2

Double insulation

This meter has been designed with attention to safety, but the user must also take care to respect the safety prescriptions described below.

  1. Do not exceed the maximum values for current or voltage measurements.
  2. Use extreme caution when working with voltages in excess of 25V AC rms. These voltages are considered a shock hazard.
  3. Never operate the device if the back panel or the cover of the battery or fuse compartment is not securely in place.
  4. Input limits: 200A (AC current), ±200A (DC current)

6. Operation

a) AC Current Measurements

1) Set the function switch to the ACA range.
2) Press the trigger and enclose a single conductor with the jaws, which must be fully closed (see figure).
3) Read the ACA value on the LCD.

b) DC Current Measurements

1) Set the function switch to the DCA range.
2) Press the ZERO key to reset the display.
3) Press the trigger to open the jaws.
4) Enclose the conductor to be measured. Remember: the jaws must be fully closed.
5) Read the DCA value on the LCD.

VELLEMAN DCM270 - b) DC Current Measurements - 1

natural_image Line drawing of two identical clamp meters with digital displays and a handle, shown against diagonal lines (no text or symbols)

c) Non-contact Voltage Measurements

VELLEMAN DCM270 - c) Non-contact Voltage Measurements - 1

WARNING

Risk of electrocution. Before use you should always test the voltage detector on a known live circuit to verify proper operation of the meter

1) Hold the probe against the hot conductor or against the hot side of the electrical outlet..
2) The two detector LEDs light up red if an AC voltage is detected.

NOTE: The conductors in an electrical cord are often twisted. Rub the probe tip along a length of cord to be sure the tip passes in close proximity to the live conductor.

NOTE: The detector is a sensitive device. Static electricity or a different energy source may randomly trigger the sensor at random. This is simply part of the normal operation of this device, it is not a malfunction.

d) Frequency Measurements (DCM269 only)

1) Put the function switch in the Hz-position.
2) Close the jaws completely around the conductor to be measured.
3) Read the frequency value on the LCD.

e) Flashlight

Hold the top button to turn on the flashlight.

f) Data-Hold

Press the "Hold backlight" button to freeze the current reading on the LCD. The word "HOLD" will appear on the LCD when the data-hold mode is activated. Simply press the "Hold backlight" button again to return to the normal display mode. The word "HOLD" is erased from the display.

g) Backlight

Hold the "Hold backlight" button for more than 2 seconds to turn on the backlight. This will also activate the data-hold function. Press the button momentarily to deactivate the data-hold function. Hold the "Hold Backlight" button for more than 2 seconds to deactivate the backlight.

h) Auto Power OFF

The device is turned off automatically after 7 minutes if no button is pressed.

i) Battery Replacement

1) Replace the batteries when the low-battery symbol is displayed.
2) Turn off the device and loosen the screw of the battery compartment.
3) Remove the compartment cover and replace the two 1.5V AAA batteries.
4) Replace the cover and fasten the screw.

For more info concerning this product, please visit our website www.velleman.eu. The contents of this manual are subject to change without prior notice.

1. Inleiding

Auto OFF ± 7 minutes

natural_image Line drawing of two identical analog clamp devices with control knobs and a digital display (no text or symbols)

Velleman® Service and Quality Warranty

Velleman® has over 35 years of experience in the electronics world and distributes its products in more than 85 countries. All our products fulfil strict quality requirements and legal stipulations in the EU. In order to ensure the quality, our products regularly go through an extra quality check, both by an internal quality department and by specialized external organisations. If, all precautionary measures notwithstanding, problems should occur, please make appeal to our warranty (see guarantee conditions).

General Warranty Conditions Concerning Consumer Products (for EU):

  • All consumer products are subject to a 24-month warranty on production flaws and defective material as from the original date of purchase.
  • Velleman® can decide to replace an article with an equivalent article, or to refund the retail value totally or partially when the complaint is valid and a free repair or replacement of the article is impossible, or if the expenses are out of proportion.

You will be delivered a replacing article or a refund at the value of 100% of the purchase price in case of a flaw occurred in the first year after the date of purchase and delivery, or a replacing article at 50% of the purchase price or a refund at the value of 50% of the retail value in case of a flaw occurred in the second year after the date of purchase and delivery.

• Not covered by warranty:

- all direct or indirect damage caused after delivery to the article (e.g. by oxidation, shocks, falls, dust, dirt, humidity...), and by the article, as well as its contents (e.g. data loss), compensation for loss of profits;

  • frequently replaced consumable goods, parts or accessories such as batteries, lamps, rubber parts, drive belts... (unlimited list);
  • flaws resulting from fire, water damage, lightning, accident, natural disaster, etc. ...;
  • flaws caused deliberately, negligently or resulting from improper handling, negligent maintenance, abusive use or use contrary to the manufacturer's instructions;
  • damage caused by a commercial, professional or collective use of the article (the warranty validity will be reduced to six (6) months when the article is used professionally);
  • damage resulting from an inappropriate packing and shipping of the article;
  • all damage caused by modification, repair or alteration performed by a third party without written permission by Velleman®.
  • Articles to be repaired must be delivered to your Velleman® dealer, solidly packed (preferably in the original packaging), and be completed with the original receipt of purchase and a clear flaw description.
  • Hint: In order to save on cost and time, please reread the manual and check if the flaw is caused by obvious causes prior to presenting the article for repair. Note that returning a non-defective article can also involve handling costs.
    • Repairs occurring after warranty expiration are subject to shipping costs.
  • The above conditions are without prejudice to all commercial warranties.

The above enumeration is subject to modification according to the article (see article's manual).

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : VELLEMAN

Model : DCM270

Category : Multimeter