PARKSIDE PHD 100 A1 - Pressure washer

PHD 100 A1 - Pressure washer PARKSIDE - Free user manual and instructions

Find the device manual for free PHD 100 A1 PARKSIDE in PDF.

📄 58 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice PARKSIDE PHD 100 A1 - page 5
View the manual : Dansk DA Deutsch DE English EN Suomi FI Svenska SV
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypePressure Washer
BrandParkside
ModelPHD 100 A1
Max. Pressure100 bar
Rated Pressure70 bar
Water Flow Rate400 l/h
Motor Power1500 W
Power Supply230 V ~ 50 Hz
Weight6.0 kg
Dimensions (L x W x H)30 cm x 25 cm x 20 cm
Hose Length5 m
Cable Length5 m
Safety ClassII
Protection RatingIPX5
FunctionsVariable pressure trigger, detergent injection, safety lock
MaintenanceClean filter regularly, winterize before frost
Safety FeaturesOverload protection, automatic shut-off
Spare PartsGun, nozzle, hose available
RepairabilityUser replaceable parts

Frequently Asked Questions - PHD 100 A1 PARKSIDE

How do I start the pressure washer?
Connect the hose, turn on water supply, plug in the unit, set the trigger lock, and press the on/off switch.
What type of detergent can I use?
Use a pH-neutral detergent suitable for pressure washers. Do not use corrosive or flammable cleaning agents.
Can I use hot water?
No, this model is designed for cold water only. Using hot water can damage the pump and seals.
How should I store the pressure washer?
Drain all water, disconnect hoses, and store in a frost-free area. Avoid direct sunlight and extreme temperatures.
Why is there no pressure?
Check water supply is fully open, hose is not kinked, filter is clean, and trigger is properly engaged. Also ensure the unit is switched on.
How do I clean the water filter?
Unscrew the inlet connector, remove the filter, rinse with water, and reinstall. Clean after each use in dirty water conditions.
What safety precautions should I take?
Always wear protective eyewear, never point the spray at people or pets, and avoid electrical hazards by keeping plugs dry.
Can I use an extension cord?
Only use an extension cord rated for outdoor use with a minimum cross-section of 1.5 mm² and max length of 10 m.
What accessories are available?
Available accessories include a foam nozzle, rotating brush, and surface cleaner. Check with your retailer for compatibility.
What is the noise level?
The sound pressure level is approximately 75 dB(A). Use hearing protection if operating for extended periods.

User questions about PHD 100 A1 PARKSIDE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Pressure washer in PDF format for free! Find your manual PHD 100 A1 - PARKSIDE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PHD 100 A1 by PARKSIDE.

USER MANUAL PHD 100 A1 PARKSIDE

PRESSURE WASHER PHD 100 A1

PARKSIDE PHD 100 A1 - PRESSURE WASHER PHD 100 A1 - 1

natural_image Yellow and black PRO 100 AI water purifier on a grassy tile floor, no visible text or symbols on the device itself.

GB IE

PRESSURE WASHER

Translation of original operation manual

SE

HÖGTRYCKSTVÄTT

Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device.

FI

GB / IE Translation of original operation manual Page 5

Explanation of symbols 5

Symbols in the manual 6

General notes on safety 6

Areas of Application 8

General Description 8

Overview 8

Functional description 8

Scope of Delivery 9

Start-up 9

Setting up 9

Mains connection 9

Operation 10

Interrupting operation 10

Ending operation 10

Using detergents 10

Fixing the Wheels ....10

Removing the Chassis ....11

Cleaning and Maintenance ....11

Cleaning 11

Maintenance ....11

Storage 11

Waste Disposal and Environmental

Protection 12

Guarantee Notes 12

Technical data 13

Trouble shooting 14

Spare Parts Order 14

EU declaration of conformity .... 54

Exploded Drawing 56

Grizzly Service-Center 57

PARKSIDE PHD 100 A1 - FI - 1

For your own safety, and for the safety of others, please read these Operating Instructions carefully before you use the pressure washer for the first time! Keep the manual in a safe place and pass it on to any subsequent owner to ensure that the information contained therein is available at all times.

Notes on Safety

This Section is concerned with the basic safety rules when working with the pressure washer.

Explanation of symbols

PARKSIDE PHD 100 A1 - Explanation of symbols - 1

Attention!

PARKSIDE PHD 100 A1 - Explanation of symbols - 2

Before beginning work, familiarise yourself thoroughly with all the operating elements, particularly with how they function and operate. Ask a specialist if necessary.

PARKSIDE PHD 100 A1 - Explanation of symbols - 3

Attention: Remove the plug from the socket as soon as the power lead is damaged or cut.

PARKSIDE PHD 100 A1 - Explanation of symbols - 4

The pressure washer is not suitable for direct connection to the drinking water supply system.

PARKSIDE PHD 100 A1 - Explanation of symbols - 5

CAUTION. pressure washers can be dangerous if they are not operated correctly! The jet must never be directed at people, animals, electric equipment connected to the power supply or against the actual pressure washer.

PARKSIDE PHD 100 A1 - Explanation of symbols - 6

Information of the acoustic power level L_WA in dB.

PARKSIDE PHD 100 A1 - Explanation of symbols - 7

Electric appliances should not be disposed of in the domestic garbage.

PARKSIDE PHD 100 A1 - Explanation of symbols - 8

Safety class II

Symbols in the manual

PARKSIDE PHD 100 A1 - Symbols in the manual - 1

Warning symbols (the danger can be explained at the place of the exclamation mark) with information on damage and injury prevention.

PARKSIDE PHD 100 A1 - Symbols in the manual - 2

Instruction symbols (the instruction can be explained at the place of the exclamation mark) with information on preventing damage.

PARKSIDE PHD 100 A1 - Symbols in the manual - 3

Help symbols with information on improving tool handling.

General notes on safety

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • People who are unfamiliar with the operating instructions are not permitted to use the equipment. The operation of the equipment is not authorised for people under the age of 16.
  • Use the equipment only on a flat, stable surface.
  • For your safety, it is recommended that you wear safety glasses, safety boots and gloves and, if necessary, ear protection.
  • In the event of a fault or defect during operation, immediately switch off and unplug the equipment. Then read

page 14 of the operating instructions for possible fault causes or contact our service centre.

Working with the equipment

PARKSIDE PHD 100 A1 - Working with the equipment - 1

Caution: to avoid accidents and injuries:

PARKSIDE PHD 100 A1 - Working with the equipment - 2

CAUTION. pressure washers can be dangerous if they are not operated correctly! The jet must never be directed at people, animals, electric equipment connected to the power supply or against the actual pressure washer.

  • Do not direct the jet at yourself or others in order to clean clothes and shoes.
  • Do not operate the pressure washer when other people are in the immediate vicinity, other than they are also wearing protective clothes.
    • Take appropriate measures to keep children away from the equipment whilst it is running.
  • Dispose of the packaging material correctly.
  • Do not use the equipment in the vicinity of flammable liquids or gases. Non-observance will result in a risk of fire or explosion.
  • Do not spray combustible liquids. Risk of explosion.
  • Store the equipment in a dry place and out of reach of children.
  • Children must be supervised in order to ensure that they do not play with the equipment.
  • Ensure that no exhaust emissions oc-

cur within the vicinity of air inlets.

Caution! To avoid damage to the equipment and any possible person injury resulting from this:

- Do not work with damaged or incomplete equipment, or with equipment that has been converted without the approval of the manufacturer. Before initial operation, have a specialist check that the required electrical protection measures are in place.

- Never operate the pressure washer if the power supply cable or other important parts, such as the high-pressure hose or the gun, are damaged.

- Protect the pressure washer from frost and dry running.

- Use only original accessories and do not carry out conversion work on the equipment.

- Please read the notes in the operating instructions on the topic of “maintenance and cleaning”. Any measures above and beyond these, particularly opening the equipment, are to be carried out by an electrician. In the case of repairs, always contact our service centre.

- The washer was designed for operation with a neutral detergent based on a biologically decomposable anionic tenside. Other detergents or chemical substances could impair the safety of the washer and damage it.

- If you come into contact with cleaning agents, rinse with plenty of clean water.

• Water that has passed through a backflow preventer is classified as undrinkable.

• High-pressure hoses, fittings and

couplings are important for machine safety. Use only high-pressure hoses, fittings and couplings recommended by the manufacturer.

• To ensure machine safety, use only original replacement parts from the manufacturer or replacement parts authorised by the manufacturer.

Electrical safety:

PARKSIDE PHD 100 A1 - Electrical safety: - 1

Caution: to avoid accidents and injuries from electric shocks:

- The plug and socket of an extension cable must be water-tight!

PARKSIDE PHD 100 A1 - Electrical safety: - 2

Unsuitable extension cables can be dangerous as people can be harmed by an electric shock!

- Protect the electric plug connections against moisture.

- If there is a risk of flooding, fix the plug connections in an area that is safe from flooding.

- Ensure that the mains voltage matches the specifications on the rating plate.

- The electrical installation shall be according to national wiring rules.

- Connection to the mains must be carried out by an experienced electrician and meet the requirements of IEC 60364-1.

- The device must only be connected to a mains socket via a residual-current circuit breaker (RCD) with a rated leakage current of not more than 30 mA. Fuse: at least 6 ampere.

- Before each use, check the equipment, cable and plug for damage.

• If the power cable for this equipment

GB IE

is damaged, it must be replaced by the manufacturer, a customer service agent of the same or a similarly qualified person in order to prevent hazards.

  • Do not pull the plug from the socket by the cable. Protect the cable from heat, oil and sharp edges.
  • Do not carry or fix the equipment by the cable.
  • Use only extension cables that are protected from spray water and designed for outdoor use. Always fully unroll a cable drum before use. Check the cable for damage.
  • Before any work on the equipment, during work breaks and in the case of non-use, remove the plug from the socket.
  • The cross-section of the power supply cable must not be less than 2 x 1,5 mm ^2 .

Areas of Application

Only use the pressure washer in the following private home areas:

  • To clean machines, vehicles, buildings, work tools, facades, terraces, gardening tools, etc. with a high-pressure water jet.
  • Only use with original accessories and spares.
  • Observe the manufacturer's instructions for the device that is to be cleaned.

General Description

PARKSIDE PHD 100 A1 - General Description - 1

The diagram of the most important functional elements can be found on the foldout side.

Overview

PARKSIDE PHD 100 A1 - Overview - 1

1 High-pressure connection on the gun side

2 High-pressure connection on the washer side
3 High-pressure connection
4 Carrying handle
5 ON / OFF switch
6 Accessories holder
7 Power supply cable
8 Water connection with sieve insert (not visible)
9 Chassis

10 Gun
11 Jet lance
12 Adjustable flat-jet nozzle
13 High-pressure nozzle
14 Cleaning agent container with nozzle
15 Nozzle cleaning pin

Functional description

The pressure washer is to be used for washing with a high-pressure water jet. A detergent can be added if this is required. For the functions of the operating elements please refer to the subsequent description. Ensure that the safety instructions are always observed!

Scope of Delivery

Unpack the pressure washer and verify the contents:

  • Pressure washer
  • Chassis
  • Gun
  • High-pressure hose
  • Jet lance
  • High-pressure nozzle
  • Adjustable flat-jet nozzle
  • Cleaning agent container with nozzle
  • Nozzle cleaning pin

Start-up

PARKSIDE PHD 100 A1 - Start-up - 1

In keeping with current regulations a pressure washer must never be operated off the drinking water mains supply without a controllable backflow preventer. A suitable backflow preventer in conformity with EN 12729 type BA must be used.

Water that has passed through a backflow preventer is classified as undrinkable.

PARKSIDE PHD 100 A1 - Start-up - 2

A backflow preventer is available from specialist retailers.

Setting up

PARKSIDE PHD 100 A1 - Setting up - 1

- Screw the equipment side of the high-pressure hose connection (2) to the high-pressure hose connection (3) on the equipment.

  • Screw the gun side of the high-pressure hose connection (1) to the spray gun (10)
    • Establish the water supply by

connecting the rapid-action water supply connector to the water connection with sieve insert (8).

PARKSIDE PHD 100 A1 - Setting up - 2

- Connect to the spray gun (10) by inserting and screwing in the jet tube (11).

- If the jet tube (11) is fitted, connect either the adjustable fan nozzle (12), high-pressure jet (13) or cleaning agent container to the nozzle (14) by screwing together with the jet tube (11). With using the cleaning agent container with the nozzle (A 14), pour only cleaning agent into the container. It is sucked in automatically.

The width of the jet can be increased by turning the end of the nozzle to the left. To reduce the width of the jet, turn the end of the nozzle to the right.

Mains connection

The pressure washer you have acquired is already fitted with a mains plug. The pressure washer must only be connected to an earthed socket 230 V \~ 50Hz.

PARKSIDE PHD 100 A1 - Mains connection - 1

Only operate the pressure washer after all the above points have been observed.

  • Ensure that the pressure washer is turned off by its ON / OFF switch (A 5).
  • Insert the mains plug into the mains socket

GBIE

Operation

  • Connect the equipment to the water tap. Observe the regulations for the use of a system separator.
  • Turn on the water tap entirely.

PARKSIDE PHD 100 A1 - Operation - 1

Never operate the pressure washer with a closed water tap. Dry running will damage the washer!

PARKSIDE PHD 100 A1 - Operation - 2

Be prepared for the recoil force of the emitted water jet! Ensure that you are standing firmly and that you are holding the gun (A 5) securely, otherwise you could injure yourself or other people.

  • Switch on the pressure washer with the ON / OFF switch (A 5).
  • Pull the lever of the gun ( A 10) to turn on the washer.
  • Hold the switch-on lever of the gun (A 10) until there is no more air in the pressure washer.

PARKSIDE PHD 100 A1 - Operation - 3

Releasing the lever will switch off the washer, but the pressure within the system is retained.

PARKSIDE PHD 100 A1 - Operation - 4

- Lock / unlock the switch-on lever of the gun (10) by depressing the locking button (17).

Lock the switch-on lever to prevent the pressure washer from being inadvertently / accidentally started.

PARKSIDE PHD 100 A1 - Operation - 5

Interrupting operation

  • Release the lever of the gun ( A 10).
  • During prolonged work intervals turn off the washer by its ON / OFF switch (A 5).

Ending operation

• After working with cleaning agents, run the equipment with clean water to completely rinse the cleaning agent from the pipes.
- Release the lever of the gun ( A 10).
- Turn off the pressure by its ON / OFF switch (A 5).
- Turn off the water tap.
- Disconnect the pressure washer from the water mains.
- Pull the lever of the gun (A 10) to vent the pressure existing within the system.
- Disconnect the mains plug.

Using detergents

The washer was designed for operation with a neutral detergent based on a biologically decomposable anionic tenside. Other detergents or chemical substances could impair the safety of the washer and damage it.

PARKSIDE PHD 100 A1 - Using detergents - 1

Fixing the Wheels

The back wheels on the chassis (9) can be fixed in order to secure the pressure washer against undesired rolling away.

  • To do this push the two bolts (16) outwards and downwards.
    The wheels are now no longer able to turn.

• To cancel the wheel fixing, push the two bolts (16) upwards.

F Removing the Chassis

The pressure washer can also be used without the chassis (9).

- Press the release button (18) on the front locking point. Hold the chassis (9) securely in the front area and pull the pressure washer upwards.

At the same time, tilt the pressure washer slightly to the rear.

- To reinstate, insert the device into the rear area of the chassis (9). Push down on the device down and press the release button (18) at the same time. The device clicks into the chassis.

Cleaning and Maintenance

PARKSIDE PHD 100 A1 - Cleaning and Maintenance - 1

Pull out the power plug before every maintenance operation. There is a risk of electrocution or of injury from moving parts.

Cleaning

PARKSIDE PHD 100 A1 - Cleaning - 1

Never direct the water jet against the washer, nor clean the washer under flowing water. This could give rise to the danger of electric shock and damage the washer!

Always keep the washer clean. Do not use any detergents or solvents.

• Always keep the ventilation slots clean and free.

- Only clean the pressure washer with a soft brush or a slightly moist cloth.

- In case a nozzle of the jet tube (12/13) is clogged up, use the nozzle cleaning pin (15) to remove the object from the nozzle.

PARKSIDE PHD 100 A1 - Cleaning - 2

If necessary, take off the water connection with the filter insert (8) and clean the filter insert.

Maintenance

The pressure washer is maintenance free.

PARKSIDE PHD 100 A1 - Maintenance - 1

Ask our service centre to carry out any work that is not described in these instructions. Use only original parts.

Storage

- Drain all the water from the pressure washer. Disconnect the unit from the water supply. Press the On/Off switch (A 5) to turn on the pressure washer for no longer than 1 minute until no more water escapes from the high-pressure connection (A 5). Turn off the unit.

- Protect the pressure washer and its accessories from frost when they have not been completely drained of all water.

- Store the pressure washer and its accessories in a frost-free room.

• To transport or put away the equipment, use only the carrying handle.

- Store the equipment only in a horizontal position in order to protect it from any damage.

Waste Disposal and Environmental Protection

Be environmentally friendly. Return the tool, accessories and packaging to a recycling centre when you have finished with them.

PARKSIDE PHD 100 A1 - Waste Disposal and Environmental Protection - 1

Electric appliances should not be disposed of in the domestic garbage.

Hand the tool in at a recycling centre. The plastics and metal parts can be separated and recycled. Ask your Service Center about this.

We can carry out a waste disposal of your device free of charge.

Guarantee Notes

  • This unit has a guarantee period of 36 months, or 12 months for units used on a commercial basis or for replacement units according to the statutory regulations.
  • Justified guarantee claims should be reported to our Service Centre (see page 57 for telephone & fax no.s, and email address). Our Service Team will tell you more about our complaints handling procedure.
  • Damage due to natural wear and tear, overload or incorrect use is excluded from the guarantee. Certain components are subject to normal wear and tear and are excluded from the guarantee. Inappropriate use will invalidate the warranty.
    • Furthermore, the prerequisite for guarantee services is that the references indicated in the operating instructions regarding cleaning and maintenance

have been adhered to.

- Damage, which has been caused from material or manufacturing faults, will be made good free of charge, by replacement delivery or repair.

This requires that the appliance is returned to our service center undismantled and with proof of purchase and guarantee.

- Repairs, which are not covered by the guarantee, can be carried out for charge by our service center. Our service center will be glad to provide you with a cost estimate.

We can only process devices which have been packaged sufficiently and which have been dispatched with correct stamping.

• Devices sent in freight collect - by bulk freight, express or with other special freight - are not accepted.

• We can carry out a waste disposal of your device free of charge.

Technical data

Pressure Washer ......PHD 100 A1

Mains connection.....230V\~, 50 Hz

Power consumption 1450 W

Mains cable 5 m

Weight (incl. all parts) 6,0 kg

Safety class ....☐ II

Degree of protection IPX5

Inflow temperature t, max. 40°C

Inflow pressure p, max. 0,8 MPa

Operating pressure p 7,0 MPa

Max. permissible pressure p..... 10,0 MPa

Pumping rate, water 5,67 l/min

Max. pumping rate, water ..... 6,67 l/min

Acoustic pressure level

(L_pA) 76,4 dB(A); K_pA = 3,0 dB(A)

Sound power level (LWA)

measured ..... 88,8 dB(A); KWA=3,0 dB(A)

guaranteed 95 dB (A)

Vibration (an) .....0,259 m/s²; K=1,5 m/s²

Technical and optical changes can be carried out in the course of further development without notice. All dimensions, references and information of this instruction manual are therefore without guarantee. Legal claims, which are made on the basis of the instruction manual, cannot thus be considered as valid.

Trouble shooting

Problem Possible cause Remedy
Washer is not operatingON / OFF switch (5) is turned offCheck ON / OFF switch
Damaged power supply cableCheck power supply cable (7) for damage. If necessary have the power supply cable (7) replaced by a qualified electrician.
Mains faultCheck the electrical system for conformity with the data on the rating plate.
Washer does not generate any pressureAir trapped in the pressure washerTurn on the washer with high-pressure hose until bubble-free water flows out of the high-pressure connection (3).
Drop in the water mains pressureCheck the water mains.
Severe pressure fluctuationsHigh-pressure nozzle (13) is dirtyRinse the high-pressure nozzle (13) with water. If necessary clean the nozzle hole with a needle.

Spare Parts Order

When buying parts for the pressure washer, use the service address or fax number given.

Please enter your machine type and the product number of the part you are ordering.

PARKSIDE PHD 100 A1 - Spare Parts Order - 1

Item Description....Product No.

14 Cleaning agent container with nozzle.... 91096764

13 High-pressure nozzle 91096765

1-2 High-pressure hose....91096766

12 Adjustable flat-jet nozzle....91096767

11 Jet lance 91096768

10 Gun 91096769

Sisältö

Grizzly Service-Center ....57

PARKSIDE PHD 100 A1 - Sisältö - 1

Grizzly Service-Center 57

PARKSIDE PHD 100 A1 - Sisältö - 2

Grizzly Service-Center 57

PARKSIDE PHD 100 A1 - Sisältö - 3

Grizzly Service-Center ....57

Exploded view diagram of a motorcycle's internal components with numbered parts and Chinese labels

1 2-11 3 4 5 6 7

informative, informatiivinen, informativ

Grizzly Service-Center

PARKSIDE PHD 100 A1 - Grizzly Service-Center - 1

DES UK Ltd.

Unit B7

PARKSIDE PHD 100 A1 - Grizzly Service-Center - 2

Oxford Street Industrial Park

Vulcan Road

Bilston, West Midlands WV14 7LF

Tel.: 0870 787 6177

Tel. from Ireland: 0044 870 787 6177

Fax: 0870 7876168

Fax from Ireland: 0044 870 787 6168

E-mail: grizzly@deslimited.com

PARKSIDE PHD 100 A1 - Grizzly Service-Center - 3

Railmit Oy

Petäjäksentie 19

26100 Rauma

Tel.: 02822 2887

Fax: 01029 30263

E-mail: pekka.railio@railmit.fi

PARKSIDE PHD 100 A1 - Grizzly Service-Center - 4

Grizzly Service Sverige

Tel.: 020 799335

E-mail: service.sverige@grizzly.biz

PARKSIDE PHD 100 A1 - Grizzly Service-Center - 5

Grizzly Service Denmark

Tel.: 7028 8811

E-mail: service.danmark@grizzly.biz

PARKSIDE PHD 100 A1 - Grizzly Service-Center - 6

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PARKSIDE

Model : PHD 100 A1

Category : Pressure washer