USER MANUAL EWH 15 VR1.5 TEKA
natural_image
White water heater with a dial indicator and 'Ieka' logo, no visible text or symbols on the body.

| Modelo | A | B | C | D | E | F | G | H | I |
| EWH 15 VR1.5 | 100 | 86.5 | 384 | 330.5 | 198 | 104.5 | 115 | 340 | 360 |
| EWH 30 VR1.5 | 100 | 86.5 | 594 | 568.5 | 198 | 141 | 257 | 340 | 360 |
| EWH 50 VR1.5 | 100 | 141.5 | 567 | 524.5 | 198 | 141 | 176 | 450 | 470 |
| EWH 80 VR1.5 | 100 | 141.5 | 796 | 746.5 | 198 | 141 | 297 | 450 | 470 |
| EWH 100 VR1.5 | 100 | 141.5 | 961 | 911.5 | 198 | 141 | 447 | 450 | 470 |
| Modelo | A B | C D E F | G H I | ||||||
| EWH 15 VR1.5 | 100 | 86.5 | 384 | 330.5 | 198 | 104.5 | 115 | 340 | 360 |
| EWH 30 VR1.5 | 100 | 86.5 | 594 | 568.5 | 198 | 141 | 257 | 340 | 360 |
| EWH 50 VR1.5 | 100 | 141.5 | 567 | 524.5 | 198 | 141 | 176 | 450 | 470 |
| EWH 80 VR1.5 | 100 | 141.5 | 796 | 746.5 | 198 | 141 | 297 | 450 | 470 |
| EWH 100 VR1.5 | 100 | 141.5 | 961 | 911.5 | 198 | 141 | 447 | 450 | 470 |
Sealed Storage Electric Water Heater
EWH 15 VR1.5
EWH 30 VR1.5
EWH 50 VR1.5
EWH 80 VR1.5
EWH 100 VR1.5
Read the Manual
before using and installing
We would like to sincerely thank you for selecting our electric water heater. Please read this manual carefully before use and the methods for the installation and use of this electric water heater, to make full use of its excellent performances.
WARNING
● Before installing this water heater, check and confirm the earth electrode on the socket is reliably grounded, without electricity. Otherwise, the electric water heater can not be installed or used.
- Do not use mobile sockets.
- Incorrect installation and use of this electric water heater may result in serious injuries to human bodies and losses of property.
Contents
● Performance characteristics.... (1)
- Specifications.... (2)
- Brief introduction of product structure....(2)
● Methods of installation.... (3)
● Methods of use.... (5)
● Cautions.... (5)
● Maintenance.... (7)
● Failures and treatment.... (7)
● Wiring diagram.... (8)
Performance characteristics
- Total automatic control: automatic addition of cold water, automatic heating.
- Three-fold safety protection: multiple safety protection devices, such as dry heating protection, extra-temperature protection, high hydraulic pressure protection, etc., safe and reliable.
- Sapphire enamel inner container: manufactured by using advanced electrostatic dry method enamel technique, antirust, corrosion-proof, incrustation-resistant, leak-prevention, with longer lifetime.
- Heating pipes designed with low thermal load: safe and reliable, with longer lifetime.
- Equipped with corrosion-proof and incrustation-retardant equipment: durable products.
- Thickened urethane integral foaming: good thermal insulation effect, energy efficient and electricity saving.
- Imported temperature controller: accurate and reliable control of temperature.
- Adjustable range of water temperature from 30 to 75°C.
- Simple operation and easy use.

Specifications
| Model | Volume (L) | Rated power (W) | Rated voltage (ACV) | Rated pressure (MPa) | Max of water temperature (°C) | Electric type | Waterproof grade |
| EWH 15 VR1.5 | 150015 | 220 | 0.75 | 75 | Type I | IPX4 | |
| EWH 30 VR1.5 | 30 | 1500 | 220~240 | 0.75 | 75 | Type I | IPX4 |
| EWH 50 VR1.5 | 50 | 1500 | 220~240 | 0.75 | 75 | Type I | IPX4 |
| EWH 80 VR1.5 | 80 | 1500 | 220~240 | 0.75 | 75 | Type I | IPX4 |
| EWH 100 VR1.5 | 100 | 1500 | 220~240 | 0.75 | 75 | Type I | IPX4 |

Brief introduction of product structure


Methods of installation
Note: Please make sure to use the accessories provided by our company to install this electric water heater. This electric water heater can not be hung on the support until it has been checked that it is firm and reliable. Otherwise, the electric water heater may face from the wall, resulting in damage of the heater, even serious accidents or injuries to people. When determining the locations of the bolt holes, it shall be ensured that there is a clearance not less than 0.2m on the right side of the electric heater, to facilitate the maintenance of the heater, if necessary.
1. Installation of the main machine

| Model | A B C D E F G H I | ||||||||
| EWH 15 VR1.5 | 100 | 86.5 | 384 | 330.5 | 198 | 104.5 | 115 | 340 | 360 |
| EWH 30 VR1.5 | 100 | 86.5 | 594 | 568.5 | 198 | 141 | 257 | 340 | 360 |
| EWH 50 VR1.5 | 100 | 141.5 | 567 | 524.5 | 198 | 141 | 176 | 450 | 470 |
| EWH 80 VR1.5 | 100 | 141.5 | 796 | 746.5 | 198 | 141 | 297 | 450 | 470 |
| EWH 100 VR1.5 | 100 | 141.5 | 961 | 911.5 | 198 | 141 | 447 | 450 | 470 |
- This electric water heater should be installed in a solid wall. If the strength of the wall can't bear theweight equalling twice. The total weight of the heater fully filled with water, it will be necessary to install a special support.
- After selecting a proper location, determine the positions of the two installation holes used for expansion bolts with hook (determined according to the specification of the product you select). Make two holes in the wall with the right depth by drilling the correct size matching the expansion bolts attached, insert the screws, place the hook upwards, tighten the nuts so that they are firmly fixed, and then hang the electric water heater on it (see Fig.2). Expansion bolt

- Install the supply socket in the wall. The requirements for the socket are as follows: 250V/10A, single phase, three electrodes. It is recommended to place the socket on the right above the heater. The height from the socket to the ground shall not be less than 1.8m (see Fig.3).
The heater can be installed, anywhere in the house not exposed to direct sunlight or rain. However, in order to reduce the pipeline heat losses, the installation position of the heater shall be closed to the location for use of water as near as possible.
2. Connection of pipelines
-
The dimension of each pipe part is G1/2.
-
Connection of one-way safety valve: install the one-way safety valve attached with the machine at the water inlet of the main machine.(Pay attention to keep the installed drainage flexible pipes of the safety valve sloping downwards and connected with the atmosphere.)
-
In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided with the machine must be added at the end of the threads (see Fig.3).

- If the users want to make a multi-way supply system, refer to the method shown in Fig.4 for connection of the pipelines.


Methods of use
- First, open any of the outlet valves at the outlet of the water heater, then, open the inlet valve. The electric water heater begins to be filled with water. When there is water coming out of the outlet valve normally, it implies that the heater has been fully filled with water, and the outlet valve can be closed.
Note: During normal operation, the inlet valve shall be set in the status of "open".
- Insert the supply plug into the socket, the two indicator lights will be on at the same time..
- This machine can automatically control the temperature. When the water temperature inside the machine has reached the set temperature (It is set to 75^ ), it will be turned off automatically, and step into the status of thermal insulation; when the water temperature is decreased to a certain point, it will be turned on automatically to restore the heating, and the use of hot water will not be interrupted. When the heater is switched off automatically, the heating indicator will turn off.

Cautions
-
The supply socket must be earthed reliably. The rated current of the socket shall not be lower than 10A. The socket and plug shall be kept dry to prevent electric leakage. Inspect frequently whether the plugs are well plugged in the socket. Inspect method is as follows: insert the power supply plug into the socket, after using for half an hour, shut down the unit and pull the plug out, and inspect the plug in case it scalds your hand. If tempeature is over 50^ , please plug in another socket. to avoid the plug being damaged, fire or other personnel accidents result from badcontact.
-
For the places or the wall where the water may splash, the installation height of the socket shall not be lower than 1.8m.
-
The wall in which the electric water heater is installed shall be able to bear the weight equalling twice the weight of the heater fully filled with water without distortion or cracks. Otherwise, other strengthening measures should be adopted.
-
The one-way safety valve attached to the machine must be installed to the cold water inlet of this machine (see Fig.5).

- For the first use (or the first use after maintenance or cleaning), the heater can not be switched on until it has been (fully) filled with water. When filling with water, at least one of the outlet valves at the outlet of the heater must be opened to release the air. This valve can be closed after the heater has been (fully) filled with water.
- During the heating, there may be drops of water dripping from the pressure release hole of the one-way safety valve. This is a normal phenomenon. If there is a large amount of water leaking, please contact the professional maintenance personnel for repair. This pressure release hole shall, under no circumstances, be blocked; otherwise, the heater may be damaged, even resulting in safety accidents.
- The drainage pipe connected to the pressure release hole must be kept sloping downwards.
- Since the water temperature inside the heater can reach up to 75^ C, the hot water must not be exposed to people when it is initially used. Adjust the water to a reasonable temperature to avoid scalding..
- In order to drain off the water inside the inner container, it can be drained off from the exit port (Twist the thread screw of the exit port), and it can also be drained off from the one-way safety valve (Twist the thread screw off the one-way safety valve, and lift the drain handle upwards).
- If the flexible power supply cord is damaged, the special supply cord provided by the manufacturer must be used, and replaced by the professional maintenance personnel.
- If any parts or components of this electric water heater are damaged, please contact the professional maintenance personnel for repair, and use the special spare parts and components provided by our company.

pressure release hole
(Fig.6)

Maintenance
-
Check the power supply plug and socket frequently to make sure that they have good, reliable contact and are well grounded without overheating.
-
If the heater is not going to be used for a long time, especially in the regions with low temperatures (lower than 0^ ), in order to prevent the heater being damaged due to the freezing of water in the inner container, the water inside the heater shall be drained away (refer to Item 9, Cautions of this manual for the method to drain away the water inside the inner container).
-
The recommended water hardness for an optimum working performance of the water heater should not exceed 120 mg/l of CaCo3 (Calcium Carbonate). In case of exceeding this quantity, it is recommended to use alternative decalcifying systems (You can check your local water hardness in the Water Board of you local Town Hall.) Should there be any failures due to the deposits originated by the water quality, will not be covered by the guarantee.
-
To guarantee the long-term durability and efficiency of your water heater, it is recommended to clean its inner tank and the deposits in the heating components on a regular basis.
-
It is also recommended to check the magnesium anode periodically (minimum once a year or every six months depending on the water hardness).
-
If the magnesium anode of your water tank is worn out due to the deposits originated by the water quality, the After Sales Service will have to replace it by a new one. The cost of the materials of the replacement of the magnesium anode will be covered within the guarantee period, however, the cost of the workforce or services for this replacement will not be included.
-
It is recommended to clean the surface of the water heater with soapy water, never use abrasive products or solvents.
-
During the guarantee period, the maintenance will be done by Teka's Official After Sales Service. Any services undertaken by non-Teka Official After Sales services will be excluded from the guarantee.
| Types of water | mg/l | ^ fH | ^ dH | ^ eH |
| Soft water | ≤17 | ≤1.7 | ≤0.95 | ≤1.19 |
| Slightly hard water | ≤60 | ≤6.0 | ≤3.35 | ≤4.20 |
| Moderately hard water | ≤120 | ≤12.0 | ≤6.70 | ≤8.39 |
| Hard water | ≤180 | ≤18.0 | ≤10.05 | ≤12.59 |
| Very hard water | >180 | >18.0 | >10.05 | >12.59 |

Failures and treatment
| Failures | Reasons | Treatment |
| The heating indicator light is off. | Failures of the temperature controller. | Contact with professional staff for repair. |
| No water coming out of the hot water outlet. | 1. The running water supply is cut off.2. The hydraulic pressure is too low.3. The inlet valve running water is not open. | 1. Wait for restoration of running water supply.2. Use the heater again when the hydraulic pressure is increased.3. Open the inlet valve running water. |
| The water temperature is too high. | Failures of the temperature control system. | Contact with professional staff for repair. |
| Water leak | Seal problem of the joint of each pipe. | Seal up the joints. |

Wiring diagram

flowchart
graph TD
A["Temperature limiter"] --> B["Thermostat"]
B --> C["Switch"]
C --> D["Heating element"]
D --> E["Power indicator light"]
E --> F["Yellow/Green"]
G["Brown"] --> H["L"]
I["Blue"] --> J["N"]
K["0"] --> L["Switch"]
M["0"] --> N["Switch"]
O["0"] --> P["Switch"]
Q["0"] --> R["Switch"]
S["0"] --> T["Switch"]

Produce information with EU regulation
he electrical storage water heater EWH 15 VR1.5 of the company TEKA Industrial, S.A. was tested with a declared load profile of the size "XXS"
The product fulfills and corresponds to the requirements of the commission regulatory standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of 1wh=34%
that correspond to the water heating efficiency class\$”
In accordance with Annex II Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report in respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
Electricity consumption Q_elec , water heating energy efficiency _wh and mixed water at 40°C (V40)
| Description Parameter Value Unit | |||
| k-Value | k 0.23 | ||
| Smart control compliance | smart | 0 | |
| Smart control factor | SCF | 0 | |
| Conversion coefficient | CC | 2.5 | |
| Ambient correction term Q | cor -0.27 | 2 kWh | |
| Referenct energy | Q_ref | 2.1 | kWh |
| Useful energy content | Q_H2O | 2.297 | kWh |
| Correction ratio of reference and useful energy | Q_ref/Q_H2O | 0.914 | kWh |
| Daily electricity consumption (measured) | Q_test\_elec | 2.807 | kWh |
| Water temperature at the beginning of the 24h measurement cycle | T3 | 77.7 | °C |
| Water temperature at the end of the 24h measurement cycle | T5 | 77.3 | °C |
| Storage volume | M_act | 15.2 | kg |
| Storage volume | C_act | 15.2 L | |
| Daily electricity consumption (corrected) | Q_elec | 2.573 | kWh |
| Water heating energy efficiency | n_wh | 34.1 | |
| Annual Electricity Consumption | AEC | 541 | kWh |
| Water heating energy efficiency class | B | ||
| Description | Parameter | Value | Unit |
| Water temperature without tapping | T_set | 79.1 | °C |
| Average water temperature of outlet warm water | _p' | 65.8 | °C |
| Average water temperature of inlet cold water | _c | 10.8 | °C |
| Normalised value of the average temperature | _p | 65.6 | °C |
| Volume that delivered water of at least 40°C | V_40exp | 14 | L |
| Calculated volume that delivered hot water of at least 40°C | V_40 | 26 | L |
he electrical storage water heater EWH 30 VR1.5 of the company TEKA Industrial, S.A. was tested with a declared load profile of the size "S"
The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of f_wh = 33%
that correspond to the water heating efficiency class"
In accordance with Annex II Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report in respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
Electricity consumption Q_dec , water heating energy efficiency _wh and mixed water at 40°C (V40)
| Description Parameter Value Unit | |||
| k-Value | k 0.23 | ||
| Smart control compliance | smart | 0 | |
| Smart control factor | SCF | 0 | |
| Conversion coefficient | CC | 2.5 | |
| Ambient correction term Q | cor -0.342 kWh | ||
| Referenct energy | Q_ref | 2.1 | kWh |
| Useful energy content | Q_H2O | 2.266 | kWh |
| Correction ratio of reference and useful energy | Q_ref/Q_H2O 0.927 | kWh | |
| Daily electricity consumption (measured) | Q_test\_elec | 2.960 kWh | |
| Water temperature at the beginning of the 24h measurement cycle | T3 | 75.9 | °C |
| Water temperature at the end of the 24h measurement cycle | T5 77.4 | °C | |
| Storage volume | M_act | 29.6 | kg |
| Storage volume | C_act | 29.6 L | |
| Daily electricity consumption (corrected) | Q_elec | 2.695 kWh | |
| Water heating energy efficiency | n_wh | 32.8 | |
| Annual Electricity Consumption | AEC | 562 | kWh |
| Water heating energy efficiency class | C | ||
| Description | Parameter | Value | Unit |
| Water temperature without tapping | T_set | 76.4 | °C |
| Average water temperature of outlet warm water | _p' | 67.4 | °C |
| Average water temperature of inlet cold water | _c | 10.4 | °C |
| Normalised value of the average temperature | _p | 67.4 | °C |
| Volume that delivered water of at least 40°C | V_40exp | 25.6 | L |
| Calculated volume that delivered hot water of at least 40°C | V_40 | 49 | L |
he electrical storage water heater EWH 50 VR1.5 of the company TEKA Industrial, S.A. was tested with a declared load profile of the size "M"
The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of f_wh=37%
that correspond to the water heating efficiency class"
In accordance with Annex II Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report in respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
Electricity consumption Q_dec , water heating energy efficiency _wh and mixed water at 40°C (V40)
| Description Parameter Value Unit | |||
| k-Value | k 0.23 | ||
| Smart control compliance | smart | 0 | |
| Smart control factor | SCF | 0 | |
| Conversion coefficient | CC | 2.5 | |
| Ambient correction term Q | cor -0.357 kWh | ||
| Referent energy | Q_ref | 5.845 | kWh |
| Useful energy content | Q_H2O | 6.234 | kWh |
| Correction ratio of reference and useful energy | Q_ref/Q_H2O 0.938 | kWh | |
| Daily electricity consumption (measured) | Q_test\_elec | 6.944 kWh | |
| Water temperature at the beginning of the 24h measurement cycle | T3 | 75.3 | °C |
| Water temperature at the end of the 24h measurement cycle | T5 76.1 | °C | |
| Storage volume | M_act | 50.8 | kg |
| Storage volume | C_act | 50.8 L | |
| Daily electricity consumption (corrected) | Q_elec | 6.466 kWh | |
| Water heating energy efficiency | n_wh | 37.0 | |
| Annual Electricity Consumption | AEC | 1389 | kWh |
| Water heating energy efficiency class | C | ||
| Description | Parameter | Value | Unit |
| Water temperature without tapping | T_set | 76.5 | °C |
| Average water temperature of outlet warm water | _p' | 69.5 | °C |
| Average water temperature of inlet cold water | _c | 10.2 | °C |
| Normalised value of the average temperature | _p | 69.4 | °C |
| Volume that delivered water of at least 40°C | V_40exp | 40.4 | L |
| Calculated volume that delivered hot water of at least 40°C | V_40 | 80 | L |
he electrical storage water heater EWH 80 VR1.5 of the company TEKA Industrial, S.A. was tested with a declared load profile of the size "M"
The product fulfills and corresponds to the requirements of the commission regulatory standards (No 814/2013) for electrical storage water heater and achieved a wa heating energy efficiency of 1wh=35%
that correspond to the water heating efficiency class”
In accordance with Annex II Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report in respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
Electricity consumption Q_ec , water heating energy efficiency _wh and mixed water at 40°C (V40)
| Description | Parameter Value Unit | ||
| k-Value | k 0.23 | ||
| Smart control compliance | smart | 0 | |
| Smart control factor | SCF | 0 | |
| Conversion coefficient | CC | 2.5 | |
| Ambient correction term | Q_cor -0.624 kWh | ||
| Referenct energy | Q_ref | 5.845 kWh | |
| Useful energy content | Q_H2O | 6.182 kWh | |
| Correction ratio of reference and useful energy | Q_ref/Q_H2O 0.945 | kWh | |
| Daily electricity consumption (measured) | Q_test\_elec | 7.366 kWh | |
| Water temperature at the beginning of the 24h measurement cycle | T3 | 75 | °C |
| Water temperature at the end of the 24h measurement cycle | T5 | 75.6 | °C |
| Storage volume | M_act | 80.3 | kg |
| Storage volume | C_act | 80.3 | L |
| Daily electricity consumption (corrected) | Q_elec | 6.930 | kWh |
| Water heating energy efficiency | n_wh | 35.0 | |
| Annual Electricity Consumption | AEC | 1467 | kWh |
| Water heating energy efficiency class | D | ||
| Description | Parameter | Value | Unit |
| Water temperature without tapping | T_set | 75 | °C |
| Average water temperature of outlet warm water | '_p | 71 | °C |
| Average water temperature of inlet cold water | _c | 10.2 | °C |
| Normalised value of the average temperature | _p | 71 | °C |
| Volume that delivered water of at least 40°C | V_40exp | 68.8 | L |
| Calculated volume that delivered hot water of at least 40°C | V_40 | 140 | L |
he electrical storage water heater EWH 100 VR1.5 of the company TEKA Industrial, S.A. was tested with a declared load profile of the size "L"
The product fulfills and corresponds to the requirements of the commission regulatory standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of 1wh=36%
that correspond to the water heating efficiency class\$”
In accordance with Annex II Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report in respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label.
Electricity consumption Qec, water heating energy efficiency _wh and mixed water at 40^ (V40)
| Description Parameter Value Unit | |||
| k-Value | k 0.23 | ||
| Smart control compliance | smart | 0 | |
| Smart control factor | SCF | 0 | |
| Conversion coefficient | CC | 2.5 | |
| Ambient correction term Q | cor -0.861 kWh | ||
| Referenct energy | Q_ref | 11.655 kWh | |
| Useful energy content | Q_H2O | 12.088 kWh | |
| Correction ratio of reference and useful energy | Q_ref/Q_H2O 0.964 | kWh | |
| Daily electricity consumption (measured) | Q_test\_elec | 13.653 kWh | |
| Water temperature at the beginning of the 24h measurement cycle | T3 | 74.4 | °C |
| Water temperature at the end of the 24h measurement cycle | T5 74.5 | °C | |
| Storage volume | M_act | 100.1 | kg |
| Storage volume | C_act | 100.1 L | |
| Daily electricity consumption (corrected) | Q_elec | 13.153 | kWh |
| Water heating energy efficiency | n_wh | 36.4 | |
| Annual Electricity Consumption | AEC | 2813 | kWh |
| Water heating energy efficiency class | D | ||
| Description | Parameter | Value | Unit |
| Water temperature without tapping | T_set | 75.1 | °C |
| Average water temperature of outlet warm water | _p' | 69.5 | °C |
| Average water temperature of inlet cold water | _c | 10.1 | °C |
| Normalised value of the average temperature | _p | 69.5 | °C |
| Volume that delivered water of at least 40°C | V_40exp | 82.1 | L |
| Calculated volume that delivered hot water of at least 40°C | V_40 | 163 | L |

DESCRIPTION TO ANNEX I
(1)supplier's name or trade mark
(2) supplier's model identifier
(3) the declared load profile, expressed by the appropriate letter and typical usage in accordance with Table 3 of Annex VII
(4) the water heating energy efficiency class of the model, determined in accordance with point 1 of Annex II
(5) the water heating energy efficiency in %, rounded to the nearest integer
(6) the annual electricity consumption in KWh in terms of final energy and/or the annual fuel consumption in GJ in terms of GCV, rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII
(7) the thermostat temperature settings of the water heater, as placed on the market
(8) the daily electricity consumption Q elec in KWh, rounded to three decimal places
(9) the declared load profile, expressed by the appropriate letter in accordance with Table 1 of this Annex
(10) the mixed water at 40°C V40 in litres, rounded to the nearest integer
(11) maximum temperature of the thermostat
(12) 'out of the box-mode' is the standard operating condition, setting or mode set by the manufacturer at factory level, to be active immediately after the appliance installation, suitable for normal use by the end-user according to the water tapping pattern for which the product has been designed and placed on the market
(13) the water heating energy efficiency in %, rounded to one decimal place
(14) All specific precautions for assembly, installation and maintenance are described in the operating and installation instructions. Read and follow the operating and installation instructions.
(15) All of the data that is included in the product information was determined by applying the specifications of the relevant European directives. Differences to product information listed elsewhere may result in different test conditions. Only the data that is contained in this product information is applicable and valid.
Teka Subsidiaries
| Country Subsidiary | Address | City | Phone |
| AustriaKüppersbusch Austria | Eitnergasse, 13 | 1231 Wien | +43 18 668 022 |
| BelgiumKüppersbusch Belgium S.P.R.L. | Doomveld Industrie, Asse 3, No. 11 - Boite 7 | 1731 Zellik | +32 24 668 740 |
| BulgariaTeka Bulgaria EOOD | Blvd. "Tsarigradsko Shosse" 135 | 1784 Sofia | +359 29 768 330 |
| ChileTeka Chile S.A. | Avd El Retiro Parque los Maitenes, 1237. Parque Enea | Pudahuel, Santiago de Chile | + 56 24 386 000 |
| ChinaTeka International Trading (Shanghai) Co. Ltd. | 6/F. Datong Business Center, No. 369 Fuxing Middle Rd. | 200025 Shanghai | +86 2 153 076 901 |
| Czech RepublicTeka CZ S.R.O. | V Holesovickách, 593 | 182 00 Praha 8 - Liben | +420 284 691 940 |
| EcuadorTeka Ecuador S.A. | Parque Ind. California 2, Via a Daule Km 12 | Guayaquil | +593 42 100 311 |
| Great BritainTeka Products Ltd. | 177 Milton Park | OX14 4SE Milton, Abingdon | +44 1 235 861 916 |
| GreeceTeka Hellas A.E. | Thesi Roupaki - Aspropyrgos | 193 00 Athens | +30 2 109 760 283 |
| HungaryTeka Hungary Kft. | Bajcsy Zsilinszky u. 53 | 1065 Budapest | +36 13 542 110 |
| IndonesiaPT Teka Buana | Jalan Menteng Raya, Kantor Taman A9 Unit A3 | 12950 Jakarta | +62 215 762 272 |
| MalaysiaTeka Küchentechnik (Malaysia) Sdn Bhd | 10 Jalan Kartunis U1/47, Tomasya Park, Off Glenmarie | 40150 Shah Alam, Selangor Darul Ehsan | +60 376 201 600 |
| MexicoTeka Mexicana S.A. de C.V. | Ferrocarril 200, Esquina Norte 29, Col. Moctezuma | 15500 Mexico D.F. | +52 5 551 330 493 |
| MoroccoTeka Maroc S.A. | 73, Bd. Slimane, Depôt 33, Route de Ain Sebaa | Casablanca | +212 22 674 462 |
| PolandTeka Polska Sp. ZO.O. | ul. 3-go Maja 8 / A2 | 05-800 Pruszków | +48 227 383 270 |
| PortugalTeka Portugal S.A. | Estrada da Mota - Apdo 533 | 3834-909 Ilhavo, Aveiro | +35 1 234 329 500 |
| RomaniaS.C. Teka Küchentechnik Romania S.R.L. | Sevastopol str., no 24, 5th floor, of. 15 | 010992 Bucharest Sector 1 | +40 212 334 450 |
| Russia/PоссияTeka Rus LLC/OOO "Teka Pyc" | ул.Баркляя, д.6, стр.3, оф.402 | 121087 Россия, Москва | +7 4 956 450 064 |
| SingaporeTeka Singapore PTE Ltd | Clemenceau Avenue, 83, 01-33/34 UE Square | 239920 Singapore | +65 67 342 415 |
| SpainTeka Industrial, S.A. | C/ Cajo,17 | 39011 Santander | +34 942 355 050 |
| ThailandTeka (Thailand) Co. Ltd. | 364/8 Sn-Ayuttaya Road, Phayathai, Ratchatavee | 10400 Bangkok | +66 -26 424 888 |
| TurkeyTeka Teknik Mutfak Aletleri Sanayi Vo | Büyükdere Cad. 24/13 | 80290 Mecidiyeköy, Istanbul | +90 2 122 883 134 |
| UkraineTeka Ukranie LLC | 86-e, Bozhenko Str .2nd floor,4th entrance | 03150 Kyiv | +380 444 960 680 |
| United Arab EmiratesTeka Middle East Fze | Building LOB 16, Office 417 | P.O. Box 18251 Dubai | +971 48 872 912 |
| United Arab EmiratesTeka Küchentechnik U.A.E LLC | Bin Khedia Centre | P.O. Box 35142 Dubai | +971 42 833 047 |
| VenezuelaTeka Andina S.A. | Ctra. Petare-Santa Lucia, km 3 (El Limoncito) | 1070 Caracas | +58 2 122 912 821 |
| VietnamTEKA Vietnam Co., Ltd. | 803 Dai Minn Convention Tower, 8th Floor | 77 Hoang Van Thai, District 7, Ho Chi Minh | +84 854 160 646 |