SOLAC IP1100 - IPL hair remover

IP1100 - IPL hair remover SOLAC - Free user manual and instructions

Find the device manual for free IP1100 SOLAC in PDF.

📄 33 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice SOLAC IP1100 - page 17
View the manual : English EN Español ES Português PT
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeIPL Hair Remover
ModelSolac IP1100
TechnologyReactive Pulsed Light (RPL™) - Home Use IPL
Light Spectrum475 nm to 1200 nm
Energy Flux5 J/cm²
Energy Levels3 (levels 1-3)
Treatment Window Size3 cm²
Pulse Repetition Rate1 pulse every 3 seconds
Dimensions135 × 45 × 75 mm
Weight220 g (7.8 oz)
Power SupplyExternal: Input 100–240 VAC, 50–60 Hz; Output 12 V, 1.8 A
Skin Tone SensorAutomatic built-in sensor; blocks treatment on dark or tanned skin (Fitzpatrick V+ and VI)
Full Contact DetectionOnly emits pulse when treatment window is in full contact with skin
Intended Body AreasLegs, arms, underarms, bikini line, back, shoulders, chest, and facial areas below cheek line
Hair TypesBest on dark brown to black hair; limited on white, grey, or blond
Operating Temperature10°C to 40°C (50°F to 104°F)
Storage Temperature-10°C to 70°C (14°F to 158°F)
CleaningWipe treatment window with a dry, clean cloth after each session
IndicatorsGreen (standby/ready), orange (no contact/end-of-life), red (blocked skin tone/fault)
Lamp LifeApproximately 100,000 pulses; end-of-life indicated by steady red light
Safety CertificationsComplies with EU Low Voltage, EMC, RoHS, and Ecodesign directives

Frequently Asked Questions - IP1100 SOLAC

How does Solac IP1100 hair removal work?
It uses Intense Pulsed Light (IPL) technology. The light is absorbed by melanin in the hair, generating heat that damages the hair follicle, reducing growth.
Who can use this device?
Women and men aged 18+ with skin types I to IV (Fitzpatrick scale). Not for naturally dark skin (type V/VI) or tanned skin, as it may cause burns.
How often should I treat?
Body hair: every 2 weeks for first 4 treatments, then every 4 weeks. Facial hair: every 2 weeks for first 5 treatments, then every 4 weeks. Maintenance as needed.
Can I use it on my face?
Yes, only below the cheek line (upper lip, chin, jaw, cheeks, neck). Never around eyes or eyebrows due to risk of eye injury. Use energy level 1-2 only.
Why does the device not flash?
Common causes: treatment window not in full contact with skin, skin is too dark or tanned, or an error. Ensure skin is clean, dry, and shaved, and that the sensor is not blocked.
How should I prepare my skin?
Shave the area, then clean and dry skin thoroughly. Avoid alcohol, perfumes, or acetone one hour before use. Do not wax or pluck between treatments.
Is it safe?
Yes, with built-in skin tone sensor and full contact detection. However, avoid use on moles, tattoos, damaged skin, or while pregnant. Always perform a patch test 48 hours prior.
What side effects are possible?
Minor: temporary redness, stinging, or heat sensation. Rare: burns, pigmentation changes. If severe redness or blistering occurs, stop use and consult a doctor.
How do I clean and store the device?
Unplug and wipe treatment window with a dry cloth. Store in a dry place at -10 to 70°C. Keep away from water and do not immerse.
How long before I see results?
Initial results may appear in 3-4 weeks. Hair will shed gradually. Multiple sessions are needed for permanent reduction, typically 8-12 treatments depending on hair type.

User questions about IP1100 SOLAC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your IPL hair remover in PDF format for free! Find your manual IP1100 - SOLAC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IP1100 by SOLAC.

USER MANUAL IP1100 SOLAC

natural_image White and pink medical device with 'sOLac' branding, no visible text or symbols on body

EPIL

INSTRUCCIONES DE USO

EPIL

INSTRUCTIONS FOR USE

EPIL

INSTRUÇÕES DE USO

solac

SAFETY ADVICE AND WARNINGS....8

CONSELHOS DE SEGURANÇA E AVISOS....13

ESPAÑOL

Qué es epil Mini 17

Modo de uso 23

What is epil Mini 31

Instructions 36

Recommended treatment protocol 39

Post-treatment care 43

Cleaning and troubleshooting 43

Device specification parameters 45

PORTUGUÉS

Que es epil Mini 47

Many thanks for choosing to purchase a SOLAC brand product.

Thanks to its technology, design and operation and the fact that it exceeds the strictest quality standards, a fully

satisfactory use and long product life can be assured.

SAFETY ADVICE AND WARNINGS

  • Read these instructions carefully before switching on the appliance and keep them for future reference. Failure to follow and observe these instructions may result in an accident.
    This appliance can be used by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • This appliance is not a toy. Children should be supervised to ensure that they do not play with the appliance.
  • Cleaning and user maintenance shall not be made by children unless they are supervised.
  • The appliance cannot be used by person under the age of 18.

Do not open or repair the device as it may expose you to dangerous electrical components which may cause serious bodily damage.
- Do not place, store or use near bathtubs, showers, basins or other vessels containing water as this may cause severe electrocution.
- Do not leave unattended while plugged into the electricity as it may lead to electrocution risk.
- Never look directly at the light coming from the treatment window as it may cause eye injury.
- Never use flammable liquids such as alcohol, perfumes, sanitizers or acetone to clean the skin one hour before use; it may cause burning of the skin.

EN

  • Do not use the device if is not working properly, appears damaged or broken.
  • Do not use the device if the cord or plug is damaged.
    Do not use the device if you see or smell smoke.
  • Do not use the device if the outer shell is damaged or loose.
  • Do not use the device if lamp or treatment window is damaged, or missing.
  • Do not use the device if optical skin tone sensor is cracked, or broken.
  • Do not use the device if it becomes damp or wet.
    Only use the appliance with the specific power supply unit, provided with the appliance.
  • If the connection to the mains has been damaged, it must be replaced, take the appliance to an authorised technical support service. Do not attempt to disas-

semble or repair the appliance by yourself in order to avoid a hazard.

Do not use on naturally dark skin.
Do not use if you are pregnant or with a slight chance of being pregnant or nursing.
Do not use if you have skin cancer or on areas at risk of malignancy or if you have received radiation therapy or chemotherapy within the past 3 months.
- Do not use if you suffer from epilepsy.
Do not use on damaged or broken skin or if you have history of herpes or psoriasis outbreak in the treatment area since it can result is serious effects.
- Do not use if you suffer from ke- loid scar formation.
Do not use if you have been taking Tetracycline antibiotics and/or medication with the following active ingredients within the last

SOLAC IP1100 - EN - 1

SOLAC IP1100 - EN - 2

two weeks: Retinoid acid, Retina-A, Vitamin A such as Accutane as it is considered to be a photo-sensitive drug and may result in serious skin injury.

Do not use if you are photosensitive or have other diseases related to light sensitivity as it may lead to serious injury.

Do not use if you suffer from severe or decompensated metabolic conditions, such as diabetes since it can cause a greater risk of delayed healing and infection in the case of an adverse effect.
- Do not use if you has a skin peel or other skin resurfacing procedure within the last 8 weeks as it may result in stimulation of pigmentation.
Do not use on face areas above the cheek line or around eyes, eyebrows and eyelashes as this could cause serious eye damage.

  • Do not use if you have an active implant such as pacemaker, insulin pump or similar devices since it may cause interference.
  • Do not use on tanned skin or after sun exposure as this can cause serious burns or skin injury. Avoid sun exposure for 4 weeks prior each treatment.
  • Do not use if you have dark brown or black spots such as freckles, birth marks, around nipples, moles or blisters on the area to be treated.
  • Do not use on mucous membranes such as nostrils, lips of the mouth, eyelids, ears, genital area and the anus as it may lead to serious injury.
  • Do not use if you have piercing or any metal such as earrings or jewellery on the area to be treated as it may cause burns.
  • Do not use if you have tattoos or permanent make up on the area

to be treated.

Avoid more than 15 minutes of sun exposure for at least 2 weeks post treatment. If during these 2 weeks you treated skin area is exposed to sunlight, make sure to apply SPF30 or higher sunscreens.
- Do not treat the same area of skin more than once per treatment as it may causes skin irritation.
NOTE: If you have undergone any other aesthetic procedures or have any uncertainty regarding potential side effects, consult your physician before use the appliance.

POSSIBLE SIDE EFFECTS:

- When using the appliances according to the instructions for use, side effects are rare. However, every aesthetic procedure including the usage of home-use devices may cause some degree of side effects. Therefore, it is important that you understand and accept the risk and complications that can occur with pulsed light hair removal system: Ensure that the voltage indicated on the rating label matches the mains voltage before plugging in the appliance.

SOLAC IP1100 - POSSIBLE SIDE EFFECTS: - 1

DEGREE OF SIDE EFFECTSSIDE EFFECTS
Minor - Skin irritation- Skin redness- Skin sensitivity
Rare - Skin burns- Scarring- Pigment changes- Encositive redness and swelling
Extremely rare - Infection- Bruising
  • The appliance's plug must fit into the mains socket properly. Do not alter the plug. Do not use plug adaptors.
  • Do not force the power cord. Never use the power cord to lift up, carry or unplug the appliance.
  • Do not wrap the power cord around the appliance.
  • Do not allow the power cord to hang or to come into contact with the hot surfaces of the appliance.
  • Check the state of the power cord. Damaged or tangled cables increase the risk of electric shock.
  • Do not touch the plug with wet hands.
  • Use the appliance in a well ventilated
  • Keep children and bystanders away when using this appliance.
  • Do not use or store the appliance outdoors.
  • Do not leave the appliance cut in the rain or exposed to moisture. If water gets into the appliance, this will increase the risk of electric shock.
  • CAUTION: Maintain the appliance dry.
  • CAUTION: Do not use the appliance near water.
  • Do not force the power cord. Never use the power cord to lift up, carry or unplug the appliance.

USE AND CARE:

  • Do not use the appliance if the on/off switch does not work.
  • Unplug the appliance from the mains when not in use and before undertaking any cleaning task.
  • This appliance is for household use only, not professional, industrial use.
  • Store this appliance out of the reach of children and/or those with reduced physical, sensory or mental abilities or unfamiliar with its use
  • Do not store the appliance on areas where the temperature could be lower than 2°C
  • Do not expose the appliance to extreme temperatures.
  • Do not expose to extreme temperatures or strong magnetism.
  • Make sure that dust, dirt or other foreign objects do not block

SOLAC IP1100 - USE AND CARE: - 1

the fan grill on the appliance.

- Never leave the appliance unattended when in use and keep

out of the reach of children,

- Do not use the appliance with pets or animals.

SERVICE:

• Make sure that the appliance is serviced only by specialist personnel, and that only original spare parts or accessories are used to replace existing parts/accessories.
- Any misuse or failure to follow the instructions for use renders
the guarantee and the manufacturer's liability null and void.

SOLAC IP1100 - SERVICE: - 1

SOLAC IP1100 - SERVICE: - 2

PT

Estimado(a) cliente:

Hair\Skin TypeIIIIIIIVVVI
BlackEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
Dark brownEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
BrownEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
Dark blondeEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
Light blondeEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
Red headEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
Gray/whiteEnergy2-3Energy2-3Energy2-3

SOLAC IP1100 - PT - 1

NOTAS:

ECOLOGÍA Y RECICLAJE DEL PRODUCTO

epil Min is apersonal use device intended for the removal of unwanted hair.

RPL™ (REACTIVE PULSED LIGHT) -HOW DOES IT WORK?

It is based on the scientific principle of selective photothermolysis, RPL™ (Reactive Pulsed Light) advanced technology uses clinically proven IPL technology along with a combination of unique skin condition sensors. The light penetrates the epidermis to the dermis and is absorbed by the melanin in the hair shaft. The heat is generated by the absorbed light then dissipates into the follicle and generates local thermal damage, causing a reduction in hair growth.

LONG-TERM HAIR REDUCTION – HAIR GROWTH CYCLE

Two factors play an important role in optimal long-term hair reduction:

- Hair growth cycle involves three phases: Anagen, Catagen, and Telogen. Anagen is the growth phase, while Catagen and Telogen are the resting phases. Permanent hair reduction can only occur during the Anagen phase.

SOLAC IP1100 - LONG-TERM HAIR REDUCTION – HAIR GROWTH CYCLE - 1

EN

Skin types (according to the Fitzpatrick scale) are illustrated in the diagram at the back cover. Darker skin contains more melanin, which competes with the targeted hair for light energy absorption. When more light energy is absorbed into the skin, there is a greater risk for adverse effects and the epidermis may be damaged.

SOLAC IP1100 - EN - 1

COMPONENTS AND DESCRIPTION

  • Handheld device
  • External power supply

HANDHELD DESCRIPTION
1. ON/OFF button and energy level button 2. Trigger button 3. Status indicator: - Lack of contact - Non-allowed skin tone - Device not usable 4. 1-3 energy level lights 5. Skin tone and contact sensor. (Fitzpatrick sensor) 6. Power supply socket 7. Treatment window 8. Lamp

32

manual_epilsense_plegos_0309.indd 32-33 03/09/15 15:29

SOLAC IP1100 - COMPONENTS AND DESCRIPTION - 2

USER INTERFACE DESCRIPTION

The user Interface and control capabilities Include the following features:

1.ON/OFF and energy selection button
- Single button used for the device activation, deactivation, and energy selection.
- Pressing the button (after the device is connected to the power supply) will turn the device on at energy level 1. Each press will change the energy, from the lower level to the higher, for a total of 3 different energy levels.
- The device will switch to standby mode when left unattended or by pressing the ON/OFF button for 3 seconds.

  1. Trigger button (flash pulse activation) marked as s "sun" on the upper side of the device. The trigger button will activate the flash lamp if the treatment window is in full contact with the skin, and the skin tone is in within the allowed range. Pressing the button once will activate a single pulse, pressing and holding the button will activate pulses continuously as long as the button is pressed.

SOLAC IP1100 - The user Interface and control capabilities Include the following features: - 1

SOLAC IP1100 - The user Interface and control capabilities Include the following features: - 2

33

SOLAC IP1100 - The user Interface and control capabilities Include the following features: - 3

SOLAC IP1100 - The user Interface and control capabilities Include the following features: - 4

Indicator Mode
No light OFF Device not working (not connected to the power supply).
“Blinking” green light Standby Device is in standby mode (before powering on or when left unattended for 3 minutes).
1-3 energy level lights Energy level 1-3 The three energy levels are green light indicated by three green LED lights.
“Steady” green light ON Pulse is ready.
“Momentary” orange light Activation (pulse) blocked The device does not deliver a pulse due to the lack of full skin contact.
“Momentary” red light Activation (pulse) blocked The device does not deliver a pulse due to non-allowed skin tone (high Fitzpatrick level as described at the beginning in the Long-term hair reduction-Hair growth cycle section).
“Blinking” orange light Close to end of life Indicates about the close end of lamp life time.
“Steady” red light End of life/ blocked Device is permanently blocked, the lamp has reached the end of its life time or internal malfunction has been occurred.

SOLAC IP1100 - The user Interface and control capabilities Include the following features: - 5

SOLAC IP1100 - The user Interface and control capabilities Include the following features: - 6

WHO SHOULD USE EPIL MINI

  • It is intended for women and men who desire to remove unwanted hair.
  • It is intended for use on legs, arms, underarms, bikini line, back, shoulders, chest, and allowed facial areas.
  • It is intended for use on skin tone types 1 to 5 according to Fitzpatrick skin chart below (see also colored chart at the back cover of this User Guide).

SOLAC IP1100 - WHO SHOULD USE EPIL MINI - 1

The use on naturally dark skin is forbidden.

- It works best on dark hair or hair that contains more melanin. Brown and light brown hair will respond, but typically will require more treatment sessions. Red hair may show some response. Naturally white, grey or blond hair shows more limited response. Nevertheless, some users have noted hair reduction after multiple treatment sessions.

NOTE: this IPL device is designed for use by a single user.

BENEFITS

epil Mini features an automatic built-in skin color sensor that is designed to provide you with complete safety and reassurance. The sensor constantly evaluates your skin tone and allows it to perform only on suitable areas. This smart safety feature also automatically disables the treatment if your skin is too dark or too tanned.

As an extra precaution, the applicator tip has been designed to only emit light pulses when it is in full contact with your skin. Response to epil Mini hair removal differs between individuals, depending on biological factors and how closely treatment instructions are followed. Based on the treatment regime in this User Guide you should expect to see some improvement in 3-4 weeks.

Hair will continue to grow, up to two weeks after a hair reduction session. However, afterwards, as the hair grows in three different stages, the hairs will naturally and gradually fall out depending on the hair growth stage in during which the treatment was performed. Some hair may not be affected by epil Mini as of the different hair growth phases-only hairs in the active growth phase will be affected. For permanent hair removal you should follow the treatment regime.

SOLAC IP1100 - BENEFITS - 1

INSTRUCTIONS

espilsense Mini is intended for use on legs, arms, underarms, bikini line, back, shoulders, chest, and on allowed facial areas.

DEVICE SET-UP

  1. Remove all components from the box (handheld device and power supply).
  2. Before beginning the treatment, make sure the device is clean, dry, and intact.
  3. Plug the power supply end into electrical outlet and the cord end into the device socket (see image - item 6).
    The device is now ready for use.

HOW TO PREPARE YOURSELF

  1. Prior to use, make sure your skin is shaved, clean and dry (free of any residues of powders, creams, makeup, antiperspirants or deodorants).
  2. Between treatments, you can shave but don't wax or pluck hair.
  3. Never use flammable liquids such as alcohol (including perfumes, sanitizers or other applications containing alcohol) or acetone to clean the skin one hour before using epil Mini as it may cause burning of the skin.

REMEMBER: epil Mini comes with a built-in skin-tone sensor, enabling the application only on a suitable skin tone range. This unique safety feature will not let you treat areas where your skin is too dark or too tanned, even if your general skin type is lighter.

  1. For the device maintenance and prolonged use, device cleaning is a must (Cleaning chapter).
  2. Perform a preliminary test on a small patch of the skin (preferably on the intended treatment area) 48 hours prior to first use of epil Mini, to determine energy level settings for your treatment (as depicted in the preliminary test section).
  3. Do not use epil Mini on the face above the cheek line: around eyes, eyebrows, or eyelashes as this could cause serious eye damage.
  4. epil Mini is suitable for men. However, male body hair, especially those on the chest, will require more hair reduction sessions.

PRELIMINARY TEST

The preliminary test is intended to determine your skin's reaction to epil Mini treatment and to help you set the optimal energy level for each treatment area.

Performa preliminary test on each area you intend to treat 48 hours prior to the full treatment.

NOTE: Do not treat full areas with energy levels that you have not tested before!

  • Do not treat the tested area for at least 1 week after the preliminary test is done.
  • Select the lowest energy level and deliver a pulse on the selected preliminary test skin area.
  • If you feel comfortable with the energy level, increase it to level 2 and perform an additional pulse on the next spot.
  • Only if you feel comfortable, you may reach to the maximum energy level 3.
  • Stop the test once you do not feel comfortable, as increasing the energy level increases the risk of adverse effects.
  • If you see adverse effects such as severe redness or blistering stop the test immediately.
  • Wait 48 hours and examine the tested area.

If the skin in the tested area seems normal (no response or mild redness), you can proceed with a full treatment in the highest comfortable energy level that you have tested. If you see extreme redness, swelling, or blis-

tering even in the low-energy level settings, do not do the full treatment in that area.

HOW TO USE EPIL MINI DEVICE

NOTE: A preliminary test should be conducted before proceeding to a full treatment. See "preliminary test section" above.

  1. To turn the device on, press the ON/OFF-button (see image – item 1). Energy level 1 green indicator will light up.
  2. The device sets itself on the lowest energy level - level 1. For other energy levels press the energy level selection button (see image - Item 1).
  3. You may decrease or increase the energy level according to your convenience (to reach the level determined in the preliminary test section). The energy level lights (see image – item 4) will light up green on the level scale according to the selected energy level.
  4. Place the device treatment window (see Image - Item 7) on the desired body area with full contact to the skin. If the device is not properly applied or your skin tone is too dark/tanned, the indicator will be "blinking" red. In this case, the device will not trigger a pulse in that area of your skin.

SOLAC IP1100 - HOW TO USE EPIL MINI DEVICE - 1

  1. Press the trigger button (see image – item 2) and hold it pressed for continuous pulsing.
  2. Press the trigger button once for single pulse.
  3. While pressing the trigger button, you will see a bright flash, you will hear a popping noise and you may feel a mild stinging and/or heat sensation.
  4. Keep the trigger button pressed and start moving the device with each pulse to the next spot without detaching it from the skin. The device will immediately recharge and will be ready for the next pulse. Repeat process until the entire treatment area has been covered.
  5. After the treatment, turn off the device by pressing the "ON/OFF" button for 3 seconds; asteadyorange indicator will light up, while the device is in the shutdown mode. Unplug the unit after each treatment session.

IMPORTANT NOTES:

  • Try not to overlap pulses on the same spot. Repeated pulses on the same spot may cause burns.
  • Do not treat the same area of skin more than once per treatment as it may cause skin irritation.
    • The device will not trigger a pulse if:

a. There is no full contact of the treatment window with the body skin.
b. Your skin tone is too dark or tanned.

TYPICAL TREATMENT INTERVAL:

While treating with epil Mini™, do not overlap pulses on the same spot of skin.

  • Body hair: the first 1–4 hair removal treatments will be approximately two weeks apart.
    The next 5-8 hair removal treatments will be four weeks apart.
  • Facial hair: the first 1–5hair removal treatments will be approximately two weeks apart.

The next 6-8 hair removal treatments will be four weeks apart.

• Treatment 8+ hair removal treatments

will be as needed, until desired results are achieved.

ENERGY LEVELS:

Recommended energy levels are dependent on both your hair color and skin tone in the treated area. For your convenience – below is a table of recommended energy levels per each option.

Important: Facial treatment should be performed at 1-2 energy levels only.

Hair\Skin TypeIIIIIIIVV
BlackEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
Dark brownEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
BrownEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
Dark blondeEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
Light blondeEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
Red headEnergy2-3Energy2-3Energy2-3Energy1-2Energy1-2
Gray/whiteEnergy2-3Energy2-3Energy2-3

SOLAC IP1100 - ENERGY LEVELS: - 1

PLAN YOUR OWN TREATMENT

Energy level should primarily be chosen based on your own comfort.

The energy levels vary from level 1 to level 3 with a light fluence of 3-5 [J/cm2].

Each treatment pulse should be applied on different skin spot with no repetition or overlap. The entire treatment area (underarms, bikini line, arms, back, shoulders, chest, legs and allowed facial areas) will be determined by the user.

NOTES:

  1. Response to epil Mini hair reduction differs between individuals, depending on biological factors.
  2. This device works best on dark hair or hair that contains more melanin. Brown and light brown hair will respond, but typically will require more treatment sessions. Red hair may show some response. White, grey or blond hair shows a more limited response.
  3. It may take up to 3-4 weeks before the full results of the treatment can be seen. Hair will continue to grow, up to two weeks after a hair reduction session. However, afterwards, as the hair grows in three different stages, it will naturally and gradually fall out depen-
  4. Response to epil Mini hair reduction differs between individuals, depending on biological factors.
  5. This device works best on dark hair or hair that contains more melanin. Brown and light brown hair will respond, but typically will require more treatment sessions. Red hair may show some response. White, grey or blond hair shows a more limited response.
  6. It may take up to 3-4 weeks before the full results of the treatment can be seen. Hair will continue to grow, up to two weeks after a hair reduction session. However, afterwards, as the hair grows in three different stages, it will naturally and gradually fall out depen-

ding on the hair growth stage in during which the treatment was performed. Some hair may not be affected by the device as of the different hair growth phases- only hairs in the active growth phase will be affected. To remove this hair multiple treatment sessions are required to achieve the desired results.

  1. The number of sessions required for achieving long term results is different for every treatment area and changes-for every user, as it is affected by type of skin, hair and hormonal changes.
  2. Maintenance will be needed from time to time if growth is still visible.
  3. You may use the treatment log at the end of this User Guide, in order to assist you with recording your specific treatments areas, dates and duration.

FACIAL TREATMENT

The Facial skin is a sensitive area that requires special care and caution. Make sure you follow all instructions and safety precautions carefully in order to avoid adverse effects.

It is recommended you first do a body treatment and get to know the device, before moving on to facial treatments.

This device can be used to treat all facial areas below the cheek line such as upper lip, cheek, jaw, chin and neck.

WARNINGS!

  • Do not use energy level higher than level 2 since it may cause burns.
  • Do not use this device on the face above the cheek line or around the eyes, eyebrows and eyelashes as this could cause serious eye damage.

  • Mark the treatment area with a white eye pencil. Use the mark as guidance for delivering the pluses. This way you can avoid overlapping treatment areas or treating unwanted facial areas.

  • Use a mirror to help you place the treatment window correctly on the treatment area.
  • Follow the instructions for use with additional care to the following specific area instructions.

NOTE: Facial hair may be hormonal and as such, it can take more sessions to achieve a permanent hair reduction.

SOLAC IP1100 - WARNINGS! - 1

SOLAC IP1100 - WARNINGS! - 2

Upper lip, cheek, jaw, neck and chintreatment

Place the treatment window on the area as indicated in the picture. Trigger one pulse on each spot.

- Upper lip: Avoid the nostrils and lip, as these areas are more sensitive.

You can "fold" your lip inward or press the lips together to achieve a better spread treatment area.

Cheekand jaw: Place the treatment window on the area as indicated in the picture. Trigger one pulse on each spot, moving from one side of the jaw/cheek to the other.

Neck and chin: Place the treatment window on the area as indicated in the picture. Trigger one pulse on each spot, moving from one side of the neck/chin to the other.

NOTE: The skin on lower third of the neck is more sensitive. Avoid from overlapping treatment areas.

SOLAC IP1100 - Upper lip, cheek, jaw, neck and chintreatment - 1

SOLAC IP1100 - Upper lip, cheek, jaw, neck and chintreatment - 2

SOLAC IP1100 - Upper lip, cheek, jaw, neck and chintreatment - 3

SOLAC IP1100 - Upper lip, cheek, jaw, neck and chintreatment - 4

For male users

Take care while treating the beard area; the density of hair growth means a large amount of melanin which absorbs the heat. It is recommended performing the first treatment in low energy levels (1-2).

It is not recommended to do a full beard reduction as it may change the facial characteristics and result in a feminine look.

NOTE: Premature aging characteristics can emerge due to complete loss of facial hair.

SOLAC IP1100 - For male users - 1

SOLAC IP1100 - For male users - 2

SOLAC IP1100 - For male users - 3

WHAT TO EXPECT WHEN USING EPIL MINI

During your hair removal treatment it is normal to experience:

  • A flash of light on each press of the activation button. The light will not harm the eyes when the device is applied with full contact to the skin on the recommended treatment areas.
  • A pop noise with each pulse – occurs whenever a pulse is activated.
  • A sensation of warmth – radiates from the light energy after each pulse.
  • A mild stinging sensation –can be felt, similar to being snapped with a rubber band.
  • Some mild red or pink color – appears during and just after the treatment.

POST-TREATMENT CARE

  • Apply a calming lotion such as Aloe Vera.
  • Avoid using peeling and bleaching creams or products for at least 24 hours, as this irritates the treated skin.
  • Avoid direct sun exposure for at least 2 weeks post treatment. If recently treated skin is exposed to sunlight in this period of time, make sure to apply SPF 30 or higher sunscreen.

  • Do not wax or pluck hairs from treated areas.
    Remember! It may take up to 2 weeks for the hair to grow and be fully out, if the hair follicle is still active.

CLEANING AND TROUBLESHOOTING

CLEANING

- Make sure to turn off and unplug the unit before cleaning.

- It is recommended to clean the treatment window after every session by using a dry, clean cloth to gently wipe the device.

- Keep the device dry. Never place, store or use the device near bathtubs, showers, basins or other vessels containing water as this may cause severe electrocution.

- If you do not plan on using your device for a long period of time, it is recommended to keep it clean and stored.

- If you plan to travel and take your device with you, you should store it in the original box and follow the storage instructions.

TROUBLESHOOTING

If you experience any problems with this device please refer to below information to try to resolve it.

SOLAC IP1100 - TROUBLESHOOTING - 1

•If it does not turn on:

- Make sure that the power supply is plugged properly into the device and the electrical outlet.

- Make sure the power outlet has power.

- If it does not trigger a pulse:

- Verify there is full contact with the skin. The trigger button will activate a flash pulse only when the device is in full contact with the skin.

- Verify that the area you are trying to treat is not too small, curved or bony to treat. You should get the whole treatment window in touch with the treatment area (try to pull the skin flat).

- If the skin color level identified by the device is too dark, the flash activation will be blocked.

- In the case of a safety issue or when the lamp has reached it send, a steady red light will come on. The device will shut down.

GENERAL ERROR:

- In case of dirt or debris is stuck on the treatment window, you should clean the treatment window according to the cleaning section. If you can't get the area clean, contact our customer service.

• In case of a delay in pulse readiness, you should consider working in cooler

environment. The device may pulse at a slower rate in warm environment.

  • In case of a general error, reset the device – unplug the power cord from the electrical outlet on the wall, wait 10 seconds and then reconnect it.
  • If you still have problems with your device, please contact customer service.

ANOMALIES AND REPAIR

  • Choose the adequate sentence/s depending of appliance
    • Take the appliance to an authorised technical support service if product is damaged or other problems arise. Do not attempt to disassemble or repair the appliance yourself as this may be dangerous.
    • In case of breakdown call the customer service telephone number indicated in the guarantee sheet. Do not attempt to disassemble or repair the appliance yourself as this may be dangerous.
  • If any anomaly is detected, check the following table:

Anomalies Causes Solutions

- This appliance has been filled with a quantity and quality of certain oils, therefore the replacement or refilling of oil in case of a leakage should be carried

DEVICE SPECIFICATION PARAMETERS

Emitted light spectrum:

475 [nm]to 1,200 [nm]max.

Emitted energy flux: 5 [J/cm²]

Selectable energy levels: 3 levels

Treatment area (window): 3 [cm²]

Speed: 1 pulse every 3 seconds

External Power Supply: 12[V], 1.8[A]

100–240 [VAC], 50–60[Hz]

Deviceweight and size:
- 220 [gr], 135 X 45 X 75 [mm]
- 7.8 [Oz], 5.3 X 1.77 X 2.96 [in]
Technology: Home use IPL

STORAGE INSTRUCTIONS

STORAGE AND TRANSPORT

CONDITIONS

Temperature: -10^ to 70^ ( 14^ to 158^ )
Humidity: 0 to 90% RH at 55°C (131°F)
Pressure: non-condensing

OPERATIONAL CONDITIONS

Temperature: 10°C to 40°C (50°F to 104°F)

Humidity: 30% to 70% RH

Max operating altitude: 10,000 ft.

SOLAC IP1100 - STORAGE INSTRUCTIONS - 1

  • Continuous operation with short-time loading
  • Not suitable for use in presence of flammable anaesthetic mixture with air or with Oxygen or nitrous oxide

NB: These specifications are subject to change without notice of purpose of improvement.

NB: By virtue of the conditions of fabrication of this product, the maximum absorbed power can differ from that specified.
NB: By virtue of the conditions of fabrication of this product, the maximum used power can differ from that specified.

For EU product versions and/or in case that it is requested in your country:

ECOLOGY AND RECYCLABILITY OF THE PRODUCT

The materials of which the packaging of this appliance consists are included in a collection, classification and recycling system. Should you wish to dispose of them, use the appropriate public recycling bins for each type of material.
· The product does not contain concentrations of substances that could be considered harmful to the environment.

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 1

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 2

This symbol means that in case you wish to dispose of the product once its working life has ended, take it to an authorised waste agent for the selective collection of Waste from Electric and Electronic Equipment (WEEE).

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 3

This symbol means that it is important to read the operating instructions.

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 4

This symbol means that user must to consult instructions thoroughly before use.

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 5

This symbol means that user must to consult instructions thoroughly before use.

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 6

This symbol means that surface could to get hot during the use

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 7

This symbol means that product must not be used near water

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 8

Keep away from eyes

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 9

Do not use sensiLight Mini™ device on tanned skin or after sun exposure

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 10

Do not let the device become wet. Keep away from bathtubs, showers, basins, or other vessels containing water: Keep dry

This appliance complies with Directive 2006/95/EC on Low Voltage, Directive 2004/108/EC on Electromagnetic Compatibility, Directive 2011/65/EU on the restrictions of the use of certain hazardous substances in electrical and electronic equipment and Directive 2009/125/EC on the ecodesign requirements for energy-related products.

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 11

SOLAC IP1100 - For EU product versions and/or in case that it is requested in your country: - 12

PT

RPL™ (LUZ PULSADA REACTIVA) - COMO FUNCIONA?

HairSize TypeIIIIIIIVV
Black//Energy 1-3Energy 2-3Energy 2-3Energy 1-2Energy 1-2×
Dark brown//Energy 2-3Energy 2-3Energy 2-3Energy 1-2Energy 1-2×
Brown//Energy 2-3Energy 2-3Energy 2-3Energy 1-2Energy 1-2×
Dark blue//Energy 2-3Energy 2-3Energy 2-3Energy 1-2Energy 1-2×
Light blue//Energy 2-3Energy 2-3Energy 2-3Energy 1-2Energy 1-2×
Red meat//Energy 2-3Energy 2-3Energy 2-3Energy 1-2Energy 1-2×
Green/white//Energy 2-3Energy 2-3Energy 2-3×××

SOLAC IP1100 - RPL™ (LUZ PULSADA REACTIVA) - COMO FUNCIONA? - 1

NOTAS:

natural_image Color gradient bar transitioning from black to white (no text or symbols)

SOLAC IP1100 - NOTAS: - 1

SOLAC IP1100 - NOTAS: - 2

Fitzpatrick skin type scale

123456
×

Do not use sensiLight™ on naturally dark skin types.

SOLAC IP1100 - Fitzpatrick skin type scale - 1

SOLAC IP1100 - Fitzpatrick skin type scale - 2

sOlac

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : SOLAC

Model : IP1100

Category : IPL hair remover