| Product Type | Sensor barrier / speed gate for pedestrian passage control |
| Model | HSB-M01 |
| Dimensions (Interlock Height) | 40-3/16" (1020 mm) |
| Dimensions (Interlock Length) | 69-5/16" (1760 mm) |
| Passage Width | 35-7/16" (900 mm); ADA compliant 36" (915 mm) available |
| Total Width | 51-3/16" (1300 mm) |
| Housing Material | AISI 304 stainless steel, satin finish |
| Barrier Elements | Two curved door leaves made of AISI 304 stainless steel tubes, ∅1-1/16" (26.9 mm) with ∅3/8" (10 mm) vertical struts |
| Drive Type | Low energy, servo-positioning, power-assisted motion (Type 2) |
| Energy Content | Less than 1.18 lb/ft |
| Power Supply | 110–230 VAC, 50/60 Hz, 368 VA |
| Standby Power Consumption | 17 VA |
| Protection Class (Housing) | IP54 |
| Operating Modes | Normally closed, normally open; barriers close on tailgate event |
| Security Features | Light grid monitoring swinging area; basic sensor system for single passage monitoring in both directions |
| Power Failure Behavior | Door leaves move freely (fail-safe open) |
| Installation | Dowelled on finished floor level (FFL); suitable for outdoor installation |
| Compliance | ADA compliant width option available |
Frequently Asked Questions - HSB-M01 Dormakaba
User questions about HSB-M01 Dormakaba
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Access Control in PDF format for free! Find your manual HSB-M01 - Dormakaba and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HSB-M01 by Dormakaba.
USER MANUAL HSB-M01 Dormakaba
HSB-M01 sensor barriers
Moderate

natural_image
3D rendering of two metallic structural transistors with vertical supports and a horizontal bar (no text or symbols)Moderate units offer tailgating monitoring.
Standard units HSB-M01
| Note: Description of single unit | |
| Interlock height 40-3/16" (1020) | |
| Interlock length 69-5/16" (1760) | |
| Passage width | 35-7/16" (900) |
| Total width | 51-3/16" (1300) |
| Housing, base columns, guiding elements | AISI 304 stainless steel with satin finish. |
| ADA compliance 36" (915) width available. | |
| Barrier elements | Two door leaves made of curved AISI 304, ∅1-1/16" (26.9) stainless steel tubes with ∅ 3/8" (10) vertical struts, upper edge 35-7/16" (900). |
| Swinging area monitored by a light grid. | |
| Security Passage area monitored by basic sensor system with a compact installation length (basic level of single passage monitoring in both directions) | |
| Finish Stainless steel semi-gloss smooth finish. | |
| Safety Low energy drive with energy content less than 1.18 lb/ft. | |
| Function Type 2-power assisted motion; two servo-positioning drives/electrically controlled in both directions. | |
| Drives Integrated in the swing tube. | |
| Operating modes Optical. | Normally closed.Normally opened. (Barriers close on tailgate event.) |
| Electrical equipment Control system and power supply integrated in the unit. | |
| Power supply 110 - 230 VAC, 50/60 Hz, 368 VA | |
| Standby power consumption | 17 VA |
| Standard adjustment in case of power failure | Door leaves move freely. |
| Installation Dowelled on finished floor level FFL. | |
| Suitable for outdoor installation. | |
| Protection classes | Housing IP54, components conducting supply voltage IP54. |
HSB-M01



HSB-M01
Installation drawings

Note
Dimensions shown as inches followed by millimeters; for example, 1" (25).