608-206 - Battery charger Hamron - Free user manual and instructions
Find the device manual for free 608-206 Hamron in PDF.
| Product Type | Portable Jump Starter with Compressor and Work Light |
| Brand | Hamron |
| Model | 608-206 |
| Dimensions (W x H x D) | 250 mm x 280 mm x 180 mm |
| Weight | 6.7 kg |
| Built-in Battery Type | Sealed lead-acid (rechargeable) |
| Battery Capacity | 17 Ah |
| Charging Power | 11 A |
| Nominal Output Voltage (DC outlet) | 12 V DC |
| Maximum Compressor Pressure | 17.9 bar (260 psi) |
| Charging Time (Initial, 230V) | 38 hours |
| Charging Time (Subsequent, 230V) | 34–36 hours |
| Charging Time (Subsequent, 12V) | 12–14 hours |
| Operating Temperature Range | Up to 54°C |
| Storage Conditions | Dry and cool |
| Key Functions | Jump starting, power supply (12V), work light, compressor |
| Battery Status Indication | LED indicator lights (green/orange/red) |
| Polarity Protection | Indicator for polarity error (red/green) |
| Safety Features | Overcharge protection, spark-proof, safety glasses required |
| Maintenance | Recharge after use; do not leave discharged; maintenance charge every 2-3 months |
| Included Accessories | 230V charger, 12V charging cable, air hose with nozzle, clamps |
Frequently Asked Questions - 608-206 Hamron
User questions about 608-206 Hamron
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Battery charger in PDF format for free! Find your manual 608-206 - Hamron and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 608-206 by Hamron.
USER MANUAL 608-206 Hamron
EN - Operating instructions (Translation of the original instructions)
Jula reserves the right to make changes. In the event of problems, please contact our service department.
www.jula.com
Tillverkare/ Produsent / Produenci/ Manufacturer
Jula AB, Box 363, 532 24 SKARA
Importör/ Importør/ Importer/ Importer
SAFETY INSTRUCTIONS 26
TECHNICAL DATA....27
DESCRIPTION 28
USE 29
Auxiliary starter battery 29
Battery control 29
Work light 30
Auxiliary starting of engine 30
Power supply via 12 V outlet on the auxiliary starter. 31
compressor....31
SÄKERHETSANVISNINGAR
Read the user instructions carefully before use.
Save them for future reference.
WARNING:
- Do not work alone.
- Wear safety glasses and safety clothes. Avoid contact with the yes when working near batteries.
- Never attempt to dismantle or replace the built-in battery. Spent batteries must be disposed of in accordance with applicable regulations.
- Do not connect anything to the 12 V outlet except the appliance to be powered.
- Remove all metal objects from your body (rings, bracelets, necklaces, watches, etc.) when working with lead-acid batteries. They may cause short-circuits, which may in turn cause serious fire damage.
- Never charge frozen batteries.
- Never short-circuit the clamps with any metal object or by allowing them to touch each other.
- Do not wear clothes made of vinyl or other materials that could generate static electricity.
- Do not use the appliance in the rain, or temperatures over 54^ C .
- Only use the charger, cables and clamps supplied. Use of other accessories could damage the appliance.
• This is not a toy. Store out of the reach of children.
- Keep the battery terminals clean. Take care to avoid getting battery acid in your eyes.
- Do not use the appliance near water.
- If you get battery acid in your eyes, rinse immediately with cold, running water for at least 10 minutes and call a doctor.
- Switch off the appliance when not in use. Store in a dry and cool place.
- Do not open the appliance. The appliance does not contain any parts that can be repaired by the user. The warranty will be invalidated if the appliance is opened up.
- Store out of the reach of children. The charger is not intended to be used by persons (children or adults) with any form of functional disorders, or by persons who do not have sufficient experience or knowledge on how to use it, unless they have received instructions concerning the use of the charger by someone
who is responsible for their safety. Keep children under supervision to make sure they do not play with the charger. Do not allow children to use, clean or maintain the charger without supervision.
Risk of explosion
- Do not expose the battery to naked flames or high temperatures: risk of explosion.
- Contains sealed lead-acid battery. Discard the battery immediately if the casing is damaged.
• Take suitable measures to avoid personal injury and/or material damage. - Batteries must be disposed of in accordance with applicable regulations.
TECHNICAL DATA
| Voltage | 12 V |
| Weight 6.7 kg | |
| Dimensions W250xH280xD180 mm | |
| Max working pressure 17.9 bar (260 psi). | |
| Capacity | 17 Ah |
| Charging power 11 A | |
| Battery 17 Ah rechargeable sealed lead acid battery | |
| DC outlet 12 V nominal | |
| Compressor 17.9 bar | |
| Charging time, built-in battery | |
| 38 hours for initial charging with 230 V charger | |
| 34–36 hours for subsequent charging with 230 V charger | |
| 12–14 hours for subsequent charging with 12V charger | |
| Storage temperature dry and cool |
DESCRIPTION

-
Power switch for 12 V outlet
-
12 V outlet
-
Battery test button
-
Charging indicator, battery
-
Charging indicator light
-
Charging connection
-
Power switch for work light
-
Work light
-
Positive clamp (red) and negative clamp (black) for starter cables
-
Compressor power switch
-
Manometer
-
Air hose with nozzle
-
230 V charger
-
Cable for 12 V charging
-
Power switch for starter cables (on the left side of the auxiliary starter). Always leave in the OFF position except when using auxiliary starting.
-
Indicator for polarity error
USE
AUXILIARY STARTER BATTERY
- The auxiliary starter has a built-in, maintenance-free, sealed, rechargeable lead acid battery.
- The auxiliary starter is partially charged on delivery, but must be charged for at least 38 hours before first use, even if the indicator light shows a fully charged battery. Otherwise the battery could be permanently damaged.
- Do not charge the auxiliary starter for more than 48 hours. Only use the adapters supplied for charging.
- Ensure that the battery is always charged, so it is ready for use when needed. The battery will not be damaged by being charged often. Charge the battery as soon as possible after use, and it will last longer. The battery lifetime will be shortened if it is discharged a lot and often without being recharged.
- Do not allow the auxiliary starter battery to remain discharged for long periods, as this can destroy the battery. Lead acid batteries discharge by themselves over time, particularly at extreme temperatures.
- Store in a dry and cool place. The battery should be maintenance charged at 2–3 month intervals if it is not used – more often if it is stored in a very hot or very cold place – to keep it in the best condition.
- NOTE: Do not use any of the functions of the auxiliary starter while charging is in progress.
Charge the auxiliary starter battery via a 230 V mains outlet.
- Connect the 230 V charger to a mains outlet and to the charging connection on the auxiliary starter. The charging indicator light will come on.
- It takes 34–36 hours to charge the battery fully, depending on the charge level.
Charge the auxiliary starter battery via a 12 V outlet.
- Connect the cable for 12 V charging to the vehicle's 12 V outlet and to the 12 V charging connection on the auxiliary starter unit.
- It takes 14–16 hours to charge the battery fully, depending on the charge level.
- NOTE: On some vehicles, the ignition must be switched on for the 12 V outlet to be live.
BATTERY CONTROL
- Press the battery control button to see the charge level in the built-in battery in the auxiliary starter.
- The indicator lights come on to show the battery charge level. The indicator lights go off when you release the button.
- Disconnect the charging adapter from the battery to get a correct indication.
Indicator lights

A. Two green indicator lights: No charging required. The battery is fully charged. Ideal level for auxiliary starter.
B. Green indicator light: Good charging level. The auxiliary starter can power most appliances intended for 12 VDC. It may need to be fully charged to be used as an auxiliary starter.
C. Orange indicator light: Low charge level – recharge as soon as possible.
D. Battery control button
E. Red light: Recharge as soon as possible – very low charge level.
F. The red light comes on while the battery is being charged and stays on when it is fully charged. The light goes off when the charging adapter is disconnected.
WORK LIGHT
- The work light is powered by the built-in battery in the auxiliary starter.
- Switch the working light on and off with the power switch.
- Switch the work light off when not in use to save the battery.
AUXILIARY STARTING OF ENGINE
NOTE: Place the auxiliary starter so that it cannot fall over when the vehicle starts. Place the cables so they cannot be damaged by the cooling fan or drive belts.
Before auxiliary starting of engine
- The auxiliary starter must be fully charged when it used to start the engine. Check that the power switch for the starter cables is in the OFF position.
- Do not attempt to use the auxiliary starter to start the engine if the battery indicator light is not green when you check it – this could permanently damage the battery.
- Switch off the ignition and all systems (lights, radio, air-conditioning etc.) in the vehicle. Put it
out of gear and pull the handbrake on. Automatic gearboxes should be in position P (parking).
- Disconnect any equipment connected to the 12 V outlet. Turn all switches on the auxiliary starter to the OFF position.
Auxiliary starting of engine
- Check that the negative terminal on the battery is connected to the vehicle chassis (usually).
- Connect the red positive clamp (+) on the auxiliary starter firmly to the positive terminal (+) on the vehicle battery.
- Connect the black negative clamp (-) firmly to some metal part of the vehicle as far away from the battery as possible. Do not connect it to the negative terminal on the battery. Check that both terminals make good contact. Check polarity markings on the cable.
- If the indicator light is green, turn the power switch for the starter cables to the ON position.
- If the indicator light is red, you should swap the connection clamps over before continuing.
-
Run the starter motor repeatedly for 5–6 seconds until the engine starts.
-
If the engine does not start after 2–3 attempts, let the auxiliary starter cool for 3 minutes and try again.
-
Stop trying to start the engine immediately if the battery indicator light does not show that the battery is sufficiently charged.
-
Once the engine has started, turn the switch for the starter cables to the OFF position then disconnect first the black negative clamp (-) and then the red positive clamp (+).
-
Replace the clamps on the auxiliary starter and charge the battery as soon as possible.
POWER SUPPLY VIA 12 V OUTLET ON THE AUXILIARY STARTER.
The auxiliary starter can be used to power 12 V products with a 12 V plug to fit the cigarette lighter socket.
- Lift the cover of the 12 V outlet.
- Connect the 12 V product to the outlet.
COMPRESSOR
Inflating tyres
- Follow the manufacturer's instructions for recommended pressure. Do not over-inflate. Most tyres should be inflated to between 1.7 and 2.4 bar. Some truck and cycle tyres should be inflated to 2.8 bar or more.
- Remove valve cap. NOTE: Check that the locking lever is in the folded up position. Use an adapter if necessary.
- Place the nozzle over the valve and press it right down.
- Fold down the locking lever into the locked position.
- Start the compressor by pressing down the side of the power switch marked I. NB: If the tyre
is completely flat, raise the vehicle with an approved jack before inflating the tyre.
- Monitor the air pressure on the manometer. NOTE: We recommend checking the actual tyre pressure with a separate manometer.
- When the desired pressure has been reached, turn off the compressor, fold up the locking lever and disconnect the nozzle from the valve. Also remove any adapter.
- Replace the valve cap.
Blowing up air mattresses, beach balls, inflatable boats etc.
- Follow the manufacturer's instructions for recommended pressure.
- Remove valve cap.
- Push a suitable adapter into the nozzle as far as it will go and fold down the locking lever.
- Push the other end of the adapter into the inflation nozzle.
- Set the compressor power switch to the ON position.
- Monitor the air pressure on the manometer.
- When the desired pressure has been reached, turn off the compressor, fold up the locking lever and disconnect the nozzle from the valve. Also remove any adapter.
- Replace the valve cap.

Värna om miljön!
Care for the environment!
Must not be discarded with household waste! This product contains electrical or electronic components that should be recycled. Leave the product for recycling at the designated station e.g. the local authority's recycling station.