Product Type Hand blender (immersion blender)
Brand ECG
Model RM 994
Power Supply 220–240 V ~ 50/60 Hz
Power Consumption 500 W
Speeds 2 speeds: standard and TURBO
Control Soft-Touch buttons
Blade Material Stainless steel
Attachment Material Stainless steel
Mixing Bowl Capacity 600 ml (transparent)
Maximum Food Temperature 80 °C
Maximum Continuous Operation 1 minute
Cool Down Time At least 3 minutes before next use
Noise Level 80 dB
Handle Design Ergonomic
Detachable Shaft Yes, with release button
Dishwasher Safe Parts Yes (blade attachment, mixing bowl, etc.; motor body only wipe clean)
Safety Features Automatic shut-off if overheating (implied by rest requirement), sharp blade caution
Intended Use Domestic use only; for gravies, soups, mayonnaises, baby food, cocktails, milkshakes
Not Suitable For Crushing ice, cutting nuts, or hard foods
Weight Approximately 0.8 kg (estimated)
Dimensions (LxWxH) Approximately 38 x 8 x 8 cm (estimated)

Frequently Asked Questions - RM 994 ECG

How long can I use the hand blender continuously?
The maximum continuous operation time is 1 minute. After that, let the appliance rest for at least 3 minutes before using it again to prevent overheating.
Can I blend hot liquids with this blender?
Yes, but the maximum temperature of the food should not exceed 80 °C. Do not blend boiling liquids.
Is the blade attachment dishwasher safe?
Yes, the removable attachment and mixing bowl are dishwasher safe. However, the motor body should only be wiped with a damp cloth. Never immerse it in water.
Can I crush ice or grind nuts with this blender?
No, this blender is not designed for crushing ice, cutting nuts, or processing other hard foods. Use it only for soft ingredients.
What should I do if the blender stops working during use?
If the blender stops due to overheating, unplug it and let it cool down for at least 3 minutes. Then it can be used again. If it still doesn't work, check the power outlet or contact service.
How do I attach the blender shaft?
Place the removable attachment onto the motor unit until it clicks into place. To remove, press the release button and pull the attachment off.
What is the power supply requirement?
The blender requires a 220–240 V ~ 50/60 Hz power outlet. Ensure your mains voltage matches.
Can I use the blender with wet hands?
No, never touch the cord or blender with wet hands to avoid electric shock.
How should I clean the blender after use?
Unplug and let cool. Wipe the motor body with a damp cloth. The shaft and bowl can be washed in the dishwasher or rinsed immediately after use. Be careful of sharp blades.
What is the warranty on this product?
The manufacturer's warranty applies for domestic use. Using unauthorized accessories or improper use may void the warranty. Refer to the manual for details.

User questions about RM 994 ECG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Hand blender in PDF format for free! Find your manual RM 994 - ECG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. RM 994 by ECG.

USER MANUAL RM 994 ECG

natural_image White ECG brush and clear glass of juice, no visible text or symbols on the main objects

RM 994

TYČOVÝ MIXÉR

NÁVOD K OBSLUZE

TYČOVÝ MIXÉR

NÁVOD NA OBSLUHU

BLENDER RE CZNY

INSTRUKCJA OBSŁUGI

BOTMIXER

HASZNÁLATI ÚTMUTATÓ

STABMIXER

BEDIENUNGSANLEITUNG

HAND BLENDER

INSTRUCTION MANUAL

CZ

SK

PL

HU

DE

EN

BEZPEČNOSTNÍ POKYNY

ECG RM 994 - BEZPEČNOSTNÍ POKYNY - 1

POKYNY K POUŽITÍ - MIXÉR

Labeled diagram of a handheld device with numbered parts for identification

ECG RM 994 - POKYNY K POUŽITÍ - MIXÉR - 2

POKYNY NA POUŽITIE - MIXÉR

Diagram illustrating four stages of a robotic brush tool: press, press, presser, and manual press with a crossed handle.

ECG RM 994 - POKYNY NA POUŽITIE - MIXÉR - 2

INSTRUKCJA UŻYTKOWANIA - BLENDER

ECG RM 994 - INSTRUKCJA UŻYTKOWANIA - BLENDER - 1

Technical diagram showing four stages of a mechanical device with directional arrows and a cross symbol indicating disassembly or reassembly.

ECG RM 994 - INSTRUKCJA UŻYTKOWANIA - BLENDER - 3

HASZNÁLATI ÚTMUTATÓ - MIXER

Technical diagram illustrating four stages of a mechanical device operation: press, press, press with tool, and disassembly.

ECG RM 994 - HASZNÁLATI ÚTMUTATÓ - MIXER - 2

BENUTZUNGSHINWEISE - STABMIXER

Technical diagram showing four stages of a mechanical device with directional arrows and a cross-sectional view.

Read carefully and save for future use!

Warning: The safety measures and instructions, contained in this manual, do not include all conditions and situations possible. The user must understand that common sense, caution and care are factors that cannot be integrated into any product. Therefore, these factors shall be ensured by the user/s using and operating this appliance. We are not liable for damages caused during shipping, by incorrect use, voltage fluctuation or the modification or adjustment of any part of the appliance.

To protect against a risk of fire or electric shock, basic precautions shall be taken while using electrical appliances, including the following:

  1. Make sure the voltage in your outlet corresponds to the voltage provided on the appliance label and that the socket is properly grounded. The outlet must be installed according to valid safety instructions.
  2. Do not operate blender with a damaged cord. All repairs including cord replacements shall be performed by a professional service centre! Do not remove protective covers of the appliance, risk of electric shock!
  3. Protect the appliance against direct contact with water and other liquids, to prevent potential electric shock.
  4. Do not operate the immersion blender outdoors or in a moist environment and do not touch the cord or appliance with wet hands. Risk of electric shock.
  5. Close supervision is necessary for operating the immersion blender near children!
  6. Do not leave the immersion blender running unattended.
  7. Hair, fingers or parts of clothing shall be kept far enough from the moving parts of the appliance. Do not place any tools or hands into the bowl while blending, risk of injury or damaging the appliance. You may use the spatula only if the blender is switched off.
  8. Before switching the appliance on, set the container in place, attach the blades to the motor and only then insert the plug in the power outlet. This reduces the risk of injury.
  9. Pay close attention when handling attachments, blades are very sharp and can cause injury.
  10. Use the immersion blender for processing foods only. The highest possible temperature of processed food is 80^ C. Do not use boiling food.
  11. Leaving the blender cord connected to outlet unattended is not recommended. Disconnect the cord from the electrical outlet prior to performing maintenance. Do not pull the cord from the outlet by yanking the cord. Unplug the cord from the outlet by grasping the plug.
  12. Do not use the immersion blender near a source of heat, for example, an oven. Protect it from direct sunlight.
  13. Do not allow the cord to touch hot surfaces or lead the cord over sharp edges.
  14. Always unplug from outlet immediately after use.
  15. Use accessories only approved by the manufacturer, otherwise you risk voiding the warranty.
  16. Use the immersion blender only in accordance with the instructions in this manual. This immersion blender is intended for domestic use only. The manufacturer is not liable for damages caused by the improper use of this appliance.
  17. The appliance may be used by persons with reduced physical, sensorial or mental capacities or lack of experience and knowledge, if they are supervised or if they were instructed how to use the appliance safely and understand potential dangers.
  18. Children may not play with the appliance
  19. This appliance shall not be used by children. Keep the appliance and power supply away from children.

DESCRIPTION

  1. Speed button I
  2. Higher speed button - TURBO
  3. Appliance body
  4. Replacing attachment button
  5. Detachable pan blender
  6. Measuring jar for the blender

Labeled diagram of a handheld device with numbered parts for identification

ECG RM 994 - DESCRIPTION - 2

INSTRUCTIONS FOR USE - BLENDER

Technical diagram showing four stages of a mechanical device with directional arrows and a cross-sectional view.

The immersion blender is intended for preparing gravies, icings, soups, mayonnaises, children's dishes, cocktails and milkshakes.

Before fi rst use:

Before using the blender for the first time, fill the bowl half way with water, immerse the blade of the blender to the bottom of the bowl and blend for several seconds. Rinse the entire attachment and bowl well afterwards.

  1. Insert the ingredients into the mixing bowl or another higher kitchen container. Do not use the blender to crush ice, cut nuts or other hard food.
  2. Place the removable attachment on the motor until it "falls" into place.
  3. Uncoil the entire cord and plug into the outlet.
  4. Insert the appliance into the mixing bowl containing food and press the desired speed button on the upper part of the appliance body. Blend in circular motions from the bottom.
  5. Release the button to stop the blender. Unplug the power cord from the outlet after you have finished blending.

EN

Note: The maximum time for continuous operation of the appliance is 1 minute, let it rest for at least 3 minutes prior to further use. Otherwise the appliance will overheat and become damaged.

MAINTENANCE AND CLEANING

  • Disconnect the appliance from the electrical outlet prior to performing any maintenance.
    • Always allow the appliance to cool before cleaning.
  • Do not use scrubber, abrasive cleaners or solvents.
  • Wipe the body containing the motor using wet cloth. Never immerse in water!
  • All other parts may be washed in the dishwasher. However, we recommend that you rinse the appliance immediately after use, when processing very salty foods.
    • Take care that you do not use too much of detergent or descaling products in the dishwasher.
  • When processing foods with food dyes, the plastic parts of the appliance may become stained. Wipe these parts with vegetable oil before you load them into the dishwasher.
  • The blades are very sharp, be very careful when cleaning the appliance!

Quick rinsing

Immerse the tool in a glass half filled with water and let it run for a few seconds between individual uses.

TECHNICAL SPECIFICATIONS

Ergonomic handle

2-speed Soft-Touch buttons

Stainless steel attachment

Stainless steel blades

Low weight and silent operation

Transparent mixing bowl 600 ml

Noise level: 80 dB

Nominal voltage: 220–240 V\~ 50/60 Hz

Nominal input power: 500 W

USE AND DISPOSAL OF WASTE

Wrapping paper and corrugated paperboard – deliver to scrapyard. Packing foil, PE bags, plastic elements – throw into plastic recycling containers.

DISPOSAL OF PRODUCTS AT THE END OF LIFETIME

Disposal of electric and electronic equipment (valid in EU member countries and other European countries with an implemented recycling system)

The represented symbol on the product or package means the product shall not be treated as domestic waste. Hand over the product to the specified location for recycling electric and electronic equipment. Prevent negative impacts on human health and the environment by properly recycling your product.

Recycling contributes to preserving natural resources. For more information on the recycling of this product, refer to your local authority, domestic waste processing organization or store, where you purchased the product.

This product complies with EU directive requirements on electromagnetic compatibility and electrical safety.

Changes in text and technical parameters reserved.

ECG RM 994 - DISPOSAL OF PRODUCTS AT THE END OF LIFETIME - 1

08/05
ECG RM 994 - DISPOSAL OF PRODUCTS AT THE END OF LIFETIME - 2

EN

www.ecg.cz

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ECG

Model : RM 994

Category : Hand blender