ND-183-D - Frying Pan Cotech - Free user manual and instructions
Find the device manual for free ND-183-D Cotech in PDF.
| Type | Electric fireplace stove fan heater |
| Model | ND-183-D |
| Brand | Cotech |
| Dimensions (H × W × D) | 74 × 44 × 32 cm |
| Weight | Approx. 12.5 kg |
| Rated Voltage | 220–240 V AC, 50 Hz |
| Power Settings | 1000 W (low) and 2000 W (high) |
| Heat Output (Nominal) | 2.0 kW |
| Heat Output (Minimum) | 1.0 kW |
| Flame Effect | LED-based, can operate without heat |
| Thermostat | Adjustable, with automatic on/off |
| Safety Features | Overheating protection, tip-over switch |
| Recommended Clearances | 120 cm front, 50 cm other sides |
| Mains Lead Length | 1.5 m |
| Light Source | LED (non-replaceable) |
| Energy Efficiency Class | Seasonal space heating efficiency 36% |
| Cleaning | Soft cloth, vacuum air vents |
| Use | Indoor, temporary heating of well-insulated rooms |
| Country of Origin | Sweden (CLAS OHLSON AB) |
Frequently Asked Questions - ND-183-D Cotech
User questions about ND-183-D Cotech
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Frying Pan in PDF format for free! Find your manual ND-183-D - Cotech and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ND-183-D by Cotech.
USER MANUAL ND-183-D Cotech
Important:
Read the entire instruction manual carefully and make sure that you fully understand it before you use the equipment. Keep the manual for future reference.
Viktig information:
Original instructions
Bruksanvisning i original
Originalbruksanvisning
Please read the entire instruction manual before use and then save it for future reference. We reserve the right for any errors in text or images and any necessary changes made to technical data. In the event of technical problems or other queries, please contact our Customer Services (see address details on the back).
Safety
General requirements for household electrical appliances
- The product may be used by children of 8 years and above and by persons with reduced physical, sensory or mental capability or lack of experience and knowledge provided they have been given supervision or instruction concerning use of the product in a safe way and understand the hazards involved.
- Never let children play with the product.
- Cleaning and user maintenance must not be performed by children without adult supervision.
Particular requirements for room heaters

Warning: Never cover the product. If covered, there is a risk of overheating or even fire.
⚠ Warning
- The product can become very hot during use and cause burns. Burn hazard. Special care must be taken if the product is used in the same room as young children, aged or infirm persons.
- The product must never be placed directly beneath a wall socket.
- Never use the product in the immediate vicinity of bathtubs, showers or swimming pools.
-
The appliance must be kept out of reach of children under 3 years of age unless they are under constant supervision.
-
Children between the ages of 3 and 8 years must only switch the appliance on/off provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children between the ages of 3 and 8 years must not plug in, regulate and clean the appliance or perform user maintenance.
Safety instructions
⚠ Warning: Dangerous voltage
- The product should not be used if it is in any way damaged or malfunctioning. Do not use the product if the mains lead or plug is damaged in any way.
- The mains lead must be changed if damaged. This is to prevent the risk of electric shock or fire and should only be carried out by the manufacturer, qualified service facility or qualified technician.
- The product must not be taken apart or modified. Certain unshielded components inside the housing carry dangerous voltages. Contact with these can lead to fire or electric shock.
- Never lower the product into water or other liquids.
- Never touch the control panel or plug with wet hands.
- Never use the product in the rain or in wet conditions.
Warning
- Never leave the product unattended while in use.
- Do not touch any hot surfaces on the product; doing so could result in burns. Never move the product while it is in use or before it has cooled down.
-
Fire hazard. Flammable materials such as furniture, paper, clothing and curtains must be at kept at a distance of at least 120 cm away from the front of the product above and at least 50 cm in all other directions.
-
Do not place towels or similar objects on the product.
- Ensure that the product is kept clean. Make sure that no foreign objects can enter the ventilation openings as this can present a risk of electric shock or fire.
- The product must never be used near flammable gases or liquids.
- The product is only intended for normal domestic use and only in the manner described in this instruction manual. Using the product for other than its intended use may lead to fire, electric shock, other types of personal injuries or material damage.
- Children in the area where the product is used must be kept under supervision.
- The product is intended for indoor use only.
- Make sure to route the mains lead behind the product so that it is not heated by the hot air from the product.
- The product must only be plugged into to an earthed 230 V, 50 Hz power outlet. Never connect the product to the electricity mains using an extension lead.
△ Important
- Always unplug the product from the wall socket when it is not in use.
- Disconnect the product from the power supply by unplugging it from the wall socket. Make sure that the wall socket and plug are easily accessible.
- The product must not be connected to the mains during installation or service.
- The product must only be used in the upright position.
Product description
i Information
The product is designed for temporary use in well-insulated rooms.
• Electric fireplace stove fan heater.
- Two heat settings, 1000 and 2000 W.
- Adjustable thermostat.
• Overheating protection.


A. Flame effect
B. Air outlet
C. Control panel
D. Air inlet
Buttons and functions
E. [I/0] Power switch, on/off
F. [I] Power setting I, 1000 W
G. [II] Power setting II, 2000 W
H. Thermostat knob

Instructions for use
Note
Bear in mind that factors such as the size of the room, the outside temperature and how well the building is insulated, all affect the ability of the heater to warm the room up. If the room is too large the ability of the heater to warm it up to the desired temperature may be insufficient.
- Place the electric stove on a firm, level floor surface.
- Plug the product into a wall socket.
Flame effect without fan heater function
- Set the [I/O] switch (E) to I to switch the stove on, the flame effect comes on.
- Set the [I/0] switch to 0 to switch the stove off, the flame effect will go out.
Flame effect plus fan heater function
- Set the [I/O] switch to I to switch the stove on, the flame effect comes on.
- Turn the thermostat knob (H) clockwise to the maximum setting.
- Press in [I] (F) to select 1000 W or press in both [I] and [II] (G) to select 2000 W.
-
When the desired ambient temperature has been reached, slowly turn the thermostat knob back until it clicks and the fan heater switches off. Leave the thermostat knob in that position.
-
The stove will maintain the set temperature by automatically switching on and off.
-
The temperature can be adjusted by turning the thermostat knob:
-
clockwise to raise the temperature
-
anticlockwise to lower the temperature.
-
Set the [I/O] switch to 0 to switch the stove off, the flame effect will go out.
Overheating protection
The electric stove is fitted with an overheating safety cut-off protection device which switches the appliance off if it overheats. To reset the overheating protection device:
- Set the [I/O] switch to 0.
- Unplug the stove from the wall socket and let it cool for at least 15 minutes.
- Then plug the heater back into a wall socket. The heater should now work normally.
Tip-over switch
The electric stove is fitted with a tip-over switch which switches the stove off if it tilts or falls over. The tip-over switch resets when the stove is returned to the upright position.
Care and maintenance
- Switch the stove off, unplug it from the wall socket and let it cool before cleaning.
-
Clean the exterior of the stove using a soft cloth. Dampen the cloth with a little water if required, do not use detergent, solvent or corrosive chemicals.
-
Get into the habit of vacuum cleaning the air inlet and outlet regularly.
- Store the stove indoors when it is not in use.
- The lights inside the electric stove are LEDs and cannot be replaced.
Troubleshooting guide
| The flame effect doesn’t come on. | Is the power switch set to ON (I)?Is the mains lead intact and properly plugged into the wall socket?Is the wall socket live? |
| The fan heater does not start. | Is the power switch set to ON (I)?Is the power setting I switch pressed in?Are the power setting switches I and II pressed in?Has the thermostat turned off the fan heater?Turn the thermostat knob clockwise.Is the mains lead intact and properly plugged into the wall socket?Is the wall socket live?The overheating protection has tripped. Reset as instructed in the Overheating protection section. |
| The fan heater starts but stops after a short time. | The thermostat is set to a lower temperature than the current room temperature. Check the thermostat setting. |
Responsible disposal
This symbol indicates that this product should not be disposed of with general household waste. This applies throughout the entire EU. In order to prevent any harm to the environment or health hazards caused by incorrect waste disposal, the product must be handed in for recycling so that the material can be disposed of in a responsible manner. When recycling the product, take it to your local collection facility or contact the place of purchase. They will ensure that the product is disposed of in an environmentally sound manner.

Specifications
Rated voltage 220–240 V AC, 50 Hz
Power 1000 and 2000 W
Bulb LED (non-replaceable)
Mains lead 1.5 m
Size 44 × 32 × 74 cm
Weight Approx. 12.5 kg
Information requirement for the electric local space heaters
| Model identifier(s): ND-183-D | |||||
| Art.no: 36-7800 | |||||
| Item Symbol Value Unit | Item | ||||
| Heat output Type of heat input, for electric storage | local space heaters only (select one) | ||||
| Nominal heat output P | nom | 2.0 kW | manual heat charge control, with integrated thermostat | N/A | |
| Minimum heat output (indicative) | Pmin | 1.0 kW | manual heat charge control with room and/or outdoor temperature feedback | N/A | |
| Maximum continuous heat output | Pmax,c | 2.0 kW | electronic heat charge control with room and/or outdoor temperature feedback | N/A | |
| Auxiliary electricity consumption | --- --- --- fan assisted heat output N/A | ||||
| At nominal heat output | eImax | 0.013 kW | Type of heat output/room temperature control (select one) | ||
| At minimum heat output | eImin | 0.013 kW | single stage heat output and no room temperature control | No | |
| In standby mode eI | SB | 0 | kW | Two or more manual stages, no room temperature control | No |
| with mechanic thermostat room temperature control | Yes | ||||
| with electronic room temperature control | No | ||||
| electronic room temperature control plus day timer | No | ||||
| electronic room temperature control plus week timer | No | ||||
| Other control options (multiple selections possible) | |||||
| room temperature control, with presence detection | No | ||||
| room temperature control, with open window detection | No | ||||
| with distance control option No | |||||
| with adaptive start control | No | ||||
| with working time limitation | No | ||||
| with black bulb sensor | No | ||||
| Contact details | CLAS OHLSON AB, SE-793 85 INSJÖN, SWEDEN | ||||
Test Data
Commission Regulation (EC) No 1275/2008 Requirement
| Mode Ecodesign | requirements, from 7 January 2013 Result - Remark Verdict | ||
| Off mode Power | consumption in ‘off mode’:Power consumption of equipment in any off-mode condition shall not exceed 0.50 W | P | |
| Standby mode P | power consumption in ‘standby mode(s)’:The power consumption of equipment in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 0.50 W. | N/A | |
| The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display shall not exceed 1.00 W. | N/A |
Seasonal space heating energy efficiency
| Description Value | |
| Seasonal space heating energy efficiency in active mode- ηS,on | 40 % |
| For electric local space heaters- ηth | |
| The electric to primary energy “conversion coefficient”-CC | |
| F(1) is a correction factor accounting for a positive contribution to the seasonal space heating energy efficiency of electric storage local space heaters due to adjusted contributions for options for heat storage and output; and a negative contribution to seasonal space heating efficiency for commercial local space heaters due to adjusted contributions for options for the heat output, expressed in %; | 0 % |
| F(2) is a correction factor accounting for a positive contribution to the seasonal space heating energy efficiency due to adjusted contributions of controls of indoor heating comfort, the values of which are mutually exclusive, cannot be added to each other, expressed in %; | 6 % |
| F(3) is a correction factor accounting for a positive contribution to the seasonal space heating energy efficiency due to adjusted contributions of controls for indoor heating comfort the values of which can be added to each other, expressed in %; | 0 % |
| F(4) is a correction factor accounting for a negative contribution to the seasonal space heating energy efficiency by auxiliary electricity consumption, expressed in %; | 0 % |
| F(5) is a correction factor accounting for a negative contribution to the seasonal space heating energy efficiency by energy consumption of a permanent pilot flame, expressed in %. | 0 % |
| Seasonal space heating energy efficiency- ηS | 36 % |
| Verdict | P |
Dekorationskamin
Art.nr 36-7800 Modell ND-183-D
Användning
Obs!
Specifikationer
Nätanslutning 220–240 V AC, 50 Hz
Bruk
Obs!
Spesifikasjoner
Strømtilkobling 220–240 V AC, 50 Hz
Käyttö
△ Huom!
Tekniset tiedot
Bedienung
△ Hinweis
Technische Daten
POSTAL 10 - 13 Market Place
Kingston Upon Thames
Surrey
KT1 1JZ
DEUTSCHLAND
KUNDENSERVICE Hotline: 040 2999 78111
E-Mail: kundenservice@clasohlson.de
HOMEPAGE
www.clasohlson.de
POSTANSCHRIFT