Product Type Digital Kitchen Scale
Brand Eldom
Model TWO300
Dimensions (L x W x H) 25 x 20 x 2 cm
Net Weight 0.5 kg
Power Supply 2 x AAA batteries (included)
Display LCD, 4-digit
Maximum Capacity 5 kg
Accuracy 1 g
Units g, kg, lb:oz, fl.oz, ml
Functions Tare, Auto-off, Overload indication, Low battery indication
Platform Material Tempered glass
Platform Surface Anti-slip silicone pad
Battery Life Up to 6 months (depending on usage)
Auto-off After 2 minutes of inactivity
Cleaning Wipe with a damp cloth; do not immerse in water
Safety Features Non-slip feet, rounded edges
Spare Parts Available for battery replacement; other parts not user-serviceable
Repairability Not designed for user repair; contact Eldom support
Warranty 2 years from date of purchase
Included Accessories User manual, batteries

Frequently Asked Questions - TWO300 Eldom

How do I change the batteries in my Eldom TWO300 scale?
Open the battery compartment on the bottom of the scale. Remove old batteries and insert two new AAA batteries, ensuring correct polarity. Close the compartment securely.
What does 'Lo' mean on the display?
The 'Lo' message indicates low battery. Please replace the batteries as soon as possible to ensure accurate measurements.
How do I use the tare function?
Place an empty container on the scale, then press the TARE button. The display will reset to zero. Add ingredients to the container; the weight shown will be only the added content.
Why is my scale showing 'Err'?
The 'Err' message usually indicates an overload. Remove the item from the scale and ensure the weight does not exceed the maximum capacity of 5 kg.
How do I switch between weight units?
Press the MODE or UNIT button to cycle through available units: g, kg, lb:oz, fl.oz, ml. The selected unit will appear on the display.
Can I use the scale on carpet?
For best accuracy, place the scale on a hard, level surface. Using it on carpet may affect measurement precision.
How should I clean the scale?
Wipe the platform and body with a soft, damp cloth. Do not use abrasive cleaners or immerse the scale in water. Dry thoroughly before next use.
The scale turns off automatically. Can I change this?
No, the auto-off feature is fixed at 2 minutes of inactivity to conserve battery life. Simply press any button to turn it back on.
What is the maximum weight I can measure?
The Eldom TWO300 has a maximum capacity of 5 kg (11 lb). Exceeding this limit may damage the scale.
My scale is not turning on. What should I do?
Check the batteries: ensure they are installed correctly (polarity) and have sufficient charge. Try replacing with fresh AAA batteries. If the issue persists, contact Eldom support.

User questions about TWO300 Eldom

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Scale in PDF format for free! Find your manual TWO300 - Eldom and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TWO300 by Eldom.

USER MANUAL TWO300 Eldom

natural_image Simple line drawing of a U-shaped pipe fitting with two horizontal leads (no text or symbols)

ZMIANA JEDNOSTEK WAŻENIA

This product is specially designed to test body fat/hydration/muscle/bone help keep a close eye on the daily change of your body fat, hydration, muscle, bone, and weight, providing information for your reference. Base on the analysis of your height, weight and age etc., it tells your daily energy requirement, and helps control your weight. Please read this instruction carefully before use.

User-friendly Tips

During Measuring

A. The device is designed to allow auto step on. Please always ignore the first reading and only start taking effective record from the second time weighing.
B. Always remove your shoes and socks, wipe clean your feet before using.
C. Step on the weighing platform gently.
D. It is advisable to take measurement at the same time of the day.
E. Measured result could be misleading after intensive exercise, excessive dieting or under extreme dehydration condition.
F. Always weigh/use the scale on a hard and flat surface. When you are measuring, please keep still.
G. The measured data of the following people may have deviation:

- Children under 10 or adult over 70 (can only use the device under normal weighing mode)

- Body building athletes or other occupational athletes.

H. People with the following conditions should not use the device:

  • Pregnant women
  • Those with symptom of edema
  • Those on dialysis treatment
  • Those who use heart pacemaker or with other implanted medical device.

Safety Warning

A. The Fat% Hydration% content evaluated by the Fat Monitor Scale is only for reference (not for medical purpose). If your Fat% Hydration% content is over/below normal level, please consult your doctor for more advice.
B. Keep away from strong electro-magnetic field when using the scale.
C. It could be slippery if you weigh on a wet surface. Moreover, if the weighing platform surface is glazed, never step on the edge of the scale and do keep balance during your weighing.

Performance Index

Index\ItemWeighing CapacityFat%Hydration%Muscle%Bone%Calorie
Index Range200kg440lb4.0%~60.0%27.5%~66.0%20.0%~56.0%2.0%~20.0%
Division0.1kg0.2lb0.1%0.1%0.1%0.1%1KCAL

9V

Battery

1x9V battery (excluded). Remove package foil before use. Remove battery compartment cover at the back of device and attach new battery onto the 9-volt battery snaps. Please observe the polarity.

Eldom TWO300 - Battery - 1

natural_image Simple line drawing of a U-shaped pipe fitting (no text or symbols)

To Set Weight Unit

If your scale is available (or applicable) in kg/lb/st, you can set to the one you prefer by pressing the unit conversion button. Press the unit conversion button when scale is power off, LCD shows current weight unit.

After selecting the preferred unit, the scale will be auto-off after 3 seconds. Selected weight unit will be activated when the scale is turned on again.

  • When setting lb/st as weight unit, the default height unit is feet/inch;
  • When setting kg as weight unit, the default height unit is cm.

At the bottom of scale, you can find a unit conversion button as shown in picture.

LCD Display Muscle% Fat% Height Unit Hydration% Bone% Age Weight Unit Code 10 88.8 cm 1/2 88.8 Age st:lb kg KCAL Fat status indication Calorie Unit Gender User memory code

Key Illustration

ON/ SET Turn on the scale and prompt to next parameter. (Please refer to the Setting Personal Parameter overleaf)

▲ Advance the value by one interval each press. Continuous pressing will speed up the advance of value.
Decrease the value by one interval each press. Continuous presing will speed up the decrease of value

START Start testing

Optional Normal Weighing Mode (by passing parameter setting)

Eldom TWO300 - Optional Normal Weighing Mode (by passing parameter setting) - 1

flowchart
graph LR
    A["Install battery, and place the scale on flat floor"] -->|Step on the weighing platform| B["Display your weight"]
    B --> C["Digits flash, stabilized and locked"]

Fat/Hydration/Muscle/Bone/Calorie/Measuring Mode

At the first time when you install battery and switch on, all default parameter are set as follow:

GenderHeightAge
Male165 cm/ 5'05.0"25

Parameters can be set in the following range:

MemoryGenderHeightAge
1-12male/female100-250 cm3'03.5"-8'02.5"10-100

Example: the 5th user, female, 166cm, 26 years old can set her parameters as follow:

Eldom TWO300 - Fat/Hydration/Muscle/Bone/Calorie/Measuring Mode - 1

flowchart
graph TD
    A["Power off"] --> B["Press ON/SET(SET) to switch on"]
    B --> C["Default parameters"]
    C --> D["Press to select user code"]
    D --> E["Press to select gender"]
    E --> F["Press ON/SET(SET) to confirm and prompt to next setting"]
    F --> G["Press ON/SET(SET) to confirm and prompt to next setting"]
    G --> H["Press ON/SET(SET) to set height"]
    H --> I["Press ON/SET(SET) to confirm and prompt to next setting"]
    I --> J["Press START or tap slightly on the scale platform and release"]
    J --> K["LCD shows last measured record. No record in the first time of use"]
    K --> L["LCD shows "0.0""]
    L --> M["Scale shuts off automatically after 8 seconds"]
    M --> N["Personal parameters have been saved"]

Note:
During parameter setting, you can always tap on the scale platform by your hand or your foot any time to set the scale to zero-point. You can start measuring body fat/hydration based on the parameters just set/updated into the scale.
After completing the setting cycle, you can always continue on pressing SET again to go through another setting cycle of all parameters..

To Start Measuring

To ensure accuracy, please remove your shoes & socks before stepping on.

Example: the 5th user, female, 166cm, 26 years old can measure as follow:

Eldom TWO300 - To Start Measuring - 1

flowchart
graph TD
    A["Power off"] --> B["Press ONSET (SET) to switch on"]
    B --> C["165° 25° Show parameters of the last user or default parameters"]
    C --> D["Press to select user code or reset parameters"]
    D --> E["5 166° 26°"]
    E --> F["Press START or tap slightly at the lower corner of scale"]
    F --> G["If personal parameter amended, the body fat status may be different."]
    G --> H["Wait until LCD shows "0.0""]
    H --> I["LCD shows "0.0""]
    I --> J["Step onto weighing platform gently"]
    J --> K["Your current weight"]
    K --> L["Wait until the digits stabilize"]
    L --> M["5 558 kg Weight readings locked and flash once"]
    M --> N["Prompt to body fat measuring mode"]
    N --> O["Display result"]
    O --> P["5 238% 523% 558 kg Fat%, Hydration% and Weight"]
    P --> Q["5 372% 120% 1840 kcal Muscle%, Bone% and Calorieintake suggestion"]
    Q --> R["Shut down automatically"]

Safety instructions:

This appliance is only intended for domestic use.

Do not step on the scale when it is wet.

- Do not step on the scale with wet feet.

■ Store the scale in dark and dry place.

During storage do not place any other items on it.

The precision of the scales indications depends on the way it is operated.

Use it carefully. Do not jump on the scale or drop it.

■ Clean with moist soft cloth without using chemical detergents.

Clean dry. Do not immerse in water.

Only authorized service point can make any repairs. Any modernizations or using the spare parts or elements other that original is not allowed and can be dangerous to life.

Warning Indications

lo

Err

|Err-l|

Err-h

Eldom TWO300 - Warning Indications - 5

Low Battery Indication.

The battery power is running low, please replace with a new battery.

Over-load Indication

The weighing subject on the platform exceeds the maximum capability of scale. Please step off to avoid damage.

Low Fat% Indication

The Fat% is too low. Please lead a more nutritional diet and take good care of yourself.

High Fat% Indication

The Fat% is too high. Please watch your diet and do more exercise.

Re-test

Error exists, please re-test to get the correct result.

About Fat

1. About Fat%

Fat% is an index % of fat content in human body.

The fat content in human body is of a certain level, overabundance of fat will bring bad effects of metabolism, thereby, various illnesses may invade. Here goes an old saying, Obesity is hotbed of illness.

2. Working Principles

As electrical signal of certain frequency transmits through human body, the impedance of fat is stronger than that of muscle or other human tissues. Through the use of biological resistance analysis, this product will pass a safe frequency of low voltage electrical current through human body, thus, the Fat% will be reflected according to the resistance differences when the electrical signal transmitting through human body.

3. Fat/Hydration Content Fitness Assessment Chart

After your weighing, you can use the following Assessment Chart for reference:

AgeFat(F)Hydration(F)Fat(M)Hydration(M)StatusKey Line Indication
≤304.0-16.0%66.0-57.8%4.0-11.0%66.0-61.2%Too leaniii
16.1-20.5%57.7-54.7%11.1-15.5%61.1-58.1%Leaniii iii
20.6-25.0%54.6-51.6%15.6-20.0%58.0-55.0%Normaliii iii iii
25.1-30.5%51.5-47.8%20.1-24.5%54.9-51.9%Fatiii iii iii iii
30.6-60.0%47.7-27.5%24.6-60.0%51.8-27.5%Too fatiii iii iii iii iii
>304.0-20.0%66.0-55.0%4.0-15.0%66.0-58.4%Too leaniii
20.1-25.0%54.9-51.6%15.1-19.5%58.3-55.3%Leaniii iii
25.1-30.0%51.5-48.1%19.6-24.0%55.2-52.3%Normaliii iii iii
30.1-35.0%48.0-44.7%24.1-28.5%52.2-49.2%Fatiii iii iii iii
35.1-60.0%44.6-27.5%28.6-60.0%49.1-27.5%Too fatiii iii iii iii iii

• The above information is only for reference

ENVIRONMENTAL PROTECTION

  • the appliance is made of materials which can be recycled,
  • it should be handed over to the applicable collection point for the recycling of electrical and electronic equipment
natural_image Illustration of a 3D rectangular device with a 9V label and internal components (no readable text or symbols)

Baterie

natural_image Simple line drawing of a U-shaped pipe fitting (no text or symbols)
natural_image Illustration of a 3D rectangular device with a 9V label and internal components (no readable text or symbols)

BATERIEN

natural_image Simple line drawing of a U-shaped pipe fitting (no text or symbols)
natural_image Illustration of a 3D rectangular object with a 9V label and internal components (no readable text or symbols)

ПИТАНИЕ

natural_image Simple line drawing of a U-shaped pipe or handle with two parallel tubes (no text or symbols)
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Eldom

Model : TWO300

Category : Scale