TWO300 - Scale Eldom - Free user manual and instructions
Find the device manual for free TWO300 Eldom in PDF.
| Product Type | Digital Kitchen Scale |
| Brand | Eldom |
| Model | TWO300 |
| Dimensions (L x W x H) | 25 x 20 x 2 cm |
| Net Weight | 0.5 kg |
| Power Supply | 2 x AAA batteries (included) |
| Display | LCD, 4-digit |
| Maximum Capacity | 5 kg |
| Accuracy | 1 g |
| Units | g, kg, lb:oz, fl.oz, ml |
| Functions | Tare, Auto-off, Overload indication, Low battery indication |
| Platform Material | Tempered glass |
| Platform Surface | Anti-slip silicone pad |
| Battery Life | Up to 6 months (depending on usage) |
| Auto-off | After 2 minutes of inactivity |
| Cleaning | Wipe with a damp cloth; do not immerse in water |
| Safety Features | Non-slip feet, rounded edges |
| Spare Parts | Available for battery replacement; other parts not user-serviceable |
| Repairability | Not designed for user repair; contact Eldom support |
| Warranty | 2 years from date of purchase |
| Included Accessories | User manual, batteries |
Frequently Asked Questions - TWO300 Eldom
User questions about TWO300 Eldom
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Scale in PDF format for free! Find your manual TWO300 - Eldom and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TWO300 by Eldom.
USER MANUAL TWO300 Eldom
natural_image
Simple line drawing of a U-shaped pipe fitting with two horizontal leads (no text or symbols)ZMIANA JEDNOSTEK WAŻENIA
This product is specially designed to test body fat/hydration/muscle/bone help keep a close eye on the daily change of your body fat, hydration, muscle, bone, and weight, providing information for your reference. Base on the analysis of your height, weight and age etc., it tells your daily energy requirement, and helps control your weight. Please read this instruction carefully before use.
User-friendly Tips
During Measuring
A. The device is designed to allow auto step on. Please always ignore the first reading and only start taking effective record from the second time weighing.
B. Always remove your shoes and socks, wipe clean your feet before using.
C. Step on the weighing platform gently.
D. It is advisable to take measurement at the same time of the day.
E. Measured result could be misleading after intensive exercise, excessive dieting or under extreme dehydration condition.
F. Always weigh/use the scale on a hard and flat surface. When you are measuring, please keep still.
G. The measured data of the following people may have deviation:
- Children under 10 or adult over 70 (can only use the device under normal weighing mode)
- Body building athletes or other occupational athletes.
H. People with the following conditions should not use the device:
- Pregnant women
- Those with symptom of edema
- Those on dialysis treatment
- Those who use heart pacemaker or with other implanted medical device.
Safety Warning
A. The Fat% Hydration% content evaluated by the Fat Monitor Scale is only for reference (not for medical purpose). If your Fat% Hydration% content is over/below normal level, please consult your doctor for more advice.
B. Keep away from strong electro-magnetic field when using the scale.
C. It could be slippery if you weigh on a wet surface. Moreover, if the weighing platform surface is glazed, never step on the edge of the scale and do keep balance during your weighing.
Performance Index
| Index\Item | Weighing Capacity | Fat% | Hydration% | Muscle% | Bone% | Calorie |
| Index Range | 200kg440lb | 4.0%~60.0% | 27.5%~66.0% | 20.0%~56.0% | 2.0%~20.0% | |
| Division | 0.1kg0.2lb | 0.1% | 0.1% | 0.1% | 0.1% | 1KCAL |

Battery
1x9V battery (excluded). Remove package foil before use. Remove battery compartment cover at the back of device and attach new battery onto the 9-volt battery snaps. Please observe the polarity.

natural_image
Simple line drawing of a U-shaped pipe fitting (no text or symbols)To Set Weight Unit
If your scale is available (or applicable) in kg/lb/st, you can set to the one you prefer by pressing the unit conversion button. Press the unit conversion button when scale is power off, LCD shows current weight unit.
After selecting the preferred unit, the scale will be auto-off after 3 seconds. Selected weight unit will be activated when the scale is turned on again.
- When setting lb/st as weight unit, the default height unit is feet/inch;
- When setting kg as weight unit, the default height unit is cm.
At the bottom of scale, you can find a unit conversion button as shown in picture.

Key Illustration
ON/ SET Turn on the scale and prompt to next parameter. (Please refer to the Setting Personal Parameter overleaf)
▲ Advance the value by one interval each press. Continuous pressing will speed up the advance of value.
Decrease the value by one interval each press.
Continuous presing will speed up the decrease of value
START Start testing
Optional Normal Weighing Mode (by passing parameter setting)

flowchart
graph LR
A["Install battery, and place the scale on flat floor"] -->|Step on the weighing platform| B["Display your weight"]
B --> C["Digits flash, stabilized and locked"]
Fat/Hydration/Muscle/Bone/Calorie/Measuring Mode
At the first time when you install battery and switch on, all default parameter are set as follow:
| Gender | Height | Age |
| Male | 165 cm/ 5'05.0" | 25 |
Parameters can be set in the following range:
| Memory | Gender | Height | Age | |
| 1-12 | male/female | 100-250 cm3'03.5"-8'02.5" | 10-100 | |
Example: the 5th user, female, 166cm, 26 years old can set her parameters as follow:

flowchart
graph TD
A["Power off"] --> B["Press ON/SET(SET) to switch on"]
B --> C["Default parameters"]
C --> D["Press to select user code"]
D --> E["Press to select gender"]
E --> F["Press ON/SET(SET) to confirm and prompt to next setting"]
F --> G["Press ON/SET(SET) to confirm and prompt to next setting"]
G --> H["Press ON/SET(SET) to set height"]
H --> I["Press ON/SET(SET) to confirm and prompt to next setting"]
I --> J["Press START or tap slightly on the scale platform and release"]
J --> K["LCD shows last measured record. No record in the first time of use"]
K --> L["LCD shows "0.0""]
L --> M["Scale shuts off automatically after 8 seconds"]
M --> N["Personal parameters have been saved"]
Note:
During parameter setting, you can always tap on the scale platform by your hand or your foot any time to set the scale to zero-point. You can start measuring body fat/hydration based on the parameters just set/updated into the scale.
After completing the setting cycle, you can always continue on pressing SET again to go through another setting cycle of all parameters..
To Start Measuring
To ensure accuracy, please remove your shoes & socks before stepping on.
Example: the 5th user, female, 166cm, 26 years old can measure as follow:

flowchart
graph TD
A["Power off"] --> B["Press ONSET (SET) to switch on"]
B --> C["165° 25° Show parameters of the last user or default parameters"]
C --> D["Press to select user code or reset parameters"]
D --> E["5 166° 26°"]
E --> F["Press START or tap slightly at the lower corner of scale"]
F --> G["If personal parameter amended, the body fat status may be different."]
G --> H["Wait until LCD shows "0.0""]
H --> I["LCD shows "0.0""]
I --> J["Step onto weighing platform gently"]
J --> K["Your current weight"]
K --> L["Wait until the digits stabilize"]
L --> M["5 558 kg Weight readings locked and flash once"]
M --> N["Prompt to body fat measuring mode"]
N --> O["Display result"]
O --> P["5 238% 523% 558 kg Fat%, Hydration% and Weight"]
P --> Q["5 372% 120% 1840 kcal Muscle%, Bone% and Calorieintake suggestion"]
Q --> R["Shut down automatically"]
Safety instructions:
This appliance is only intended for domestic use.
Do not step on the scale when it is wet.
- Do not step on the scale with wet feet.
■ Store the scale in dark and dry place.
During storage do not place any other items on it.
The precision of the scales indications depends on the way it is operated.
Use it carefully. Do not jump on the scale or drop it.
■ Clean with moist soft cloth without using chemical detergents.
Clean dry. Do not immerse in water.
Only authorized service point can make any repairs. Any modernizations or using the spare parts or elements other that original is not allowed and can be dangerous to life.
Warning Indications





Low Battery Indication.
The battery power is running low, please replace with a new battery.
Over-load Indication
The weighing subject on the platform exceeds the maximum capability of scale. Please step off to avoid damage.
Low Fat% Indication
The Fat% is too low. Please lead a more nutritional diet and take good care of yourself.
High Fat% Indication
The Fat% is too high. Please watch your diet and do more exercise.
Re-test
Error exists, please re-test to get the correct result.
About Fat
1. About Fat%
Fat% is an index % of fat content in human body.
The fat content in human body is of a certain level, overabundance of fat will bring bad effects of metabolism, thereby, various illnesses may invade. Here goes an old saying, Obesity is hotbed of illness.
2. Working Principles
As electrical signal of certain frequency transmits through human body, the impedance of fat is stronger than that of muscle or other human tissues. Through the use of biological resistance analysis, this product will pass a safe frequency of low voltage electrical current through human body, thus, the Fat% will be reflected according to the resistance differences when the electrical signal transmitting through human body.
3. Fat/Hydration Content Fitness Assessment Chart
After your weighing, you can use the following Assessment Chart for reference:
| Age | Fat(F) | Hydration(F) | Fat(M) | Hydration(M) | Status | Key Line Indication |
| ≤30 | 4.0-16.0% | 66.0-57.8% | 4.0-11.0% | 66.0-61.2% | Too lean | iii |
| 16.1-20.5% | 57.7-54.7% | 11.1-15.5% | 61.1-58.1% | Lean | iii iii | |
| 20.6-25.0% | 54.6-51.6% | 15.6-20.0% | 58.0-55.0% | Normal | iii iii iii | |
| 25.1-30.5% | 51.5-47.8% | 20.1-24.5% | 54.9-51.9% | Fat | iii iii iii iii | |
| 30.6-60.0% | 47.7-27.5% | 24.6-60.0% | 51.8-27.5% | Too fat | iii iii iii iii iii | |
| >30 | 4.0-20.0% | 66.0-55.0% | 4.0-15.0% | 66.0-58.4% | Too lean | iii |
| 20.1-25.0% | 54.9-51.6% | 15.1-19.5% | 58.3-55.3% | Lean | iii iii | |
| 25.1-30.0% | 51.5-48.1% | 19.6-24.0% | 55.2-52.3% | Normal | iii iii iii | |
| 30.1-35.0% | 48.0-44.7% | 24.1-28.5% | 52.2-49.2% | Fat | iii iii iii iii | |
| 35.1-60.0% | 44.6-27.5% | 28.6-60.0% | 49.1-27.5% | Too fat | iii iii iii iii iii | |
• The above information is only for reference
ENVIRONMENTAL PROTECTION
- the appliance is made of materials which can be recycled,
- it should be handed over to the applicable collection point for the recycling of electrical and electronic equipment