USER MANUAL TL-A5122 Vevor

TechnicalSupportandE-WarrantyCertificate

www.vevor.com/support

AIR HYDRAULIC PUMP USER MANUAL

MODEL: TL-A5122

Wecontinuetobecommittedtoprovideyoutoolswithcompetitiveprice. "SaveHalf", "HalfPrice"oranyothersimilarexpressionsusedbyusonly representsanestimateofsavingsyoumightbenefitfrombuyingcertaintools withuscomparedtothemajortopbrandsanddoesnotnecessarilymeantocover allcategoriesoftoolsofferedbyus.Youarekindlyremindedtoverifycarefull whenyouareplacinganorderwithusifyouareactuallySaving Halfincomparisonwiththetopmajorbrands.

y

MODEL: TL-A5122

Vevor TL-A5122 - MODEL: TL-A5122 - 1

natural_image Black and silver electric shock absorber device with metallic casing and ventilation slots (no text or symbols visible)

(Thepictureisforreferenceonly, pleaserefertotheactualobject)

NEED HELP? CONTACT US!

Haveproductquestions?Needtechnicalsupport?Pleasefeelfreeto contactus:

Technical Support and E-Warranty Certificate www.vevor.com/support

Thisistheoriginalinstruction, pleasereadallmanualinstructions carefullybeforeoperating.VEVORreservesaclearinterpretationofour usermanual.Theappearanceoftheproductshallbesubjecttothe productyoureceived.Pleaseforgiveusthatwewon'tinformyouagainif thereareanytechnologyorsoftwareupdatesonourproduct.

Vevor TL-A5122 - NEED HELP? CONTACT US! - 1

Warning-Toreducetheriskofinjury, usermustreadinstructions manualcarefully.

Repair Parts Sheets for hydraulic air hydraulic pumps are available from your nearest authorized EAGLE PRO Service Center or EAGLE PRO Sales office.

Vevor TL-A5122 - NEED HELP? CONTACT US! - 2

natural_image Black and silver electric shock absorber device with metallic housing (no visible text or symbols)

NOTE

PLEASE READ AND FOLLOW THIS INSTRUCTION BEFORE YOU USE EAGLE PRO AIR HYDRAULIC PUMPS.

Carefully inspect all components for shipping damage. If shipping damage is found, notify carrier at once. The carrier is responsible for any damage resulting from shipment.

1. SAFETY

Vevor TL-A5122 - SAFETY - 1

To avoid personal injury or property damage, please follow all safety precautions. EAGLE PRO cannot be responsible for injury or damage resulting from unsafe and incorrect products use or system operation, or lack of maintenance.

DANGER is used when your action or lack of action may cause serious injury or even death. WARNING indicates a potential danger that requires correct action to avoid personal injury. IMPORTANT indicates correct action to prevent damage or equipment failure.

Vevor TL-A5122 - SAFETY - 2

DANGER

The hydraulic equipment operator must be a qualified operator with correct training and work experience with hydraulic equipment. Lack of knowledge in any of these areas can lead to equipment damage or personal injury.
To avoid personal injury, please do not modify or weld hydraulic equipment without approval of EAGLE PRO.
✗ Never lift a more than the rated capacity of the cylinder, overloading causes equipment failure and serious personal injury.

✗ The cylinder is a load lifting device, not a load holding device. After the load has been raised or lowered, it must always be held mechanically, never work under a load supported by a hydraulic unit.

Keep hands and feet away from cylinder and workplace during operation to avoid personal injury.

Do not put unbalanced or off-center loads on cylinders. The incorrect load can result in equipment failure and serious personal injury.

Vevor TL-A5122 - DANGER - 1

WARNING

※ Wear safety glasses, helmet and other necessary personal protective equipment when operating hydraulic equipment.

Cylinder used to lift load must have solid footing for correct support. Please select steel or wood blocks that are capable of supporting the load.

Install Pressure gauges in the system to monitor the operating pressure. The gauge must have the same pressure rating as the pump and cylinder. The wrong gauges may result in personal injury.

The system operating pressure must lower than the lowest rated pressure in the system.

Carefully inspect the cylinder and couplers before use cylinder. Never connect a cylinder with damaged couplers or damaged port threads. The damaged coupler or damaged port threads may cause equipment failure and possible personal injury.

Install coupler in a clean environment; prevent dirt or other debris from entering into cylinder body or tube. Dirt or other debris will damage the cylinder and result in equipment failure and possible personal injury.

Before removing or tightening hose or coupler, release hydraulic pressure in system.

✗ Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin, causing serious injury. Seek medical aid immediately if injured.

Use EAGLE PRO or other approved hydraulic oil

For hydraulic technical help or repair service. Please contact the authorized EAGLE PRO Service Center in your area. EAGLE PRO has no obligations under any warranty with respect to products that have been repaired by unauthorized personnel, modified, or damaged through misuse, abuse, accident, neglect, or mishandling.

IMPORTANT

Keep the air hydraulic pump clean at all time.

When the Air hydraulic pump is not in use, release the valve, remove hose and use rubber cap to recover the port.

Do not drop objects on hose.

Do not lift or carry hydraulic equipment by the hoses or couplers, use the handle or other means.

Use hydraulic equipment in normal operating temperatures. Do not use equipment in temperatures of 65 °C (150°F) or higher. Overheating will soften seals and weakens hose material, resulting in oil leaking or other equipment failure.

2. DESCRIPTION

Air Hydraulic Pump supplies hydraulic fluid pressure to selected tools. It consists of an in-line air and hydraulic cylinder.

SPECIFICATIONS

ModelPressure Rating (psi)Useable Oil Capacity (cu.in)Input Air pressure (psi)Input Port Threads (NPT)Output port Threads (NPT)Oil Delivery (cu.in / min)Operational MannerWeight Ibs
No loadload
TL-A512210,00030.590-1451/4 -183/8 -1849.57.6Foot Pedal13.2

3. BEFORE USE

Note: Always secure threaded port connections with non-hardening pipe thread compound. Tighten securely to prevent accidental removal of components while in use. Take care not to introduce thread compound into port openings.

Familiarize yourself with the specifications and illustrations in this operator 扭 manual. Know your pump, its limitations and how it operates before attempting to use. Refer to Specification chart on above for details of oil port thread size, usable oil capacity, and other information.

4. OPERATION

Operation of the pump as follow:

Connect the hose of the Air Hydraulic pump to the hydraulic coupling on the selected tool.

Connect the air supply line to the Air Hydraulic pump. Air supply should be 5-10 CFM at 100 PSI to obtain proper operating characteristic. The air line should be equipped with an air line filter.

※ To Advance, hold or Retract

Foot Pedal operates pumps:

a. Depress the Pump end of pedal will pump hydraulic oil to the system.

b. Stop depressing the Pump or Release end will stop and hold the pressure.

c. Depress the Release end of pedal will release the pressure in the system.

Vevor TL-A5122 - OPERATION - 1

text_image PUMP Air input port RELEASE Hydraulic Oil output port

5. MAINTENANCE

5.1 Inspect the connections

Inspect hoses and connections, tighten connections as needed. Use non-hardening pipe thread compound when servicing connections.

5.2 Adding Hydraulic Fluid

✗ Depressurize and disconnect hydraulic hose from application.

✗ Remove the oil filler plug located on the side of the reservoir.
Use a small funnel to fill reservoir.
Wipe up any spilled fluid and reinstall the oil filler plug.

Vevor TL-A5122 - Adding Hydraulic Fluid - 1

natural_image Close-up of a mechanical component with a white flange and bolted end, no visible text or symbols

Note: Use only EAGLE PRO or other approved hydraulic oil. Never use brake fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin etc. Use of other than good quality hydraulic oil will void warranty and damage the pump, hose and application.

5.3 Changing Hydraulic Fluid

For best results, change fluid once a year.
※ Repeat step 5.2 above, and then pour used fluid into a sealable container.
☒ Dispose of fluid in accordance with local regulations.
Fill with good quality hydraulic oil as recommended above. Reinstall vented oil filler plug.

5.4 Lubrication

Use a light machine oil to lubricate pivot points, hinges etc.

5.5 Storage

✗ Depressurize and disconnect hydraulic hoses from application.
✗ Clean the pump and hose and couplers
Store in clean dry environment, avoid temperature extremes.

6. TROUBLE SHOOTING

Vevor TL-A5122 - TROUBLE SHOOTING - 1

IMPORTANT: EAGLE PRO air hydraulic pumps should be repaired only by a qualified operator or Authorized EAGLE PRO Service Centers. Repairing air hydraulic pumps without special tools and knowledge may result in personal injury.

Always release pressure and disconnect hose(s) before making repairs.

SymptomPossible CausesCorrective Action
Application will not extend, move or respond to pressurized fluidOverload conditionRelease valve not closedRemedy overload conditionEnsure release valve closed
Application responds to pressurized fluid, but system does not maintain pressureOverload conditionRelease valve not closedHydraulic unit malfunctionRemedy overload conditionEnsure release valve closed
Application will not return fluid to pump (i.e. cylinder will not retract)Malfunctioning couplerReservoir overfilledSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/ or application, then renew or replaceSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/ or application, then drain fluid to proper level
Application will not fully extend (cylinder or spreader)Fluid level lowFollow symptom 3 procedure for securing load, depressurizing pump, remove application, then ensure proper fluid level
Poor performanceAir trapped in systemEnsure proper fluid levelEnsure vented oil filler plug let pressurized reservoir air escape (see BEFORE USE)

Manufacturer: Shanghaimuxinmuyeyouxiangongsi

Address: Shuangchenglu803nong11hao1602A-1609shi,baoshanqu,shanghai200000CN.

Imported to AUS: SIHAO PTY LTD, 1 ROKEVA STREETEASTWOOD NSW 2122 Australia

Imported to USA: Sanven Technology Ltd., Suite 250, 9166 Anaheim Place, RanchoCucamonga, CA91730

REPE

E-CrossStuGmbH

MainzerLandstr.69,60329FrankfurtamMain.

REPU

YHCONSULTINGLIMITED.

K/OYHConsultingLimitedOffice147,CenturionHouse,

LondonRoad, Staines-upon-Thames, Surrey, TW184AX

VEVOR®

TOUGH TOOLS, HALF PRICE

Technical Support and E-Warranty Certificate www.vevor.com/support

VEVOR®

TOUGH TOOLS, HALF PRICE

natural_image Black and silver electric shock absorber device with metallic casing and ventilation slots (no text or symbols visible)

Repair Parts Sheets for hydraulic air hydraulic pumps are available from your nearest authorized EAGLE PRO Service Center or EAGLE PRO Sales office.

Vevor TL-A5122 - TOUGH TOOLS, HALF PRICE - 1

natural_image Black and silver electric shock absorber device with metallic casing and handle (no visible text or symbols)

NOTE

PLEASE READ AND FOLLOW THIS INSTRUCTION BEFORE YOU USE EAGLE PRO AIR HYDRAULIC PUMPS.

Carefully inspect all components for shipping damage. If shipping damage is found, notify carrier at once. The carrier is responsible for any damage resulting from shipment.

1. SAFETY

Vevor TL-A5122 - SAFETY - 1

To avoid personal injury or property damage, please follow all safety precautions. EAGLE PRO cannot be responsible for injury or damage resulting from unsafe and incorrect products use or system operation, or lack of maintenance.

DANGER is used when your action or lack of action may cause serious injury or even death. WARNING indicates a potential danger that requires correct action to avoid personal injury. IMPORTANT indicates correct action to prevent damage or equipment failure.

Vevor TL-A5122 - SAFETY - 2

DANGER

The hydraulic equipment operator must be a qualified operator with correct training and work experience with hydraulic equipment. Lack of knowledge in any of these areas can lead to equipment damage or personal injury.
To avoid personal injury, please do not modify or weld hydraulic equipment without approval of EAGLE PRO.
✗ Never lift a more than the rated capacity of the cylinder, overloading causes equipment failure and serious personal injury.

✗ The cylinder is a load lifting device, not a load holding device. After the load has been raised or lowered, it must always be held mechanically, never work under a load supported by a hydraulic unit.

Keep hands and feet away from cylinder and workplace during operation to avoid personal injury.

Do not put unbalanced or off-center loads on cylinders. The incorrect load can result in equipment failure and serious personal injury.

Vevor TL-A5122 - DANGER - 1

WARNING

※ Wear safety glasses, helmet and other necessary personal protective equipment when operating hydraulic equipment.

Cylinder used to lift load must have solid footing for correct support. Please select steel or wood blocks that are capable of supporting the load.

Install Pressure gauges in the system to monitor the operating pressure. The gauge must have the same pressure rating as the pump and cylinder. The wrong gauges may result in personal injury.

The system operating pressure must lower than the lowest rated pressure in the system.

Carefully inspect the cylinder and couplers before use cylinder. Never connect a cylinder with damaged couplers or damaged port threads. The damaged coupler or damaged port threads may cause equipment failure and possible personal injury.

Install coupler in a clean environment; prevent dirt or other debris from entering into cylinder body or tube. Dirt or other debris will damage the cylinder and result in equipment failure and possible personal injury.

Before removing or tightening hose or coupler, release hydraulic pressure in system.

Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin, causing serious injury. Seek medical aid immediately if injured.

Use EAGLE PRO or other approved hydraulic oil

For hydraulic technical help or repair service. Please contact the authorized EAGLE PRO Service Center in your area. EAGLE PRO has no obligations under any warranty with respect to products that have been repaired by unauthorized personnel, modified, or damaged through misuse, abuse, accident, neglect, or mishandling.

IMPORTANT

Keep the air hydraulic pump clean at all time.

When the Air hydraulic pump is not in use, release the valve, remove hose and use rubber cap to recover the port.

Do not drop objects on hose.

Do not lift or carry hydraulic equipment by the hoses or couplers, use the handle or other means.

Use hydraulic equipment in normal operating temperatures. Do not use equipment in temperatures of 65 °C (150°F) or higher. Overheating will soften seals and weakens hose material, resulting in oil leaking or other equipment failure.

2. DESCRIPTION

Air Hydraulic Pump supplies hydraulic fluid pressure to selected tools. It consists of an in-line air and hydraulic cylinder.

SPECIFICATIONS

ModelPressure Rating (psi)Useable Oil Capacity (cu.in)Input Air pressure (psi)Input Port Threads (NPT)Output port Threads (NPT)Oil Delivery (cu.in / min)Operational MannerWeight lbs
No loadload
TL-A512210,00030.590-1451/4 -183/8 -1849.57.6Foot Pedal13.2

3. BEFORE USE

Note: Always secure threaded port connections with non-hardening pipe thread compound. Tighten securely to prevent accidental removal of components while in use. Take care not to introduce thread compound into port openings.

Familiarize yourself with the specifications and illustrations in this operator 担 manual. Know your pump, its limitations and how it operates before attempting to use. Refer to Specification chart on above for details of oil port thread size, usable oil capacity, and other information.

4. OPERATION

Operation of the pump as follow:

Connect the hose of the Air Hydraulic pump to the hydraulic coupling on the selected tool.

Connect the air supply line to the Air Hydraulic pump. Air supply should be 5-10 CFM at 100 PSI to obtain proper operating characteristic. The air line should be equipped with an air line filter.

※ To Advance, hold or Retract

Foot Pedal operates pumps:

a. Depress the Pump end of pedal will pump hydraulic oil to the system.
b. Stop depressing the Pump or Release end will stop and hold the pressure.
c. Depress the Release end of pedal will release the pressure in the system.

Vevor TL-A5122 - OPERATION - 1

text_image PUMP Air input port RELEASE Hydraulic Oil output port

5. MAINTENANCE

5.1 Inspect the connections

Inspect hoses and connections, tighten connections as needed. Use non-hardening pipe thread compound when servicing connections.

5.2 Adding Hydraulic Fluid

✗ Depressurize and disconnect hydraulic hose from application.

✗ Remove the oil filler plug located on the side of the reservoir.
Use a small funnel to fill reservoir.
Wipe up any spilled fluid and reinstall the oil filler plug.

Vevor TL-A5122 - Adding Hydraulic Fluid - 1

natural_image Close-up of a mechanical component with a white flange and bolted end, showing a directional arrow (no text or symbols)

Note: Use only EAGLE PRO or other approved hydraulic oil. Never use brake fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin etc. Use of other than good quality hydraulic oil will void warranty and damage the pump, hose and application.

5.3 Changing Hydraulic Fluid

For best results, change fluid once a year.
✗ Repeat step 5.2 above, and then pour used fluid into a sealable container.
Dispose of fluid in accordance with local regulations.
Fill with good quality hydraulic oil as recommended above. Reinstall vented oil filler plug.

5.4 Lubrication

Use a light machine oil to lubricate pivot points, hinges etc.

5.5 Storage

✗ Depressurize and disconnect hydraulic hoses from application.
✗ Clean the pump and hose and couplers
Store in clean dry environment, avoid temperature extremes.

6. TROUBLE SHOOTING

Vevor TL-A5122 - TROUBLE SHOOTING - 1

IMPORTANT: EAGLE PRO air hydraulic pumps should be repaired only by a qualified operator or Authorized EAGLE PRO Service Centers. Repairing air hydraulic pumps without special tools and knowledge may result in personal injury.

Always release pressure and disconnect hose(s) before making repairs.

SymptomPossible CausesCorrective Action
Application will not extend, move or respond to pressurized fluidOverload conditionRelease valve not closedRemedy overload conditionEnsure release valve closed
Application responds to pressurized fluid, but system does not maintain pressureOverload conditionRelease valve not closedHydraulic unit malfunctionRemedy overload conditionEnsure release valve closed
Application will not return fluid to pump (i.e. cylinder will not retract)Malfunctioning couplerReservoir overfilledSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then renew or replaceSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then drain fluid to proper level
Application will not fully extend (cylinder or spreader)Fluid level lowFollow symptom 3 procedure for securing load, depressurizing pump, remove application, then ensure proper fluid level
Poor performanceAir trapped in systemEnsure proper fluid levelEnsure vented oil filler plug let pressurized reservoir air escape (see BEFORE USE)

Fabricant : Shanghaimuxinmuyeyouxiangongsi Adresse :

Shuangchenglu 803nong11hao1602A-1609shi, baoshanqu, shanghai 200000 CN.

Importé en Australie : SIHAO PTY LTD, 1 ROKEVA STREETESTWOOD NSW 2122 Australie

C/O YH Consulting Limited Bureau 147, Centurion House,

London Road, Staines-upon-Thames, Surrey, TW18 4AX

VEVOR®

TOUGH TOOLS, HALF PRICE

www.vevor.com/support

Lufthydraulikpumpe

BENUTZERHANDBUCH

MODELL: TL-A5122

natural_image Black industrial electrical plug device with metallic base and side slots (no visible text or symbols)

Repair Parts Sheets for hydraulic air hydraulic pumps are available from your nearest authorized EAGLE PRO Service Center or EAGLE PRO Sales office.

Vevor TL-A5122 - BENUTZERHANDBUCH - 1

natural_image Black and silver electric shock absorber device with metallic casing and side slots (no visible text or symbols)

NOTE

PLEASE READ AND FOLLOW THIS INSTRUCTION BEFORE YOU USE EAGLE PRO AIR HYDRAULIC PUMPS.

Carefully inspect all components for shipping damage. If shipping damage is found, notify carrier at once. The carrier is responsible for any damage resulting from shipment.

1. SAFETY

Vevor TL-A5122 - SAFETY - 1

To avoid personal injury or property damage, please follow all safety precautions. EAGLE PRO cannot be responsible for injury or damage resulting from unsafe and incorrect products use or system operation, or lack of maintenance.

DANGER is used when your action or lack of action may cause serious injury or even death. WARNING indicates a potential danger that requires correct action to avoid personal injury. IMPORTANT indicates correct action to prevent damage or equipment failure.

Vevor TL-A5122 - SAFETY - 2

DANGER

The hydraulic equipment operator must be a qualified operator with correct training and work experience with hydraulic equipment. Lack of knowledge in any of these areas can lead to equipment damage or personal injury.
To avoid personal injury, please do not modify or weld hydraulic equipment without approval of EAGLE PRO.
✗ Never lift a more than the rated capacity of the cylinder, overloading causes equipment failure and serious personal injury.

✗ The cylinder is a load lifting device, not a load holding device. After the load has been raised or lowered, it must always be held mechanically, never work under a load supported by a hydraulic unit.

Keep hands and feet away from cylinder and workplace during operation to avoid personal injury.

Do not put unbalanced or off-center loads on cylinders. The incorrect load can result in equipment failure and serious personal injury.

Vevor TL-A5122 - DANGER - 1

WARNING

※ Wear safety glasses, helmet and other necessary personal protective equipment when operating hydraulic equipment.

Cylinder used to lift load must have solid footing for correct support. Please select steel or wood blocks that are capable of supporting the load.

Install Pressure gauges in the system to monitor the operating pressure. The gauge must have the same pressure rating as the pump and cylinder. The wrong gauges may result in personal injury.

The system operating pressure must lower than the lowest rated pressure in the system.

Carefully inspect the cylinder and couplers before use cylinder. Never connect a cylinder with damaged couplers or damaged port threads. The damaged coupler or damaged port threads may cause equipment failure and possible personal injury.

Install coupler in a clean environment; prevent dirt or other debris from entering into cylinder body or tube. Dirt or other debris will damage the cylinder and result in equipment failure and possible personal injury.

Before removing or tightening hose or coupler, release hydraulic pressure in system.

Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin, causing serious injury. Seek medical aid immediately if injured.

Use EAGLE PRO or other approved hydraulic oil

For hydraulic technical help or repair service. Please contact the authorized EAGLE PRO Service Center in your area. EAGLE PRO has no obligations under any warranty with respect to products that have been repaired by unauthorized personnel, modified, or damaged through misuse, abuse, accident, neglect, or mishandling.

IMPORTANT

Keep the air hydraulic pump clean at all time.

When the Air hydraulic pump is not in use, release the valve, remove hose and use rubber cap to recover the port.

Do not drop objects on hose.

Do not lift or carry hydraulic equipment by the hoses or couplers, use the handle or other means.

Use hydraulic equipment in normal operating temperatures. Do not use equipment in temperatures of 65 °C (150°F) or higher. Overheating will soften seals and weakens hose material, resulting in oil leaking or other equipment failure.

2. DESCRIPTION

Air Hydraulic Pump supplies hydraulic fluid pressure to selected tools. It consists of an in-line air and hydraulic cylinder.

SPECIFICATIONS

ModelPressure Rating (psi)Useable Oil Capacity (cu.in)Input Air pressure (psi)Input Port Threads (NPT)Output port Threads (NPT)Oil Delivery (cu.in / min)Operational MannerWeight lbs
No loadload
TL-A512210,00030.590-1451/4 -183/8 -1849.57.6Foot Pedal13.2

3. BEFORE USE

Note: Always secure threaded port connections with non-hardening pipe thread compound. Tighten securely to prevent accidental removal of components while in use. Take care not to introduce thread compound into port openings.

Familiarize yourself with the specifications and illustrations in this operator 担 manual. Know your pump, its limitations and how it operates before attempting to use. Refer to Specification chart on above for details of oil port thread size, usable oil capacity, and other information.

4. OPERATION

Operation of the pump as follow:

Connect the hose of the Air Hydraulic pump to the hydraulic coupling on the selected tool.

Connect the air supply line to the Air Hydraulic pump. Air supply should be 5-10 CFM at 100 PSI to obtain proper operating characteristic. The air line should be equipped with an air line filter.

※ To Advance, hold or Retract

Foot Pedal operates pumps:

a. Depress the Pump end of pedal will pump hydraulic oil to the system.
b. Stop depressing the Pump or Release end will stop and hold the pressure.
c. Depress the Release end of pedal will release the pressure in the system.

Vevor TL-A5122 - OPERATION - 1

text_image PUMP Air input port RELEASE Hydraulic Oil output port

5. MAINTENANCE

5.1 Inspect the connections

Inspect hoses and connections, tighten connections as needed. Use non-hardening pipe thread compound when servicing connections.

5.2 Adding Hydraulic Fluid

✗ Depressurize and disconnect hydraulic hose from application.

✗ Remove the oil filler plug located on the side of the reservoir.
Use a small funnel to fill reservoir.
Wipe up any spilled fluid and reinstall the oil filler plug.

Vevor TL-A5122 - Adding Hydraulic Fluid - 1

natural_image Close-up of a mechanical component with a white flange and bolted end, showing a directional arrow (no text or symbols)

Note: Use only EAGLE PRO or other approved hydraulic oil. Never use brake fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin etc. Use of other than good quality hydraulic oil will void warranty and damage the pump, hose and application.

5.3 Changing Hydraulic Fluid

For best results, change fluid once a year.
✗ Repeat step 5.2 above, and then pour used fluid into a sealable container.
Dispose of fluid in accordance with local regulations.
Fill with good quality hydraulic oil as recommended above. Reinstall vented oil filler plug.

5.4 Lubrication

Use a light machine oil to lubricate pivot points, hinges etc.

5.5 Storage

✗ Depressurize and disconnect hydraulic hoses from application.
✗ Clean the pump and hose and couplers
Store in clean dry environment, avoid temperature extremes.

6. TROUBLE SHOOTING

Vevor TL-A5122 - TROUBLE SHOOTING - 1

IMPORTANT: EAGLE PRO air hydraulic pumps should be repaired only by a qualified operator or Authorized EAGLE PRO Service Centers. Repairing air hydraulic pumps without special tools and knowledge may result in personal injury.

Always release pressure and disconnect hose(s) before making repairs.

SymptomPossible CausesCorrective Action
Application will not extend, move or respond to pressurized fluidOverload conditionRelease valve not closedRemedy overload conditionEnsure release valve closed
Application responds to pressurized fluid, but system does not maintain pressureOverload conditionRelease valve not closedHydraulic unit malfunctionRemedy overload conditionEnsure release valve closed
Application will not return fluid to pump (i.e. cylinder will not retract)Malfunctioning couplerReservoir overfilledSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then renew or replaceSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then drain fluid to proper level
Application will not fully extend (cylinder or spreader)Fluid level lowFollow symptom 3 procedure for securing load, depressurizing pump, remove application, then ensure proper fluid level
Poor performanceAir trapped in systemEnsure proper fluid levelEnsure vented oil filler plug let pressurized reservoir air escape (see BEFORE USE)

Hersteller: Shanghaimuxinmuyeyouxiangongsi

Adresse: Shuangchenglu 803nong11hao1602A-1609shi, baoshanqu, Shanghai 200000 CN.

Nach AUS importiert: SIHAO PTY LTD, 1 ROKEVA STREETEASTWOOD NSW 2122 Australien

Importiert in die USA: Sanven Technology Ltd., Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730

Vertreter der EG

E-CrossStu GmbH

Mainzer Landstr.69, 60329 Frankfurt am Main.

UK REP

YH CONSULTING LIMITED.

C/O YH Consulting Limited Office 147, Centurion House,

London Road, Staines-upon-Thames, Surrey, TW18 4AX

VEVOR®

TOUGH TOOLS, HALF PRICE

elettronica www.vevor.com/support

POMPA IDRAULICA PNEUMATICA

MANUALE D'USO

MODELLO: TL-A5122

natural_image Black and silver electric shock absorber device with metallic casing and side slots (no visible text or symbols)

Repair Parts Sheets for hydraulic air hydraulic pumps are available from your nearest authorized EAGLE PRO Service Center or EAGLE PRO Sales office.

Vevor TL-A5122 - MANUALE D'USO - 1

natural_image Black industrial electrical plug device with metallic casing and side-mounted handle (no visible text or symbols)

NOTE

PLEASE READ AND FOLLOW THIS INSTRUCTION BEFORE YOU USE EAGLE PRO AIR HYDRAULIC PUMPS.

Carefully inspect all components for shipping damage. If shipping damage is found, notify carrier at once. The carrier is responsible for any damage resulting from shipment.

1. SAFETY

Vevor TL-A5122 - SAFETY - 1

To avoid personal injury or property damage, please follow all safety precautions. EAGLE PRO cannot be responsible for injury or damage resulting from unsafe and incorrect products use or system operation, or lack of maintenance.

DANGER is used when your action or lack of action may cause serious injury or even death. WARNING indicates a potential danger that requires correct action to avoid personal injury. IMPORTANT indicates correct action to prevent damage or equipment failure.

Vevor TL-A5122 - SAFETY - 2

DANGER

The hydraulic equipment operator must be a qualified operator with correct training and work experience with hydraulic equipment. Lack of knowledge in any of these areas can lead to equipment damage or personal injury.
To avoid personal injury, please do not modify or weld hydraulic equipment without approval of EAGLE PRO.
✗ Never lift a more than the rated capacity of the cylinder, overloading causes equipment failure and serious personal injury.

✗ The cylinder is a load lifting device, not a load holding device. After the load has been raised or lowered, it must always be held mechanically, never work under a load supported by a hydraulic unit.

Keep hands and feet away from cylinder and workplace during operation to avoid personal injury.

Do not put unbalanced or off-center loads on cylinders. The incorrect load can result in equipment failure and serious personal injury.

Vevor TL-A5122 - DANGER - 1

WARNING

※ Wear safety glasses, helmet and other necessary personal protective equipment when operating hydraulic equipment.

Cylinder used to lift load must have solid footing for correct support. Please select steel or wood blocks that are capable of supporting the load.

Install Pressure gauges in the system to monitor the operating pressure. The gauge must have the same pressure rating as the pump and cylinder. The wrong gauges may result in personal injury.

The system operating pressure must lower than the lowest rated pressure in the system.

Carefully inspect the cylinder and couplers before use cylinder. Never connect a cylinder with damaged couplers or damaged port threads. The damaged coupler or damaged port threads may cause equipment failure and possible personal injury.

Install coupler in a clean environment; prevent dirt or other debris from entering into cylinder body or tube. Dirt or other debris will damage the cylinder and result in equipment failure and possible personal injury.

Before removing or tightening hose or coupler, release hydraulic pressure in system.

Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin, causing serious injury. Seek medical aid immediately if injured.

Use EAGLE PRO or other approved hydraulic oil

For hydraulic technical help or repair service. Please contact the authorized EAGLE PRO Service Center in your area. EAGLE PRO has no obligations under any warranty with respect to products that have been repaired by unauthorized personnel, modified, or damaged through misuse, abuse, accident, neglect, or mishandling.

IMPORTANT

Keep the air hydraulic pump clean at all time.

When the Air hydraulic pump is not in use, release the valve, remove hose and use rubber cap to recover the port.

Do not drop objects on hose.

Do not lift or carry hydraulic equipment by the hoses or couplers, use the handle or other means.

Use hydraulic equipment in normal operating temperatures. Do not use equipment in temperatures of 65 °C (150°F) or higher. Overheating will soften seals and weakens hose material, resulting in oil leaking or other equipment failure.

2. DESCRIPTION

Air Hydraulic Pump supplies hydraulic fluid pressure to selected tools. It consists of an in-line air and hydraulic cylinder.

SPECIFICATIONS

ModelPressure Rating (psi)Useable Oil Capacity (cu.in)Input Air pressure (psi)Input Port Threads (NPT)Output port Threads (NPT)Oil Delivery (cu.in / min)Operational MannerWeight lbs
No loadload
TL-A512210,00030.590-1451/4 -183/8 -1849.57.6Foot Pedal13.2

3. BEFORE USE

Note: Always secure threaded port connections with non-hardening pipe thread compound. Tighten securely to prevent accidental removal of components while in use. Take care not to introduce thread compound into port openings.

Familiarize yourself with the specifications and illustrations in this operator 担 manual. Know your pump, its limitations and how it operates before attempting to use. Refer to Specification chart on above for details of oil port thread size, usable oil capacity, and other information.

4. OPERATION

Operation of the pump as follow:

Connect the hose of the Air Hydraulic pump to the hydraulic coupling on the selected tool.

Connect the air supply line to the Air Hydraulic pump. Air supply should be 5-10 CFM at 100 PSI to obtain proper operating characteristic. The air line should be equipped with an air line filter.

※ To Advance, hold or Retract

Foot Pedal operates pumps:

a. Depress the Pump end of pedal will pump hydraulic oil to the system.
b. Stop depressing the Pump or Release end will stop and hold the pressure.
c. Depress the Release end of pedal will release the pressure in the system.

Vevor TL-A5122 - OPERATION - 1

text_image PUMP Air input port RELEASE Hydraulic Oil output port

5. MAINTENANCE

5.1 Inspect the connections

Inspect hoses and connections, tighten connections as needed. Use non-hardening pipe thread compound when servicing connections.

5.2 Adding Hydraulic Fluid

✗ Depressurize and disconnect hydraulic hose from application.

✗ Remove the oil filler plug located on the side of the reservoir.
Use a small funnel to fill reservoir.
Wipe up any spilled fluid and reinstall the oil filler plug.

Vevor TL-A5122 - Adding Hydraulic Fluid - 1

natural_image Close-up of a mechanical component with a white flange and bolted end, showing a directional arrow (no text or symbols)

Note: Use only EAGLE PRO or other approved hydraulic oil. Never use brake fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin etc. Use of other than good quality hydraulic oil will void warranty and damage the pump, hose and application.

5.3 Changing Hydraulic Fluid

For best results, change fluid once a year.
✗ Repeat step 5.2 above, and then pour used fluid into a sealable container.
Dispose of fluid in accordance with local regulations.
Fill with good quality hydraulic oil as recommended above. Reinstall vented oil filler plug.

5.4 Lubrication

Use a light machine oil to lubricate pivot points, hinges etc.

5.5 Storage

✗ Depressurize and disconnect hydraulic hoses from application.
✗ Clean the pump and hose and couplers
Store in clean dry environment, avoid temperature extremes.

6. TROUBLE SHOOTING

Vevor TL-A5122 - TROUBLE SHOOTING - 1

IMPORTANT: EAGLE PRO air hydraulic pumps should be repaired only by a qualified operator or Authorized EAGLE PRO Service Centers. Repairing air hydraulic pumps without special tools and knowledge may result in personal injury.

Always release pressure and disconnect hose(s) before making repairs.

SymptomPossible CausesCorrective Action
Application will not extend, move or respond to pressurized fluidOverload conditionRelease valve not closedRemedy overload conditionEnsure release valve closed
Application responds to pressurized fluid, but system does not maintain pressureOverload conditionRelease valve not closedHydraulic unit malfunctionRemedy overload conditionEnsure release valve closed
Application will not return fluid to pump (i.e. cylinder will not retract)Malfunctioning couplerReservoir overfilledSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then renew or replaceSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then drain fluid to proper level
Application will not fully extend (cylinder or spreader)Fluid level lowFollow symptom 3 procedure for securing load, depressurizing pump, remove application, then ensure proper fluid level
Poor performanceAir trapped in systemEnsure proper fluid levelEnsure vented oil filler plug let pressurized reservoir air escape (see BEFORE USE)

Importato in AUS: SIHAO PTY LTD, 1 ROKEVA STREETEASTWOOD NSW 2122 Australia

C/O YH Consulting Limited Ufficio 147, Centurion House,

London Road, Staines-upon-Thames, Surrey, TW18 4AX

VEVOR®

TOUGH TOOLS, HALF PRICE

natural_image Black and silver electric shock absorber device with metallic casing and side slots (no visible text or symbols)

Repair Parts Sheets for hydraulic air hydraulic pumps are available from your nearest authorized EAGLE PRO Service Center or EAGLE PRO Sales office.

Vevor TL-A5122 - VEVOR® - 1

natural_image Black and silver electric shock absorber device with metallic casing and side slots (no visible text or symbols)

NOTE

PLEASE READ AND FOLLOW THIS INSTRUCTION BEFORE YOU USE EAGLE PRO AIR HYDRAULIC PUMPS.

Carefully inspect all components for shipping damage. If shipping damage is found, notify carrier at once. The carrier is responsible for any damage resulting from shipment.

1. SAFETY

Vevor TL-A5122 - SAFETY - 1

To avoid personal injury or property damage, please follow all safety precautions. EAGLE PRO cannot be responsible for injury or damage resulting from unsafe and incorrect products use or system operation, or lack of maintenance.

DANGER is used when your action or lack of action may cause serious injury or even death. WARNING indicates a potential danger that requires correct action to avoid personal injury. IMPORTANT indicates correct action to prevent damage or equipment failure.

Vevor TL-A5122 - SAFETY - 2

DANGER

The hydraulic equipment operator must be a qualified operator with correct training and work experience with hydraulic equipment. Lack of knowledge in any of these areas can lead to equipment damage or personal injury.
To avoid personal injury, please do not modify or weld hydraulic equipment without approval of EAGLE PRO.
✗ Never lift a more than the rated capacity of the cylinder, overloading causes equipment failure and serious personal injury.

✗ The cylinder is a load lifting device, not a load holding device. After the load has been raised or lowered, it must always be held mechanically, never work under a load supported by a hydraulic unit.

Keep hands and feet away from cylinder and workplace during operation to avoid personal injury.

Do not put unbalanced or off-center loads on cylinders. The incorrect load can result in equipment failure and serious personal injury.

Vevor TL-A5122 - DANGER - 1

WARNING

※ Wear safety glasses, helmet and other necessary personal protective equipment when operating hydraulic equipment.

Cylinder used to lift load must have solid footing for correct support. Please select steel or wood blocks that are capable of supporting the load.

Install Pressure gauges in the system to monitor the operating pressure. The gauge must have the same pressure rating as the pump and cylinder. The wrong gauges may result in personal injury.

The system operating pressure must lower than the lowest rated pressure in the system.

Carefully inspect the cylinder and couplers before use cylinder. Never connect a cylinder with damaged couplers or damaged port threads. The damaged coupler or damaged port threads may cause equipment failure and possible personal injury.

Install coupler in a clean environment; prevent dirt or other debris from entering into cylinder body or tube. Dirt or other debris will damage the cylinder and result in equipment failure and possible personal injury.

Before removing or tightening hose or coupler, release hydraulic pressure in system.

Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin, causing serious injury. Seek medical aid immediately if injured.

Use EAGLE PRO or other approved hydraulic oil

For hydraulic technical help or repair service. Please contact the authorized EAGLE PRO Service Center in your area. EAGLE PRO has no obligations under any warranty with respect to products that have been repaired by unauthorized personnel, modified, or damaged through misuse, abuse, accident, neglect, or mishandling.

IMPORTANT

Keep the air hydraulic pump clean at all time.

When the Air hydraulic pump is not in use, release the valve, remove hose and use rubber cap to recover the port.

Do not drop objects on hose.

Do not lift or carry hydraulic equipment by the hoses or couplers, use the handle or other means.

Use hydraulic equipment in normal operating temperatures. Do not use equipment in temperatures of 65 °C (150°F) or higher. Overheating will soften seals and weakens hose material, resulting in oil leaking or other equipment failure.

2. DESCRIPTION

Air Hydraulic Pump supplies hydraulic fluid pressure to selected tools. It consists of an in-line air and hydraulic cylinder.

SPECIFICATIONS

ModelPressure Rating (psi)Useable Oil Capacity (cu.in)Input Air pressure (psi)Input Port Threads (NPT)Output port Threads (NPT)Oil Delivery (cu.in / min)Operational MannerWeight lbs
No loadload
TL-A512210,00030.590-1451/4 -183/8 -1849.57.6Foot Pedal13.2

3. BEFORE USE

Note: Always secure threaded port connections with non-hardening pipe thread compound. Tighten securely to prevent accidental removal of components while in use. Take care not to introduce thread compound into port openings.

Familiarize yourself with the specifications and illustrations in this operator 担 manual. Know your pump, its limitations and how it operates before attempting to use. Refer to Specification chart on above for details of oil port thread size, usable oil capacity, and other information.

4. OPERATION

Operation of the pump as follow:

Connect the hose of the Air Hydraulic pump to the hydraulic coupling on the selected tool.

Connect the air supply line to the Air Hydraulic pump. Air supply should be 5-10 CFM at 100 PSI to obtain proper operating characteristic. The air line should be equipped with an air line filter.

※ To Advance, hold or Retract

Foot Pedal operates pumps:

a. Depress the Pump end of pedal will pump hydraulic oil to the system.
b. Stop depressing the Pump or Release end will stop and hold the pressure.
c. Depress the Release end of pedal will release the pressure in the system.

Vevor TL-A5122 - OPERATION - 1

text_image PUMP Air input port RELEASE Hydraulic Oil output port

5. MAINTENANCE

5.1 Inspect the connections

Inspect hoses and connections, tighten connections as needed. Use non-hardening pipe thread compound when servicing connections.

5.2 Adding Hydraulic Fluid

✗ Depressurize and disconnect hydraulic hose from application.

✗ Remove the oil filler plug located on the side of the reservoir.
Use a small funnel to fill reservoir.
Wipe up any spilled fluid and reinstall the oil filler plug.

Vevor TL-A5122 - Adding Hydraulic Fluid - 1

natural_image Close-up of a mechanical component with a white flange and bolted end, showing a directional arrow (no text or symbols)

Note: Use only EAGLE PRO or other approved hydraulic oil. Never use brake fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin etc. Use of other than good quality hydraulic oil will void warranty and damage the pump, hose and application.

5.3 Changing Hydraulic Fluid

For best results, change fluid once a year.
✗ Repeat step 5.2 above, and then pour used fluid into a sealable container.
Dispose of fluid in accordance with local regulations.
Fill with good quality hydraulic oil as recommended above. Reinstall vented oil filler plug.

5.4 Lubrication

Use a light machine oil to lubricate pivot points, hinges etc.

5.5 Storage

✗ Depressurize and disconnect hydraulic hoses from application.
✗ Clean the pump and hose and couplers
Store in clean dry environment, avoid temperature extremes.

6. TROUBLE SHOOTING

Vevor TL-A5122 - TROUBLE SHOOTING - 1

IMPORTANT: EAGLE PRO air hydraulic pumps should be repaired only by a qualified operator or Authorized EAGLE PRO Service Centers. Repairing air hydraulic pumps without special tools and knowledge may result in personal injury.

Always release pressure and disconnect hose(s) before making repairs.

SymptomPossible CausesCorrective Action
Application will not extend, move or respond to pressurized fluidOverload conditionRelease valve not closedRemedy overload conditionEnsure release valve closed
Application responds to pressurized fluid, but system does not maintain pressureOverload conditionRelease valve not closedHydraulic unit malfunctionRemedy overload conditionEnsure release valve closed
Application will not return fluid to pump (i.e. cylinder will not retract)Malfunctioning couplerReservoir overfilledSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then renew or replaceSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then drain fluid to proper level
Application will not fully extend (cylinder or spreader)Fluid level lowFollow symptom 3 procedure for securing load, depressurizing pump, remove application, then ensure proper fluid level
Poor performanceAir trapped in systemEnsure proper fluid levelEnsure vented oil filler plug let pressurized reservoir air escape (see BEFORE USE)

Fabricante: Shanghaimuxinmuyeyouxiangongsi

Importado a AUS: SIHAO PTY LTD, 1 ROKEVA STREETEASTWOOD NSW 2122 Australia

Importado a EE. UU.: Sanven Technology Ltd., Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730

Vevor TL-A5122 - TROUBLE SHOOTING - 2

text_image REPRESENTANTE DE LA CE

E-CrossStu GmbH

C/O YH Consulting Limited Oficina 147, Centurion House,

London Road, Staines upon Thames, Surrey, TW18 4AX

VEVOR®

TOUGH TOOLS, HALF PRICE

natural_image Black and silver electric shock absorber device with metallic casing and side slots (no visible text or symbols)

Repair Parts Sheets for hydraulic air hydraulic pumps are available from your nearest authorized EAGLE PRO Service Center or EAGLE PRO Sales office.

Vevor TL-A5122 - TOUGH TOOLS, HALF PRICE - 1

natural_image Black and silver electric shock absorber device with metallic casing and handle (no visible text or symbols)

NOTE

PLEASE READ AND FOLLOW THIS INSTRUCTION BEFORE YOU USE EAGLE PRO AIR HYDRAULIC PUMPS.

Carefully inspect all components for shipping damage. If shipping damage is found, notify carrier at once. The carrier is responsible for any damage resulting from shipment.

1. SAFETY

Vevor TL-A5122 - SAFETY - 1

To avoid personal injury or property damage, please follow all safety precautions. EAGLE PRO cannot be responsible for injury or damage resulting from unsafe and incorrect products use or system operation, or lack of maintenance.

DANGER is used when your action or lack of action may cause serious injury or even death. WARNING indicates a potential danger that requires correct action to avoid personal injury. IMPORTANT indicates correct action to prevent damage or equipment failure.

Vevor TL-A5122 - SAFETY - 2

DANGER

The hydraulic equipment operator must be a qualified operator with correct training and work experience with hydraulic equipment. Lack of knowledge in any of these areas can lead to equipment damage or personal injury.
To avoid personal injury, please do not modify or weld hydraulic equipment without approval of EAGLE PRO.
✗ Never lift a more than the rated capacity of the cylinder, overloading causes equipment failure and serious personal injury.

✗ The cylinder is a load lifting device, not a load holding device. After the load has been raised or lowered, it must always be held mechanically, never work under a load supported by a hydraulic unit.

Keep hands and feet away from cylinder and workplace during operation to avoid personal injury.

Do not put unbalanced or off-center loads on cylinders. The incorrect load can result in equipment failure and serious personal injury.

Vevor TL-A5122 - DANGER - 1

WARNING

※ Wear safety glasses, helmet and other necessary personal protective equipment when operating hydraulic equipment.

Cylinder used to lift load must have solid footing for correct support. Please select steel or wood blocks that are capable of supporting the load.

Install Pressure gauges in the system to monitor the operating pressure. The gauge must have the same pressure rating as the pump and cylinder. The wrong gauges may result in personal injury.

The system operating pressure must lower than the lowest rated pressure in the system.

Carefully inspect the cylinder and couplers before use cylinder. Never connect a cylinder with damaged couplers or damaged port threads. The damaged coupler or damaged port threads may cause equipment failure and possible personal injury.

Install coupler in a clean environment; prevent dirt or other debris from entering into cylinder body or tube. Dirt or other debris will damage the cylinder and result in equipment failure and possible personal injury.

Before removing or tightening hose or coupler, release hydraulic pressure in system.

Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin, causing serious injury. Seek medical aid immediately if injured.

Use EAGLE PRO or other approved hydraulic oil

For hydraulic technical help or repair service. Please contact the authorized EAGLE PRO Service Center in your area. EAGLE PRO has no obligations under any warranty with respect to products that have been repaired by unauthorized personnel, modified, or damaged through misuse, abuse, accident, neglect, or mishandling.

IMPORTANT

Keep the air hydraulic pump clean at all time.

When the Air hydraulic pump is not in use, release the valve, remove hose and use rubber cap to recover the port.

Do not drop objects on hose.

Do not lift or carry hydraulic equipment by the hoses or couplers, use the handle or other means.

Use hydraulic equipment in normal operating temperatures. Do not use equipment in temperatures of 65 °C (150°F) or higher. Overheating will soften seals and weakens hose material, resulting in oil leaking or other equipment failure.

2. DESCRIPTION

Air Hydraulic Pump supplies hydraulic fluid pressure to selected tools. It consists of an in-line air and hydraulic cylinder.

SPECIFICATIONS

ModelPressure Rating (psi)Useable Oil Capacity (cu.in)Input Air pressure (psi)Input Port Threads (NPT)Output port Threads (NPT)Oil Delivery (cu.in / min)Operational MannerWeight lbs
No loadload
TL-A512210,00030.590-1451/4 -183/8 -1849.57.6Foot Pedal13.2

3. BEFORE USE

Note: Always secure threaded port connections with non-hardening pipe thread compound. Tighten securely to prevent accidental removal of components while in use. Take care not to introduce thread compound into port openings.

Familiarize yourself with the specifications and illustrations in this operator 担 manual. Know your pump, its limitations and how it operates before attempting to use. Refer to Specification chart on above for details of oil port thread size, usable oil capacity, and other information.

4. OPERATION

Operation of the pump as follow:

Connect the hose of the Air Hydraulic pump to the hydraulic coupling on the selected tool.

Connect the air supply line to the Air Hydraulic pump. Air supply should be 5-10 CFM at 100 PSI to obtain proper operating characteristic. The air line should be equipped with an air line filter.

※ To Advance, hold or Retract

Foot Pedal operates pumps:

a. Depress the Pump end of pedal will pump hydraulic oil to the system.
b. Stop depressing the Pump or Release end will stop and hold the pressure.
c. Depress the Release end of pedal will release the pressure in the system.

Vevor TL-A5122 - OPERATION - 1

text_image PUMP Air input port RELEASE Hydraulic Oil output port

5. MAINTENANCE

5.1 Inspect the connections

Inspect hoses and connections, tighten connections as needed. Use non-hardening pipe thread compound when servicing connections.

5.2 Adding Hydraulic Fluid

✗ Depressurize and disconnect hydraulic hose from application.

✗ Remove the oil filler plug located on the side of the reservoir.
Use a small funnel to fill reservoir.
Wipe up any spilled fluid and reinstall the oil filler plug.

Vevor TL-A5122 - Adding Hydraulic Fluid - 1

natural_image Close-up of a mechanical component with a white flange and bolted end, showing a directional arrow (no text or symbols)

Note: Use only EAGLE PRO or other approved hydraulic oil. Never use brake fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin etc. Use of other than good quality hydraulic oil will void warranty and damage the pump, hose and application.

5.3 Changing Hydraulic Fluid

For best results, change fluid once a year.
✗ Repeat step 5.2 above, and then pour used fluid into a sealable container.
Dispose of fluid in accordance with local regulations.
Fill with good quality hydraulic oil as recommended above. Reinstall vented oil filler plug.

5.4 Lubrication

Use a light machine oil to lubricate pivot points, hinges etc.

5.5 Storage

✗ Depressurize and disconnect hydraulic hoses from application.
✗ Clean the pump and hose and couplers
Store in clean dry environment, avoid temperature extremes.

6. TROUBLE SHOOTING

Vevor TL-A5122 - TROUBLE SHOOTING - 1

IMPORTANT: EAGLE PRO air hydraulic pumps should be repaired only by a qualified operator or Authorized EAGLE PRO Service Centers. Repairing air hydraulic pumps without special tools and knowledge may result in personal injury.

Always release pressure and disconnect hose(s) before making repairs.

SymptomPossible CausesCorrective Action
Application will not extend, move or respond to pressurized fluidOverload conditionRelease valve not closedRemedy overload conditionEnsure release valve closed
Application responds to pressurized fluid, but system does not maintain pressureOverload conditionRelease valve not closedHydraulic unit malfunctionRemedy overload conditionEnsure release valve closed
Application will not return fluid to pump (i.e. cylinder will not retract)Malfunctioning couplerReservoir overfilledSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then renew or replaceSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then drain fluid to proper level
Application will not fully extend (cylinder or spreader)Fluid level lowFollow symptom 3 procedure for securing load, depressurizing pump, remove application, then ensure proper fluid level
Poor performanceAir trapped in systemEnsure proper fluid levelEnsure vented oil filler plug let pressurized reservoir air escape (see BEFORE USE)

Producent: Shanghaimuxinmuyeyouxiangongsi Adres:

Shuangchenglu 803nong11hao1602A-1609shi, baoshanqu, szanghaj 200000 CN.

Import do AUS: SIHAO PTY LTD, 1 ROKEVA STREETEASTWOOD NSW 2122 Australii

Import do USA: Sanven Technology Ltd., Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730

REPREZENT KE

E-CrossStu GmbH

Mainzer Landstr.69, 60329 Frankfurt nad Menem.

C/O YH Consulting Limited Office 147, Centurion House, London Road, Staines-upon-Thames, Surrey, TW18 4AX

VEVOR®

TOUGH TOOLS, HALF PRICE

www.vevor.com/support

VEVOR®

TOUGH TOOLS, HALF PRICE

Technische ondersteuning en e-garantiecertificaat www.vevor.com/support

natural_image Black and silver electric shock absorber device with metallic casing and side slots (no visible text or symbols)

HULP NODIG? NEEM CONTACT MET ONS OP!

Repair Parts Sheets for hydraulic air hydraulic pumps are available from your nearest authorized EAGLE PRO Service Center or EAGLE PRO Sales office.

Vevor TL-A5122 - HULP NODIG? NEEM CONTACT MET ONS OP! - 1

natural_image Black and silver electric shock absorber device with metallic casing and side slots (no visible text or symbols)

NOTE

PLEASE READ AND FOLLOW THIS INSTRUCTION BEFORE YOU USE EAGLE PRO AIR HYDRAULIC PUMPS.

Carefully inspect all components for shipping damage. If shipping damage is found, notify carrier at once. The carrier is responsible for any damage resulting from shipment.

1. SAFETY

Vevor TL-A5122 - SAFETY - 1

To avoid personal injury or property damage, please follow all safety precautions. EAGLE PRO cannot be responsible for injury or damage resulting from unsafe and incorrect products use or system operation, or lack of maintenance.

DANGER is used when your action or lack of action may cause serious injury or even death. WARNING indicates a potential danger that requires correct action to avoid personal injury. IMPORTANT indicates correct action to prevent damage or equipment failure.

Vevor TL-A5122 - SAFETY - 2

DANGER

The hydraulic equipment operator must be a qualified operator with correct training and work experience with hydraulic equipment. Lack of knowledge in any of these areas can lead to equipment damage or personal injury.
To avoid personal injury, please do not modify or weld hydraulic equipment without approval of EAGLE PRO.
✗ Never lift a more than the rated capacity of the cylinder, overloading causes equipment failure and serious personal injury.

✗ The cylinder is a load lifting device, not a load holding device. After the load has been raised or lowered, it must always be held mechanically, never work under a load supported by a hydraulic unit.

Keep hands and feet away from cylinder and workplace during operation to avoid personal injury.

Do not put unbalanced or off-center loads on cylinders. The incorrect load can result in equipment failure and serious personal injury.

Vevor TL-A5122 - DANGER - 1

WARNING

※ Wear safety glasses, helmet and other necessary personal protective equipment when operating hydraulic equipment.

Cylinder used to lift load must have solid footing for correct support. Please select steel or wood blocks that are capable of supporting the load.

Install Pressure gauges in the system to monitor the operating pressure. The gauge must have the same pressure rating as the pump and cylinder. The wrong gauges may result in personal injury.

The system operating pressure must lower than the lowest rated pressure in the system.

Carefully inspect the cylinder and couplers before use cylinder. Never connect a cylinder with damaged couplers or damaged port threads. The damaged coupler or damaged port threads may cause equipment failure and possible personal injury.

Install coupler in a clean environment; prevent dirt or other debris from entering into cylinder body or tube. Dirt or other debris will damage the cylinder and result in equipment failure and possible personal injury.

Before removing or tightening hose or coupler, release hydraulic pressure in system.

Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin, causing serious injury. Seek medical aid immediately if injured.

Use EAGLE PRO or other approved hydraulic oil

For hydraulic technical help or repair service. Please contact the authorized EAGLE PRO Service Center in your area. EAGLE PRO has no obligations under any warranty with respect to products that have been repaired by unauthorized personnel, modified, or damaged through misuse, abuse, accident, neglect, or mishandling.

IMPORTANT

Keep the air hydraulic pump clean at all time.

When the Air hydraulic pump is not in use, release the valve, remove hose and use rubber cap to recover the port.

Do not drop objects on hose.

Do not lift or carry hydraulic equipment by the hoses or couplers, use the handle or other means.

Use hydraulic equipment in normal operating temperatures. Do not use equipment in temperatures of 65 °C (150°F) or higher. Overheating will soften seals and weakens hose material, resulting in oil leaking or other equipment failure.

2. DESCRIPTION

Air Hydraulic Pump supplies hydraulic fluid pressure to selected tools. It consists of an in-line air and hydraulic cylinder.

SPECIFICATIONS

ModelPressure Rating (psi)Useable Oil Capacity (cu.in)Input Air pressure (psi)Input Port Threads (NPT)Output port Threads (NPT)Oil Delivery (cu.in / min)Operational MannerWeight lbs
No loadload
TL-A512210,00030.590-1451/4 -183/8 -1849.57.6Foot Pedal13.2

3. BEFORE USE

Note: Always secure threaded port connections with non-hardening pipe thread compound. Tighten securely to prevent accidental removal of components while in use. Take care not to introduce thread compound into port openings.

Familiarize yourself with the specifications and illustrations in this operator 担 manual. Know your pump, its limitations and how it operates before attempting to use. Refer to Specification chart on above for details of oil port thread size, usable oil capacity, and other information.

4. OPERATION

Operation of the pump as follow:

Connect the hose of the Air Hydraulic pump to the hydraulic coupling on the selected tool.

Connect the air supply line to the Air Hydraulic pump. Air supply should be 5-10 CFM at 100 PSI to obtain proper operating characteristic. The air line should be equipped with an air line filter.

※ To Advance, hold or Retract

Foot Pedal operates pumps:

a. Depress the Pump end of pedal will pump hydraulic oil to the system.
b. Stop depressing the Pump or Release end will stop and hold the pressure.
c. Depress the Release end of pedal will release the pressure in the system.

Vevor TL-A5122 - OPERATION - 1

text_image PUMP Air input port RELEASE Hydraulic Oil output port

5. MAINTENANCE

5.1 Inspect the connections

Inspect hoses and connections, tighten connections as needed. Use non-hardening pipe thread compound when servicing connections.

5.2 Adding Hydraulic Fluid

✗ Depressurize and disconnect hydraulic hose from application.

✗ Remove the oil filler plug located on the side of the reservoir.
Use a small funnel to fill reservoir.
Wipe up any spilled fluid and reinstall the oil filler plug.

Vevor TL-A5122 - Adding Hydraulic Fluid - 1

natural_image Close-up of a mechanical component with a white flange and bolted end, showing a directional arrow (no text or symbols)

Note: Use only EAGLE PRO or other approved hydraulic oil. Never use brake fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin etc. Use of other than good quality hydraulic oil will void warranty and damage the pump, hose and application.

5.3 Changing Hydraulic Fluid

For best results, change fluid once a year.
✗ Repeat step 5.2 above, and then pour used fluid into a sealable container.
Dispose of fluid in accordance with local regulations.
Fill with good quality hydraulic oil as recommended above. Reinstall vented oil filler plug.

5.4 Lubrication

Use a light machine oil to lubricate pivot points, hinges etc.

5.5 Storage

✗ Depressurize and disconnect hydraulic hoses from application.
✗ Clean the pump and hose and couplers
Store in clean dry environment, avoid temperature extremes.

6. TROUBLE SHOOTING

Vevor TL-A5122 - TROUBLE SHOOTING - 1

IMPORTANT: EAGLE PRO air hydraulic pumps should be repaired only by a qualified operator or Authorized EAGLE PRO Service Centers. Repairing air hydraulic pumps without special tools and knowledge may result in personal injury.

Always release pressure and disconnect hose(s) before making repairs.

SymptomPossible CausesCorrective Action
Application will not extend, move or respond to pressurized fluidOverload conditionRelease valve not closedRemedy overload conditionEnsure release valve closed
Application responds to pressurized fluid, but system does not maintain pressureOverload conditionRelease valve not closedHydraulic unit malfunctionRemedy overload conditionEnsure release valve closed
Application will not return fluid to pump (i.e. cylinder will not retract)Malfunctioning couplerReservoir overfilledSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then renew or replaceSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then drain fluid to proper level
Application will not fully extend (cylinder or spreader)Fluid level lowFollow symptom 3 procedure for securing load, depressurizing pump, remove application, then ensure proper fluid level
Poor performanceAir trapped in systemEnsure proper fluid levelEnsure vented oil filler plug let pressurized reservoir air escape (see BEFORE USE)

Fabrikant: Shanghaimuxinmuyeyouxiangongsi Adres:

Shuangchenglu 803nong11hao1602A-1609shi, baoshanqu, shanghai 200000 CN.

C/O YH Consulting Limited Kantoor 147, Centurion House, London Road, Staines-upon-Thames, Surrey, TW18 4AX

VEVOR®

TOUGH TOOLS, HALF PRICE

Technische ondersteuning en e- garantiecertificaat www.vevor.com/support

VEVOR®

TOUGH TOOLS, HALF PRICE

www.vevor.com/support

LUFTHYDRAULIKPUMP

ANVÄNDARMANUAL

MODELL: TL-A5122

natural_image Black and silver electric shock absorber device with metallic casing and side slots (no visible text or symbols)

Repair Parts Sheets for hydraulic air hydraulic pumps are available from your nearest authorized EAGLE PRO Service Center or EAGLE PRO Sales office.

Vevor TL-A5122 - ANVÄNDARMANUAL - 1

natural_image Black and silver electric shock absorber device with metallic casing and side slots (no visible text or symbols)

NOTE

PLEASE READ AND FOLLOW THIS INSTRUCTION BEFORE YOU USE EAGLE PRO AIR HYDRAULIC PUMPS.

Carefully inspect all components for shipping damage. If shipping damage is found, notify carrier at once. The carrier is responsible for any damage resulting from shipment.

1. SAFETY

Vevor TL-A5122 - SAFETY - 1

To avoid personal injury or property damage, please follow all safety precautions. EAGLE PRO cannot be responsible for injury or damage resulting from unsafe and incorrect products use or system operation, or lack of maintenance.

DANGER is used when your action or lack of action may cause serious injury or even death. WARNING indicates a potential danger that requires correct action to avoid personal injury. IMPORTANT indicates correct action to prevent damage or equipment failure.

Vevor TL-A5122 - SAFETY - 2

DANGER

The hydraulic equipment operator must be a qualified operator with correct training and work experience with hydraulic equipment. Lack of knowledge in any of these areas can lead to equipment damage or personal injury.
To avoid personal injury, please do not modify or weld hydraulic equipment without approval of EAGLE PRO.
✗ Never lift a more than the rated capacity of the cylinder, overloading causes equipment failure and serious personal injury.

✗ The cylinder is a load lifting device, not a load holding device. After the load has been raised or lowered, it must always be held mechanically, never work under a load supported by a hydraulic unit.

Keep hands and feet away from cylinder and workplace during operation to avoid personal injury.

Do not put unbalanced or off-center loads on cylinders. The incorrect load can result in equipment failure and serious personal injury.

Vevor TL-A5122 - DANGER - 1

WARNING

※ Wear safety glasses, helmet and other necessary personal protective equipment when operating hydraulic equipment.

Cylinder used to lift load must have solid footing for correct support. Please select steel or wood blocks that are capable of supporting the load.

Install Pressure gauges in the system to monitor the operating pressure. The gauge must have the same pressure rating as the pump and cylinder. The wrong gauges may result in personal injury.

The system operating pressure must lower than the lowest rated pressure in the system.

Carefully inspect the cylinder and couplers before use cylinder. Never connect a cylinder with damaged couplers or damaged port threads. The damaged coupler or damaged port threads may cause equipment failure and possible personal injury.

Install coupler in a clean environment; prevent dirt or other debris from entering into cylinder body or tube. Dirt or other debris will damage the cylinder and result in equipment failure and possible personal injury.

Before removing or tightening hose or coupler, release hydraulic pressure in system.

Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin, causing serious injury. Seek medical aid immediately if injured.

Use EAGLE PRO or other approved hydraulic oil

For hydraulic technical help or repair service. Please contact the authorized EAGLE PRO Service Center in your area. EAGLE PRO has no obligations under any warranty with respect to products that have been repaired by unauthorized personnel, modified, or damaged through misuse, abuse, accident, neglect, or mishandling.

IMPORTANT

Keep the air hydraulic pump clean at all time.

When the Air hydraulic pump is not in use, release the valve, remove hose and use rubber cap to recover the port.

Do not drop objects on hose.

Do not lift or carry hydraulic equipment by the hoses or couplers, use the handle or other means.

Use hydraulic equipment in normal operating temperatures. Do not use equipment in temperatures of 65 °C (150°F) or higher. Overheating will soften seals and weakens hose material, resulting in oil leaking or other equipment failure.

2. DESCRIPTION

Air Hydraulic Pump supplies hydraulic fluid pressure to selected tools. It consists of an in-line air and hydraulic cylinder.

SPECIFICATIONS

ModelPressure Rating (psi)Useable Oil Capacity (cu.in)Input Air pressure (psi)Input Port Threads (NPT)Output port Threads (NPT)Oil Delivery (cu.in / min)Operational MannerWeight lbs
No loadload
TL-A512210,00030.590-1451/4 -183/8 -1849.57.6Foot Pedal13.2

3. BEFORE USE

Note: Always secure threaded port connections with non-hardening pipe thread compound. Tighten securely to prevent accidental removal of components while in use. Take care not to introduce thread compound into port openings.

Familiarize yourself with the specifications and illustrations in this operator 担 manual. Know your pump, its limitations and how it operates before attempting to use. Refer to Specification chart on above for details of oil port thread size, usable oil capacity, and other information.

4. OPERATION

Operation of the pump as follow:

Connect the hose of the Air Hydraulic pump to the hydraulic coupling on the selected tool.

Connect the air supply line to the Air Hydraulic pump. Air supply should be 5-10 CFM at 100 PSI to obtain proper operating characteristic. The air line should be equipped with an air line filter.

※ To Advance, hold or Retract

Foot Pedal operates pumps:

a. Depress the Pump end of pedal will pump hydraulic oil to the system.
b. Stop depressing the Pump or Release end will stop and hold the pressure.
c. Depress the Release end of pedal will release the pressure in the system.

Vevor TL-A5122 - OPERATION - 1

text_image PUMP Air input port RELEASE Hydraulic Oil output port

5. MAINTENANCE

5.1 Inspect the connections

Inspect hoses and connections, tighten connections as needed. Use non-hardening pipe thread compound when servicing connections.

5.2 Adding Hydraulic Fluid

✗ Depressurize and disconnect hydraulic hose from application.

✗ Remove the oil filler plug located on the side of the reservoir.
Use a small funnel to fill reservoir.
Wipe up any spilled fluid and reinstall the oil filler plug.

Vevor TL-A5122 - Adding Hydraulic Fluid - 1

natural_image Close-up of a mechanical component with a white flange and bolted end, showing a directional arrow (no text or symbols)

Note: Use only EAGLE PRO or other approved hydraulic oil. Never use brake fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin etc. Use of other than good quality hydraulic oil will void warranty and damage the pump, hose and application.

5.3 Changing Hydraulic Fluid

For best results, change fluid once a year.
✗ Repeat step 5.2 above, and then pour used fluid into a sealable container.
Dispose of fluid in accordance with local regulations.
Fill with good quality hydraulic oil as recommended above. Reinstall vented oil filler plug.

5.4 Lubrication

Use a light machine oil to lubricate pivot points, hinges etc.

5.5 Storage

✗ Depressurize and disconnect hydraulic hoses from application.
✗ Clean the pump and hose and couplers
Store in clean dry environment, avoid temperature extremes.

6. TROUBLE SHOOTING

Vevor TL-A5122 - TROUBLE SHOOTING - 1

IMPORTANT: EAGLE PRO air hydraulic pumps should be repaired only by a qualified operator or Authorized EAGLE PRO Service Centers. Repairing air hydraulic pumps without special tools and knowledge may result in personal injury.

Always release pressure and disconnect hose(s) before making repairs.

SymptomPossible CausesCorrective Action
Application will not extend, move or respond to pressurized fluidOverload conditionRelease valve not closedRemedy overload conditionEnsure release valve closed
Application responds to pressurized fluid, but system does not maintain pressureOverload conditionRelease valve not closedHydraulic unit malfunctionRemedy overload conditionEnsure release valve closed
Application will not return fluid to pump (i.e. cylinder will not retract)Malfunctioning couplerReservoir overfilledSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then renew or replaceSecure load by other means.Open release valve, depressurize pump and hose, remove coupler and/or application, then drain fluid to proper level
Application will not fully extend (cylinder or spreader)Fluid level lowFollow symptom 3 procedure for securing load, depressurizing pump, remove application, then ensure proper fluid level
Poor performanceAir trapped in systemEnsure proper fluid levelEnsure vented oil filler plug let pressurized reservoir air escape (see BEFORE USE)

Tillverkare: Shanghaimuxinmuyeyouxiangongsi

Adress: Shuangchenglu 803nong11hao1602A-1609shi, baoshanqu, shanghai 200000 CN.

Importerad till AUS: SIHAO PTY LTD, 1 ROKEVA STREETEASTWOOD NSW 2122 Australien

Importerad till USA: Sanven Technology Ltd., Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730

ECREP

E-CrossStu GmbH

Mainzer Landstr.69, 60329 Frankfurt am Main.

UKREP

YH CONSULTING LIMITED.

C/O YH Consulting Limited Office 147, Centurion House,

London Road, Staines-upon-Thames, Surrey, TW18 4AX

VEVOR®

TOUGH TOOLS, HALF PRICE

www.vevor.com/support

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Vevor

Model : TL-A5122

Category : Pump