PANASONIC S-90MF3E5AN - Air Conditioning

S-90MF3E5AN - Air Conditioning PANASONIC - Free user manual and instructions

Find the device manual for free S-90MF3E5AN PANASONIC in PDF.

📄 60 pages English EN Download 💬 AI Question
Notice PANASONIC S-90MF3E5AN - page 3
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about S-90MF3E5AN PANASONIC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air Conditioning in PDF format for free! Find your manual S-90MF3E5AN - PANASONIC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. S-90MF3E5AN by PANASONIC.

USER MANUAL S-90MF3E5AN PANASONIC

* Shows the standard installation

PANASONIC S-90MF3E5AN - 1

Middle Static Pressure

Duct (Type F3)

Model No.

S-15MF3E5ANS-73MF3E5AN
S-22MF3E5ANS-90MF3E5AN
S-28MF3E5ANS-106MF3E5AN
S-36MF3E5ANS-112MF3E5AN
S-45MF3E5ANS-140MF3E5AN
S-56MF3E5ANS-160MF3E5AN
S-60MF3E5AN

Panasonic®

Operating Instructions

(Simplified Version)

Air Conditioner

SCAN 2D-BARCODE FOR FULL OPERATING INSTRUCTIONS

https://eu.datanavi.ac.smartcloud.panasonic.com/documents/

PANASONIC S-90MF3E5AN - SCAN 2D-BARCODE FOR FULL OPERATING INSTRUCTIONS - 1

ENGLISH

3\~6

Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

This booklet mainly mentions the safety-related regulatory matters. Regarding the contents of the operation, please scan the matrix two-dimensional (2D) barcode and refer to the detailed manuals.

FRANÇAIS

7 \~ 10

Thank you for purchasing this Panasonic product. This product is a commercial air conditioner indoor unit. Installation Instructions attached.

Safety Precautions

The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:

PANASONIC S-90MF3E5AN - Safety Precautions - 1

WARNING

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

PANASONIC S-90MF3E5AN - WARNING - 1

CAUTION

This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.

PANASONIC S-90MF3E5AN - CAUTION - 1

Prohibited matters

PANASONIC S-90MF3E5AN - CAUTION - 2

Matters to be observed

  • Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.
  • This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.

Important Information Regarding The Refrigerant Used

This product contains fluorinated greenhouse gases.

Do not vent gases into the atmosphere.

Refrigerant type: R410A

GWP ^(1) value: 2088

(1)GWP = global warming potential

Periodical inspections for refrigerant leaks may be required depending on European or local legislation.

Please contact your local dealer for more information.

PANASONIC S-90MF3E5AN - Important Information Regarding The Refrigerant Used - 1

WARNING

PANASONIC S-90MF3E5AN - WARNING - 1

Confirm to authorized dealer or specialist on usage of specified refrigerant type. Using of refrigerant other than the specified type may cause product damage, burst and injury, etc.

This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.

PANASONIC S-90MF3E5AN - WARNING - 2

Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous.

Do not use this appliance in a potentially explosive atmosphere.

Never touch the unit with wet hands.

Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit, rotating parts m cause injury.

PANASONIC S-90MF3E5AN - WARNING - 3

Disposal of Old Equipment

Only for European Union and countries with recycling systems

PANASONIC S-90MF3E5AN - Only for European Union and countries with recycling systems - 1

This symbol on the products, packaging, and/or accompanying documents means that used electrical and electronic products must not be mixed with general household waste.

For proper treatment, recovery and recycling of old products, please take them to applicable collection points in accordance with your national legislation.

By disposing of them correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment. For more information about collection and recycling, please contact your local municipality.

Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.

WARNING

PANASONIC S-90MF3E5AN - WARNING - 1

If the refrigerant comes in contact with a flame, it produces toxic gases.

For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing.

Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting me isolate the air conditioner from main power supply in case of emergency.

PANASONIC S-90MF3E5AN - WARNING - 2

Dispose of according to national and/or local legislation.

PANASONIC S-90MF3E5AN - WARNING - 3

This product must not be modified or disassembled under any circumstances.

Modified or disassembled unit may cause fire, electric shock or injury.

Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning.

In case of malfunction of this appliance, do not repair by yourself. Contact the sales dealer or service dealer for a repair and disposal.

PANASONIC S-90MF3E5AN - WARNING - 4

Provide a power outlet to be used exclusively for each unit, and a power supply disconnect, Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) for overcurrent protection should be provided in the exclusive line.

Provide a power outlet exclusively for each unit, and full disconnection means having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the wiring rules.

To prevent possible hazards from insulation failure, the unit must be grounded.

PANASONIC S-90MF3E5AN - WARNING - 5

PANASONIC S-90MF3E5AN - WARNING - 6

Do not use modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire.

PANASONIC S-90MF3E5AN - WARNING - 7

PANASONIC S-90MF3E5AN - WARNING - 8

PANASONIC S-90MF3E5AN - WARNING - 9

Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fire/electric shock) Examples of abnormality/failure:

• The ELCB trips frequently.
- The product sometimes does not start when turned on.
- The power is sometimes disconnected when the cord is moved.
- Burnt odor or abnormal noise is detected during operation.
• The body is deformed or abnormally hot.
• Water leaks from the indoor unit.
- Power cord or plug becomes abnormally hot.
- Fan speed cannot be controlled.
- The unit stops running immediately even if it is switched on for operation.
Contact immediately your local dealer for maintenance/repair.

PANASONIC S-90MF3E5AN - WARNING - 10

Do not sit or step on the unit. You may fall down accidentally.

PANASONIC S-90MF3E5AN - WARNING - 11

CAUTION

PANASONIC S-90MF3E5AN - CAUTION - 1

This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Keep the fire alarm and the air outlet at least 1.5 m away from the unit.

Do not make the room too hot or too cold if babies or invalids are present.

PANASONIC S-90MF3E5AN - CAUTION - 2

Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button.

Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.

PANASONIC S-90MF3E5AN - CAUTION - 3

Do not touch the air inlet or the sharp aluminum fins of the outdoor unit. You may get injured.

PANASONIC S-90MF3E5AN - CAUTION - 4

Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged.

PANASONIC S-90MF3E5AN - CAUTION - 5

NOTICE

  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes.
  • The English text is the original instructions. Other languages are translation of the original instructions.

Maintenance

PANASONIC S-90MF3E5AN - Maintenance - 1

WARNING

  • For safety, be sure to turn the air conditioner off and disconnect the power before cleaning. (Otherwise, electric shock or injury may result because the fan is rotating at high speed.)
  • Do not pour water on the indoor unit. (This may damage the internal components and cause an electric shock hazard.)

PANASONIC S-90MF3E5AN - WARNING - 1

CAUTION

● Never use solvents or harsh chemicals. Also, do not wipe plastic parts using very hot water. (This may cause deformation or change in colour.)
● Some metal edges and fins are sharp. Be careful when you clean those parts. (Injury may result.)
- Use a firm stool or ladder when cleaning an indoor unit installed in high locations.

Outdoor unit

The internal coil and other components of the outdoor unit must be cleaned periodically.

- Consult your dealer or service center.

Operation Mechanism

■ Heating performance

● This air conditioner utilizes outside air for heating; its heating performance reduces as outside temperature decreases.
→ In the event that heating is not sufficient, please use an additional heating appliance.

■ Defrosting

● This appliance may start defrosting operation to melt frost formed in the outdoor unit.
① Defrosting starts: The indoor unit fan stops (or the speed becomes extremely slow).
"STANDBY) appears.
② Heating operation resumes after several minutes: The indoor unit fan remains stopped (or it will run at a very slow speed) until the indoor heat exchanger coil warms up sufficiently.
→ "STANDBY" appears.
③Defrosting is complete: The indoor unit fan starts operation.
→ "STANDBY" disappears.

■ "DRY" operation

  • Once the room temperature reaches the level that was set, the outdoor unit repeats the cycle of turning on and off automatically.
  • When the room temperature is more likely to reach the level that was set, the fan speed is set to "breeze" (light wind) automatically.

■ Should power failure occur while the unit is running

The unit will resume operation automatically. Operation settings prior to power failure will be used.

NOTICE

This air conditioner incorporates a biocidal product.

PANASONIC S-90MF3E5AN - This air conditioner incorporates a biocidal product. - 1

Free radicals generated by a device incorporated in the air conditioner have the capacity to inhibit pollutants, such as certain types of bacteria, viruses, mould.

Active substances : Free radicals generated in situ from ambient air or water.

Usage : This device function can be turned ON / OFF by the "nanoe X" icon button or remote controller settings if there is no "nanoe X" icon button. Please refer to "How to Use" for more details.

Scan the matrix two-dimensional (2D) barcode on the front page and read the detailed instructions on use.

^(1) GWP = global warming potential (broeikaseffect)

* In the case of nanoe™ X "OFF"

Specifications

Model Name S-106MF3E5AN S-112MF3E5AAN S-140MF3E5ANS-160MF3E5AN
Power source 220 - 230-240 V~50 - 60 Hz
Cooling capacitykW10.6 11.2 14.0 16.0
BTU/h36,200 38,200 47,800 54,600
kW8.2 8.5 9.9 11.0
Latent kW2.4 2.7 4.1 5.0
Heating capacitykW11.4 12.5 16.0 18.0
BTU/h38,900 42,700 54,600 61,400
Cooling electric power input*kW0.146 0.265 0.265 0.330
Heating electric power input*kW0.146 0.265 0.265 0.330
Sound pressure levelHigh dB(A)36 41 41 43
Medium dB(A)32 36 36 37
Low dB(A)27 32 32 33
Sound power levelHigh dB(A)59 64 64 66
Medium dB(A)55 59 59 60
Low dB(A)50 55 55 56

* In the case of nanoe™ X "OFF"

Specifications

Corresponding language table

English Français EspañolDeutsch
Middle Static Pressure Duct (Type F3)Conduite de pression statique moyenne (Type F3)Conducto de presión estática media (tipo F3)Kanal mit mittlerem statischem Druck (Typ F3)
Shows the standard installationIndique l'installation standard Muestra la instalación estándar Zeigt die Standardinstallation
Model Name Nom du modèle Nombre del modelo Modellbezeichnung
Power Source Source d'alimentation Alimentación Stromversorgung
Cooling Capacity Capacité de refroidissement Capacidad de refrigeración Kühlkapazität
Sensible Sensible Sensible Sensibel
LatentLatentLatenteLatent
Heating CapacityCapacité de chauffageCapacidad de calefacciónHeizkapazität
Cooling electric power inputPuissance électrique absorbée de refroidissementEntrada de alimentación eléctrica de refrigeraciónElektrische Leistungsaufnahme Kühlen
Heating electric power inputPuissance électrique absorbée de chauffageEntrada de alimentación eléctrica de calefacciónElektrische Leistungsaufnahme Heizen
Sound pressure level (High/Medium/Low)Niveau de pression sonore (Élevé/Moyen/Bas)Nivel de presión sonora (Alto/Medio/Bajo)Schalldruckpegel (Hoch/Mittel/Niedrig)
Sound power level (High/Medium/Low)Niveau de puissance sonore (Élevé/Moyen/Bas)Nivel de potencia acústica (Alto/Medio/Bajo)Schallleistungspegel (Hoch/Mittel/Niedrig)
In the case of nanoeTM X “OFF”Dans le cas où nanoeTM X est sur « ARRÊT »En el caso de nanoeTM X en “APAGAR”Bei nanoeTM X „AUS“
English ItalianoNederlandsPortuguês
Middle Static Pressure Duct (Type F3)Condotto a pressione statica media (Tipo F3)Gemiddelde statische druk kanaal (Type F3)Conduta de Pressão Estática Média (Tipo F3)
Shows the standard installationÈ illustrata l'installazione standardToont de standaard installatieMostra a instalação padrão
Model Name Nome del modelloModelnaamNome do modelo
Power Source Alimentazione Stroomvoorziening Fonte de energia
Cooling CapacityCapacità di raffreddamentoKoelcapaciteitCapacidade de arrefecimento
Sensible SensibileVerstandigSensível
LatentLatenteLatentLatente
Heating CapacityCapacità di riscaldamentoVerwarmingscapaciteitCapacidade de aquecimento
Cooling electric power inputAssorbimento elettrico raffreddamentoElektrisch ingangsvermogen bij koelenEntrada de energia eléctrica de arrefecimento
Heating electric power inputAssorbimento elettrico riscaldamentoElektrisch ingangsvermogen bij verwarmenEntrada de energia eléctrica de aquecimento
Sound pressure level (High/Medium/Low)Livello di pressione acustica (Alto/Medio/Basso)Geluidsdrukniveau (Hoog/Gemiddeld/Laag)Nível de pressão sonora (Alto/Médio/Baixo)
Sound power level (High/Medium/Low)Livello di potenza acustica (Alto/Medio/Basso)Geluidsvermogenniveau (Hoog/Gemiddeld/Laag)Nível de potência sonora (Alto/Médio/Baixo)
In the case of nanoeTM X “OFF”Nel caso nanoeTM X sia “SPENTO”In het geval nanoeTM X “UIT” staatNo caso do nanoeTM X em “DESLIGADO”

Specifications

Corresponding language table

English Ελληνικη Βългарски Türkçe
Middle Static Pressure Duct(Type F3)Μεσαίος αγωγός στατικής πίεσης (Τύπος F3)Τρъбопровод за средно статично налягане (Тип F3)Orta Statik Basınçlı Kanal(Tip F3)
Shows the standard installationΑπεικονίζει την τυπική εγκατάστασηПоказва стандартна инсталацияStandart montaj gösterilmiştir
Model Name Όνομα μοντέλου Наименование на модела ModeAdı
Power Source Πηγή τροφοδοσίας Източник наелектрозахранванеGüç kaynağı
Cooling Capacity Ικανότητα ψύξης Οχлаждаща мощност Soğutma kapasitesi
Sensible Αισθητή ЗначителноDuyulur
LatentΛανθάνουσαЛатентноGizli
Heating CapacityΙκανότητα θέρμανσηςОтоплителна мощностIsıtma kapasitesi
Cooling electric power inputΕίσοδος ηλεκτρικής ισχύος για ψύξηОхлаждане входяща електроенергияSoğutma modunda çekilen elektrik gücü
Heating electric power inputΕίσοδος ηλεκτρικής ισχύος για θέρμανσηОтопление входяща електроенергияIsıtma modunda çekilen elektrik gücü
Sound pressure level(High/Medium/Low)Επίπεδο πίεσης ήχου(Υψηλά/Μεσαία/Χαμηλά)Ниво на звуково налягане(Високо/Средно/Ниско)Ses basıncı düzeyi(Yüksek/Orta/Düşük)
Sound power level(High/Medium/Low)Επίπεδο ισχύος ήχου(Υψηλά/Μεσαία/Χαμηλά)Ниво на сила на звука(Високо/Средно/Ниско)Ses gücü düzeyi(Yüksek/Orta/Düşük)
In the case of nanoeTM X “OFF”Στην περίπτωση nanoeTM X«ΑΠΕΝΕΡΓΟΠΟΙΗΜΕΝΟ»При nanoeTM X „ИЗКЛ“nanoeTM X “KAPALI” olması durumunda

Information on hazardous constituents as specified in sub-rule1 of rule16 (1) in electrical and electronic equipment. Declaration of Conformity with the requirements of the E-Waste (Management) Amendment Rules 2018 with the rule 16 (1) limits with respect to Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls, Polybrominated diphenyl ethers. The content of hazardous substance with the exemption of the applications listed in SCHEDULE II of the E-Waste (Management) Amendment Rules 2018 :

  1. Lead (Pb) – not over 0.1% by weight;
  2. Cadmium (Cd) – not over 0.01% by weight;
  3. Mercury (Hg) – not over 0.1% by weight;
  4. Hexavalent chromium ( Cr^6+ ) – not over 0.1% by weight;
  5. Polybrominated biphenyls (PBBs) – not over 0.1% by weight;
  6. Polybrominated diphenyl ethers (PBDEs) – not over 0.1% by weight.

PANASONIC S-90MF3E5AN - Specifications - 1

For the purpose of recycling to facilitate effective utilization of resources, please return this product to a nearby authorized collection center, registered dismantler of recycler, or Panasonic service center when disposing of this product.

Customer care number (Toll free) : 1800 103 1333 ,1800 108 1333

Please see the Panasonic website for further information on collection centers, etc. or call the customer care toll-free number http://www.panasonic.com/in/corporate/sustainability/panasonic-india-i-recycle-program.html

Do's & Don'ts: E-waste (Management) Amendment Rules 2018
S.No. Do's Don'ts
1.All electrical and electronic products are required to be handed over only to the Authorized recycler.The product should not be opened by the user himself / herself, but only by authorized service personnel.
2.The product should be handed over only to authorized recycler for disposal.The product is not meant for re-sale to any unauthorized agencies / scrap dealers / kabariwalas.
3.Keep the product in an isolated area, after it becomes non-functional / unrepairable so as to prevent its accidental breakage.The product is not meant for mixing into household waste stream.
4.Refer to Operating Instructions for handling of end of life products.Do not keep any replaced spare part(s) from the product in an exposed area.
5.Always dispose products that have reached end of life at Panasonic India Authorized Service Centre.Do not donate old electronic items to anybody.Do not dispose your product in garbage bins along with municipal waste that ultimately reaches landfill.
6.Wherever possible or as instructed, separate the packaging material according to responsible waste disposal options and sorting for recycling.Do not give e-waste to informal and unorganized sectors like Local Scrap Dealers / Rag Pickers.

(English) • Product Information

If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate.

(English) Model No. / Serial No. / Date of purchase / Dealer's address / Phone number

a branch of Panasonic Marketing Europe GmbH,

Maxis 2, Western Road, Bracknell, Berkshire, RG12 1RT

Authorised representative in EU

Panasonic Testing Centre

Panasonic Marketing Europe GmbH

Winsbergring 15, 22525 Hamburg, Germany

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PANASONIC

Model : S-90MF3E5AN

Category : Air Conditioning