Vonroc GP804AA - Pressure switch

GP804AA - Pressure switch Vonroc - Free user manual and instructions

Find the device manual for free GP804AA Vonroc in PDF.

📄 52 pages English EN Download 💬 AI Question
Notice Vonroc GP804AA - page 3
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about GP804AA Vonroc

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Pressure switch in PDF format for free! Find your manual GP804AA - Vonroc and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GP804AA by Vonroc.

USER MANUAL GP804AA Vonroc

natural_image Close-up of a mechanical device with a threaded component and control panel (no visible text or symbols)

1. SAFETY INSTRUCTIONS

Read the enclosed safety warnings, the additional safety warnings and the instructions. Failure to follow the safety warnings and the instructions may result in electric shock, fire and/or serious injury. Save the safety warnings and the instructions for future reference.

The following symbols are used in the user manual or on the product:

Vonroc GP804AA - SAFETY INSTRUCTIONS - 1

Read the user manual.

Vonroc GP804AA - SAFETY INSTRUCTIONS - 2

Denotes risk of personal injury, loss of life or damage to the appliance in case of nonobservance of the instructions in this manual.

Vonroc GP804AA - SAFETY INSTRUCTIONS - 3

Indicates electrical shock hazard.

Vonroc GP804AA - SAFETY INSTRUCTIONS - 4

Protect the appliance against frost.

Vonroc GP804AA - SAFETY INSTRUCTIONS - 5

Do not dispose of the product in unsuitable containers.

Vonroc GP804AA - SAFETY INSTRUCTIONS - 6

The product is in accordance with the applicable safety standards in the European directives.

SAFETY NOTES

THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER MAIN- TENANCE SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD. THE PLUG MUST BE REMOVED FROM THE SOCKETOUTLET BEFORE CLEANING OR MAINTAINING THE APPLIANCE.

Please read these instructions carefully and thoroughly before using this appliance and keep them for future reference. It is very important that you understand how to use this appliance safely so please take the time to familiarise yourself with the requirements as outlined in these instructions.

  • If you are in any doubt what so ever about using this appliance, we strongly recommend that you employ the services of a suitably qualified person.
  • Electrical connection must be protected by a residual current device (RCD) at the power socket with a nominal trip current of 30mA (max).
  • Keep children and pets well away from the work area and never allow children to use this appliance or touch the extension cord at any time. When not in use, keep this appliance stored in a safe place out of reach of children.
  • Never leave the appliance unattended when in use.
  • Do not allow the power cord to lay on or across sharp objects that might pierce the outer insulation. Carry out a visual inspection of the power cord before use and if it is damaged, have it replaced by a specialist service centre. Do not use the appliance if the cord is damaged.
  • Keep the power cord away from heat, frost, oil, solvents or any sharp objects or edges.
  • Electrical connections e.g. extension cable, must be protected from moisture at all times.
  • Check that the power rating on your appliance corresponds with the power rating at you mains supply. The supply voltage must be 220-240VAC.
  • Only switch the power on or off with dry hands.
  • Never use this appliance in a pond or swimming pool while people are present in the water!
  • Do not use the switch for drinking water.
  • Corrosive, flammable or explosive substances, grease, oil, salt water and sewage must not be conveyed by the appliance.
  • The pH of water must between 6.5 and 8.5.
  • The temperature of the liquid conveyed may not exceed 35 °C.

Electrical safety

When using electric appliances always observe the safety regulations applicable in your country to reduce the risk of fire, electric shock and personal injury. Read the following safety instructions and also the enclosed safety instructions.

Vonroc GP804AA - Electrical safety - 1

Always check that the power supply corresponds to the voltage on the rating plate.

Connecting to the power supply

Check that the power supply and plug used in accordance with your appliance. Have a look at the rating plate on the appliance. Any changes should always be carried out by a qualified electrician.

Vonroc GP804AA - Connecting to the power supply - 1

Warning! This appliance must be earthed. If not properly earthed this appliance can cause an electrical shock. Be sure that the power supply outlet is earthed. If there is any doubt, have it checked by a qualified electrician.

Vonroc GP804AA - Connecting to the power supply - 2

Warning! Avoid contact with the terminals on the plug when installing (removing) the plug to (from) the power supply outlet. Contact will cause a severe electrical shock.

Replacing cables or plugs

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Immediately throw away old cables or plugs when they have been replaced by new ones. It is dangerous to insert the plug of a loose cable in the wall outlet.

Using extension cables

Only use an approved extension cable suitable for the power input of the appliance. The minimum conductor size is 1.5 mm ^2 . When using a cable reel always unwind the reel completely.

2. INFORMATION

With the pressure switch you can automatically control the operation of a garden pump. The switch is intended for private use for household water supply and irrigation of gardens, it is not intended for commercial use.

It is solely intended for clear and rain water.

TECHNICAL SPECIFICATIONS

Model No. GP804AA
Voltage 220-240V~ 50/60Hz
Max. pressure 10 bar
Max. power 1100W
Max. current 10A
Max. particle size 1 mm (clean water)
Switch-on pressure 1.5-2.5 bar
Default switch-on pressure 1.5 bar
Dry run protection Yes
Pressure gauge Yes
Backflow preventer Yes
Max. water temperature 35 °C
ProtectionIP44
Pressure connectionG1" external thread
Pump connectionG1" external thread
Cable length 1.2m
Weight1.3 kg

DESCRIPTION

The numbers in the text refer to the diagrams on page 2.

  1. Water outlet
  2. Pressure gauge
  3. Water inlet
  4. Power socket
  5. Reset button
  6. LED-power
  7. LED-failure
  8. LED-on
  9. Pressure setting screw

3. ASSEMBLY

Vonroc GP804AA - ASSEMBLY - 1

Before carrying out any work on the pressure switch, disconnect the mains plug from the power supply.

Vonroc GP804AA - ASSEMBLY - 2

Do not mount the pressure switch into the water inlet side of the pump.

Vonroc GP804AA - ASSEMBLY - 3

The pressure switch must be in an upright position. If it is in any other position, the pressure switch cannot work correctly.

Vonroc GP804AA - ASSEMBLY - 4

The pressure switch should be installed in ventilated and dry environment. It could be installed outside, provided having proper covering to prevent rain and wind.

Install the pressure switch (Fig. A, B)

  1. Apply thread seal tape (Teflon tape) to the water inlet (3) connection.
  2. Screw the water inlet (3) connection into the pump outlet, as shown on figure B.
  3. Decide which hose diameter and hose connection system fittings you are going to use.
  4. Apply thread seal tape (Teflon tape) to the water outlet (1) connection.
  5. Screw the coupling (not included) on the water outlet (1).
  6. Connect the mains plug of the pump to the power socket (4).
  7. Connect the hose (not included) to the coupling.
  8. Check that the hose has no kinks in it.

4. OPERATION

Vonroc GP804AA - OPERATION - 1

Never use the pressure switch while people are present in the water!

Vonroc GP804AA - OPERATION - 2

Only switch the power on or off with dry hands.

Switching on/off (Fig. A)

  1. Check that the ON/OFF switch of the pump is in the 'O' position before connecting the pressure switch to the power supply.
  2. Move the ON/OFF switch of the pump into the position 'I' to switch the pump on.
  3. With the pressure switch you can automatically control the operation of a garden pump. Open the connected tap or spray gun to start the pump. When you start the pump, there will be a lot of air in the water first. This is not a defect of your pump, but serves to remove air from the pump. It may take several minutes for the air to escape when the pump is used for the first time.
  4. When you close the connected tap or the spray gun, the pump automatically stops pumping.
  5. Move the ON/OFF switch of the pump into the position 'O' to switch the pump off.

The pressure switch has 3 LED indicators (6, 7, 8) which indicate the status of the pressure switch:

LED indicators Operating status
LED-power (6)The pressure switch is connected to the power supply. The pressure switch is ready for use.
LED-failure (7)The pump is running dry without water. The dry-run safety is activated. Use the pump's operating manual to find the cause of the failure and correct it. Then restart the pump by pressing the reset button (5) on the pressure switch.
LED-on (8)The pressure switch has tripped, the socket is live. The pump is operating.

Reading the pressure (Fig. A)

The pipe pressure can be read on the pressure gauge (2). The black scale indicates the pressure in bar.

Setting the switch-on pressure (Fig. A)

The default switch-on pressure is 1.5 bar. The switch-on pressure can be adjusted to a value between 1.5 bar to 2.5 bar.

It is possible to set the switch-on pressure by using the pressure setting screw (9). Every 360^ turn decreases or increases the switch-on pressure for approx. 0.2bar.

  • By turning clockwise, the pressure will be increased.
  • By turning anti-clockwise, the pressure will be decreased.

Finish operation (Fig. A)

Vonroc GP804AA - Finish operation (Fig. A) - 1

When there is the risk of frost or if you do not use your pressure switch for a long time, please properly store your pressure switch.

  1. Check that the ON/OFF switch of the pump is in the 'O' position.
  2. Remove the mains plug from the mains.
  3. Disconnect the mains plug of the pump from the power socket (4).
  4. Unscrew and remove the pressure switch. Let the water drain, then rinse with clear water. Make sure that there is no water left.
  5. Remove the water hose from the water outlet (1). Unscrew the coupling from the water outlet (1).
  6. Clean and store the device (see 'Maintenance').

5. MAINTENANCE

Vonroc GP804AA - MAINTENANCE - 1

Before cleaning and maintenance, always switch off the appliance and remove the mains plug from the mains.

Cleaning

Vonroc GP804AA - Cleaning - 1

NOTICE! Risk of product damage! Never submerge device in water while cleaning.

Do not use cleaning agents or solvents. Wipe the device using a dry cloth.

Storage and frost potection

The pressure switch and accessories that are not completely drained can be destroyed by frost. Completely drain the pressure switch and accessories and protect them against frost.

Keep this appliance in well-ventilated dry premises with temperature not going below +5°C.

When not in use, keep this appliance stored in a safe place out of reach of children.

TROUBLE SHOOTING GUIDE

Problem Cause Remedy
Pump does not startNo mains supplyCheck mains supply
Pump not switched onSwitch on pump
LED-failure is onPress the reset button
Not enough pump pressureCheck that the pump pressure is 0.8bar higher than the starting pressure of the switch
The switch-on pressure is set too lowBy turning the pressure setting screw clockwise, the switch-on pressure will be increased
The dry-run safety is activated, because the the switch-on pressure is set too highBy turning the pressure setting screw anti-clockwise, the switch-on pressure will be reduced
Pump start and stop constantlyThe switch-on pressure is set too highOutput side leakingBy turning the pressure setting screw anti-clockwise, the switch-on pressure will be reducedCheck the outlet hose and connections
Pump does not stopOutput side leakingThe switch-on pressure is set too highCheck the outlet hose and connectionsBy turning the pressure setting screw anti-clockwise, the switch-on pressure will be reduced

ENVIRONMENT

Faulty and/or discarded electrical or electronic apparatus have to be collected at the appropriate recycling locations.

Only for EC countries

Do not dispose of power tools into domestic waste. According to the European Guideline 2012/19/EC for Waste Electrical and Electronic Equipment and its implementation into national right, power tools that are no longer usable must be collected separately and disposed of in an environmentally friendly way.

WARRANTY

VONROC products are developed to the highest quality standards and are guaranteed free of defects in both materials and workmanship for the period lawfully stipulated starting from the date of original purchase. Should the product develop any failure during this period due to defective material and/or workmanship then contact VONROC directly.

The following circumstances are excluded from this guarantee:

  • Repairs and or alterations have been made or attempted to the machine by unauthorized service centers;
  • Normal wear and tear;
  • The tool has been abused, misused or improperly maintained;
  • Non-original spare parts have been used.

This constitutes the sole warranty made by company either expressed or implied. There are no other warranties expressed or implied which extend beyond the face hereof, herein, including the implied warranties of merchantability and fitness for a particular purpose. In no event shall VONROC be liable for any incidental or consequential damages. The dealers remedies shall be limited to repair or replacement of nonconforming units or parts.

The product and the user manual are subject to change. Specifications can be changed without further notice.

VEILIGHEIDSWAARSCHUWINGEN

DIT APPARAAT MAG WORDEN GEBRUIKT DOOR KINDEREN VANAF 8 JAAR EN DOOR PERSONEN MET VERMINDERDE LICHAMELIJKE, ZINTUIGLIJKE OF GEESTELIJKE VERMOGENS, OF MET EEN GE-BREK AAN ERVARING EN KENNIS, MITS ZIJ ONDER TOEZICHT STAAN OF GEINSTRUEERD ZIJN BETREF-FENDE HET VEILIG GEBRUIK VAN HET APPARAAT EN ZICH BEWUST ZIJN VAN DE ERMEE VERBON-DEN RISICO'S. KINDEREN MOGEN NIET MET HET APPARAAT SPELEN. REINIGING EN GEBRUIKERSON-DERHOUD MOGEN NIET DOOR KINDEREN ZONDER TOEZICHT WORDEN UITGEVOERD. OM GEVAARLIJKE SITUATIES TE VOORKOMEN MOET HET NETSNOER DOOR DE FABRIKANT, ZIJN SERVICEMEDEWER-KERS OF ANDERE GEKWALIFICEERDE PERSONEN WORDEN VERVANGEN ALS HET IS BESCHADIGD. DE STEKKER MOET UIT HET STOPCONTACT WORDEN GETROKKEN VOORDAT U HET APPARAAT REINIGT OF ONDERHOUD UITVOERT.

LED indicators Operating status
LED-power (6)The pressure switch is connected to the power supply. The pressure switch is ready for use.
LED-failure (7)The pump is running dry without water. The dry-run safety is activated. Use the pump's operating manual to find the cause of the failure and correct it. Then restart the pump by pressing the reset button (5) on the pressure switch.
LED-on (8)The pressure switch has tripped, the socket is live. The pump is operating.
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Vonroc

Model : GP804AA

Category : Pressure switch