TB 73 - Measuring equipment Testboy - Free user manual and instructions
Find the device manual for free TB 73 Testboy in PDF.
User questions about TB 73 Testboy
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Measuring equipment in PDF format for free! Find your manual TB 73 - Testboy and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TB 73 by Testboy.
USER MANUAL TB 73 Testboy
natural_image
Line drawing of a mobile phone with a screen and antenna (no text or symbols)Testboy® TB 73
Version 1.1

Testboy ^® TB 73 3
Bedienungsanleitung

Testboy® TB 73 9
Operating Instructions

Testboy ^® TB 73 15
Mode d'emploi

Testboy ^® TB 73 21
General safety notes 10
Operation 12
Operation 13
Unit of measurement 13
Data storage 13
Flip display 13
Average value 13
Deviation/tolerance of the real measurement 13
Calibrations 13
Substrate blocks and standard films 14
Specifications 14
Maintenance and cleaning 14
Replacing the battery 14
Operation
Safety notes

WARNING
Sources of danger are mechanical parts, for example, which can cause serious personal injury.
Objects are also at risk (e.g. damage to the instrument).

WARNING
An electric shock can result in death or serious personal injury, and also functional damage to objects (e.g. damage to the instrument).

WARNING
Never point the laser beam towards the eyes directly or indirectly, via reflective surfaces. Laser radiation can cause irreparable damage to the eyes. The laser beam must be deactivated when measuring close to people.
General safety notes

WARNING
Unauthorised modification and/or changes to the instrument are not permitted, for reasons of safety and approval (CE). In order to ensure safe and reliable operation using the instrument, you must always observe the safety instructions, warnings and the information contained in the section "Intended use".

WARNING
Please observe the following information before using the instrument:
Do not operate the instrument anywhere near electrical welders, induction heaters or other electromagnetic fields.
Further to abrupt temperature fluctuation, the instrument must be allowed to adjust to the new ambient temperature for approx. 30 minutes before using it, in order to stabilise the IR sensor.
Do not expose the instrument to high temperatures for a long period of time.
Avoid dusty and humid environments.
Measuring instruments and their accessories are not toys, and must be kept out of the reach of children!
In industrial facilities, the accident prevention regulations for electrical systems and equipment, established by the employer's liability insurance association, must be observed.
Intended use
The instrument is intended strictly for use in applications described in the operating instructions. Any other usage is considered improper and forbidden, and can result in accidents or the destruction of the instrument. Any such application will result in the immediate expiry of all guarantee and warranty claims on the part of the operator against the manufacturer.

Remove the batteries if the instrument is not in use for a long period of time, in order to protect the instrument from damage.

We assume no liability for damages to property or personal injury caused by improper handling or failure to observe the safety instructions. Any warranty claim expires in such cases. An exclamation mark in a triangle indicates safety notices in the operating instructions. Read the instructions completely before beginning the initial commissioning. This instrument is CE-approved and thus fulfils the required guidelines.
We reserve the right to alter specifications without prior notice.
© 2022 Testboy GmbH, Germany.
Disclaimer

The warranty claim expires in cases of damages caused by failure to observe the instructions!
We assume no liability for any resulting damage!
Testboy is not responsible for damage resulting from
| failure to observe the instructions,
changes to the product that have not been approved by Testboy or
the use of replacement parts that have not been approved or manufactured by Testboy
the use of alcohol, drugs or medication.
Accuracy of the operating instructions
These operating instructions have been compiled with due care and attention. No guarantee is given that the data, illustrations and drawings are complete or correct. All rights reserved with regard to changes, printing mistakes and errors.
Disposal
Dear Testboy customer: purchasing our product gives you the option of returning the instrument to suitable collection points for waste electrical equipment at the end of its lifespan.

The WEEE directive regulates the return and recycling of electrical appliances. Manufacturers of electrical appliances are obliged to take back and recycle all electrical appliances free of charge. Electrical devices may then no longer be disposed of through conventional waste disposal channels. Electrical appliances must be recycled and disposed of separately. All equipment subject to this directive is marked with this logo.
Disposal of used batteries

As an end user, you are legally obliged (battery law) to return all used batteries; disposal with normal domestic waste is prohibited!
Batteries containing contaminant material are labelled with adjacent symbols indicating the prohibition of disposal with normal domestic waste.
The abbreviations used for the respective heavy metals are:
Cd = cadmium, Hg = mercury, Pb = lead.
You can return your used batteries free of charge to collection points in your community or anywhere where batteries are sold!
Certificate of quality
All activities and processes carried out within Testboy GmbH relating to quality are monitored permanently within the framework of a Quality Management System. Furthermore, Testboy GmbH confirms that the testing equipment and instruments used during the calibration process are subject to a permanent inspection process.
Declaration of conformity
The product conforms to the present directives. For more detailed information, go to www.testboy.de
Operation
Thank you for purchasing the Testboy® TB 73
The Testboy® TB 73 is for measurements on all metallic substrates
Depending on the substrate, the letter "Fe" (ferrous/steel) or "NFe" (non-ferrous) is automatically displayed for each measurement. 2 in 1 type combines two probes in one meter and automatically identify the substrate materials.
Depending on the substrate, the symbol Fe or NFe is displayed on the screen.
Operation
Hold the gauge and push the integrated probe vertically against the costing surface turns on the power and starts the measurement automatically, and power is cut off after 30 seconds.
Keep the probe on the coating and hold it steadily for a while till the buzzer sounds, take up the gauge and read the measurement.
Unit of measurement
Press the button "μm/mil" to switch between micron (μm) and mil.(mil).
Data storage
Press the button "M" to read the final 20 measurements, "0" displays at lower corner of LCD screen, the final 20 measurements can be shown in sequence by pressing the button "+/-".
Flip display
Press the button "Flip" to turn the display upside down for easy reading when measurement is taking on top, side or bottom surfaces.
Average value
"Mean" indicates the average (mean) value.
Deviation/tolerance of the real measurement
"Sdev" indicates the deviation of the real measurement in relation to the instrument tolerance.
Calibrations
a. Zero calibration: press "+" for 2 seconds, "000" displays on the screen, then take a normal measurement on uncoated metals, the reading is calibrated to zero automatically.
b. Calibration with standard films: after measuring the calibration film, press "M" for 2 seconds, then adjust the reading to the right value by pressing "+/-".
c. Restore factory defaults: press "-" for 2 seconds, "0, 00, 000 ..." displays in sequence on the screen, the factory defaults are restored. The function is useful when standard films are not available for calibration.
Substrate blocks and standard films
Available with the package for calibration or self test.
Specifications
Range: 0-2000μm, 0-50 mil
Accuracy: ± (2μm +3%), ± (0.1 mil + 3%)
Maintenance and cleaning
Use a dry cloth, without cleaning agent, to clean the housing at regular intervals. Do not use any abrasive or scouring agents, or solvents.

To prevent electric shocks, do not allow moisture to ingress the housing.
Replacing the battery
Procedure:
If the operating voltage of the battery is insufficient, the symbol LCD display; the battery must then be replaced.
Use a screwdriver to release the safety screw at the rear. Remove the used batterie and replace with new batterie, type 1.5 V AAA.
Replace the cover and secure with the screw.


Batteries must not be disposed of with normal domestic waste.
There will be a collection point near you!
Table des matières
Utilisation 16
Cd = cadmium, Hg = mercure, Pb = plomb.
Cd = cadmium, Hg = kwikzilver, Pb = lood.
Germany info@testboy.de