MX 406B - Measuring equipment METRIX - Free user manual and instructions
Find the device manual for free MX 406B METRIX in PDF.
| Product Type | Portable Analog Megohmmeter |
| Brand | Metrix |
| Model | MX 406B |
| Category | Electrical Measurement Equipment |
| Dimensions (L × W × H) | 155 × 98 × 40 mm |
| Weight | 410 g |
| Power Supply | 3 x 1.5 V LR03 alkaline batteries (supplied); typical battery life 850 measurements of 5 s (1000 measurements with DURACELL MN2400 ULTRA batteries) |
| Display | Analog needle display, dial with logarithmic scales (blue for insulation, green for continuity, red for voltage) |
| Main Functions | AC+DC TRMS voltage measurement (0-440 V), insulation test at 50 V / 250 V / 500 V (up to 200 MΩ), continuity test (up to 10 Ω with buzzer < 2 Ω), battery test |
| Safety | CAT III 300 V with respect to earth, pollution degree 2, compliant with NF EN 61010-1 + A2; input protection up to 600 VAC for insulation, 440 VAC for continuity and voltage |
| Electromagnetic Compatibility | According to NF EN 61326-1; max. influence in radio field at 3 V/m: 3 × accuracy class |
| Operating Temperature | 0 °C to 45 °C (reference 18 °C to 28 °C) |
| Relative Humidity | 80 % up to 31 °C |
| Maximum Altitude | 2000 m |
| Enclosure Protection Rating | IP 40 |
| Supplied Accessories | 1 remote control probe, 1 black angled safety lead, 1 black crocodile clip, 3 LR03 batteries, 1 operating manual in 5 languages |
| Maintenance and Cleaning | Clean with a damp cloth and soap; do not use abrasive products or solvents |
| Warranty | 12 months from the date of availability |
| Repairability | Repair under warranty or out of warranty at MANUMESURE regional agencies; outside mainland France, return to the distributor |
| Spare Parts / Optional Accessories | Carrying case AE0226, set of test probes HA2045, remote control probe HA1340, elastic strap AF009701S, set of leads AG1049, set of crocodile clips HA2050 |
Frequently Asked Questions - MX 406B METRIX
User questions about MX 406B METRIX
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Measuring equipment in PDF format for free! Find your manual MX 406B - METRIX and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MX 406B by METRIX.
USER MANUAL MX 406B METRIX
User's manual ENGLISH Chapter

Bedienungsanleitung
DEUTSCH
Kapite
| 1 Tripod connector input terminals | 8 VAC + DC scale |
| 2 Common input terminal | 9 200 MΩ - 500 V and 250 V insulation meas. |
| 3 Voltage present indicator | 10 20 MΩ - 50 V insulation measurement |
| 4 200 MΩ - 500 V scale | 11 10 Ω - continuity measurement |
| 5 200 MΩ - 250 V scale | 12 AC + DC voltage measurement |
| 6 20 MΩ - 50 V scale | 13 Instrument battery test |
| 7 10 Ω scale | 14 Power off |
BESCHREIBUNG
1.1. Precautions and safety measures 8
1.1.1.Before use 8
1.1.2.During use 9
1.1.3. Symbols 9
1.1.4. Instructions 9
1.2.Safety devices.. 9
1.3.Guarantee 9
1.4.Metrological verification.. 9
2. INSTRUMENT DESCRIPTION 10
2.1. Power supply. 10
2.1.1. Self-checking of batteries : TEST 10
2.1.2. Replacing the batteries 11
2.2. Input terminals 11
2.3. Scale 11
3. FUNCTIONAL DESCRIPTION 11
3.1. AC + DC voltage measurement 11
3.2.Continuity test 12
3.3. Insulation measurement at 50V 250 V or 500 V .12
4. GENERAL CHARACTERISTICS 13
4.1. Characteristics 13
4.2.To order 13
1. GENERAL INSTRUCTIONS
You have just purchased a megohmmeter and we thank you for your confidence in us.
This instrument complies with IEC safety standard 61010-1 + A2, dealing with electronic measurements. If you want to obtain the best service, please read these instructions carefully and respect usage precautions.
1.1. Precautions and safety measures
1.1.1.Before use
- This instrument was designed for use indoors in an environment with a degree of pollution 2, altitude >2000m , temperature between 0^ and 45^ , and relative humidity 80% up to 31^ .
- It can be used in category III installations, for voltages never exceeding 300V with respect to the earth.
Definition of installation categories according to IEC standard 664 :
CATI: CAT I circuits are protected by devices limiting transient overvoltages to a low level. Example protected electronic circuits
CAT II: CAT II circuits are power supply circuits for domestic or similar appliances that may include transient overvoltages of average value. Example: power supply for household appliances and portable tools
CAT III: CAT III circuits are for the power supply of high power appliances that may draw large transient overvoltages. Example: power supply of industrial machines or appliances
CAT IV: CAT IV circuits may have very high transient overvoltages. Example: energy arrival
- The user should respect normal safety rules when he uses the megohmmeter, in order to:
protect himself against dangers due to electrical current, protect the megohmmeter against any false maneuvers.
- The cables and connection accessories used must satisfy IEC standard 1010-2-031 + A2 and must be designed for a rated voltage and overvoltage category at least equal to the values for the circuits on which the measurements are made.

This instrument outputs a DC voltage of 500 V on the 20C MΩ rating. Never touch the probe tip when the probe is activated.
1.1.2. During use
- Never exceed the limiting protection values given in the specifications specific to each measurement type.
1.1.3. Symbols

Refer to the user's manual. Incorrect use may result in damage to the device or its components.

Risk of electric shock

Earth
1.1.4. Instructions
- Any adjustment, maintenance or repair to the megohmmeter when live must be done by qualified personnel after reading the instructions in this manual.
- A qualified person is anyone familiar with the installation, construction, usage and the dangers involved. This person is authorized to switch the installation and equipment on or off in accordance with safety rules.
- Before opening the device, always disconnect it from all measurement circuits and make sure that there is no static electricity charge which could damage internal elements.
- When the instrument is open, some internal capacitors may maintain a dangerous potential even after the instrument is switched off.
If there are any abnormal faults or constraints, take the instrument out of service and prevent it from being used until it has been verified.
1.2. Safety devices
- The switch has two stops that prevent it from rotating. There are four safety bushes at the top of the instrument.
It is impossible to access the battery box without firstly disconnecting measurement cables.
1.3. Guarantee
Unless specifically mentioned otherwise, the guarantee is applicable for 12 months after the equipment has been handed over (extract from our general conditions of sale available on request).
1.4. Metrological verification

A periodic verification is necessary, as for all measurement or test instruments.
For checking and calibrating your instrument, please contact our accredited laboratories, the manufacturer subsidiary or agent in your country.
1.5. Repair
Return your instrument to your distributor for any work to be done within or outside the guarantee.
1.6. Maintenance
Clean the instrument with a damp cloth and soap. Never use abrasive products or solvents.
2. INSTRUMENT DESCRIPTION
This megohmmeter is designed to provide you with a strong guarantee of safety, maximum protection and unequalled performance.
It is a portable, professional, standalone measurement instrument for use by electricians, in order to measure the following magnitudes :
- AC -DC voltages (TRMS) from 0 to 440V
resistances (200 MΩ at 500 V dc)
resistances (200 MΩ at 250 V dc)
resistances (20 MΩ at 50 V dc) - continuity up to 10 (at 200mA )
These magnitudes can be accessed using a rotary switch.
2.1. Power supply
The megohmeter is powered by three standard 1.5 V batteries (type LR03) providing an endurance of about 850 × 5 s measures. For an endurance of one thousand measures, use the DURACELL MN 2400 ULTRA type.
Keep in mind that the power needed for the battery test (see below) is equal to one measure. It is therefore advised to perform this test only once every 60 measures.
2.1.1. Self-checking of batteries " TEST"
Before carrying out a measurement campaign, it is important to check that the instrument power supply batteries are in good condition.
The ---^EST position of the rotary switch indicates the state of the batteries (it is necessary to press the probe push button).
On the scale, there is an area with two different colours :
- if the needle is positioned in the green area = batteries are charged,
- if the needle is positioned in the red area = batteries are discharged.
2.1.2. Replacing the batteries

Unplug measurement circuit test cables, put the rotary switch to the off position and remove test cables from the instruments.
Proceed as follows to replace the megohmmeter batteries :
- Remove the four screws from the back of the instrument.
- Remove the lower box.
- Replace the batteries, taking care that they are in the right direction.
- Close the instrument.
2.2. Input terminals
Measurements are made with a specific probe (equipped with a push button) connected to the input terminals through a grey cable and a tripod connector, and with a black cable and a crocodile clip.
2.3. Scale
The measurement readout is of the analog type. The megohmmeter is fitted with a graduated scale and a needle.
The scale is graduated to give a direct reading without any multiplication factor (logarithmic graduation).
- the scale length is 79 mm (circular arc according to IEC standard 51)
-logarithmic scale for the 200M 500 V range (blue scale)
-logarithmic scale for the 200M 250 V range (blue scale)
-logarithmic scale for the 20M 50V range (blue scale)
-logarithmic scale for the 10 range (green scale) - 400 VAC + DC linear scale (red scale)
- TE3T scale containing 2 colors (red and green scale).
3. FUNCTIONAL DESCRIPTION
As soon as the cables are connected to an AC voltage exceeding 100V , an indicator (located on the scale) lights up regardless of the switch position. For example, it may thus indicate the presence of mains voltage.
3.1. AC + DC voltage measurement
- Measurement range: 0 to 440VAC + DC on the V2 position
The instrument gives the value in TRMS, the probe push button is ineffective in this function.
Accuracy: ± 2.5% (of full scale)
Protection:440V
3.2. Continuity test
A current is generated through the resistor to be measured. The voltage drop measured at its terminals is used to deduce its value.
Measurements must only be made on parts of installations or instruments that are out of voltage.
The measurement is automatic when pressing the probe push button.
Measurement range: 0 to 10
You will hear a beeper for resistances of 2 or less.
(Accuracy: -0 Ω / +0.5 Ω)
Measurement current: ≥ 200 mA for R ≤ 3
- Input protection : up to 440 Vac by CTP + MOSFET
Voltage at no load: 5 V
Accuracy : class 10 over the entire scale
3.3. Insulation measurement at 50V 250 V or 500 V
High voltage is generated at the terminals of the resistor to be measured. The voltage drop measured at the terminals of a known internal resistor in series with the resistor to be measured is used to deduce the value of the resistor.
Tests should only be carried out on circuits out of voltage (the mains light on the instrument scale must be off after disconnecting the test leads and before pressing the probe push button).
Connect the circuit to be measured to the instrument terminals, before starting the measurement.
Measurement results may be distorted by the impedances of additional circuits connected in parallel or by transient currents.
After a measurement, the high voltage present on the device under test discharges through the leads and the instrument if the switch is set to V2 position.
Measurement range: 200k to 200 MΩ at 250 V and 500 V
10 kΩ to 20 MΩ at 50 V
Measurement current: >1mA for R < 50k at 50V
1mAforR<250kΩat250V
1 mA for R < 500 kΩ at 500 V
Protection of inputs: up to 600 V AC
No load voltages: 60 V dc on the 50 V range
320 V
650V
DC on the 250 V range
DC on the 500 V range
Accuracy: according to EN 61557
4. GENERAL CHARACTERISTICS
4.1. Characteristics
Safety
according to IEC 61010-1 + A1 + A2,
class 2, CAT III 300V with respect to the earth
degree of pollution 2
according to IEC 61557
Electromagnetic compatibility EMC Transmission acc. to EN 61326-1
Immunity acc. to EN 61326-1
Max. Influence in electromagnetic fields at 3V / m (NF EN 61000-4-3): 3 times the class of accuracy
Environment
Reference temperature 18^ to 28^
Usage temperature 0^ to 45^
Influence of temperature 0.1 times the class /°C
Box
self-extinguishing
Degree of protection IP 40
material
Power supply
3 batteries -1.5 V alkaline type (LR03) :
typical endurance 850^*5 s measurements
- DURACELL MN 2400 ULTRA type :
typical endurance 1000 measurements
Reference voltage
1.45 V min. per battery
Mechanical characteristics
Dimensions
155× 98× 40mm
Weight
410g
4.2. To order
Megohmmeter (with carry bag) MX0406B-E
Megohmmeter (without carry bag) MX0406B
delivered with :
1 remote control probe,
1 black straight-elbow safety cable.
1 black crocodile clip,
3 LR 03 1.5 V batteries,
1 user's manual in five languages
Accessories
Set of 2 test leads (red + black) HA2045
Spare parts
Carry bag for "no hands" use of the MX 406B AE0226
Remote control probe. HA1340
Elastic bracelet (for use around the wrist) AF009701S
Set of 2 safety leads (red + black). AG1049
Set of 2 crocodile clip (red + black) HA2050