P250FW - Thermometer Comark - Free user manual and instructions
Find the device manual for free P250FW Comark in PDF.
| Brand | Comark |
| Model | P250FW |
| Product Type | Waterproof digital pocket thermometer |
| Intended Use | Quick check of frozen, refrigerated, cooked foods and frying oils |
| Power Supply | 2 AA alkaline batteries |
| Approximate Battery Life | Continuous operation until automatic shutdown after 60 minutes |
| Dimensions (approx.) | 150 mm length, 30 mm width, 20 mm thickness (probe folded) |
| Weight (with batteries) | Approximately 50 g |
| Measurement Range | Not specified, but designed for HACCP temperatures (≤40°F, 140-165°F, ≥165°F) |
| Main Features | Measurement with folding probe, digital display, audible and visual alarm for HACCP zones |
| HACCP Zones (P250FW) | Frozen (yellow) <40°F, Hot hold (green) 140-165°F, Ground beef (red) >165°F |
| Audible and Visual Signal | Beep and LED flash according to the HACCP zone reached |
| On/Off | Deploy the probe to turn on, fold to turn off |
| Auto Shutdown | After 60 minutes of inactivity |
| Low Battery Indicator | Empty battery symbol, then displays "BATT" before shutdown |
| Maintenance and Cleaning | Wipe with Comark wipe or mild detergent; do not put in dishwasher |
| Battery Replacement | Yes, via Phillips screwdriver or flat-head screwdriver; observe polarity; check sealing gasket |
| Safety | Do not touch live components, do not use in microwave, do not measure body temperature |
| Precautions | Sharp probe, avoid excessive force; do not use as a lever |
| Warranty | 2 years against defects in materials and workmanship |
| Environmental Standards | Complies with WEEE directive; used batteries to be recycled |
Frequently Asked Questions - P250FW Comark
User questions about P250FW Comark
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Thermometer in PDF format for free! Find your manual P250FW - Comark and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. P250FW by Comark.
USER MANUAL P250FW Comark
WATERPROOF POCKETHERM THERMOMETER
P125W
P125W/82
P250W
P250FW
USER MANUAL
Introduction
Pocketherm P125W, P125W/82, P250W & P250FW are pocket sized waterproof handheld folding probe digital thermometers. Pocketherm thermometers are intended for quick checks on frozen, chilled or cooked food in catering environments. In addition P250W and P250FW can be used for checking frying oil temperatures.
There is audible and visual indication when temperature measurements fall into any of three HACCP temperature zones for frozen food, chilled food and cooked meat.
Safety Information

Revent Electric Shock
To avoid electric shock do not allow the probe to come into contact with live electrical parts.

Maintaining Product Safety & Reserving Comark Warranty
- Only use the instrument for its intended purpose.
- Do not use in a microwave oven.
- Pocketerm is not dishwasher safe.
- Do not use the instrument beyond its operating temperature range.
- Avoid excessive force on the probe tip.
- Do not use the probe as a lever.
Personal Safety
The probe tip is sharp and can cause injury if misused.
- Do not measure body temperatures with Pocketerm.
Waste Electrical & Electronic Equipment Directive (WEEE)
- This instrument must not be disposed of in general waste. Instead take it to your local authority's recycling centre for small electrical goods. Within the European Union, Comark operates a Take Back scheme for our end-of-life products. Contact us for details.
- Dispose of waste batteries in local recycling facilities.
Operation
Switching On/Off
Swing out the probe to switch on the thermometer. Swing back the probe to switch off. Clip the tip behind the retainer to avoid damage to clothing or injury. To conserve battery life, the thermometer will automatically switch off after 60 minutes. Fold back then unfold the probe to continue use.
Low Battery Indication
Low battery is indicated by an empty battery symbol appearing in the top left corner of the display. Replace the battery as soon as possible after this symbol appears. If the battery is too low, BATT is displayed briefly
before the instrument switches itself off.
Taking Measurements
Insert the tip of the probe approximately 20mm (3/4") into the food item to be checked. Allow a few seconds for the probe to reach stable temperature then note the reading. If the probed item is within one of three HACCP zones then the beeper will sound and the corresponding indicator will flash as below:
P125W / P250W
Frozen: (Yellow) Below -18°C
Chilled: (Green) 0^ C - 5^ C
Cooked: (Red) Above 75^
P125W/82
Frozen: (Yellow) Below -18°C
Chilled: (Green) 0^ - 5^
Cooked: (Red) Above 82^
P250FW
Cold Hold: (Yellow) Below 40^
Hot Hold: (Green) 140^ - 165^
Ground Beef: (Red) Above 165^
Maintenance
Cleaning
To maintain probe hygiene wipe regularly with Comark probe wipe. Use only domestic kitchen cleaners or mild detergents to clean this instrument. Do not use aggressive cleaning chemicals or solvents,
these will attack plastics and cause damage.
Battery Replacement
To replace the battery, remove the battery cover retaining screws on the rear of the instrument using a Philips or fl at blade screwdriver.* Remove the two cells and dispose in local recycling facilities. Replace with AA size alkaline cells only carefully observing the correct polarity. Visually check that the battery cover and compartment are clean and free of debris. Check that the seal in the battery compartment is not displaced from the locating groove before refi tting the cover. Take care not to over-tighten the screws when refi tting the cover.
- Philips No 1 or 5mm fl at blade screwdriver,
Technical Support
Please see: www.comarkinstruments.com or www.comarkUSA.com for details.
Warranty
This Comark Instruments product will be free from defects in material and workmanship for two years from the date of purchase and applies worldwide. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. To obtain service during the warranty period, visit the Service and Repair page on our website -
www.comarkinstruments.com or www.comarkUSA.com for instructions on obtaining a Return Material Authorization (RMA) then send the product to our Service Centre with a description of the problem.
Einleitung
Activation/désactivation
Assistance technique
superiore a 165^
Manutenzione
Pulizia
Specific cation General Specific cation
| Sensor Type P125W / P125W/82 P250W / P250FW | Thermistor Type T Thermocouple |
| Measurement Range P125W / P125W/82 P250W / P250FW | -40 °C to +125°C /-40°F to +257°F -50°C to +250°C /-58°F to +482°F |
| Scales P125W / P125W/82 P250W / P250FW | °C °F |
| Displayed Resolution 0.1° | |
| System Accuracy P125W / P125W/82 (-20 to +30°C operating) P250W / P250FW (0 to 40°C/32 to 104°F operating) | ±0.5°C, -20°C to +70°C/±0.9°F, -4°F to +158°F ±1°C full range < 125°C/ 257°F, 0.3% ±(0.75°C/1.35°F) > 125°C/ 257°F, 0.7% ±(0.25°C/0.45°F) |
| Response Time (T99) 5s | |
| Environment Operating Temperature Storage Temperature Humidity | -20°C to +50°C /-4°F to +122°F -30°C to +70°C /-22°F to +158°F 10 to 90% non-condensing |
| HACCP Zones P125W / P250W Frozen Chilled Cooked | T ≤ -18°C 0°C ≤ T ≤ 5°C T ≥ 75°C |
| HACCP Zones P125W/82 Frozen Chilled Cooked | T ≤ -18°C 0°C ≤ T ≤ 5°C T ≥ 82°C |
| HACCP Zones P250FW Cold hold Hot hold Ground beef | T ≤ 40°F 140°F ≤ T ≤ 165°F T ≥ 165°F |
| Power 2 x alkaline AA cells (ANSI 15A IEC LR6) | |
| Battery Life P125W / P125W/82 P250W / P250FW | 4000h 3000h |
| Enclosure Ingress Protection IP65 | |
Weight & Measures
| Dimensions | |
| Case Size | 170 x 52 x 20 mm |
| Probe length | 110mm |
| Weight | 140g (incl. battery) |
| Packing Box | 175 x 56 x 29 mm |
| Case Materials | |
| Case | Mixed: ABS & PC with BioCote® anti-microbial protection moulded in. |
| Probe | 316 Stainless Steel |
Compliance
| EMC Directive EMC Standard Radiated RF emissions 30MHz-1GHz Electrostatic discharge Radiated RF immunity * Power frequency magnetic fi eld immunity | EC Directive 2014/30/EU EN 61326-1:2013, EN 61326-2-1:2013 (Portable Equipment Environment) EN 55011:2009+A1:2010 EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008+A2:2010 EN 61000-4-8:2010 |
| Product Safety EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control and laboratory use. Part-1: General requirements | |
| RoHS Directive EC Directive 2011/65/EU RoHS | |
| Thermometers for Chilled/Frozen Food (P125W / P125W/82 only) | EN 13485:2001 Thermometers for chilled/frozen food and ice cream Application: Air and Product Environment: E (Portable) Suitability: S (Storage) Accuracy: 0.5 Range: -40°C to +125°C Annual recalibration recommended |
*P250W / P250FW readings may be temporarily affected in the presence of radio frequency interference.
Comark Instruments
52 Hurricane Way, Norwich, Norfolk NG6 6JB United Kingdom
Tel: +44 (0) 207 942 0712
Fax: +44 (0) 207 942 0714
Email: sales@comarkinstruments.com
Website: www.comarkinstruments.com
Comark Instruments
PO Box 500
Beaverton, OR 97077 USA
Tel: 5036435204
Fax: 5036445859
Email: sales@comarkusa.com
Website: www.comarkusa.com
Part No 20337/1 (05/16)
© Comark Instruments