Kübler CODIX 521 - Measuring equipment

CODIX 521 - Measuring equipment Kübler - Free user manual and instructions

Find the device manual for free CODIX 521 Kübler in PDF.

📄 40 pages English EN Download 💬 AI Question
Notice Kübler CODIX 521 - page 9
View the manual : Français FR Deutsch DE English EN Español ES Italiano IT
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about CODIX 521 Kübler

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual CODIX 521 - Kübler and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CODIX 521 by Kübler.

USER MANUAL CODIX 521 Kübler

SET-Wert -19 9999 ...

1.1 Safety instructions and warnings

Only use this display

Kübler CODIX 521 - Safety instructions and warnings - 1

– in a way according to its intended purpose
- if its technical condition is perfect
– adhering to the operating instructions and the general safety instructions.

1.2 General safety instructions

  1. Before carrying out any installation or maintenance work, make sure that the power supply of the digital display is switched off.
  2. Only use this digital display in a way according to its intended purpose:

If its technical condition is perfect.

Adhering to the operating instructions and the general safety instructions.

  1. Adhere to country or user specific regulations.
  2. The digital display is not intended for use in areas with risks of explosion and in the branches excluded by the standard EN 61010 Part 1.
  3. The digital display shall only operate if it has been correctly mounted in a panel, in accordance with the chapter "Technical features".

1.3 Use according to the intended purpose

The digital display may be used only as a panel-mounted device. Applications of this product may be found in industrial processes and controls, in manufacturing lines for the metal, wood, plastics, paper, glass, textile and other processing industries. Over-voltages at the terminals of the digital display must be kept within the limits in Category II.

If the digital display is used to monitor machines or processes in which, in case of a failure of the device or an error made by the operator, there might be risks of damaging the machine or causing accidents to the operators, it is your responsibility to take appropriate safety measures.

1.4 Description

CODIX 521

Please note: Read first chapter 2 of CODIX 524 and go on on page 2.

CODIX 522

Please note: Read first chapter 2 of CODIX 524 and go on on page 4.

CODIX 523

Please note: Read first chapter 2 of CODIX 524 and go on on page 6.

CODIX 524

CODIX 524 is a multipurpose device. Depending on the programmed basic function, the device operates like

  • the pulse counter CODIX 521 (see page2) or
  • the frequency meter CODIX 522 (see page 4) or
    • the time meter CODIX 523 (see page 6)

2. Setting of the operating pa ra me ters

a. Press both front side keys keys and switch on the supply voltage or, if the supply voltage is already on, press both keys simultaneously during 5 s.
b. The display shows

$$ \boxed {P r o f} $$

c. After releasing the keys, the display shows

$$ \boxed {0 0} $$

c1. Hold the left key pressed and press the right key to leave the programming operation.
c2. Press the right key to switch to

$$ \boxed {Y E S} $$

d. Hold the left key pressed and press the right key to switch to the first parameter.
e. After releasing the keys, the display alternates between the menu title and the current menu item setting. After pressing any key, only the menu item setting is displayed.
f. Pressing the right key, the menu item setting will be switched to the next value. If figures are to be input (e.g. when setting the scaling factor), select first the decade using the left key, and then set the value using the right key.
g. Hold the left key pressed and press the right key to switch to the next menu item.
h. The last menu title "EndPro" allows, when selecting "Yes", to exit the programming menu and to take over (store) the new values. If "no" is selected, the programming routine is repeated, the latest values set remaining active. They can now be checked again or modified.

3. Programming routine

The first menu item is the selection of the basic operating mode, which determines the functions of the device.

PNode

Kübler CODIX 521 - PNode - 1

Operating mode pulse counter. Continued in point 4. of CODIX 521 on page 2

Kübler CODIX 521 - PNode - 2

Operating mode frequency meter. Continued in point 4. of CODIX 522 on page 4

Kübler CODIX 521 - PNode - 3

Operating mode time meter. Continued in point 4. of CODIX 523 on page 6

Pulse counter/Po si ti on indicator CODIX 521

(CODIX 524: Operating mode pulse counter)

1. Description

  • 6-digit display counter with SET/RESET-function
  • Red LED display, character height 8 mm
    • Display range from -199 999 to 999 999
  • Leading zeros suppression
  • Programming via two setting keys on the front side
  • During programming, the display guides the user with text prompts
  • Counter operating modes:
    Count input INP A + count direction input INP B (Cnt.Dir)
    Differential count INP A - INP B (up.dn)
    Totalising INP A + INP B (up.up)
    Count Up/Down INP A 90° INP B x 1 (quAd)
    Count Up/Down INP A 90° INP B x 2 (quAd2)
    Count Up/Down INP A 90° INP B x 4 (quAd4)
    • Optional optocoupler output

2. Inputs

INP A

Dynamic count input.

INP B

Dynamic count input.

SET/RESET

Dynamic SET/RESET input. Linked in parallel to the red SET/RESET key. Resets the counter to the predefined setting value.

3. Optocoupler output (optional)

Active if count value < 0. Simple preset counter can be realized, when using subtract mode.

4. Programming routine

The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine.

The first values stated correspond to the factor settings

4.1 Polarity of the inputs

Kübler CODIX 521 - Polarity of the inputs - 1

Kübler CODIX 521 - Polarity of the inputs - 2

npn: switching for 0 V

Kübler CODIX 521 - Polarity of the inputs - 3

pnp: switching for +U_B

4.2 Switching on the 30 Hz filter (INP A, INP B)

Kübler CODIX 521 - Switching on the 30 Hz filter (INP A, INP B) - 1

The filter provides input damping*

Kübler CODIX 521 - Switching on the 30 Hz filter (INP A, INP B) - 2

30 Hz filter off ( f_max )

Kübler CODIX 521 - Switching on the 30 Hz filter (INP A, INP B) - 3

30 Hz filter on

4.3 Input mode

Kübler CODIX 521 - Input mode - 1

Kübler CODIX 521 - Input mode - 2

Count input and count direction input

INP A: Count input

INP B: Count direction input

Kübler CODIX 521 - Input mode - 3

Differential input

INP A: count input adding

INP B: count input subtracting

Kübler CODIX 521 - Input mode - 4

Totalising

INP A: count input adding

INP B: count input adding

Kübler CODIX 521 - Input mode - 5

Quadrature input

INP A: count input 0°

INP B: count input 90°

9u8d 2

Quadrature input with pulse doubling

INP A: count input 0°

INP B: count input 90°

Each pulse edge of INP A will be counted

9u8d 4

Quadrature input with pulse quadrupling

INP A: count input 0°

INP B: count input 90°

Each pulse edge of INP A and INP B will be counted.

4.4 Multiplying factor

Factor

010000

It can be set from 00.0001 up to 99.9999.

999999

The decimal point is set to 4 decimal places.

„0“ is not accepted!

4.5 Dividing factor

d:0:50

010000

It can be set from 00.0001 up to 99.9999.

999999

The decimal point is set to 4 decimal places.

„0“ is not accepted!

4.6 Decimal point

dP

The decimal point defines the way of displaying the count values. It does not affect counting.

0

0 no decimal place

0.0 one decimal place

0.00 two decimal places

0.000 three decimal places

4.7 SET/RESET Mode

rESn7d

PTRnEL

manual reset via the red SET/RESET key and electrical reset via the SET/RESET input

no rES

no reset (red SET/RESET key and SET/RESET input locked)

EL rES

only electrical reset via the SET/RESET input

P18orE

only manual reset via the red SET/RESET key

4.8 SET value

SEtPt

000000

The device will be set to the set point by pressing the red

999999

SET/RESET key or activating the SET/RESET input.

SET value -199999... 999999 (number of decimal places depends on the decimal point option)

For programming the decimal point see 4.6

4.9 End of programming

EndPro

no

The programming routine is repeated once more. The values set until now can be checked and modified.

YES

The programming routine will be left and all values set will be stored as new parameters.

Afterwards the device is ready for operation.

Tachometer/Frequency meter CODIX 522

(CODIX 524: Operating mode frequency meter)

1. Description

• 6 digit frequency meter
• Red LED display, character height 8 mm
• Display range from 0 to 999 999
- Leading zeros suppression.
- Programming via two setting keys on the front side
- During programming, the display guides the user with text prompts
- Value conversion and display in 1/s or 1/min
- Optional optocoupler output

2. Inputs

INP A

Dynamic count input.

3. Optocoupler output (optional)

Active at f=0. Can be used e.g. to activate a „No operation“ lamp.

4. Programming routine

The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine.

The first values stated correspond to the factor settings

4.1 Polarity of the inputs

Kübler CODIX 521 - Polarity of the inputs - 1

Kübler CODIX 521 - Polarity of the inputs - 2

npn: switching for 0 V

Kübler CODIX 521 - Polarity of the inputs - 3

pnp: switching for +U_B

4.2 Switching on the 30 Hz filter

Kübler CODIX 521 - Switching on the 30 Hz filter - 1

The filter provides input damping*

Kübler CODIX 521 - Switching on the 30 Hz filter - 2

30 Hz filter off ( f_max )

Kübler CODIX 521 - Switching on the 30 Hz filter - 3

30 Hzfilter on

4.3 Multiplying factor

Kübler CODIX 521 - Multiplying factor - 1

Kübler CODIX 521 - Multiplying factor - 2

It can be set from 00.0001 up to 99.9999.

The decimal point is set to 4 decimal places.

Kübler CODIX 521 - Multiplying factor - 3

„0“ is not accepted!

4.4 Dividing factor

Kübler CODIX 521 - Dividing factor - 1

Kübler CODIX 521 - Dividing factor - 2

It can be set from 00.0001 up to 99.9999.

The decimal point is set to 4 decimal places.

Kübler CODIX 521 - Dividing factor - 3

„0“ is not accepted!

4.5 Decimal point

Kübler CODIX 521 - Decimal point - 1

The decimal point defines the resolution in the selected measuring range 1/min or 1/sec

Kübler CODIX 521 - Decimal point - 2

0 no decimal place

0.0 one decimal place

0.00 two decimal places

Kübler CODIX 521 - Decimal point - 3

0.000 three decimal places

4.6 Display mode

Kübler CODIX 521 - Display mode - 1

Kübler CODIX 521 - Display mode - 2

Value conversion and display in 1/s

Kübler CODIX 521 - Display mode - 3

Value conversion and display in 1/min

4.7 Max. time to wait until „0“ is displayed

This parameter indicates, how long it takes, when measuring is active, until „0“ is displayed.

Kübler CODIX 521 - Max. time to wait until „0“ is displayed - 1

Kübler CODIX 521 - Max. time to wait until „0“ is displayed - 2

Max. time to wait 00.1 s (min. value)

Kübler CODIX 521 - Max. time to wait until „0“ is displayed - 3

Max. time to wait 99.9 s

4.8 End of programming

Kübler CODIX 521 - End of programming - 1

Kübler CODIX 521 - End of programming - 2

The programming routine is repeated once more. The values set until now can be checked and modified.

Kübler CODIX 521 - End of programming - 3

The programming routine will be left and all values set will be stored as new parameters. Afterwards the device is ready for operation.

Time meter CODIX 523

(CODIX 524: Operating mode time meter)

1. Description

  • 6 digit time meter with SET/RESET function
    • Red LED display, character height 8 mm
    • Display range from 0 to 999 999
  • Leading zeros suppression.
    • Operation indicator: the decimal point of the lowest digit blinks while the count is active.
  • Programming via two setting keys on the front side
  • During programming, the display guides the user with text prompts
    • Time meter operating modes
  • Counting while INP B is inactive (GAtE.Lo)
  • Counting while INP B is active (GatE.hi)
  • Count Start/Stop with INP B edge (Inb.Inb)
  • Count Start with INP A edge, count Stop with

INP B edge (InA.Inb)

  • Counting ranges h; min; s; h.min.s
  • Optional optocoupler output

2. Inputs

INP A

Start input (depending on the input mode chosen)

INP B

Start/Stop or gate input (depending on the input mode chosen)

SET/RESET input

Dynamic SET/RESET input. Linked in parallel to the red RESET key. Resets the counter to the predefined setting value.

3. Optocoupler output (optional)

On active counting the output alternates at a frequency of 1 Hz between active and inactive.

4. Programming routine

The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine.

The first values stated correspond to the factor settings

4.1 Polarity of the inputs

Kübler CODIX 521 - Polarity of the inputs - 1

Kübler CODIX 521 - Polarity of the inputs - 2

npn: switching for 0 V

Kübler CODIX 521 - Polarity of the inputs - 3

pnp: switching for +U_B

4.2 Switching on the 30 Hz filter

(INP A, INP B)

Kübler CODIX 521 - Switching on the 30 Hz filter - 1

Kübler CODIX 521 - Switching on the 30 Hz filter - 2

30 Hz filter off

Start/Stop inputs not damped

Kübler CODIX 521 - Switching on the 30 Hz filter - 3

30 Hz filter on

Start/Stop inputs damped for use with me cha nical switches.

4.3 Input mode

Kübler CODIX 521 - Input mode - 1

Kübler CODIX 521 - Input mode - 2

Start/Stop via Inp B. counting while Inp B (Gate) not active or open

Kübler CODIX 521 - Input mode - 3

Start/Stop via Inp B. counting while Inp B (Gate) active (High level with pnp; Low level with npn)

Kübler CODIX 521 - Input mode - 4

Count Start/Stop via INP B (LOW-HIGH edge with pnp; HIGH-LOW edge with npn). Every active edge changes the counter status.

Kübler CODIX 521 - Input mode - 5

Count start via INP A, stop via INP B. (LOW-HIGH edge with pnp; HIGH-LOW edge with npn)

4.4 Operating mode

Kübler CODIX 521 - Operating mode - 1

Kübler CODIX 521 - Operating mode - 2

Time unit: seconds (accuracy depending on position of the decimal point*)

Kübler CODIX 521 - Operating mode - 3

Time unit: minutes (accuracy depending on position of the decimal point*)

Kübler CODIX 521 - Operating mode - 4

Time unit: hours (accuracy depending on position of the decimal point*)

Kübler CODIX 521 - Operating mode - 5

Time units: Hours:Minutes:Seconds (decimal point setting is ignored)

*0, 0.1, 0.01, 0.001 means: time measurement in 0, 0.1, 0.01, 0.001 time units

4.5 Decimal point

Kübler CODIX 521 - Decimal point - 1

The decimal point defines the resolution of the program med time unit.

Kübler CODIX 521 - Decimal point - 2

0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)

Kübler CODIX 521 - Decimal point - 3

4.6 SET/RESET mode

Kübler CODIX 521 - SET/RESET mode - 1

Kübler CODIX 521 - SET/RESET mode - 2

manual reset via the red SET/RESET key and electrical reset via the SET/RESET input

Kübler CODIX 521 - SET/RESET mode - 3

no reset (red SET/RESET key and SET/RESET input locked)

EL rES

only electrical reset via the SET/RESET input

P180rE

only manual reset via the red SET/RESET key

4.8 SET value

SEPT

000000

The device will be set to the set point by pressing the red SET/RESET key or activating the SET/RESET input.

999999

SET value 0 ...999 999 or 99.59.59 (number of decimal places depends on the decimal point option)

4.8 End of programming

EndPro

oo

The programming routine is repeated once more. The values set until now can be checked and modified.

YES

The programming routine will be left and all values set will be stored as new parameters. Afterwards the device is ready for operation.

5. Technical data

Supply voltage

DC power supply: 10 ... 30 V DC/max. 55 mA with inverse-polarity protection

Display: 6 digits, red 7 segment LED display, height 8 mm

Data retention: EEPROM

Polarity of the inputs:

Programmable, npn or pnp for all inputs

Input resistance: appr. 5 kOhm

Count frequency CODIX 521:

Power supply DC:24 V12 V10 ...30 V
Input level:Standard5V
typ. Low Level:2,5 V2,0 V1,0 V
typ. High Level:22,0 V10 V4,0 V
Fmax*: kHzkHzkHz
CntDir60 208
UpDown25 158
Up.Up25 158
Quad125 158
Quad225 158
Quad415 158

Count frequency CODIX 522:

Frequency measurement

Accuracy <0.1 %

Measuring principle:

< 38 Hz: period measurement

38 Hz: gating time measurement gating time 26,3 ms

Power supply DC:24 V12 V10 ...30 V
Input level:Standard 5V
typ. Low Level:2,5 V2,0 V1,0 V
typ. High Level:22,0 V10 V4,0 V
Fmax*:kHz kHzkHz
Tacho6208

Counting ranges CODIX 523:

Seconds 0.001 s ... 999999 s Minutes 0.001 min ... 999999 min Hours 0.001 h ... 999999 h h.min.s 00 h 00 min 01 s ... 99 h 59 min 59 s Accuracy <50 ppm

Minimum pulse length for the Reset input:

5 ms

Input sensitivity:

Standard sensitivity:

Low: 0 ... 0,2 x UB [V DC]

High: 0,6 x UB ... 30 V DC

4 ... 30 V DC level: Low: 0 ... 2 V DC

High: 4 ... 30 V DC

Pulse shape: any*, Schmitt-Trigger inputs

Optocoupler output (optional):

NPN optocoupler with open collector and open emitter; max. switching performance: 30 V DC/10 mA

Ambient temperature:

-20 ... +65 °C at 10 ... 26 V DC

-20 ... +55 °C at >26 ... 30 V DC

Storage temperature:

-25 ... +70 °C

Altitude: to 2000 m

EMC:

Noise emission EN 55 011 Class B

Noise immunity EN 61 000-6-2

Housing:

For front panel mounting: 48 x 24 mm

acc. to DIN 43700, RAL7021, dark grey

Weight: appr. 50 g

Protection: IP 65 (front)

Cleaning: The front of the units is to

be cleaned only with a soft wet (water!) cloth.

6. Terminal assignment

without optocoupler

1 10 ... 30 V DC

20V GND

3 INP A

4 INP B (Codix 522: n.c.)

5 SET/RESET (Codix 522: n.c.)

with optocoupler

1 10 ... 30 V DC

20V GND

3 INP A

4 INP B (Codix 522: n.c.)

7. Delivery includes:

1 Digital display

1 Panel mounting clip

1 Bezel for screw mounting, panel cut out 50 x 25 mm

1 Bezel for clip mounting, panel cut out 50x25 mm

1 Seal

1 Multilingual operating instructions

8. Ordering code:

6.521.01X.3X0

6.522.01X.3X0

6.523.01X.3X0

6.524.01X.3X0

Kübler CODIX 521 - Ordering code: - 1

Input sensitivity

0 = Standard sensitivity

A = 4 ... 30 V DC level

Output

1 = Optocoupler output

2 = No output

6.521.01X.3X0
6.522.01X.3X0
6.523.01X.3X0
6.524.01X.3X0

Kübler CODIX 521 - Ordering code: - 2

text_image 50 25 32±0.1 R3

1 Counter sinking Af3, DIN 74

6.521.01X.3X0
6.522.01X.3X0
6.523.01X.3X0
6.524.01X.3X0