Kübler CODIX 521 - Measuring equipment

CODIX 521 - Measuring equipment Kübler - Free user manual and instructions

Find the device manual for free CODIX 521 Kübler in PDF.

📄 40 pages English EN 💬 AI Question
Notice Kübler CODIX 521 - page 9
View the manual : Français FR Deutsch DE English EN Español ES Italiano IT

User questions about CODIX 521 Kübler

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

L'email reste privé : il sert seulement à vous prévenir si quelqu'un répond à votre question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual CODIX 521 - Kübler and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CODIX 521 by Kübler.

USER MANUAL CODIX 521 Kübler

1.1 Safety instructions and warnings

Only use this display – in a way according to its intend- ed purpose – if its technical condition is perfect – adhering to the operating instructions and the general safety instructions.

1.2 General safety instructions

1. Before carrying out any installation or mainte-

nance work, make sure that the power supply of the digital display is switched off.

2. Only use this digital display in a way according

to its intended purpose: If its technical condition is perfect. Adhering to the operating instructions and the general safety instructions.

3. Adhere to country or user specific regulations.

4. The digital display is not intended for use in

areas with risks of explosion and in the branch- es excluded by the standard EN 61010 Part 1.

5. The digital display shall only operated if it has

been correctly mounted in a panel, in accor- dance with the chapter “Technical features”.

1.3 Use according to the intended purpose

The digital display may be used only as a panel- mounted device. Applications of this product may be found in industrial processes and con- trols, in manufacturing lines for the metal, wood, plastics, paper, glass, textile and other process- ing industries. Over-voltages at the terminals of the digital display must be kept within the limits in Category II. If the digital display is used to monitor machines or processes in which, in case of a failure of the device or an error made by the operator, there might be risks of damaging the machine or caus- ing accidents to the operators, it is your responsi- bility to take appropriate safety measures.

CODIX 521 Please note: Read first chapter 2 of CODIX 524 and go on on page 2. CODIX 522 Please note: Read first chapter 2 of CODIX 524 and go on on page 4. CODIX 523 Please note: Read first chapter 2 of CODIX 524 and go on on page 6. CODIX 524 CODIX 524 is a multipurpose device. Depending on the programmed basic function, the device operates like

2. Setting of the operating pa ra me ters

a. Press both front side keys keys and switch on the supply voltage or, if the supply voltage is already on, press both keys simultaneously during 5 s. b. The display shows c. After releasing the keys, the display shows c1. Hold the left key pressed and press the right key to leave the programming operation. c2. Press the right key to switch to d. Hold the left key pressed and press the right key to switch to the first parameter. e. After releasing the keys, the display alternates between the menu title and the current menu item setting. After pressing any key, only the menu item setting is displayed. f. Pressing the right key, the menu item setting will be switched to the next value. If figures are to be input (e.g. when setting the scaling fac- tor), select first the decade using the left key, and then set the value using the right key. g. Hold the left key pressed and press the right key to switch to the next menu item. h. The last menu title ”EndPro” allows, when selecting “Yes”, to exit the programming menu and to take over (store) the new values. If “no” is selected, the programming routine is repeat- ed, the latest values set remaining active. They can now be checked again or modified.

3. Programming routine

The first menu item is the selection of the basic operating mode, which determines the functions of the device. Operating mode pulse counter. Continued in point 4. of CODIX 521 on page 2 Operating mode frequency meter. Continued in point 4. of CODIX 522 on page 4 Operating mode time meter. Continued in point 4. of CODIX 523 on page 6 SET/RESET Dynamic SET/RESET input. Linked in parallel to the red SET/RESET key. Resets the counter to the predefined setting value.

4. Programming routine

The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine. The first values stated correspond to the factor settings Pulse counter/Po si ti on indicator CODIX 521 (CODIX 524: Operating mode pulse counter)

  • Red LED display, character height 8 mm
  • Display range from -199 999 to 999 999
  • Leading zeros suppression
  • Programming via two setting keys on the front side
  • During programming, the display guides the user with text prompts

npn: switching for 0 V pnp: switching for +U

4.2 Switching on the 30 Hz filter

It can be set from 00.0001 up to 99.9999. The decimal point is set to 4 decimal places. „0“ is not accepted!

only manual reset via the red SET/RESET key

The decimal point defines the way of displaying the count val- ues. It does not affect counting. 0 no decimal place

It can be set from 00.0001 up to 99.9999. The decimal point is set to 4 decimal places. „0“ is not accepted!

  • where bounce occurs, e.g. with contacts

The device will be set to the set point by pressing the red SET/RESET key or activating the SET/RESET input. SET value -199999... 999999 (number of decimal places depends on the decimal point option) For programming the decimal point see 4.6

4.9 End of programming

The programming routine is repeated once more. The val- ues set until now can be checked and modified. The programming routine wil be left and all values set will be stored as new parameters. Afterwards the device is ready for operation. manual reset via the red SET/RESET key and electrical reset via the SET/RESET input no reset (red SET/RESET key and SET/RESET input locked) only electrical reset via the SET/RESET input Tachometer/Frequency meter CODIX 522 (CODIX 524: Operating mode frequency meter)

  • Red LED display, character height 8 mm
  • Display range from 0 to 999 999
  • Leading zeros suppression.
  • Programming via two setting keys on the front side
  • During programming, the display guides the user with text prompts

4.3 Multitplying factor

It can be set from 00.0001 up to 99.9999. The decimal point is set to 4 decimal places. „0“ is not accepted!

4.2 Switching on the 30 Hz filter

30 Hzfilter on It can be set from 00.0001 up to 99.9999. The decimal point is set to 4 decimal places. „0“ is not accepted!

4.7 Max. time to wait until „0“ is displayed

This parameter indicates, how long it takes, when measuring is active, until „0“ is displayed. Max. time to wait 00.1 s (min. value) Max. time to wait 99.9 s

4.8 End of programming

The programming routine is repeated once more. The val- ues set until now can be checked and modified. The programming routine wil be left and all values set will be stored as new parameters. Afterwards the device is ready for operation.

  • where bounce occurs, e.g. with contacts

4.1 Polarity of the inputs

npn: switching for 0 V pnp: switching for +U

4. Programming routine

The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine. The first values stated correspond to the factor settings

The decimal point defines the resolution in the selected measuring range 1/min or 1/sec 0 no decimal place

  • Red LED display, character height 8 mm
  • Display range from 0 to 999 999
  • Leading zeros suppression.
  • Operation indicator: the decimal point of the lowest digit blinks while the count is active.
  • Programming via two setting keys on the front side
  • During programming, the display guides the user with text prompts
  • Time meter operating modes – Counting while INP B is inactive (GAtE.Lo) – Counting while INP B is active (GatE.hi) – Count Start/Stop with INP B edge (Inb.Inb) – Count Start with INP A edge, count Stop with5 english INP B edge (InA.Inb)

On active counting the output alternates at a fre- quency of 1 Hz between active and inactive.

4. Programming routine

The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine. The first values stated correspond to the factor settings

4.1 Polarity of the inputs

4.2 Switching on the 30 Hz filter

(INP A, INP B) 30 Hz filter off Start/Stop inputs not damped 30 Hz filter on Start/Stop inputs damped for use with me cha nical switches. npn: switching for 0 V pnp: switching for +U

Start/Stop via Inp B. counting while Inp B (Gate) active (High level with pnp; Low level with npn) Count Start/Stop via INP B (LOW-HIGH edge with pnp; HIGH-LOW edge with npn). Every active edge changes the counter status. Count start via INP A, stop via INP B. (LOW-HIGH edge with pnp; HIGH-LOW edge with npn)

Time unit: seconds (accuracy depending on position of the decimal point*) Time unit: minutes (accuracy depending on position of the decimal point*) Time unit: hours (accuracy depending on position of the decimal point*) Time units: Hours:Minutes:Sec- onds (decimal point setting is ignored)

manual reset via the red SET/RESET key and electrical reset via the SET/RESET input no reset (red SET/RESET key and SET/RESET input locked)6

only electrical reset via the SET/RESET input only manual reset via the red SET/RESET key

4.8 End of programming

The programming routine is repeated once more. The val- ues set until now can be checked and modified. The programming routine wil be left and all values set will be stored as new parameters. Afterwards the device is ready for operation.

The device will be set to the set point by pressing the red SET/RESET key or activating the SET/RESET input. SET value 0 ...999 999 or

99.59.59 (number of decimal

7. Delivery includes:

1 Digital display 1 Panel mounting clip 1 Bezel for screw mounting, panel cut out 50 x 25 mm 1 Bezel for clip mounting, panel cut out 50x25 mm 1 Seal 1 Multilingual operating instructions

english Housing: For front panel mounting: 48 x 24 mm acc. to DIN 43700, RAL7021, dark grey Weight: appr. 50 g Protection: IP 65 (front) Cleaning: The front of the units is to be cleaned only with a soft wet (water !) cloth.

6. Terminal assignment

  • at maximum frequency square wave pulses 1:1