ANT600 - RFID system IFM - Free user manual and instructions
Find the device manual for free ANT600 IFM in PDF.
User questions about ANT600 IFM
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your RFID system in PDF format for free! Find your manual ANT600 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ANT600 by IFM.
USER MANUAL ANT600 IFM
Operating instructions
RF-identification system
ANT513
Read/write head
Contents
1 Preliminary note 3
1.1 Symbols used 3
1.2 Warnings.... 3
1.3 Legal and copyright information 3
1.4 Open source information.... 3
2 Safety instructions.... 4
2.1 Safety symbols on the unit 4
2.2 Safety note on high-frequency electromagnetic radiation 4
2.3 Cybersecurity 5
3 Intended use.... 6
3.1 Application area 6
4 Items supplied.... 7
5 Function 8
5.1 ID tags 8
5.2 Device overview 8
6 Installation.... 9
6.1 Notes on the unit installation 9
6.2 Avoiding interference 9
6.3 Mechanical design 9
6.4 Alignment of the sensing face 10
6.5 Install device.... 10
6.6 Mounting distances.... 11
6.7 Positioning of the ID tag 11
7 Electrical connection.... 13
7.1 Wiring 13
8 Operating and display elements 15
9 Maintenance, repair and disposal 16
10 Approvals/standards 17
Glossary 18
1 Preliminary note
You will find instructions, technical data, approvals and further information using the QR code on the unit / packaging or at documentation.ifm.com.
1.1 Symbols used
√ Requirement
Instructions
Reaction, result
[...] Designation of keys, buttons or indications
→ Cross-reference

Important note
Non-compliance may result in malfunction or interference.

Information
Supplementary note
1.2 Warnings
Warnings indicate the possibility of personal injury and damage to property. This enables safe product handling. Warnings are graded as follows:

WARNING
Warning of serious personal injury
▷ If the warning is not observed, fatal and serious injuries are possible.

CAUTION
Warning of minor to moderate personal injury
▷ If the warning is not observed, minor to moderate injuries are possible.
ATTENTION
Warning of damage to property
▷ If the warning is not observed, damage to property is possible.
1.3 Legal and copyright information
© All rights reserved by ifm electronic gmbh. No part of these instructions may be reproduced and used without the consent of ifm electronic gmbh.
All product names, pictures, companies or other brands used on our pages are the property of the respective rights owners.
1.4 Open source information

For more open source information see: documentation.ifm.com.
2 Safety instructions
- The unit described is a subcomponent for integration into a system.
- The system architect is responsible for the safety of the system.
-
The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system. This documentation must contain all necessary information and safety instructions for the operator, the user and, if applicable, for any service personnel authorised by the architect of the system.
-
Read this document before setting up the product and keep it during the entire service life.
- The product must be suitable for the corresponding applications and environmental conditions without any restrictions.
- Only use the product for its intended purpose (→ Intended use).
- If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur.
- The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator.
- Installation, electrical connection, set-up, operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator.
- Protect units and cables against damage.
• Store the product in its original packaging.
2.1 Safety symbols on the unit
The following symbols are used on the device. Observe the instructions in order to avoid hazards:


• Electric supply must correspond to IEC 61010-1, chapter 9.4 - Limited-energy circuit.
• Device of protection class III. Only for operation in SELV/PELV circuits.
2.2 Safety note on high-frequency electromagnetic radiation
Under application-specific conditions, the risk for the user may differ depending on the installation situation and the device settings.
The system architect/operator is required to carry out a hazard analysis and to take appropriate measures for the protection of persons. In particular national regulations also have to be adhered to. Possible protective measures may include guaranteed minimum distances of a user, access controls and user training.

WARNING
Operation of this device can cause radio interference in residential areas.
▷ The device emits high-frequency electromagnetic waves that may interfere with the operation of electronic devices in the vicinity, including pacemakers, hearing aids and defibrillators.
▶ Due to human exposure regulations, a minimum distance of 20 cm must be maintained between the device and persons.
▶ If you have a pacemaker or other implanted medical product, do not use the device without first consulting your doctor or the manufacturer of your medical product. Keep a safe distance between the device and your medical devices and refrain from further use of the device if you observe permanent impairment of your medical product.
2.3 Cybersecurity
Installation
The device is suitable for operation in a secure environment according to IEC 62443-1-1.
The device was designed for operation behind a firewall.
▶ Carry out a risk assessment of the system according to IEC 62443-1-1.
▶ Take measures to ensure physical security.
Operation
▶ Observe the security functions described in the product documentation and the recommendations for their use.
Maintenance
▶ Regularly check whether software updates are available for the device.
- ▶ Back up system configuration and system data in accordance with your company's change management processes.
Decommissioning
▶ Ensure that no sensitive information can fall into unauthorised hands.
▶ Always reset the system settings to the factory settings before decommissioning the device.
3 Intended use
The read/write head reads and writes ID tags without contact. For use, the read/write head must be connected to the DTE10x evaluation unit.
The data is converted into digitally coded values and provided to the evaluation unit.
3.1 Application area
The device safety is rated for use under the following operating conditions:
- Protection class 3 (SELV/PELV) and supply of the device to limited energy according to IEC 61010-1, chapter 9.4. Isolate the external circuits as required by figure 102 in IEC 61010-2-201.
- For indoor use.
• Altitudes up to 2000 m. - Relative air humidity up to max. 80 %, non condensing.
- Pollution degree 2.
4 Items supplied
- Read/write head

The device is supplied without installation and connection accessories.
Available accessories: www.ifm.com.
The optimum function is not ensured when using components from other manufacturers.
5 Function
5.1 ID tags
The ID tags are passively operated without a battery. The energy required for operation is provided by the read/write head.
The energy is provided via an inductive coupling. The integrated antenna coil in the read/write head generates a magnetic field which partly penetrates the antenna coil of the ID tag. A voltage is generated by induction that supplies the data carrier with energy.
The device supports ID tags according to ISO 15693.
5.2 Device overview
![]() | Article number: | ANT513 |
| Function: | Read/write head | |
| Type designation: | DTRHF MCRWIDUS03 | |
| Type: | rectangular |
6 Installation
6.1 Notes on the unit installation
When mounting several RFID units adhere to the minimum distances between the systems.
Flush mounting of a read/write head in metal reduces the read/write distance.
Device performance can be affected if positioned in the immediate vicinity of powerful HF emission sources such as welding transformers or converters.
6.2 Avoiding interference
The device generates a modulated electrical field with a frequency of 13.56 MHz.
Avoid interference with data communication:
▶ Do not operate any devices in the vicinity that use the same frequency band.
▷ Such devices are for example frequency converters and switched-mode power supplies.
If there are other devices in the same frequency band in the vicinity:
▶ The mounting distances between the devices should be as large as possible.
▶ Use the devices in alternating operation.
▶ Switch the HF field of the device on/off.
6.3 Mechanical design
On delivery the sensing face is facing the front.

Fig. 1: Factory setting

Fig. 2: Antenna head separated from the fixing element
1: Sensing face
2: Adjustable antenna head
3: fixing element
6.4 Alignment of the sensing face
![]() | ► Loosen the screw. |
![]() | ► Remove the antenna head from the fixing element and turn it. |
![]() | ► Attach the fixing element to the antenna head. |
![]() | ► Tighten the screw. |
6.5 Install device
▶ Fix the device with 2 M5 screws and nuts.

Fig. 3: Non-flush mounting

Fig. 4: Flush mounting
6.6 Mounting distances

Fig. 5: Minimum lateral distance

Fig. 6: Minimum frontal distance
| Operating mode | Distance side (A) | Distance front (B) |
| For reading and writing | ≥ 300 mm | ≥ 250 mm |
6.7 Positioning of the ID tag
For installation in or on metal use the ID tags provided for this purpose.
▶ Align the ID tag on the central axis of the antenna of the device.
The distance "D" is indicated in the data sheet.
▷ All indications apply to static read/write operations.

Fig. 7: Position the ID tag
7 Electrical connection
The device must be connected by a qualified electrician.
▶ Disconnect power before connecting the device.

Protection class III device (IEC 61010-2-201 chap. 6.5.2.101.4).
The electrical supply must meet the following requirements:
• Use of a power supply with limited output voltage (ES1 according to IEC 62368-1)
• Use of a power supply with limited output power (PS2 according to IEC 62368-1)
• Supply only via SELV/PELV circuits (IEC 61010-2-201 chap. 3.111)
• Maximum supply voltage during operation: 35 V DC
• Maximum supply voltage in the event of a single fault: 60 V DC
- The permitted operating voltage of the device must not be exceeded (see data sheet).
The separation of external circuits must comply with IEC 61010-2-201, Figure 102.

WARNING
Unsuitable power supply
▷ Electric shock may cause serious injury or death.
▶ Use a SELV/PELV power supply within the specified voltage range.
▶ Use energy-limited circuits for the electrical supply (IEC 61010-1 chap. 9.4). The energy of the circuit can be limited at an operating voltage of 24 V by an overcurrent protection device. The overcurrent protection device must switch off a current of 8.3 A in maximum 120 s. Observe the specific tripping characteristic. Possible overcurrent protection devices:
- Fuse or
• Non-adjustable and non-self-reclosing electromechanical device.
▶ Separate the circuit from other, non-energy-limited circuits by at least basic insulation.
ATTENTION
No suitable energy limitation of the circuit
▷ Fire hazard in case of a malfunction.
▶ Use energy-limited circuit according to IEC 61010-1 chap. 9.4.
ATTENTION
Use an additional protection against surge voltages according to IEC 61000-4-5 if the connection cable is longer than 30 m.
7.1 Wiring
▶ Connect the unit to a DTE10x evaluation unit via the M12 connector.
▷ Voltage is supplied via the evaluation unit.
| Pin assignment | Wiring |
![]() | ![]() |

Information on available sockets see: www.ifm.com.
Cables with the following characteristics are suitable for the connection:
| Length | Ohmic resistance (feed + return line) | Effective cable capacity |
| < 20 m | max. 3 Ω | max. 3 nF |
8 Operating and display elements

Fig. 8: Light indicators
1: LED green: operating voltage
2: LED yellow: ID Tag
| LED | State | Description |
| Green | On | Operating voltage OK |
| Off | Operating voltage missing | |
| Flashing slowly | Deactivated | |
| Yellow | On (permanently) | ID tag detected |
| On (pulse) | ID Tag read/written successfully | |
| Flashing quickly | Error when reading/writing on ID tag | |
| Off | No ID Tag in the RF field Faulty ID Tag in the RF field Invalid ID Tag in the RF field | |
| Green and yellow | Flashing alternately | Error in communication or device fault |
9 Maintenance, repair and disposal
The unit is maintenance-free.
▶ Contact ifm in case of malfunction.
▶ Do not open the housing as the unit does not contain any components which can be maintained by the user. The unit must only be repaired by the manufacturer.
▶ Clean the device using a dry cloth.
▶ Dispose of the unit in accordance with the national environmental regulations.
10 Approvals/standards
For approvals and standards, the following information is available:
• Test standards and regulations: documentation.ifm.com
• EU declaration of conformity and approvals: documentation.ifm.com
• Notes relevant for approval: Package insert of the device and documentation.ifm.com
Glossary
ID tag
An ID tag is used to identify objects. A read/write device is used to read the ID tag via a high-frequency radio signal. An ID tag consists of an antenna, an analogue circuit for receiving and transmitting (transceiver), a digital circuit and a non-volatile memory.