Overmax AD05 - Breathalyzer

AD05 - Breathalyzer Overmax - Free user manual and instructions

Find the device manual for free AD05 Overmax in PDF.

📄 56 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Overmax AD05 - page 10
Pick your language and provide your email: we'll send you a specifically translated version.
Product typePersonal alcohol tester
BrandOvermax
ModelAD05
SensorElectrochemical
DisplayLCD
Measurement unitPer mille (‰) (switchable)
Power supply2 AAA alkaline batteries 1.5V
Measurement range0.00 ‰ to >2.00 ‰ (display "H")
Operating temperature10 °C to 40 °C
Optimal temperature20 °C to 26 °C
Test memoryLast 16 results
Recommended calibrationEvery 12 months or 300 tests
Auto shut-off30 seconds
Test counterYes (displayable, resettable)
Waiting time before test15-20 minutes after consumption
Time between tests3-5 minutes (low alcohol), 10 minutes (high alcohol)
MouthpiecesSingle use, change each test
Low battery indicatorDisplay "Lo"
Error messagesH (high level), Flo (insufficient breath), Snr (sensor not ready), rPt (test failed), Out (temperature)
SafetyDo not use to decide to drive
WarningIndicative result only

Frequently Asked Questions - AD05 Overmax

How to use the AD05 alcohol tester?
Turn on the device by pressing the On/Off button for 2 seconds. Wait for the countdown. Insert a new mouthpiece. Blow continuously until the double beep. The result is displayed in ‰. To turn off, press and hold On/Off.
How long to wait after drinking before testing?
It is recommended to wait 15 to 20 minutes after the last consumption of alcohol or tobacco, and to rinse the mouth with water.
What does the display "H" mean?
"H" indicates a high alcohol concentration exceeding 2.00 ‰ BAC / 0.200 %BAC / 1.00 mg/L.
How to change the display unit (‰, %, mg/L)?
While the device is on, press the option selection button (3) to toggle between display formats.
How to view test history?
Press the option selection button (3) to display the last 16 tests. Use the On/Off button to exit.
When should the device be calibrated?
It is recommended to calibrate the device every 12 months or every 300 tests. Contact customer service for calibration.
What to do if the device displays "Lo"?
"Lo" means low batteries. Replace the batteries with new AAA alkaline batteries.
Can I use the device to decide to drive?
No, the device is indicative only. The manufacturer disclaims all legal responsibility. Do not make driving decisions based on this test.
Why does my test show "Flo"?
"Flo" indicates insufficient or uneven breath concentration. Retake the test by blowing continuously and steadily.
How to replace the batteries?
Slide open the battery compartment cover. Install two AAA 1.5V alkaline batteries respecting polarity. Close the cover.

User questions about AD05 Overmax

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Breathalyzer in PDF format for free! Find your manual AD05 - Overmax and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AD05 by Overmax.

USER MANUAL AD05 Overmax

EN: The product complies with requirements of EU directives.

Pursuant to the Directive 2012/19/EU, this product is subject to selective collection. The product must not be disposed of along with domestic waste as it may pose a threat to the environment and human health. The worn-out product must be handed over to the electrics and electronics recycling center.

natural_image Diagram of a device with labeled parts, showing a rectangular panel and two labeled points (3 and 4) without any text or symbols.

Wprowadzenie

Drogi Kliencie!

Thank you for placing trust in us and choosing Overmax.

Thanks to high-quality materials and modern solutions, we provide you with a product perfect for everyday use. We are convinced that the product will satisfy your requirements as it has been manufactured with utmost care. Before you use the product, please read this manual carefully.

Should you have any remarks or questions concerning the product, please do not hesitate to contact us:pomoctechniczna@overmax.pl

Read the manual before use.

Personal breathalyzer AD-05 is a mobile device for testing alcohol content from a breath sample. The product has been equipped with an electrochemical sensor which estimates blood alcohol content in a few seconds!

Description:

  1. Mouthpiece opening
  2. LCD display
  3. Options select key
  4. On/off key

1. USE

NOTE!

  • Before you use the device, wait for at least 15 minutes after drinking alcohol or smoking cigarettes.
  • Before use, rinse your mouth with water.
  • It is necessary that you wait for 15 minutes. If you fail to follow this rule, the test results may not be reliable. The readout value „will rise” fast and then gradually „drop”. This results from stubborn alcohol remains in the oral cavity which distort values measured.

  • It is advisable to take a breath test at the room temperature in order to assure optimal accuracy.

  • It is also advisable to store the device at the room temperature (when the device is not used for a long time) to keep the sensor in a proper condition.
  • Do not use and do not store the device at extreme temperatures and in highly humid conditions.
  • To use the device, gently press and slip off the battery cover. Put two AAA 1.5V alkaline batteries in and close the battery cover. Using non-alkaline batteries may result in imprecise results

HOW TO USE:

  • Put the mouthpiece in the opening on the left side of the device. It is recommended to change the mouthpiece after every use.
  • Switching ON: press on/off key (4) and hold for 2 seconds to switch the device on. The device initiates the sensor heating procedure. The second hand starts counting. _20

Alcohol content from breath sample is now taken:

  • Preparing: when counting is over, you will see a flashing „rdy” (ready) which means the device is now ready to collect the sample of breath.
    **UThe device will wait for 8 seconds for the sample of breath. If it is not detected, the device will show zero - 0.00.
  • Blowing: blow continuously into the mouthpiece. A long „beep” sound suggests that the device collects the air. Keep on blowing until you can hear a loud sound in the form of a „double beep”. At this point you have to stop blowing in.
  • The device starts analyzing the breath and shows " (calculating).
  • Wait for a while to see the result in ‰ on the display.
  • Switching off : press on/off key (4) and hold for 2 seconds to switch the device off.

IMPORTANT!

  1. The test result will be set and displayed in per mil ( % ). If you wish to change the alcohol level display format, press the options select key (3) to switch into the desired format.
  2. The device may emit a long sound when taking the breath sample and give 0.00. This happens because it is possible to measure a very low content of other substance in your breath (e.g. bad smell). By default, if the device detects no alcohol content, it will emit a long sound and the result will be 0.00.
  3. In some cases the device may display “☐☐☐”. It happens when the conditions of the test are too cold or too hot. Before you retake the test, wait for a dozen minutes until the sensor inside the device reaches the room temperature.
  4. The device will switch off automatically after 30 seconds. You can also switch the breathalyzer off by pressing on/off key (4) and holding for 3 seconds.
  • It is advisable to wait for a few minutes (3-5 minutes) between every breath test (for low alcohol level).
  • With regard to high alcohol level, please wait for at least 10 minutes before you retake the test. This way you let stubborn alcohol remains disappear from the sensor. This is also how you can help keep the proper condition of the sensor and maintain test result reliability.

2. TEST MEMORY MODE:

To check the total number of breathalyzer tests, please follow the description below:

- When counting, press on/off key (4) to display the total number of tests performed. This number helps you decide about time for calibration. For more details, see „Calibration”.

  • If you want to reset this counter, long-press the options select key (3) until you can see the counter shows zero.
  • Displaying last 16 tests:

Press the options select key (3) to display the history of tests (they will be displayed on the screen, marked with „1” serial number, and then with relevant result)

- To leave the test memory mode, press on/off key (4) again.

EN

3. SYSTEM MESSAGES

Message Meaning of the message
Overmax AD05 - SYSTEM MESSAGES - 1The device has detected high alcohol level (above 2,00‰ BAC / 0.200%BAC /1.00 mg/L)
Insufficient or uneven breath sample detected. Please retake the test (see: „how to use)
Overmax AD05 - SYSTEM MESSAGES - 2The sensor of the device is not ready. This happens when high alcohol or dirt from the last test remains on the sensor. This being the case, switch the device off and wait for a couple of minutes before another test.
Overmax AD05 - SYSTEM MESSAGES - 3The device was unable to finish the test. Retake the test. Other cause is high ambient temperature. In such case please retake the test (see: „how to use”)
Overmax AD05 - SYSTEM MESSAGES - 4Low battery. Use new AAA alkaline batteries
[Out]TThe temperature of the test was too low or too high. Restore room temperature for the device. Before another test, wait for a couple of minutes until the device sensor reaches the room temperature.

4. SAFETY PRECAUTIONS

  • Wait for at least 15-20 minutes if you have drunk alcohol or smoked cigarettes before you take the test. Remember to rinse your mouth with water.
  • To obtain precise results, it is advisable to calibrate the device every 12 months or 300 tests.
  • The devices operates at the temperature of 10 – 40°C, with optimal precision for tests at room temperature (i.e. ca. 20 – 26°C).

EN

  • If the test result is lower than 0,10‰ or 0,10 % BAC or 0,050 mg / L, it is natural when you didn't drink any alcohol. It happens because in some cases it is possible to detect other substance than alcohol from the breath sample.
  • Do not use the device if you wish to specify and decide about driving vehicles. The result displayed is for information purposes only. The manufacturer and retailer waive any legal liability for measured/estimated test value.

5. MAINTENANCE

To keep the device in a good condition, it is important that you use the device at least once a month.

6. CALIBRATION

  • Precision of alcohol level testers may change after 6-12 months of use, depending on the number of tests done and working conditions.
  • If the device shows inconsistent test results, fails to show any test results or displays extremely high or low results, the product must be calibrated.
  • To calibrate it, contact the service center.

The pictures are for reference only. The real design of the products may differ from the pictures presented.

Einführung

Einführung!

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Overmax

Model : AD05

Category : Breathalyzer