USER MANUAL AD06 Overmax

EN: The product complies with requirements of EU directives.

Pursuant to the Directive 2012/19/EU, this product is subject to selective collection. The product must not be disposed of along with domestic waste as it may pose a threat to the environment and human health. The worn-out product must be handed over to the electrics and electronics recycling center.

PL

OPTYMALNA TEMPERATURA DO POMIARU

Thank you for placing trust in us and choosing Overmax.

Thanks to high-quality materials and modern solutions, we provide you with a product perfect for everyday use. We are convinced that the product will satisfy your requirements as it has been manufactured with utmost care. Before you use the product, please read this manual carefully.

Should you have any remarks or questions concerning the product, please do not hesitate to contact us:

A. mouthpiece inlet
B. display
C. start test / see test results
D. see test results
E. switch on and off / show number of tests done / show last result

BATTERY

The breathalyzer needs two AA batteries to operate. To replace the batteries, press the cover and slip if off the battery compartment (at the back of the device). Take old batteries out and put new batteries in; pay special attention to polarity. Close the battery compartment.

15 MINUTES BEFORE MEASUREMENT

Before you start the test, please wait for at least 15 minutes after drinking alcohol. Rinse your mouth with water before you initiate the test.

Do not drink alcohol or smoke cigarettes for these fifteen minutes. If you do so or if you forget to rinse your mouth, the test result may be false. This results from existence of alcohol remains. If you ignore the aforesaid guidelines, the test result may be incorrect and you can also damage the sensor!

Overmax AD06 - MINUTES BEFORE MEASUREMENT - 1

Overmax AD06 - MINUTES BEFORE MEASUREMENT - 2

Overmax AD06 - MINUTES BEFORE MEASUREMENT - 3

OPTIMAL TEST TEMPERATURE

It is advisable to conduct tests and store the device at the room temperature. Do not store the product if temperatures are extreme and if conditions are highly humid (for example in the car in winter or summer).

EN

HOW TO TAKE A TEST

  1. Put the mouthpiece in a relevant inlet (upper left corner of the device, marked in fig. 2).

Note – if a test is done without the mouthpiece, the results may be inaccurate. It is advisable to replace the mouthpiece before every measurement.

  1. Press and hold the on key for 2 seconds. After switching on, the device will start heating sensors up. The entire procedure takes up to 20 seconds (the counter will be showed on the display, see: fig. 3).

Next choose one of two modes: automatic or manual.

Automatic mode – easier test mode. AD-06 monitors the user's breath and then decides when to take the sample on its own (end of air exhalation).

Manual mode - usually used when the automatic mode is unfeasible.

AUTOMATIC MODE

A. When you can see „rdy” (abbreviated from „ready”, see: fig. 4) and the device emits a short sound, take a deep breath and blow into the mouthpiece which was previously inserted into the device. Make sure you exhale long and evenly (not too fast, at regular pace).

B. The device will emit a sound and show a message on the display (see: fig. 5). This will mean that you have exhaled properly. Keep on blowing until you can hear a double „click”. At this moment stop blowing in, the device has collected the sample of breath.
C. The breathalyzer will start analyzing the data (fig. 5). Wait for results.

EN

MANUAL MODE

A. When you can see „rdy” (abbreviated from „ready”, see: fig. 4) and the device emits a short sound, press the left key (C) to activate the manual mode.
B. The display will show a message (fig. 5) and emit a continuous sound.
C. Take a deep breath and blow into the mouthpiece continually. Keep on blowing until you can hear a double „click”. At this moment stop blowing in.
D. The device starts analyzing the breath and shows”[---, (calculating). Wait for a while to see alcohol level result.
E. The alcohol level result will be displayed in any format (‰, %, mg / l) according to the BAC display format specific to the given country. If you wish to change this format, press the left key (C).

IMPORTANT!

  • In some cases the device may automatically prolong the sound before blowing in and show the result 0.00. This happens because a very low content of other substance in the sensor may be measured if you do not use the product for a long time. This being the case, retake the test.
  • In some cases the device may show the result. This happens when the temperature of the test is too low or too high. Before you retake the test, you may be required to wait for a couple of minutes until the sensor inside the device reaches the room temperature.

- The alcohol level result will be presented on the display for 30 seconds. The device will switch off later automatically. You can also shut it down at any time by pressing the on/off key (E) and holding for 3 seconds.

After you finish the first test and before you start another, you are advised to wait for at least a couple of minutes (5-10 minutes at best) to prevent accumulation of alcohol remains on the sensor and keep the proper condition of the sensor.

TEST MEMORY MODE:

To check the total number of breathalyzer tests, please follow the steps below:

  • When counting, press on/off key (E) to display the total number of tests done. This number helps you decide when to perform calibration. For more details, see „Calibration”.
  • If you want to reset this counter, long-press the left key (C) until you can see the zero on the counter.
  • It is advisable to re-calibrate the device once a year or after 300 tests, depending on what happens earlier.

DISPLAYING LAST 50 TESTS:

  • Press the on/off key (E) to display history of tests done (they will be showed on the screen, marked with serial number „1“ and then with relevant result)
  • Press the right key (D) to display previous results.
    • To leave the test memory mode, press the on/off key (E) again.

SYSTEM MESSAGES

Message Meaning of the message
Overmax AD06 - DISPLAYING LAST 50 TESTS: - 1The device has detected high alcohol level (above 4.00‰ BAC / 0.400%BAC /2.00 mg/L).
Overmax AD06 - DISPLAYING LAST 50 TESTS: - 2Insufficient or uneven breath detected. Retake the test.

EN

Overmax AD06 - EN - 1The sensor of the device is not ready. It happens when there is high alcohol or dirt remains from the last test on the sensor. This being the case, switch the device off and wait for a couple of minutes before you take another test.
Overmax AD06 - EN - 2The device was unable to finish the test. Retake it.
Overmax AD06 - EN - 3The temperature of the test is too low or too high. Restore room temperature for the device. Before you take another test, wait for a couple of minutes until the sensor inside the device reaches the room temperature.
Overmax AD06 - EN - 4Low battery. Use new AA alkaline batteries.

SAFETY PRECAUTIONS

  • Wait for at least 15-20 minutes after drinking alcohol or smoking cigarette and before you start the test. Remember to rinse your mouth with water.
  • For more precise results, it is advisable to calibrate the device every 12 months or 300 tests.
  • The device operates at the temperature of 10 – 40°C, with optimal precision for tests at room temperature (i.e. ca. 20 – 26°C).
  • If the test result is lower than 0,10 ‰ or 0,10 % BAC or 0,050 mg / L, it is natural if you did not drink alcohol before. It happens because in some cases it is possible to measure other substance than alcohol.
  • Do not use the device to specify and decide about driving vehicles. The alcohol level result is for information purposes only. The manufacturer and retailer waive any legal liability for the estimated/measured test value.

MAINTENANCE

To keep the device in a good condition, it is advisable to use the device at least once a month.

CALIBRATION

  • The precision of alcohol level testers may change after 6-12 months of use, depending on the number of tests and working conditions.
  • If the device shows inconsistent test results, fails to show any results or displays very high or very low results, it must be calibrated.
  • To perform calibration, please contact the service center.

EN

The pictures are for reference only. The real design of the products may differ from the pictures presented.

Einführung

OPTIMALE TEMPERATUR ZUR MESSUNG

TEMPÉRATURE OPTIMALE POUR LA MESURE

OPTIMALE TEMPERATUUR OM TE TESTEN

OPTIMALI MATAVIMO TEMPERATÜRA

OPTIMALNA TEMPERATURA ZA MJERENJE

natural_image Solid yellow horizontal bar with no text or symbols

Overmax AD06 - OPTIMALNA TEMPERATURA ZA MJERENJE - 1

natural_image Solid yellow horizontal bar with no text or symbols

OVERMAX

You•unlimited

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Overmax

Model : AD06

Category : Breathalyzer