GS 751 3in1 - Water pump Güde - Free user manual and instructions
Find the device manual for free GS 751 3in1 Güde in PDF.
User questions about GS 751 3in1 Güde
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Water pump in PDF format for free! Find your manual GS 751 3in1 - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GS 751 3in1 by Güde.
USER MANUAL GS 751 3in1 Güde
ENGLISH Please read the instructions carefully before starting the machine.
Combined submersible pump GS 751 3in1
Art.No 94643

Service connection. 230 V/50 Hz

Motor output P1. 750 W

Max.immersion. 7 m

Max. head of delivery 8,5 m

Max. delivered quantity 15900 l/h

Max.suction. 30 mm

Max. Water temperature.. 35^

Hose connection. 1 14 "IG
IPX8
Degree of protection. IP X8

Weight. 5,15 kg
The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the existing water-supply network as a pressure-boosting device.


Read and understand the operating instructions before using the appliance. Abide by all the safety
measures stated in the service manual. Act responsibly toward third parties.
In case of any doubts about connection and operation refer please to our customer center
Specified Conditions Of Use
The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm and agriculture and only for water.
Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.
Power tool description
1 | Floating switch
2 Suction foot
3 Pump connection
4 Pump connection angle
5 | Connecting branch for the hose fitted
6 | Handle
7 | Power supply cable
8 | Foot
9 | Foot
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before using the appliance.
Qualification : Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.
Minimum age: Persons over 18 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.
Training : Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary.
The operator is responsible for accidents or risks to third parties.
Observe to keep out of dangerous zone
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used.
If you seek help, state the following pieces of information:

Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.

Protect against humidity

This side up
- Accident site
- Accident type
- Number of injured persons
- Injury type(s)
Symbols

Read the Operating Instructions

Before carrying out any work on the machine, disconnect the plug from the socket.

Cable pulling / transport prohibited

Staying in the transportation medium prohibited

To be kept/stored in dry conditions

Not frost-resistant

Warning against dangerous electric voltage

Warning against automatic starting

Accessories - not included in the supply; recommended equipment specified in the list of accessories

Plunge the pump into water at an angle.

Manual adjustment
Safety Instructions

WARNING! Electric shock!
There is a risk of an injury caused by electric shock!
Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA ). Please ask your electrician.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.
Translated with www.DeepL.com/Translator (free version)Children should be supervised to ensure that they do not play with the device. Always keep children and unauthorised persons out of reach of the appliance.
Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA ). Please ask your electrician.
Before putting into operation, a qualified electrician must check whether electric safety measures required are in place. Any national regulations in this regard must be complied with.
Electric connection to a socket.
It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.
Check the voltage. Technical data given on the type label must correspond with electric network voltage.
Only use splash proof extension cables approved for outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!
Check the cable and/or socket for damages before the appliance putting into operation.
To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not execute any repair yourself under any circumstances.
Protect the feeder cable from excessive temperatures, oil and sharp edges.
Unplug the device prior to submersion, upon termination of operation, in the course of defect removal and prior to performing maintenance procedures.
If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).
The pump must not in any case run without fillings.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
The temperature of the drained liquid must not exceed +35^
If the lubricant escapes the fluid could become contaminated.
If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.
The user is responsible to third parties if pump (dump- ping stations, etc.) is used.
operation
The pump must not in any case run without fillings.
Guarantee
Warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device.
The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.
GüDE cannot be held responsible for damages incurred in consequence of unqualified installation or unskilled handling of the pump.
The device has to be checked on a regular basis to ensure perfect functioning.
Let us refer to the fact we do not assume any responsibility - according to standards in force - for damage eventually caused by our appliances in the below-mentioned cases
- Unprofessional repairs executed by unauthorised service centres;
- Use in conflict with the designed purpose, or failure to observe the use as designed;
- Pump overload with a continuous run;
- Damage as a result of icing or any other fault caused by climatic influences;
Identical regulations apply for accessory parts.
To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
Service
Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guide.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference
Serial No.:
Art. No:
Year of production:
Maintenance
Before carrying out any work on the machine, disconnect the plug from the socket.
Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.
The machine must not be used under any circumstances if the machine or the safety devices are damaged.
In case of a failure of the pump, a repair can only be executed by the GÜDE service centre. Original spare parts to be used only.
To ensure long service life of the pump seal we recommend rinsing the pump with clean water in regular intervals.
At winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with appropriate oil (for example, with vegetable oil).
Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.
Disposal
Do not dispose electric appliances as household refuse. According to the European Directive No. 2012/19/EU on waste electrical and electronic equipment and based on including this Directive in the national law, separate collection of worn electrical equipment must be provided and such equipment must be recycled in an environment-friendly manner. Recycling alternative of recovery Alternatively to sending equipment back, the electrical equipment owner is obliged to cooperate in the professional evaluation. An old appliance may also be left to a collection centre that will provide disposal in accordance with the national law regarding circulation management and waste. This does not apply to parts of accessories and aids connected to old appliances and not containing electrical components.
Inspection and maintenance plan
Time interval Description Any other details
As needed Cleaning and rinsing. Check the float switch function.
Failures - causes - removal
| Failures Causes Removal | ||
| Engine does not start No | power supply. Blocked pump wheel Floating switch in shutdown position | Check the voltage Visually inspect the pump wheel for foreign objects Check the water level |
| Pump does not suck Pump | without water Water level too low Hose connection to greatly reduced Blocked pump wheel | Let the air bubbles release → 5 Switch the pump off, water level must go up. Select as large hose connection Replace hose connection Remove the obstruction |
| Thermal detector swit-ching the pump off → 7 | Plugged strainer Water temperature too high Pump running continuously at maximum pressure. | Clean the strainer and let the pump cool down Reduce the water temperature Make more breaks |
| Insufficient amount of water pumped | Dirty strainer Water level quickly drops down Maximum head of delivery exceeded Broken piping | Clean the strainer Ensure sufficient inflow Check the transport line Check the transport line |
\section*{Caracteristiques Techniques}
Pompe submersible combinée GS 751 3in1
Alimentation. 230 V/50 Hz

Aansluiting. 230 V/50 Hz

Motorvermogen P1. 750 W

Max.dompeldiepte. 7m

Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below mentioned appliances correspond - at the type of construction being launched - to appropriate basic safety and hygienic requirements of EC Directives.
In case of any change to the appliance not discussed with us the Declaration expires.
Notified Body Name: No: Adress
Type Ex.Cert.-No.:
97/68/EC_&2016/1628/EU
Emission No.:
2000/14/EC_2005/88/EC
EasyManual