Güde GS 750.1 INOX - Water pump

GS 750.1 INOX - Water pump Güde - Free user manual and instructions

Find the device manual for free GS 750.1 INOX Güde in PDF.

📄 56 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Güde GS 750.1 INOX - page 18
Pick your language and provide your email: we'll send you a specifically translated version.
Product typeSubmersible water pump
BrandGüde
ModelGS 750.1 INOX
Order number94679
Rated voltage230 V
Protection degreeIP X8
Max flow rate15,000 l/h
Max delivery head8 m
Max submersion depth7 m
Max particle size (grain size)35 mm
Max water temperature35 °C
Connection1 1/2" IG (internal thread)
Cable length10 m
Weight6.5 kg
Housing materialStainless steel (INOX)
Float switchYes, integrated
Overload protectionYes, thermal
Permitted usesDrainage, transfer, emptying containers
Warranty (consumer)24 months
Recommended maintenanceRinse with clean water after use
Winter storageEmpty and store frost-free
Residual-current device requiredYes, max 30 mA

Frequently Asked Questions - GS 750.1 INOX Güde

Can I use the pump for drinking water?
No, use for drinking water is strictly prohibited. The pump is designed only for clear or slightly dirty water (max 35 mm grain size).
What is the maximum submersion depth?
The maximum submersion depth is 7 meters. Do not exceed this value to avoid damaging the pump.
How do I install a residual-current device?
The pump requires a residual-current device (RCD) with a maximum fault current of 30 mA. Call a qualified electrician if necessary.
What to do if the pump does not start?
First check the power supply. Make sure the pump impeller is not blocked by foreign objects. Also check the position of the float switch (sufficient water level).
Can I use the pump continuously?
No, the pump is not designed for long-term operation (e.g., circulation pump). Use a contact timer and observe rest periods. Continuous operation reduces the lifespan.
How to maintain the pump?
Rinse the pump regularly with clean water to prevent clogging. Before winter, empty it completely to avoid frost damage. Seal adhesion can be improved with a little vegetable oil.
What does the thermal switch that cuts off the pump mean?
The thermal switch protects the pump from overload. If the pump stops, let it cool down. Possible causes are a clogged suction strainer, water temperature too high, or continuous operation at max pressure.
What is the warranty for this pump?
The warranty is 24 months for the end consumer (12 months in industrial use). It covers material and manufacturing defects. Keep the purchase receipt.
Can I fully submerge the pump?
Yes, the pump is designed to be submerged up to 7 m. Make sure the power cable is not submerged at the plug. The plug must stay out of water and protected from moisture.
What to do in case of breakdown?
Consult the troubleshooting table in the manual. If the problem persists, contact Güde service at +49 (0) 79 04 / 700-360 or support@ts.guede.com. Have the serial number and product number ready.

User questions about GS 750.1 INOX Güde

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Water pump in PDF format for free! Find your manual GS 750.1 INOX - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GS 750.1 INOX by Güde.

USER MANUAL GS 750.1 INOX Güde

Güde GS 750.1 INOX - 1

GS 750.1 INOX

94679

GÜDE GmbH & Co. KG

Birkichstrasse 6

74549 Wolpertshausen

Deutschland

CE

Güde®

Güde GS 750.1 INOX - 3

ENGLISH Please read the instructions carefully before starting the machine.

Exterior view of a GS 750.1 INOX water heater with blue handle and black side panel (no text or symbols on body)

DE Anschluss

EN Connection

FR Raccordement

IT Raccordo

ES Conexión

NL Aansluiting

CZ Přípojka

SK Pripojenie

PL Podłączenie

HU Csatlakoztatás

1

2-3

DE Inbetriebnahme

EN Starting-up the device

FR Mise en service

DE Anschluss

EN Connection

FR Raccordement

IT Raccordo

ES Conexión

NL Aansluiting

CZ Přípojka

SK Pripojenie

PL Podłączenie

HU Csatlakoztatás

1

Güde GS 750.1 INOX - DE Inbetriebnahme - 1

Güde GS 750.1 INOX - DE Inbetriebnahme - 2

Güde GS 750.1 INOX - DE Inbetriebnahme - 3

b 1" AG

Close-up of industrial piping and valve assembly with no visible text or symbols

C 32 mm

Close-up of a black pipe fitting with coiled tubing and a small component, no visible text or symbols

d 1½" AG

Close-up of a pipe fitting with a black plastic connector and directional arrows indicating rotation (no text or symbols)

2DE InbetriebnahmeEN Starting-up the deviceFR Mise en serviceIT Messa in funzioneES Puesta en marchaNL InbedrijfstellingCZ Uvedení do provozuSK Uvedenie do prevádzkyPL UruchomienieHU Üzembe helyezés

2

Güde GS 750.1 INOX - 2 - 1

Illustration of a diver in mid-air during a water disturbance, with bubbles and directional arrows indicating flow or movement (no text or symbols)

Safety warning illustration showing a hand using a device to lift a water pump, with safety symbols and checkmarks.

2 1

3 3 2 1

3DE BetriebCZ Provoz
EN OperationSK Prevádzka
FR FonctionnementPL Operacja
IT EsercizioHU Üzemeltetés
ES Operação
NL Gebruik

Güde GS 750.1 INOX - 2 - 6

1 START ← GS 70-11 WATER

2 5 SEC

3 20 sec

4 STOP →

2
Illustration of a hand holding a water dispenser with liquid dripping (no text or symbols)

5
Close-up of a black industrial spray gun with attached cable and plug (no visible text or symbols)

4
Silhouette of a person walking with a trash can (no text or symbols)

5
Exterior view of a portable water purifier with no visible text or symbols on the device itself

Technische Daten

Submersible sewage pumpGS 750.1 INOX
Art. No 94679
Rated voltage 230 V
Degree of protection IP X8
Max. delivered quantity 15.000 l/h
Max. head of delivery Hmax 8 m
Max. immersion7 m
Max. suction35 mm
Max. Water temperature 35 °C
Service connection 1 1/2" IG
Cable length 10 m
Weight 6,5 kg

Güde GS 750.1 INOX - 2 - 15

Güde GS 750.1 INOX - 2 - 16

Read and understand the operating instructions before using the appliance. Familiarise with the control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.

The operator is responsible for accidents or risks to third parties.

In case of any doubts about connection and operation refer please to our customer center

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.

Cleaning and user maintenance shall not be made by children without supervision.

Children should be supervised in order to ensure that they do not play with the tool. Always keep children and unauthorised persons out of reach of the appliance.

Specified Conditions of Use

The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm and agriculture and only for water. Respecting technical data and safety precautions.

Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.

Do not use pump at outside temperatures over 40 °C or under 0 °C

The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
⚠ Do not use the pump for drinking water!
⚠ The pump must not be used to pump waste water.
The pump must not be connected to the existing water-supply network as a pressure-boosting device.
⚠️ Never use the pump as a pool circulation pump.

Safety Warnings

⚠ WARNING! Electric shock! There is a risk of an injury caused by electric shock!

Check the cable and/or socket for damages before the appliance putting into operation.

Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!

It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.

Check the voltage. Technical data given on the type label must correspond with electric network voltage.

Only use splash proof extension cables approved for outdoor purposes.

Unplug the device prior to submersion, upon termination of operation, in the course of defect removal and prior to performing maintenance procedures.

Güde GS 750.1 INOX - ⚠ WARNING! Electric shock! There is a risk of an injury caused by electric shock! - 1

WARNING!

Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).

Electric connection to a socket.

If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).

The temperature of the drained liquid must not exceed +35 °C.

The pump must not in any case run without fillings.

Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.

If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.

The user is responsible to third parties if pump (dumping stations, etc.) is used.

Protect the feeder cable from excessive temperatures, oil and sharp edges.

To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.

Requirements for operating staff

The operating staff must carefully read the Operating Instructions before using the appliance.

Qualification: Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.

Minimum age: Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.

Training: Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary.

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information: 1. Accident site, 2. Accident type, 3. Number of injured persons, 4. Injury type(s)

SYMBOLS

Güde GS 750.1 INOX - SYMBOLS - 1

WARNING/CAUTION!

Güde GS 750.1 INOX - SYMBOLS - 2

WARNING - Read the operating instructions to reduce the risk of injury.

Güde GS 750.1 INOX - SYMBOLS - 3

Machine to be always unplugged before any adjustment and servicing work on it.

Güde GS 750.1 INOX - SYMBOLS - 4

Staying in the transportation medium prohibited

Güde GS 750.1 INOX - SYMBOLS - 5

Warning against dangerous voltage

Güde GS 750.1 INOX - SYMBOLS - 6

AC Current

Güde GS 750.1 INOX - SYMBOLS - 7

Max. immersion

Güde GS 750.1 INOX - SYMBOLS - 8

Voltage

Güde GS 750.1 INOX - SYMBOLS - 9

Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.

Güde GS 750.1 INOX - SYMBOLS - 10

CE marking

Maintenance

Güde GS 750.1 INOX - Maintenance - 1

Before any adjustment, cleaning and maintenance work, switch off the device and disconnect it from the power supply.

Before using the appliance, perform a visual inspection at all times to make sure the power cord and the plug, in particular, are not damaged on the charger.

The appliance must not be used if damaged or safety equipment is defective. Replace any worn-out and damaged parts.

If the supply cord of this power tool is damaged, it cannot be replaced, and the power tool shall be scrapped.

Repairs and works specified in these Instructions may only be performed by qualified authorised staff.

Use only original accessories and original spare parts.

Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.

To ensure long service life of the pump seal we recommend rinsing the pump with clean water in regular intervals.

Caution! Depending on the design, water that is left standing for a longer period of time may cause corrosion in the pump housing! (Brown colouration)

For winter storage, ensure that there is no water in the device. Otherwise, frost exposure may cause irreparable damage to the device. The pump must be stored in a completely empty and frost-proof state. You can reduce the chance of the mechanical seals sticking by flushing out the pump with suitable oil (e.g. vegetable oil).

If necessary, a list of spare parts can be found at www.guede.com.

Guarantee

Warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device.

The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.

The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.

GÜDE cannot be held responsible for damages incurred in consequence of unqualified installation or unskilled handling of the pump.

The device has to be checked on a regular basis to ensure perfect functioning.

Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases:

Unprofessional repairs executed by unauthorised service centres;

  • Use in conflict with the designed purpose, or failure to observe the use as designed;
  • Pump overload with a continuous run;
  • Damage as a result of icing or any other fault caused by climatic influences;
    Identical regulations apply for accessory parts.

To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).

Important information for the customer

Please note that returns within or outside the warranty period should always be in the original packaging.

This measure effectively avoids unnecessary transport damage and any associated disputed ruling.

Your equipment is optimally protected only in the original box, and keeping it in that box will ensure smooth processing.

Service

Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label.

Tel.: +49 (0) 79 04 / 700-360

Fax: +49 (0) 79 04 / 700-51999

E-Mail: support@ts.guede.com

Inspection and maintenance plan

Time interval Description Any other details
As needed Cleaning and rinsing. Check the float switch function.

Failures – causes - removal

Failures Causes Removal
Engine does not start No power supply.Blocked pump wheelCheck the voltageVisually inspect the pump wheel for foreign objectsCheck the water level
Floating switch in shutdown position
Pump does not suck Pump without waterWater level too lowLet the air bubbles release → 5Switch the pump off, water level must go up.
Hose connection to greatly reducedSelect as large hose connectionReplace hose connectionRemove the obstruction
Blocked pump wheel
Thermal detector swit-ching the pump off → 7Plugged strainerClean the strainer and let the pump cool downReduce the water temperatureMake more breaks
Water temperature too high
Pump running continuously at maximum pressure.
Insufficient amount of water pumpedDirty strainerClean the strainerEnsure sufficient inflowCheck the transport lineCheck the transport line
Water level quickly drops down
Maximum head of delivery exceeded
Broken piping

WAARSCHUWING/OPGELET!

Güde GS 750.1 INOX - Service - 1

Translation of the EC-Declaration of Conformity

We, hereby declare the conception and construction of the below mentioned appliances correspond - at the type of construction being launched - to appropriate basic safety and hygienic requirements of EC Directives.

In case of any change to the appliance not discussed with us the Declaration expires.

Notified Body Name: No: Adress:

Type Ex. Cert.-No.:

□ 97/68/EC_&2016/1628/EU

Emission No.:

2000/14/EC_2005/88/EC

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Güde

Model : GS 750.1 INOX