HiKOKI UC18YTSL - Multi-port charger

UC18YTSL - Multi-port charger HiKOKI - Free user manual and instructions

Find the device manual for free UC18YTSL HiKOKI in PDF.

📄 60 pages English EN Download 💬 AI Question 9 questions ⚙️ Specs
Notice HiKOKI UC18YTSL - page 2
View the manual : Français FR English EN Español ES
Title Description
Product type Battery charger
Input voltage 220-240 V
Output voltage 14.4 V / 18 V
Battery compatibility HiKOKI Li-ion batteries
Charging time Variable depending on battery capacity
Dimensions Not specified
Weight Not specified
Recommended use To charge batteries from the HiKOKI range
Maintenance Clean regularly and check cables
Safety measures Do not use with damaged batteries
Warranty Consult the supplier for warranty details

Frequently Asked Questions - UC18YTSL HiKOKI

How to charge the HiKOKI UC18YTSL battery?
To charge the battery, simply insert it into the UC18YTSL charger and plug the charger into a power source. The indicator light will show when the battery is fully charged.
What is the charging time for a battery with the HiKOKI UC18YTSL?
The charging time depends on the battery model used. Generally, an 18V battery can take between 30 minutes and 1 hour to be fully charged.
Is the HiKOKI UC18YTSL compatible with all HiKOKI batteries?
The HiKOKI UC18YTSL is compatible with HiKOKI 18V series batteries. Please check the compatibility of specific models before use.
What to do if the charger does not turn on?
First, check that the charger is properly plugged in and that the outlet is working. If the charger still does not turn on, contact HiKOKI customer service.
How to know if the battery is fully charged?
The HiKOKI UC18YTSL charger is equipped with an indicator light. When the light turns green, it means the battery is fully charged.
Can the HiKOKI UC18YTSL be used for other brands of batteries?
No, the HiKOKI UC18YTSL is specifically designed for HiKOKI batteries. Using other brands may damage the charger and the battery.
How to maintain the HiKOKI UC18YTSL?
Make sure to keep the charger clean and dry. Avoid exposing the charger to extreme heat or humidity conditions.
Is there a warranty for the HiKOKI UC18YTSL?
Yes, the HiKOKI UC18YTSL is generally covered by a limited warranty. Contact your dealer or HiKOKI customer service for more details on warranty conditions.
What to do if the battery overheats during charging?
Unplug the charger immediately and let the battery cool down to room temperature. Do not attempt to reuse the battery until it is completely cooled.

User questions about UC18YTSL HiKOKI

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

L'email reste privé : il sert seulement à vous prévenir si quelqu'un répond à votre question.

No questions yet. Be the first to ask one.

Download the instructions for your Multi-port charger in PDF format for free! Find your manual UC18YTSL - HiKOKI and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UC18YTSL by HiKOKI.

USER MANUAL UC18YTSL HiKOKI

SAFETY INSTRUCTIONS AND INSTRUCTION MANUAL

WARNING

IMPROPER OR UNSAFE use of this power tool can result in death or serious bodily injury! This manual contains important information about product safety. Please read and understand this manual before operating the power tool. Please keep this manual available for other users and owners before they use the multi port charger. This manual should be stored in safe place.

INSTRUCTIONS DE SECURITE ET MODE D'EMPLOI

AVENTISSEMENT

IMPORTANT SAFETY INSTRUCTIONS

Read and understand all of the safety precautions, warnings and operating instructions in the Instruction Manual before operating or maintaining this multi port charger.

Most accidents that result from multi port charger operation and maintenance are caused by the failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing a potentially hazardous situation before it occurs, and by observing appropriate safety procedures.

Basic safety precautions are outlined in the "SAFETY" section of this Instruction Manual and in the sections which contain the operation and maintenance instructions.

Hazards that must be avoided to prevent bodily injury or machine damage are identified by WARNINGS on the multi port charger and in this Instruction Manual.

NEVER use this multi port charger in a manner that has not been specifically recommended by metabo HPT.

MEANINGS OF SIGNAL WORDS

WARNING indicates a potentially hazardous situations which, if ignored, could result in death or serious injury.

CAUTION indicates a potentially hazardous situations which, if not avoided, may result in minor or moderate injury, or may cause machine damage.

NOTE emphasizes essential information.

SAFETY

IMPORTANT SAFETY INSTRUCTIONS FOR MULTI PORT CHARGER

HiKOKI UC18YTSL - IMPORTANT SAFETY INSTRUCTIONS FOR MULTI PORT CHARGER - 1

WARNING: Death or serious bodily injury could result from improper or unsafe use of multi port chargers. To avoid these risks, follow these basic safety instructions:

READ ALL INSTRUCTIONS

  1. SAVE THESE INSTRUCTIONS: This manual contains important safety and operating instructions for multi port charger Model UC18YTL.
  2. Before using multi port charger, read all instructions and cautionary markings on (1) multi port charger, (2) battery, and (3) product using battery.
  3. CAUTION: To reduce risk of injury, charge only metabo HPT rechargeable battery types BSL14 series, BSL18 series, and MV series. Other type of batteries may burst causing personal injury and damage.
  4. Do not expose multi port charger to rain or snow.
  5. Use of an attachment not recommended or sold by the multi port charger manufacturer may result in a risk of fire, electric shock, or injury to persons.
  6. To reduce risk of damage to electric plug and cord, pull by plug when disconnecting port charger.
  7. Make sure cord is located so that it will not be stepped on, tripped over, or otherwise subjected to damage or stress.
  8. An extension cord should not be used unless absolutely nec extension cord could result in a risk of fire and electric shock.

If extension cord must be used make sure:

a. That blades of extension cord are the same number, size, and shape as those of plug on multi port charger:
b. That extension cord is properly wired and in good electrical condition; and
c. That wire size is large enough for AC ampere rating of multi port charger as specified in Table 1.

Table 1
RECOMMENDED MINIMUM AWG SIZE FOR
EXTENTION CORDS FOR MULTI PORT CHARGERS

AC Input Rating Amperes*AWG Size of Cord
Equal to or greater thanbut less thanLength of Cord, Feet (Meter)
25 (7.5)50 (15)100 (30)150 (45)
0218181816
2318181614
3418181614
  • If the input rating of a multi port charger is given in watts rather than in amperes, the corresponding ampere rating is to be determined by dividing the wattage rate voltage rating-for example:

$$ \frac {1 , 2 5 0 \mathrm {w a t t s}}{1 2 5 \mathrm {v o l t s}} = 1 0 \mathrm {a m p e r e s} $$

  1. Do not operate multi port charger with damaged cord or plug-replace them immediately.
  2. Do not operate multi port charger if it has received a sharp blow, been dropped, or otherwise damaged in any way; take it to a qualified serviceman.
  3. Do not disassemble multi port charger; take it to a qualified serviceman when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, unplug charger from receptacle by maintenance or cleaning. Removing the battery will not reduce this risk.
  5. This multi port charger might be attached to metabo HPT battery operated tools as a standard accessory. In this case, please confirm Instruction Manual of the metabo HPT battery operated tools before using the multi port charger.

IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE BATTERY AND MULTI PORT CHARGER

You must charge the battery before you can use the power tool. Before using the model UC18YTSL multi port charger, be sure to read all instructions and cautionary statements of the battery and in this manual.

CAUTION: USE ONLY metabo HPT BATTERY TYPES BSL14 SERIES, BSL18 SERIES, AND MV SERIES. OTHER TYPES OF BATTERIES MAY BURST AND CAUSE INJURY!

Follow these instructions to avoid the risk of injury:

WARNING: Improper use of the battery or multi port charger can lead to serious injury. To avoid these injuries:

  1. NEVER disassemble the battery.
  2. NEVER incinerate the battery, even if it is damaged or is completely worn out. The battery can explode in a fire.
  3. NEVER short-circuit the battery.
  4. NEVER insert any objects into the multi port charger's air vents. Electric shock or damage to the multi port charger may result.
  5. NEVER charge outdoors. Keep the battery away from direct sunlight and use only where there is low humidity and good ventilation.
  6. NEVER charge when the temperature is below 14^ (-10^) or above 104^ (40^) .
  7. NEVER connect two multi port chargers together.
  8. NEVER insert foreign objects into the hole for the battery or the multi port charger.
  9. NEVER use a booster transformer when charging.
  10. NEVER use DC power to charge.
  11. NEVER store the battery or multi port charger in places where the temperature may reach or exceed 104^ (40^) .

  12. NEVER expose the battery or multi port charger to rain or wet conditions.

  13. ALWAYS operate charger on standard household electrical power (120 volts). Using the charger on any other voltage may overheat and damage the charger.
  14. ALWAYS disconnect the power cord from its receptacle when the charger is not in use.

USB DEVICE CONNECTION PRECAUTIONS

When an unexpected problem occurs, the data in a USB device connected to this product may be corrupted or lost. Always make sure to back up any data contained in the USB device prior to use with this product.

Please be aware that our company accepts absolutely no responsibility for any data stored in a USB device that is corrupted or lost, nor for any damage that may occur to a connected device.

DISPOSAL OF THE EXHAUSTED BATTERY

WARNING: Do not dispose of the exhausted battery. The battery must explode if it is incinerated. The product that you have purchased contains a rechargeable battery. The battery is recyclable. At the end of it's useful life, under various state and local laws, it may be illegal to dispose of this battery into the municipal waste stream. Check with your local solid waste officials for details in your area for recycling options or proper disposal.

SAVE THESE INSTRUCTIONS AND MAKE THEM AVAILABLE TO OTHER USERS AND OWNERS OF THIS TOOL!

The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of the multi port charger.

NEVER operate, or attempt any maintenance on the multi port charger unless you have first read and understood all safety instructions contained in this manual.

Some illustrations in this Instruction Manual may show details or attachments that differ from those on your own multi port charger.

HiKOKI UC18YTSL - SAVE THESE INSTRUCTIONS AND MAKE THEM AVAILABLE TO OTHER USERS AND OWNERS OF THIS TOOL! - 1
NAME OF PARTS

HiKOKI UC18YTSL - SAVE THESE INSTRUCTIONS AND MAKE THEM AVAILABLE TO OTHER USERS AND OWNERS OF THIS TOOL! - 2
Fig. 1

SPECIFICATIONS

Model UC18YTSL
Input power source Single phase: AC 120 V, 60 Hz
ChargerBatteryCharging voltage............DC 14.4 V - 18 V Charging current BSL36B18 / BSL1860 / BSL1850 / BSL36A18 / BSL1840 / BSL1830 / BSL1460 / BSL1450 / BSL1440 / BSL1430............DC 8.0 A BSL1830C / BSL1825 / BSL1820 / BSL1815 / BSL1815X / BSL1815S BSL1430C / BSL1425 / BSL1420 / BSL1415 / BSL1415X / BSL1415S............DC 6.0 A
USB × 2Charging voltage............DC 5 V Charging current............DC total 2 A
Weight 3.3 lbs (1.5 kg)

APPLICATIONS

For charging the metabo HPT batteries types BSL14 series, BSL18 series, and MV series.
For recharging USB devices.
For using as AC power supply outlets.

CHARGING MODE SELECTION

This device is capable of charging up to four rechargeable batteries modes.

Rechargeable batteries can be charged in any of the ports, both in normal mode and in Multi Mode.

When the mode selector switch is off, batteries are charged in normal mode. When the switch is on, they are charged in Multi Mode. (Fig. 2)

HiKOKI UC18YTSL - CHARGING MODE SELECTION - 1
Fig. 2

Mode Normal Multi
PurposeTo charge a number of batteries in sequence.To charge all batteries simultaneously.
Charging methodCharges in sequence from port numbers 1 to 4.Charges all batteries uniformly.
Mode selector switch OFF ON
Mode indicator lampOFF Multi ModeON Multi Mode

Normal Mode (Mode selector switch off )

Rechargeable batteries are charged in the order of the port numbers (1 2 3 4) . (Fig. 3)

HiKOKI UC18YTSL - Normal Mode (Mode selector switch off ) - 1
Fig. 3

The charge indicator lamp turns green when the corresponding rechargeable battery is fully charged, and the buzzer emits a beep to notify the user.

The time taken to fully charge all batteries will be the total of the charging time for each battery. In the example shown in Table 1, the time taken to fully charge the battery in port number 2 will be the total time taken to charge the batteries in port numbers 1 and 2 (32 minutes + 52 minutes = 84 minutes).

Tip

Rechargeable batteries you wish to use soon should be inserted in order from port number 1.

Multi Mode (Mode selector switch on)

All batteries will be charged simultaneously. The charge indicator lamps turn green when all rechargeable batteries are fully charged, and the buzzer emits a beep to notify the user. In the example shown in Table 1, it will take 152 minutes to fully charge all four batteries simultaneously.

Table 1 Charging example

Port No.Rechargeable battery Charging time*
1 BSL 185032 minutes
2 BSL 36B1852 minutes
3 BSL 186038 minutes
4 BSL 1430C30 minutes
Total charging time 152 minutes
  • Charging time will vary depending on the residual capacity of the batteries.

General points applying to both modes

The battery currently being charged is the port indicated by the steady red illuminated charge indicator lamp.
- Batteries that are hot immediately after being used or cold due to low-temperature conditions take longer to charge, so they are skipped and charged after the other batteries.
If charging is taking a long time, press the selector switch twice.

This resets the charger, reassesses batteries that are either hot immediately after use or cold due to low-temperature conditions, and skips them before resuming charging.

Normal mode

  • If a battery is inserted in a port with a lower number (i.e., higher priority) port while other batteries are being charged, charging of the newly inserted battery will start after the battery currently being charged has been fully charged.

Multi mode

If rechargeable batteries are used before they are fully charged, the level of charging may vary from battery to battery.
- Inserting a depleted battery into a vacant port while other batteries are being charged will increase the time taken to charge all the batteries.

CHARGING METHOD

NOTE: Before plugging into the receptacle, make sure the following points.

The power source voltage is stated on the nameplate.
The cord is not damaged.

WARNING: Do not charge at voltage higher than indicated on the nameplate. If charged at voltage higher than indicated on the n a charger will burn up.

  1. Connect the multi port charger's power cord to the receptacle.

When connecting the plug of the charger to a receptacle, the charge indicator lamp will blink in red. (At 1-second intervals).

HiKOKI UC18YTSL - CHARGING METHOD - 1

WARNING: Do not use the electrical cord if damaged. Have it repaired immediately.

  1. Select the charging mode.

Select the charging mode to suit requirements. (Fig. 2) (See "CHARGING MODE SELECTION" on page 7.)

  1. Insert the battery to the multi port charger. Insert the battery into the multi port charger as shown in Fig. 4.

NOTE:

The charging lamps next to each of the four ports indicate the charging status of the corresponding battery being charged.

HiKOKI UC18YTSL - NOTE: - 1
Fig. 4

4. Charging

When inserting a battery in the charger, the charge indicator lamp will light up in red.

When the battery becomes fully recharged, the charge indicator lamp will light up in green.

(See Table 2)

(1) Charge indicator lamp indication

The indications of the charge indicator lamp will be as shown in Table 2, according to the condition of the multi port charger or the battery.

Table 2

Indications of the charge indicator lamp
Charge indicator lamp (RED / GREEN)Before chargingBlinks (RED)Lights for 0.5 seconds. Does not light for 0.5 seconds. (off for 0.5 seconds)Plugged into power source
While chargingLights (RED)Lights continuously
Charging completeLights (GREEN)Lights continuously (Continuous buzzer sound: about 6 seconds)
Overheat standbyBlinks (RED)Lights for 0.3 seconds. Does not light for 0.3 seconds. (off for 0.3 seconds)Battery overheated. Unable to charge. (Charging will commence when battery cools)
Charging impossibleFlickers (RED)Lights for 0.1 seconds. Does not light for 0.1 seconds. (off for 0.1 seconds) (Intermittent buzzer sound: about 2 seconds)Malfunction in the battery or the charger

(2) Regarding the temperature of the rechargeable battery.

The temperatures for rechargeable batteries are as shown in the Table 3, and batteries that have become hot should be cooled for a while before being recharged.

Table 3

Rechargeable batteriesTemperatures at which the battery can be recharged
BSL1415, BSL1415X, BSL1415S, BSL1425, BSL1430C, BSL1815, BSL1815X, BSL1815S, BSL1820, BSL1825, BSL1830C, BSL1420, BSL1430, BSL1450, BSL36A18, BSL1460, BSL1830, BSL1440, BSL1840, BSL1850, BSL1860, BSL36B1832°F – 122°F (0°C – 50°C)

(3) Regarding recharging time

Table 4 shows the recharging time required according to the type of battery.

Table 4 Recharging time (approx. min.) at 20^

Battery CapacityLi-ion BATTERY
Battery Voltage
14.4 V 18 V
1.3 Ah BSL1415S 15 min.BSL1815S 15 min.
1.5 AhBSL141515 min.BSL181515 min.
BSL1415XBSL1815X
2.0 Ah BSL1420 20 min.BSL1820 20 min.
2.5 Ah BSL1425 25 min.BSL1825 25 min.
3.0 AhBSL1430C30 min.BSL1830 30 min.
BSL1430 20min.20 min.
4.0 Ah BSL1440 26 min.BSL1840 26 min.
5.0 Ah BSL1450 32 min.BSL185032 min.
BSL36A18
6.0 Ah BSL1460 38 min.BSL1860 38 min.
8.0 AhBSL36B1852 min.

NOTE:

The battery charging times may increase depending on the ambient conditions and battery conditions.

The battery charging times apply to charging one battery on its own. When charging multiple batteries, the total charging time will be the sum of the individual charging times.

Charging time will increase if the ambient temperature is below 0^

  1. Disconnect multi port charger from the receptacle.

HiKOKI UC18YTSL - NOTE: - 1

CAUTION: Do not pull the plug out of the receptacle by pulling on the cord. Make sure to grasp the plug when removing from receptacle to avoid damaging cord.

  1. Remove the battery from the multi port charger.

Supporting the multi port charger with hand, pull out the battery from the multi port charger.

NOTE:

Be sure to pull out the battery from the multi port charger after use, and then keep it.

Regarding electric discharge in case of new batteries, etc.

As the internal chemical substance of new batteries and batteries that have not been used for an extended period is not activated, the electric discharge might be low when using them the first and second time. This is a temporary phenomenon, and normal time required for recharging will be restored by recharging the batteries 2 - 3 times.

How to make the batteries perform longer.

Recharge the batteries before they become completely exhausted.
When you feel that the power of the tool becomes weaker, stop using the tool and recharge its battery. If you continue to use the tool and exhaust the electric current, the battery may be damaged and its life will become shorter.
Avoid recharging at high temperatures.

A rechargeable battery will be hot immediately after use. If such a battery is recharged immediately after use, its internal chemical substance will deteriorate, and the battery life will be shortened. Leave the battery and recharge it after it has cooled for a while.

CAUTION:

If the battery is charged while it is heated because it has been left for a long time in a location subject to direct sunlight or because the battery has just been used, the charge indicator lamp of the charger lights for 0.3 seconds, does not light for 0.3 seconds (off for 0.3 seconds).
The battery will not be recharged. In such a case, let the battery cool before charging.
- When the charge indicator lamp flickers (at 0.2-second intervals), check for and take out any foreign objects in the charger's battery connector. If there are no foreign objects, it is probable that the battery or charger is malfunctioning. Take it to your authorized Service Center.

HOW TO RECHARGE USB DEVICE

WARNING

Prior to use, check the connecting USB cable for any defect or damage.
Using a defective or damaged USB cable can cause smoke emission or ignition.
Use a connecting USB cable of less than 2m
- When the product is not being used, cover the USB port with the rubber cover.

Buildup of dust etc. in the USB port can cause smoke emission or ignition.

NOTE:

The time required for charging will be longer when a USB device and battery are being simultaneously charged.
There may be an occasional pause during USB recharging.
- When a USB device is not being charged, turn the USB power switch OFF and remove the USB device from the charger.

Failure to do so may not only reduce the battery life of a USB device, but may also result in unexpected accidents.

  • It may not be possible to charge some USB devices, depending on the type of device.
    The USB charging current should not exceed a total of 2 A for the two USB charging ports.

Doing so may cause the charger to malfunction.

(1) Select a charging method

Depending on the charge method selected, either the battery is inserted into the charger or the power cord is plugged into an outlet.

Charging a USB device by battery (Fig. 5-a)
Charging a USB device from a electrical outlet (Fig. 5-b)
- Charging a USB device and battery from a electrical outlet (Fig. 5-c)

HiKOKI UC18YTSL - NOTE: - 1
a

HiKOKI UC18YTSL - NOTE: - 2
b

HiKOKI UC18YTSL - NOTE: - 3
C
Fig. 5

NOTE:

When charging a USB device from a rechargeable battery, insert the rechargeable battery into battery charging port No. 1. (Fig. 3)

(2) Turn the USB power switch ON (Fig. 6)

When you turn the USB power switch ON, the USB power indicator lamp will light up.

HiKOKI UC18YTSL - NOTE: - 1
Fig. 6

(3) Connect the USB cable. (Fig. 6)

Pull back the rubber cover and firmly plug in a commercially available USB cable (appropriate to the device being charged) into the USB port.

  • When the power cord is not plugged into an outlet and the battery runs out of power, power output will stop and the USB power indicator lamp will shut off.
  • When the USB power indicator lamp goes out, change the battery or plug the power cord into an electrical outlet.

(4) When charging is completed (Fig. 7)

The USB power indicator lamp will not go out when a USB device has been completely charged.

To verify charge status, check the USB device.

Turn the USB power switch OFF and unplug the power cord from the electrical outlet. (Fig. 7)
Remove the battery from the charger and place the rubber cover over the USB port.

HiKOKI UC18YTSL - NOTE: - 2
Fig. 7

BEFORE USE

Check the work area to make sure that it is clear of debris and clutter.

Clear the area of unnecessary personnel. Ensure that lighting and ventilation is adequate.

USING AS AN AC POWER SUPPLY

WARNING

Grounded plugs cannot be used with the charger.
Note that devices that require grounding pose the risk of electric shock.
Check the individual device before use.

The product includes convenient AC outlets for use as a power supply for AC devices. (Two locations: Total current capacity is 10 A.)

AC devices can be used by plugging them into the AC outlets on the charger with the charger power supply plug plugged into an electrical outlet.

HiKOKI UC18YTSL - WARNING - 1
Fig. 8

NOTE:

AC devices connected to the charger should not exceed a total of 10 A.

Doing so may cause the charger to malfunction.

Read the instruction manual carefully for the device to be used, and check the current rating before use.

  • Make sure the charger power supply plug is plugged into an electrical outlet while using an AC device.

HiKOKI UC18YTSL - NOTE: - 1
Fig. 9

(1) Select usage configuration
Using an AC device with power supplied from an electrical outlet. (Fig. 9-a)
Using an AC device and charging a battery with power supplied from an electrical outlet. (Fig. 9-b)

MAINTENANCE AND INSPECTION

HiKOKI UC18YTSL - MAINTENANCE AND INSPECTION - 1

CAUTION: Pull out battery before doing any inspection or maintenance.

HiKOKI UC18YTSL - MAINTENANCE AND INSPECTION - 2

  1. Check for Dust

  2. Check the Screws
    Loose screws are dangerous. Regularly inspect them and make sure they are tight.
    CAUTION: Using this multi port charger with loosened screws is extremely dangerous.

Dust may be removed with a soft cloth or a cloth dampened with soapy water.

Do not use bleach, chlorine, gasoline or thinner, for they may damage the plastics.

HiKOKI UC18YTSL - MAINTENANCE AND INSPECTION - 3

CAUTION: In the operation and maintenance of power tools, the safety regulations and standards prescribed in each country must be observed.

TRANSPORTATION AFTER USE

WARNING: Detach any batteries from the charger before transporting.

Damages or injuries may occur if the batteries fall off.

HiKOKI UC18YTSL - WARNING: Detach any batteries from the charger before transporting. - 1
Fig. 10

A carrying handle is provided for easy carrying after use. The handle can be stowed in the main unit for compactness when not in use.

HiKOKI UC18YTSL - WARNING: Detach any batteries from the charger before transporting. - 2
Fig. 11

STORAGE

Storing in a place below 104^ (40^) and out of the reach of children.

SERVICE AND REPAIRS

All quality power tools will eventually require servicing or replacement of parts because of wear from normal use. To assure that only authorized replacement parts will be used, all service and repairs must be performed by a metabo HPT AUTHORIZED SERVICE CENTER, ONLY.

NOTE:

Specifications are subject to change without any obligation on the part of the metabo HPT.

TROUBLESHOOTING GUIDE

HiKOKI UC18YTSL - TROUBLESHOOTING GUIDE - 1

WARNING

All electrical or mechanical repairs should be done only by qualified service technicians. Contact metabo HPT Authorized Service Center.

Problem PossibleCause Possible Solution
The charge indicator lamp is rapidly flickers red, and battery charging doesn't begin.The battery is not inserted all the way.Insert the battery firmly.
There is foreign matter in the battery terminal or where the battery is attached.Remove the foreign matter.
The charge indicator lamp blinks red, and battery charging doesn't begin.The battery is not inserted all the way.Insert the battery firmly.
The battery is overheated. If left alone, the battery will automatically begin charging if its temperature decreases, but this may reduce battery life. It is recommended that the battery be cooled in a well-ventilated location away from direct sunlight before charging it.
Battery usage time is short even though the battery is fully charged.The battery's life is depleted. Replace the battery with a new one.
The battery takes a long time to charge.The temperature of the battery, the charger, or the surrounding environment is extremely low.Charge the battery indoors or in another warmer environment.
The charger's vents are blocked, causing its internal components to overheat.Avoid blocking the vents.
The cooling fan is not running. Contact a metro HPT Authorized Service Center for repairs.
The USB power lamp has switched off and the USB device has stopped charging.The battery's capacity has become low. Replace the battery with one that has capacity remaining.
USB power lamp does not switch off even though the USB device has fi nished charging.The USB power lamp lights up green to indicate that USB charging is possible.This is not a malfunction.
It is unclear what the charging status of a USB device is, or whether its charging is complete.The USB power lamp does not switch off even when charging is complete.Examine the USB device that is charging to confirm its charging status.
Charging of a USB device pauses midway.The charger was plugged into an electrical socket while the USB device was being charged using the battery as the power source.This is not a malfunction. The charger pauses USB charging for about 5 seconds when it is diff erentiating between power sources.
A battery was inserted into the charger while the USB device was being charged using a power socket as the power source.
Charging of the USB device pauses midway when the battery and the USB device are being charged at the same time.The battery has become fully charged. Thisis not a malfunction. The charger pauses USB charging for about 5 seconds while it checks whether the battery has successfully completed charging.
Charging of the USB device doesn't start when the battery and the USB device are being charged at the same time.The remaining battery capacity is extremely low.This is not a malfunction. When the battery capacity reaches a certain level, USB charging automatically begins.
AC devices cannot be used even when they are plugged into the AC outlets on the charger.The charger fuse has tripped due to excessive load from the AC device.Contact a metabo HPT Authorized Service Center for repairs.
AC devices should not exceed a total of 10 A.
Devices do not charge even when they are connected to the USB ports.The charger fuse has tripped due to excessive load from the USB device.Contact a metabo HPT Authorized Service Center for repairs.
USB devices should not exceed a total of 2 A.

CONSIGNES DE SECURITE IMPORTANTES

Please contact Koki Holdings America Ltd. at 1-800-59-TOOLS (toll free), or metabo HPT AUTHORIZATION POWER TOOL SERVICE CENTER regarding COLLECTION.

HiKOKI UC18YTSL - CONSIGNES DE SECURITE IMPORTANTES - 1

Pour le RAMASSAGE,contacter Koki Holdings America Ltd. au 1-800-59-TOOLS (appel gratuite), ou UN SERVICE APRES-VENTE D'OUTILS ÉLECTRIQUE AGRÉE PAR metabo HPT.

HiKOKI UC18YTSL - CONSIGNES DE SECURITE IMPORTANTES - 2

Shinagawa Intercity Tower A, 15-1, Konan 2-chome, Minato-ku, Tokyo 108-6020, Japan

Distributed by

Koki Holdings America Ltd.

1111 Broadway Ave, Braselton, Georgia, 30517

Koki Holdings America Ltd. Canadian Branch

3405 American Drive, Units 9-10, Mississauga, ON, L4V 1T6

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : HiKOKI

Model : UC18YTSL

Category : Multi-port charger