Product TypeAir Dehumidifier
BrandEurom
ModelLO20
Supply Voltage220-240 V ~ 50 Hz
Maximum Dehumidification20 L/24h (at 30°C, RH 100%)
Power Consumption320 W
Current1.4 A
RefrigerantR290 (flammable) / 0.1 kg
Protection RatingIPXO
Dimensions (W × D × H)32 × 31 × 56 cm
Weight19 kg
Minimum Recommended Area4 m²
Operating Temperature5 °C to 32 °C
Control TypeRotary switch with hygrostat
Recommended Humidity Range45% to 65%
Automatic FunctionsAuto shut-off when tank full, auto defrost, compressor protection
Water DrainageRemovable 5 L tank (estimated); continuous drainage possible (hose inner diameter 10 mm)
Filter CleaningWashable filter with warm water (max 40 °C); dry completely before reinstalling
SafetyCan be used by children 8+ under supervision; R290 flammable, avoid ignition sources
Spare PartsAir filter available on request
Included AccessoriesUser manual

Frequently Asked Questions - LO20 Eurom

How to adjust the desired humidity?
Turn the rotary switch to MAX for lower humidity and continuous operation. The machine stops automatically when the humidity reaches the set level.
Why is the red 'water tank full' light on?
The water tank is full or incorrectly positioned. Empty it and put it back correctly; the light goes out. The appliance will not operate until the tank is in place.
How to set up continuous drainage?
Remove the tank, take out the rubber plug from the drain tube, connect a 10 mm diameter hose with a hose clamp, then put the tank back and route the hose through the designated opening to a drain.
Can I use an extension cord?
Using an extension cord is not recommended. If unavoidable, use a grounded extension cord with minimum cross-section 3×1.5 mm², power ≥1000 W / 6 A and unwind it completely.
What to do if the appliance does not turn on?
Check the outlet, voltage, ambient temperature (5-32°C), hygrostat setting, tank position, and ensure air inlets/outlets are not blocked.
How often should I clean the filter?
Clean the filter regularly, especially in dusty conditions. Remove it, gently tap or vacuum, wash with warm water (max 40°C) and mild detergent, dry completely before reinstalling. Never use without filter.
What type of refrigerant is used and what precautions?
The refrigerant is R290 (propane), flammable. Do not install in a room smaller than 4 m², avoid any ignition sources, do not puncture the circuit.
The appliance makes a liquid circulating sound, is this normal?
Yes, it is normal. The liquid sound occurs when the compressor starts and stops. Ensure the appliance is on a flat and stable surface.
Why is warm air coming out of the appliance?
This is normal: the dried air is slightly warmed by the condenser before being expelled. This is part of the dehumidification process.
How to store the appliance after use?
Turn off, unplug, clean and dry the tank, pack the appliance (preferably in original packaging) and store it away from direct sunlight.

User questions about LO20 Eurom

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Humidifier in PDF format for free! Find your manual LO20 - Eurom and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LO20 by Eurom.

USER MANUAL LO20 Eurom

natural_image Exterior view of a modern industrial vacuum cleaner (no visible text or symbols on the device body)

LO20

Art.nr. 372359

Dank

text_image Warning sign depicting a flame symbol in a triangular shape, indicating hazard or electrical hazard.

Eurom LO20 - Dank - 1

natural_image Illustration of open books, an open book with an open icon, and an open notebook with a wrench (no text or symbols)
natural_image Close-up of a hand inserting a dark rectangular object into a white panel, with no visible text or symbols.
text_image Warning symbol image showing a flame, open book, open book with information icon, and open wrench
natural_image Person handling a plastic waste container inside an industrial machine (no visible text or symbols)
natural_image Close-up of a hand holding a dark rectangular object with a label, next to an open air vent (no visible text or symbols)

Thank you very much for choosing for a EUROM device. You have made a good choice! We hope you will be satisfied about its functioning.

To get maximum profit from your product, it is important to read this manual attentive and totally before use, and to understand what is written. Read especially the safety instructions: they are there to protect you and your environment.

Keep the manual in a safe place for future reference. Store also the package: that is the best protection for your product in times of no-use. And if you at any time pass the appliance on, pass on the manual and package too.

We wish you a lot of fun with the LO20!

Eurom

Kokosstraat 20

8281 JC Genemuiden (NL)

info@eurom.nl

www.eurom.nl

This manual has been complied with the utmost care. Nevertheless, we reserve the right to optimize this manual at any time and to adjust it technically. The image used may differ.

Symbol statement

Eurom LO20 - Symbol statement - 1

text_image Warning symbol with flame, open book, open book icon, and open wrench icon
  • This appliance is filled with flammable Propane gas R290. Follow strictly the manufacturer's instruction concerning use and repairs!
  • Before using the machine, carefully read this entire instruction manual.
  • Do not install, operate or store the device in a room smaller than 4m^2 .

Technical details

Connected power230V~50Hz
Day dehumidification max.20 L (30°C RH100%)
Output capacity320 W
Cooling fluidR290/0,1kg
Power usage1,4A
Insolation classIPX0
Dimensions32 x 31 x 56 cm
Weight19 kg

Important safety instructions

Read all safety warnings and other instructions. Failure to follow all instructions can cause injury or material damage.

General

  1. Before use, please make sure the power outlet outputs 220-240V\~50Hz, is grounded and undamaged.

  2. Please do not plug or unplug to start up or shut off the device, but use the rotary switch.

  3. Ensure that the unit has a free space of at least 30 cm on each side.

  4. Make sure that the plug and socket remain visible and accessible at all times.

  5. Do not place any objects in front of the air conditioning unit.

  6. Never leave a functioning device unsupervised, not even for a moment!

  7. Please do not cut off the power by pulling the wire, but take the plug in your hand.

  8. Please be careful when moving the device.

  9. Please do not put finger, stick or other object into the grid.

  10. Please prohibit child to climb, stand or sit on the device, or to touch it.

  11. Please unplug the device before cleaning or maintenance.

  12. Please do not use the device in a room smaller than 4m^2 .

  13. If possible, do not use an extension cord, as this poses the risk of overheating and fire. If the use of an extension cord is unavoidable, then make sure it is an undamaged, approved extension cord with a minimum diameter of 3 × 1.5 mm^2 and a minimum permissible power of 1000 Watt/6 Amp. To prevent overheating, always fully extend the cord!

  14. Never block the grilles for incoming or outgoing air (not even partially). In order to prevent over-heating, never cover the device!

  15. Never insert fingers or objects such as pens into the device via the grilles and ensure that the ventilator does not become blocked.

  16. Do not use any relay, timer, dimmer or adapter. Otherwise, it might result in fire, radiation, or electric shock.

  17. Do not use the device in sunshine, wind or rain; it is only to use indoors.

  18. Do not use in places where chemicals or similar can be stored. Volatile substances can damage the device and cause leakage.

  19. Keep clean the plug and plug it into the socket properly. If the plug is not properly plugged in, the result may be a shock or fire. Never touch device or plug with wet hands!
  20. To prolong the life of the filter, pack it in a plastic bag when the device is not used for a longer time.
  21. When problems arise (for example a strange smell) switch the device off immediately and unplug it from the wall outlet. Otherwise, a fire, an electric shock or malfunction may result.
  22. Always ensure (even during transport!) that the unit remains upright. If the unit has been lying on its side, wait 2 hours before using. This time is required in order for the compressor to function correctly.
  23. Ensure that the unit is always placed on a sturdy, flat and horizontal surface.
  24. Cleaning and user maintenance shall not be made by children without supervision.
  25. Remove the plug from the socket when you hear strange noises, smell a strange smell, when there is smoke.
  26. Do not turn on the appliance if you have discovered damage to the appliance, cord or plug, if the appliance is malfunctioning, if it has been dropped or if there are signs of any other defect. Return the complete product to the vendor or to a certified electrician for inspection and/or repair. Always ask for original parts.
  27. Do not damage the electric cable and replace it never yourself. Do not place heavy objects on the cable and don't lead it around sharp corners. Keep it away from heat sources. Don't use a damaged electrical cable any more!
  28. When the device is used continuously, arrange a suitable drain. Do not use the device at temperatures around or below freezing point.
  29. Make sure that the machine is always in a stable and perfectly horizontal position. Otherwise, water may enter into the device and get through to essential elements, with fire, shock, etc. to possible result.
  30. Do not use the device near water or in spaces such as bathrooms and laundry rooms. If the device is too damp, fire or electric shock may occur.
  31. When you don't use the device for an extended period of time, disconnect the plug from the socket.
  32. Repairs to the appliance, cord and plug must only be carried out by qualified technicians.

Safety in relation to coolant R290

  1. This device contains the coolant R290. R290 is a coolant that complies with the relevant European Directives. Never perforate the coolant circuit. R290 is flammable (GWP 3)!
  2. This device must be used and stored in a room that does not contain sources of ignition, such as open flames or gas and electrical devices in operation.

  3. Do not perforate any of the components of the cooling circuit and do not set light to the device.

  4. If the device is installed, working or stored in an un-ventilated you must take measures to prevent fire or explosions caused by leaked coolant. Ensure that there are absolutely no sources of ignition (such as fire, heaters, sparking electrical equipment, lit cigarettes, etc.) in the same room!

  5. The device must be stored in such a way that mechanical defects are prevented.

  6. Do not install, operate or store the device in a room smaller than 4m^2 .

  7. R290 is odourless, which means that you cannot smell leaks!

  8. Persons working on the cooling circuit must be in possession of the correct qualifications that state the person in question is competent to use coolant in accordance with a special evaluation that is recognised by the sector association.

  9. The repairs must be executed on the grounds of the recommendations of the manufacturer of the device. Maintenance and repairs that require the assistance of other qualified persons must be executed under supervision of someone who is specialised in the use of flammable coolant.

  10. Disassembly and recycling of the device must be performed by a certified technician.

Description

  1. Rotary switch humidity

  2. 'Full water' indicator

  3. Air outlet (not visible)

  4. Handle

  5. Air inlet

  6. Air filter

  7. Water tank

  8. Opening for continuous drainage

Eurom LO20 - Description - 1

text_image 3 EUROM DRY BUST LO 20 1 2 4 5 6 7 8

This product is a dehumidifier. It controls relative humidity by passing the air through the unit, forcing the excess moisture to condensate over the cooling elements (evaporator). Contact with this cold surface causes the moisture in the air to condense. This condensed water then drains safely into the water tank. The dried air then passes through the condenser where it is slightly warmed and re-enters the room at a slightly elevated temperature. Your health and possessions thrive best in a humidity between 45% and 65%.

Position

Excess moisture will travel throughout your home, in the same way that cooking smells waft to every room in the house. For this reason, the dehumidifier should be positioned, so that it can draw this moist air towards it from all over the home.

Alternatively, if you have a serious problem in one area you can begin by positioning the dehumidifier close to this area and later moving it to a more central point.

When positioning the dehumidifier, ensure that it is placed on a level surface and that there is a minimum of 30 cm of space on either side of the unit to allow for efficient airflow.

If you move the unit, it should first be switched off and the water tank emptied.

We do not recommend the use of an extension lead, so please try to ensure that the unit is sufficiently close to a fixed mains socket. If it is necessary to use am extension lead, use one with earthing and please ensure the diameter of the wires of the cable is at least 1,5 mm2.

Don't place the device near a heater, stove or other heat source, and not in full sunshine. When the dehumidifier is in operation, outside doors and windows should be closed when necessary for most efficient use.

Operation

  1. Turn the rotary switch completely to OFF / MIN mode: the device is now deactivated. Plug into a earthed mains socket, corresponding to the specifications on the rating label.

  2. Turn the humidistat clockwise direction MAX. At one point you will hear the compressor catch on and the device starts its operation. The further you turn the knob to MAX, the lower you set the humidity.

  3. When the unit reaches the set humidity, it will automatically stop his works; when the humidity rises above the set value, the machine will turn on again.

  4. When you turn the rotary switch completely to MAX, the unit will operate continuously; by turning the rotary switch back to OFF / MIN you switch off the device. Press the rotary switch again to switch it off again.

  5. After use, always remove the plug from the socket.

Drainage

While the water tank is full, the device will stop for self-protection and the water full indicator will turn into red.

To move the water tank, pull it out squarely from the unit.

After emptying the water tank, place the water tank into space. Make sure it is properly positioned, in order for the 'water full' sign to go out and your dehumidifier is operating.

Please note: in case, the water tank has not been positioned well, the water full indicator will turn into red. The equipment does not work.

Continuous drainage

When the dehumidifier is operated at very high humidity levels, the water tank will require more frequent drainage. In this situation, it may be more convenient to set the unit up for continuous drainage with the following procedures:

  1. Pull out the water tank.
  2. Remove the rubber cap from the drain pipe on the side of the tank.
  3. Connect a hose with an inner diameter of 10 mm to the water discharge pipe with a hose clamp on the drain pipe.
  4. Put the water tank back to its position and lead the tube through the opening for continuous drainage down into a drain or a big container.

  5. Ensure the water will always drain away freely and the tube will remain in right place. Note! In very cold weather conditions, precautions should be taken to prevent the water tube from freezing.

Eurom LO20 - Continuous drainage - 1

natural_image Person handling a plastic bag inside a metal enclosure (no visible text or symbols)

Defrosting

When the device operates at low temperature, the evaporator may freeze. That affects the dehumidification. The device will automatically stop operation every 36 minutes to defrost.

Compressor protection

If you have turned off the device, you cannot start it again during the first three minutes after that. This is to protect the compressor.

Maintenance

Always unplug the unit from the mains before carrying out any maintenance or cleaning of the unit.

Cleaning the body

Use a soft cloth to wipe the unit clean. Don't ever use volatile chemicals, gasoline, detergents, chemically treated clothes, or other cleansing solutions. These all could possibly hurt the cabinet.

Cleaning the filter

• Extract the filter holder.
- Use a vacuum cleaner or tap the filter lightly for easy cleaning. If the filter is particularly dirty, use warm water (max. 40°C) with a small amount of a mild detergent.

- Make sure the filter is completely dry before replacing. Do not expose the filter to sunlight.

• Never use the appliance without a filter!

Eurom LO20 - Cleaning the filter - 1

natural_image Close-up of a hand inserting a dark rectangular object into a machine (no visible text or symbols)

The appliance (incl. cord and plug) may only be opened and/or repaired by properly authorized and qualified persons.

Storage

If not use the unit for an extended period of time. Please:

  • Press the unit off, unplug and tidy AC cord.
    • Completely empty the water tank and wipe it clean.
    • Cover the unit and store where it will not receive direct sunlight.

Trouble shooting

The unit does not operate:

√ Is the unit plugged in and is there voltage at the socket?
√ Is the room temperature below 5^ C or above 32^ C? If so, then it is out of the working range of the unit.
√ Is the rotary switch set high enough?
√ Check the water tank is positioned properly in the unit and it is not full.
√ Make sure the air inlet and outlet are not obstructed.

The unit seems to do little:

√ Is the filter dusty, contaminated?
√ Is the air intake or outlet blocked up?
√ Is the room humidity already quite low?
√ Are too many windows or doors open?
√ Is there something in the room producing lots of humidity?

The unit is leaking:

√ Make sure the unit and the watertank are not damaged and don't show cracks or deformations.
√ Is the machine is stable and perfectly horizontal?

The unit is too noisy:

√ Check whether the unit is sitting on a level, flat and solid surface.
√ Is the filter dusty, contaminated?

Warm air from the air outlet is normal. The circulation of the refrigerant can also make some noise during start and stop.

For other problems, please contact your service facility. The appliance (incl. cord and plug) may only be opened and/or repaired by properly authorized and qualified persons.

Disposal

Eurom LO20 - Disposal - 1

At its end of life, discard the device according to the local laws and regulations, or deliver the device to your supplier.

Attachments

The CE declaration can be found at the end of this manual.

Remerciements

text_image Warning symbol image showing a flame, open book, open book with information icon, and open wrench
natural_image Person holding a plastic waste bin in an industrial storage unit (no visible text or symbols)

Décongeler

natural_image Close-up of a hand inserting a dark granular substance into a black appliance (no visible text or symbols)

Stockage

declares the following device in sole responsibility:

Product: Dehumidifier

Brand name: EUROM

Model: LO20

Item number: 372359

Complies with the following harmonization rules:

Low Voltage Directive: LVD 2014/35/EU

Electromagnetic compatibility Directive: EMC 2014/30/EU

Restriction of Hazardous Substances RoHS Directive:2011/65/EU&(EU)2015/863

Applied harmonized standards:

EN 60335-2-40:2003+A11:2004+A12:2005+A1:2006+A2:2009+A13:2012

EN 60335-1:2012+A11:2014+A13:2017+A1:2019+A2:2019+A14:2019

EN 62233:2008

EN 55014-1:2017

EN 55014-2:2015

EN IEC 61000-3-2:2019

EN 61000-3-3:2013+A1:2019

Genemuiden, 25-05-2021

W.J. Bakker, alg. Dir.

Eurom LO20 - Stockage - 1

text_image akker.

Eurom

Kokosstraat 20

8281 JC Genemuiden

The Netherlands

info@eurom.nl