BRITA Purity Fresh C - Water filter

Purity Fresh C - Water filter BRITA - Free user manual and instructions

Find the device manual for free Purity Fresh C BRITA in PDF.

📄 86 pages English EN Download 💬 AI Question ⚙️ Specs
Notice BRITA Purity Fresh C - page 18
Pick your language and provide your email: we'll send you a specifically translated version.
SKIP

Frequently Asked Questions - Purity Fresh C BRITA

User questions about Purity Fresh C BRITA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Water filter in PDF format for free! Find your manual Purity Fresh C - BRITA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Purity Fresh C by BRITA.

USER MANUAL Purity Fresh C BRITA

1 Definition of Terms
2 General Information
3 Operating and Safety Instructions
4 Installation
5 Changing the Filter Cartridge
6 By-Pass and Capacity Tables
7 Repair
8 Troubleshooting
9 Technical Data
0 Information for Australian market

Français Page 26-33

Filter Heads PURITY C 0-70% with variable by-pass

*available only in Spain, France and Italy

Kombidämpfer und Backöfen / Combi ovens and conventional ovens /Fours vapeur et fours traditionnels / Combi-steamers en bakovens / Sistemi di cottura a vape combinati e forn di cottura / Hornos a vapor combinados y hornos convenciones / Parniki i piekarniki / Kombidampere og bageovne / Napokohbektomatbyи Илье CTmepbl

°dH (°KH) Recommended bypass settingPURITY C Quell ST - Filter capacity in litre
C25* C50C150 C300C$00C1100
410%403110027594583779213177
510%403110027594583779213177
610%403110027594583779213177
710%34694323653929667911295
810%3038252069343858449883
910%2697331839305651948785
1010%2426601656275046757906
1110%2206001505250042507188
1210%2025501380229238966589
1310%1865081273211535966082
1410%1734711183196433395647
1510%1614401104183331175271
1610%1514131035171929224941
1710%142388974161827504651
1810%134367920152825974392
1910%127347871144724614161
2010%121330828137523383953
2110%115314788131022263765
2210%110300753125021253594
2310%105287720119620333438
2410%101275690114619483294
2510%97264662110018703163
2610%93254637105817983041
2710%90244613101917312928
2810%8623659198216702824
2910%8322857194816122726
3010%8122055291715582635
3110%7821353488715082550
3210%7620651785914612471
3310%7320050283314172396
3410%7119448780913752325
3510%6918947378613362259

*available only in Spain, France and Italy

Filterköppe PURITY C 0 % und PURITY C 30 % mit fest eingestelltem Verschnitt Filter Heads PURITY C 0 % and PURITY C 30 % with fixed by-pass
Têtes de filtré PURITY C 0 % et PURITY C 30 % à by-pass fixe
PURITY C 0 % en PURITY C 30 % filterkoppen met vaste bypass
Teste del filtro PURITY C 0 % e PURITY C 30 % con regolazione fissa del by-pass
Cabezas filtrantes PURITY C 0 % y PURITY C 30 % con mezcla ajustada fija
Glowice filtrów PURITY C 0 % oraz PURITY C 30 % ze stałym obejsciem
Filterhoveder PURITY C 0 % og PURITY C 30 % med fast indstillet blanding
Головные часту сильстros capин PURITY C c bypass 0 % и сикробаньим by

Verschnitt 0% / By-pass 0% / By-pass 0% / Bypass 0% / by-pass 0% / mezcla 0% / Obejscie 0% / Blanding 0% / Bypass 0%

°dH (°KH) Recommended bypass settingPURITY C Quell ST - Filter capacity in litre
C25* C50C150 C300C500 C1100
40%367100025084167708311979
50%367100025084167708311979
60%367100025084167708311979
70%31485721503571607110268
80%2757501881312553138984
90%2446671672277847227986
100%2206001505250042507188
110%2005451368227338646534
120%1835001254208335425990
130%1694621158192332695529
140%1574291075178630365134
150%1474001003166728334792
160%138375941156326564492
170%129353885147125004228
180%122333836138923613993
190%116316792131622373783
200%110300753125021253594
210%105286717119020243423
220%100273684113619323267
230%96261654108718483125
240%92250627104217712995
250%88240602100017002875
260%8523157996216352764
270%8122255792615742662
280%7921453889315182567
290%7620751986214662478
300%7320050283314172396
310%7119448580613712319
320%6918847078113282246
330%6718245675812882178
340%6517644373512502114
350%6317143071412142054

*available only in Spain, France and Italy

Verschnitt 30% / By-pass 30% / By-pass 30% / Bypass 30% / by-pass 30% / mezcla 30% / Obejscie 30% / Blanding 30% / Bypass 30%

°dH (°KH) Recommended bypass settingPURITY C Quell ST - Filter capacity in litre
C25* C50C150 C300C500 C1100
430%508138634765774981516600
530%508138634765774981516600
630%508138634765774981516600
730%436118829794949841314228
830%381103926074330736212450
930%33992423173849654411066
1030%3058312086346458899960
1130%2777561896314953549054
1230%2546931738288749088300
1330%2356401604266545307661
1430%2185941490247442077114
1530%2035541390231039266640
1630%1915201303216536816225
1730%1794891227203834645859
1830%1694621159192532725533
1930%1604381098182331005242
2030%1524161043173229454980
2130%145396993165028044743
2230%139378948157526774527
2330%133361907150625614330
2430%127346869144324544150
2530%122333834138623563984
2630%117320802133222653831
2730%113308772128321813689
2830%109297745123721033557
2930%105287719119520313434
3030%102277695115519633320
3130%98268673111819003213
3230%95260652108318403112
3330%92252632105017853018
3430%90245613101917322929
3530%8723859699016832846

*available only in Spain, France and Italy

PURITY Finest C

Verschnitt- und Kapazitätstabellen / By-pass and capacity tables / Tableau de réglage by-pass et de détermination de la capacité / Bypass- en capaciteitstabellen / Tabelle del by-pass e della capacité / Tablas de mezcla y capacité / Tabele obejsć i wydajnosci / Blandings- og kapacitetstabeller / Tablina pécuρcob φильстра и nause tropek bypass

Filter Heads PURITY C 0% with fixed by-pass

TolOBhIe YacTHn fHbTPOB cepH N PURITY C 0% c KcHPOBaHHbIM bypass

The PURITY C1000 AC filter system has a filter capacity of 10.000 litres, irrespective of carbonate-hardness and the bypass proportion setting. All the intake water is filtered.

PURITY Fresh C

The PURITY Fresh C50 filter system has a filter capacity of 12.000 litres, irrespective of carbonate-hardness and the bypass proportion setting. All the intake water is filtered.

Note: All stated capacities were tested and calculated based on standard application and machine conditions. This information may vary according to external influencing factors (for example, fluctuating water quality and/or machine type).

1 Begriffsübersicht

1 Definition of Terms

All filter head types:

① Filter head
② Locking handle
③ Water outlet (G3/8" or JG8)
Water inlet (G3/8" or JG8)
⑤ Wall mounting bracket
⑥ Filter cartridge
⑦ Protective cap
⑧ Flush valve
Flush hose

Additionally for filter head types PURITY C 0-70%

10 By-pass setting
① Flush valve with slider

Additionally for filter head types PURITY C with John Guest connection:

② Safety clips

2 General Information

2.1 Function and Application

PURITY C is a filter system specially designed by BRITA for use in catering to ensure constantly high water quality for individual customer applications as well as reliable and simple operation.

The unique IntelliBypass ensures a constant by-pass proportion of water for the entire usage period, irrespective of the volumetric flow of the terminal equipment used. The result is consistently high water quality specially tailored to the requirements of the application and the local water conditions.

By reliably locking the filter cartridge in the filter head and controlling the water flow, the innovative locking handle ensures simple and reliable operation.

The food grade quality provided by the BRITA PURITY C filter system has been tested and confirmed by independent institutes. Product-specific certifications are located on the label and also at www.brita.net.

2.1.1 PURITY C Quell ST

PURITY C Quell ST filter cartridges reduce the carbonate hardness in drinking water, thus preventing scale deposits in the downstream terminal equipment. Depending on the by-pass setting, calcium, magnesium and metal ions can be selectively removed from the drinking water during the flow process. In addition to cloudiness and organic pollutants, the filter material also reduces the level of substances impairing smell and taste, such as chlorine residues in the filtrate and in the by-pass water.

Typical areas of application for PURITY C Quell ST are coffee and espresso machines, hot and cold drink vending machines as well as combi ovens and conventional ovens.

2.1.2 PURITY Finest C

The PURITY Finest C filtrate helps to produce the unique coffee aroma - especially in espressos - and allows the body of the coffee to develop. The characteristics of the coffee crema are experienced in their full intensity.

The PURITY Finest C filter cartridges reduce the total hardness in drinking water, thereby avoiding limescale and gypsum deposits in the downstream appliance.

Calcium, magnesium and metal ions are selectively removed from the drinking water using the flow method.

The filter material not only reduces cloudiness and organic pollutants, but also the level of substances that impair the smell and taste, such as chlorine residues in the filtrate.

The PURITY Finest C is typically used in coffee and espresso machines.

Caution: The PURITY Finest C is not suitable for use with combi ovens and conventional ovens. Operation is not recommended in combination with domestic water-softening systems. PURITY Finest C cartridges must be operated with a bypass setting of 0% .

2.1.3 PURITY Fresh C

In addition to minimising cloudiness and organic pollutants, PURITY Fresh C filter cartridges reduce substances that impair taste and smell in drinking water, such as chlorine and chlorine compounds.

Particles that impair system functionality are trapped. The PURITY Fresh C filter system was developed especially for enhancing the taste and freshness of water for coffee, espresso and vending machines.

2.1.4 PURITY C AC

The PURITY C AC filter cartridge reduces cloudiness, organic pollutants as well as the level of substances impairing smell and taste, such as chlorine residues. The filter material retains particles down to a size of 0.5 m .

Typical areas of application for PURITY C AC are vending machines and on-tap watercoolers.

2.2 Warranty Provisions

The PURITY C filter system is subject to the statutory warranty of 2 years. A warranty claim may only be asserted if all instructions in this manual are followed and observed.

2.3 Storage/Transport

Adhere to the ambient conditions for storage and transport detailed in the technical data (Chapter 9).

The manual should be seen as part of the product and kept for the whole service life of the filter system and passed on to subsequent owners.

2.4 Recycling/Disposal

The packaging material is suitable for recycling and can be reused. Please dispose of all materials in accordance with local regulations.

BRITA takes back used filter cartridges for recycling at the addresses listed on the back of the cover, or the cartridges can be disposed of according to local regulations.

If you decide not to return the filter cartridges, please dispose of all materials in accordance with local regulations.

3 Operating and Safety Instructions

3.1 Qualified Personnel

Installation and maintenance of the filter system shall only be carried out by trained and authorised personnel.

3.2 Correct Use

Perfect and safe operation of the product is subject to the installation, use and maintenance described in this manual. Only use filter cartridges intended for use with your filter system.

3.3 Liability Exclusion

Installation and cartridge exchanges must be performed precisely in accordance with the instructions in this manual. BRITA shall not be held liable for any damage, including subsequent damage, arising from the incorrect installation or use of the product.

3.4 Specific Safety Information

  • Water used as intake water for the PURITY C water filter system must be of drinking water quality. The BRITA water filter system is only suitable for cold water use within the water intake temperature range stated in Chapter 9.
  • If there are official instructions to boil tap water, the filter system must be decommissioned. When the requirement to boil water comes to an end, the filter cartridge must be replaced and the connections cleaned.
  • For hygiene reasons, the filter material of the cartridge is subjected to a special treatment with silver. A small quantity of silver, which is harmless to health, may be released into the water. This is in compliance with the World Health Organisation (WHO) recommendations for drinking water.
  • It is generally recommended to boil tap water for certain groups of people (e.g. people with weakened immune systems, babies). This also applies to filtered water.
  • Note for people with kidney disease or dialysis patients: During the filter process the potassium levels may increase slightly. If you suffer from kidney disease and/or have to stick to a special potassium diet, we recommend you consult your doctor beforehand.
  • The water filtrate is classified in Category 2 according to EN 1717.
  • BRITA recommends not to decommission the filter system for long periods. If the BRITA PURITY C filter system is not used for several days, we recommend that the filter system be flushed with the volume of water indicated in the table below.
Filter cartridge Flushing volume after2-3 days stagnationFlushing volume after 4 weeks stagnation
PURITY C25* 1.4 litres 14 litres
PURITY C50 2 litres 20 litres
PURITY C150 3 litres 30 litres
PURITY C300 6 litres 60 litres
PURITY C500 10 litres 100 litres
PURITY C1100 18 litres 180 litres
PURITY C1000 AC 1 litre 10 litres

*available only in Spain, France, Italy

  • The filter system must not be opened or dismantled during operation. The filter cartridge must not be opened.
    Production date
Production code - filter head - example: H 3375 01381
3Production year, this example: 2013
37Production week, this example: calendar week 37
5Production day from Monday (1) to Friday (5); this example: Friday
01381Serial identification number
Production code filter cartridge – example: B3224350010
3Production year, this example:2013
22Production week, this example: calendar week 22
4Production day from Monday(1) to Friday (2), this example: Thursday
35Internal Identification No. of filter medium this example: No. 35
0010Consecutive number of the filter cartridge, this example the tenth cartridge; reset the day changes

3.5 Technical Safety Assembly Instructions

  • The appliance in which the filter is used must be free of limescale and gypsum deposits prior to installation.
  • Protect the filter system from sunlight and mechanical damage. Do not assemble near sources of heat and open flames.
  • A stop valve must be installed before the filter system inlet hose.
    If the water pressure is greater than 8.6 bar, a pressure reducer must be installed in front of the filter system.
  • When choosing the material for parts that come into contact with water after the BRITA filter system, it is important to remember that, due to the process, decarbonised water contains free carbon dioxide. For this reason, only materials that are compatible with free carbon dioxide must be used. We recommend the use of BRITA hoses.
  • All parts must be installed in accordance with the country-specific guidelines on the installation of drinking water facilities.

4 Installation

Caution: Prior to installation, read the technical data (Chapter 9) and the operating and safety information (Chapter 3). After storage and transport below 0^ , the product must be stored in the open original packaging for at least 24 hours before it is commissioned at the stated ambient temperatures (Chapter 9) for operation.

4.1 Assembling the filter head, water connection

A

  • Close the water intake and switch off the power supply to the end device
  • Fit the wall mounting bracket ⑤ in the intended position

B

Caution: When fitting the bracket, note the installation dimensions, bending radii of the hoses and dimensions of the accessories (e.g. BRITA FlowMeter). When using the wall mount, install vertically only! The PURITY C1100 cannot be installed using the wall mounting bracket.

C

  • Fit the hoses to the water inlet "IN" ④ and outlet "OUT" ③ on the filter head ①.
  • Use flat seals for G3/8" connections. For John Guest connections, use hoses with a diameter of 8 mm. In the case of John Guest connections, the two safety clips ⑫ must be inserted after fitting the hose.

Caution: The tightening torque at G3/8" connections must not exceed 14 Nm! Only hose connections with flat seals may be used, as hoses with conical screw connections damage the connections on the filter head and invalidate any warranty claim! We recommend the use of BRITA hoses.

D

  • When using PURITY C 0–70 % filter heads, check by-pass setting (set to 30 % at the factory) and if necessary adjust this setting to the local carbonate hardness (PURITY C Quell ST) (chapter 4.2).
  • Lock the filter head ① in the wall mounting bracket ⑤.

4.2 By-pass setting for and capacity of PURITY C 0-70 % filter heads

  • Determine the carbonate hardness (for PURITY C Quell ST filter cartridges) or total hardness (for PURITY Finest C filter cartridges) of the local water by performing the BRITA carbonate hardness test or BRITA total hardness test. Alternatively, your local water supplier will be able to provide information on the local water hardness.
  • Determine the by-pass setting and capacity in line with the application and the carbonate and/or total hardness identified using the by-pass and capacity table (pages 2-6).
  • Then turn the by-pass setting to the identified value.
    To ensure precise and continuous control of the degree of filter cartridge exhaustion, it is recommended to install the BRITA FlowMeter 10-100 A.
    Note: With PURITY C AC, PURITY Finest C and PURITY Fresh C filter cartridges, all of the intake water is filtered. The filter cartridge can be used with filter heads that have a variable or fixed by-pass. The by-pass that may be set in the filter head is not taken into account.

4.3 Inserting the filter cartridge

  • Pull the flap of the protective cap ⑦ upwards and remove the protective cap.

Note the next exchange date in the date field on the filter cartridge resp. on the
FilterManager app 6.
- Insert the filter cartridge ⑥ in the filter head ① in a vertical position.

Caution: The filter cartridge can only be inserted when the locking handle is open.

Make sure that the filter cartridge is positioned correctly.

  • Turn the locking handle ② until you feel it engage.

4.4 Commissioning

  • Open the water intake and switch on the terminal equipment's power supply.
  • Operate the flush valve 8 and flush the filter system until the filtered water runs clear and without bubbles. At least two empty filter cartridge volumes must be flushed (Chapter 9).

Note: When bleeding/flushing, catch water emerging from the flush hose 9 in an appropriate container.

  • Check system for any leaks.

5 Changing the Filter Cartridge

The PURITY C filter cartridge must be replaced once the stated capacity has been reached (see Chapter 6), in accordance with manufacturer's specifications or no later than 12 months after commissioning, whichever occurs first.

Caution: When changing a filter, examine all remaining parts carefully! Faulty parts must be replaced and contaminated parts should be cleaned! Read the operating and safety information (Chapter 3) before changing the cartridge. After storage and transport below 0^ , the product must be stored in the open original packaging for at least 24 hours before it is commissioned at the stated ambient temperatures (Chapter 9) for operation.

Note: When the locking handle is open, the water supply to the cartridge is interrupted and short-circuit operation with direct water flow from the water inlet 4 to the water outlet 3 is possible (if necessary, close water intake and switch off power supply to the terminal equipment).

  • Open locking handle ②.
  • Activate the flush valve ⑧ and depressurise the system.
  • Remove exhausted filter cartridge ⑥ from the filter head ①, bearing in mind the weight of the cartridge.

Note: The filter cartridge can be pivoted by 90^ in the wall mounting bracket for easy removal.

  • Perform the steps described at 4.3 and 4.4.

6 By-Pass and Capacity Tables

The capacity tables for the PURITY C Quell ST and PURITY Finest C filter systems are provided on pages 2-6.

The PURITY C AC and PURITY Fresh C filter systems have a filter capacity of 10,000 and 12,000 litres respectively, regardless of the carbonate hardness and the by-pass set. All intake water is filtered.

Note: The stated capacities were tested and calculated based on standard application and machine conditions. This information may vary according to external influencing factors (for example fluctuating water quality and/or machine type).

7 Repair

Regularly check the filter system for leaks. Regularly check the hoses for kinks.

Bent hoses must be replaced.

The complete filter system must be replaced in rotation after a maximum of ten years.

The hoses must be replaced in rotation after a maximum of five years.

Caution: Before replacing filter systems or hoses, read the technical data (Chapter 9) and the operating and safety information (Chapter 3).

Regularly clean the outside of the filter system with a soft, damp cloth.

Caution: Do not use any abrasive chemicals, cleaning solutions or astringent cleaning agents.

8 Troubleshooting

8.1 No water flow

Cause: Water intake closed.

Troubleshooting: Open the water intake at the upstream stop valve or by closing the locking handle ② on the filter head ①

8.2 No or low water flow in spite of open water intake

Cause: Mains pressure too low.

Troubleshooting: Check mains pressure. If the fault persists, check the filter system and filter cartridge and replace if necessary.

Cause: Filter head not mounted in direction of flow.

Troubleshooting: Dismantle filter head and install in direction of flow (Chapter 4).

8.3 Leak

Cause: Screwed connections not fitted correctly.

Troubleshooting: Check mains pressure. Check all screwed connections and mount according to Chapter 4. If the fault persists, replace filter system.

9 Technical Data

PURITY C filter system with filter cartridge
Operating pressure 2 bar to max. 8.6 bar
Water intake temperature 4 °C to 30 °C
Ambient temperature duringoperation 4 °C to 40 °C
storage/transport -20 °C to 50 °C
Water inlet and outlet connection G3/8" or John Guest 8 mm
Filter systemC25 Quell STC50 Quell STC150 Quell STC300 Quell STC500 Quell STC1100 Quell ST
Flow rate with 1 bar pressure loss160 l/h160 l/h145 l/h140 l/h140 l/h150 l/h
Nominal flow 30 l/h 60 l/h 60 l/h 60 l/h 100 l/h100 l/h
Pressure loss at nominal flow0.1 bar0.25 bar0.25 bar0.25 bar0.5 bar0.5 bar
Empty filter cartridge volume0.85 l1 l1.9 l2.9 l5.4 l8.7 l
Weightdry0.8 kg1.0 kg1.8 kg2.8 kg4.6 kg7.7 kg
wet1.2 kg1.6 kg2.8 kg4.2 kg6.9 kg12.5 kg
Comparable capacity*170 l435 l1,278 l2,066 l4,125 l8,670 l
Dimensions (Width/Depth/Height)Filter system (filter head with filter cartridge)119 mm/108 mm/219 mm119 mm/108 mm/268 mm117 mm/104 mm/419 mm125 mm/119 mm/466 mm144 mm/144 mm/557 mm184 mm/184 mm/557 mm
Filter cartridge108 mm/108 mm/210 mm108 mm/108 mm/259 mm104 mm/104 mm/410 mm119 mm/119 mm/457 mm144 mm/144 mm/548 mm184 mm/184 mm/548 mm
Installed dimensions (vertical installation with wall mounting bracket)137 mm/130 mm/219 mm137 mm/130 mm/268 mm137 mm/128 mm/419 mm137 mm/136 mm/466 mm144 mm/148 mm/557 mm-
Operating positionHorizontal or vertical
PURITY C filter system with filter cartridge
Operating pressure 2 bar to max. 8.6 bar
Water intake temperature 4 °C to 30 °C
Ambient temperature duringoperation 4 °C to 40 °C storage/transport -20 °C to 50 °C
Water inlet and outlet connection G3/8" or John Guest 8 mm
Filter systemFinest C150Finest C500Finest C1100Fresh C50C1000 AC
Flow rate with 1 bar pressure loss145 l/h140 l/h150 l/h160 l/h140 l/h
Nominal flow60 l/h100 l/h60 l/h30-180 l/h**
Pressure loss at nominal flow0.25 bar0.5 bar0.25 bar0.2-1.4 bar**
Empty filter cartridge volume1.9 l5.4 l8.7 l1 l0.23 l
Weightdry1.8 kg4.6 kg7.7 kg0.7 kg0.5 kg
wet2.8 kg6.9 kg12.5 kg1.5 kg1.0 kg
Comparable capacity*-3,170 l---
Dimensions (Width/Depth/Height)Filter system (filter head with filter cartridge)117 mm/104 mm/419 mm144 mm/144 mm/557 mm184 mm/184 mm/557 mm119 mm/108 mm/268 mm109 mm/93 mm/238 mm
Filter cartridge104 mm/104 mm/410 mm144 mm/144 mm/548 mm184 mm/184 mm/548 mm108 mm/108 mm/259 mm88 mm/88 mm/231 mm
Installed dimensions (vertical installation with wall mounting bracket)137 mm/128 mm/419 mm144 mm/148 mm/557 mm-137 mm/130 mm/268 mm137 mm/120 mm/238 mm
Operating positionVerticalHorizontal or vertical
Nominal capacity----10,000 l
Chlorine reduction DIN EN 14898---->90%
Chlorine reduction NSF 42----Class I (50%)
Particle retention NSF 42----Class I (0.5 μm)
  • Comparable capacity as defined in DIN 18879-1:2007: The comparable capacity is a standardised parameter to facilitate comparison of different filters. The comparable capacity is determined under extreme conditions. The usable capacity in practical operation is higher than the comparable capacity and may vary greatly depending on the usage conditions.
    ** Working flow range and associated pressure loss: 30-180 l/hr/0.2-1.4 bar

Information for Australian market / PERFORMANCE DATA SHEET

Manufacturer Seller

BRITA GmbH BRITA Water Filter Systems

Heinrich-Hertz-Str. 4 Distributors Pty Ltd

65232 Taunusstein Unit 522 Narabang Way

Germany Belrose, NSW, 2085

+49-(0) 6128-746-0 Australia

Tel +61 2 9486 4200

Fax +61 2 9486 4222

www.britacom.au

PRODUCTS

Water Filter Systems

PURITY C50 Quell ST PURITY C150 Quell ST PURITY C300 Quell ST

Filterhead 0-70% G3/8" Filterhead 0% G3/8" Filterhead 30% G3/8"

PURITY C500 Quell ST PURITY C1100 Quell ST PURITY C1000 AC

PURITY Fresh C50

PURITY Finest C500

USE GUIDELINES

  • Minimum operating pressure: 2 bar
  • Do not allow exposure to temperatures below 4^
  • Nominal flow rates: PURITY C50 Quell ST (60 l/h), PURITY C150 Quell ST (60 l/h), PURITY C300 Quell ST (60 l/h), PURITY C500 Quell ST (100 l/h), PURITY C1100 Quell ST (100 l/h), PURITY Fresh C50 (60 l/h), PURITY Finest C500 (100 l/h)
  • This system must be installed according to local plumbing codes on the cold water line.
  • Replacement Cartridges

PURITY C50 Quell ST Pack 1, PURITY C150 Quell ST Pack 1, PURITY C300 Quell ST Pack 1, PURITY C500 Quell ST Pack 1, PURITY C1100 Quell ST Pack 1, PURITY C1000 AC Pack 1, PURITY Fresh C50 Pack 1, PURITY Finest C500 Pack 1

  • This system requires regular replacement of the filter cartridge to maintain proper operation. Varying scale, chlorine, sediment, or organic substance levels may affect replacement frequency.
  • Be sure to change the filter cartridge at least as indicated in the capacity table (refer to your Instruction Guide) or annually, whichever occurs first, or whenever you detect a change in taste, odour, or a decrease in flow.
  • Please ensure that a backflow prevention device, meeting the requirements of AS/NZS 3500.1, is installed on the water supply inlet to the filter unit
  • Caution: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

SUBSTANCE REDUCTION

The above listed Water Filter Systems have been tested and certified under NSF/ANSI 42 for reduction of chlorine, taste and odour. The performance of this product has been verified and substantiated as the test data summarised below indicates. These substances may not be in your water.

Test Data for PURITY C50 Quell ST

SubstanceGuidelinesAverage Influent ConcentrationMaximum Effluent ConcentrationMinimum Percent RemovalAverage Effluent ConcentrationAverage Percent Removal
ChlorineNSF/ANSI 422.11 mg/l0.40 mg/l81.0%0.24 mg/l88.7%

*Test Data for PURITY C150 Quell ST

SubstanceGuidelinesAverage Influent ConcentrationMaximum Effluent ConcentrationMinimum Percent RemovalAverage Effluent ConcentrationAverage Percent Removal
ChlorineNSF/ANSI 422.11 mg/l0.40 mg/l81.0%0.24 mg/l88.7%

*Test Data for PURITY C300 Quell ST

Substance Guidelines AverageInfluent ConcentrationMaximum Effluent ConcentrationMinimum Percent RemovalAverage Effluent ConcentrationAverage Percent Removal
ChlorineNSF/ANSI 422.11 mg/l0.40 mg/l81.0 %0.24 mg/l
88.7 %

Test Data for PURITY C500 Quell ST

SubstanceGuidelines AverageInfluent ConcentrationMaximum Effluent ConcentrationMinimum Percent RemovalAverage Effluent ConcentrationAverage Percent Removal
ChlorineNSF/ANSI 422.1 mg/l0.31 mg/l85.2%0.25 mg/l88.6%

**Test Data for PURITY C1100 Quell ST

Substance Guidelines AverageInfluent ConcentrationMaximum Effluent ConcentrationMinimum Percent RemovalAverage Effluent ConcentrationAverage Percent Removal
ChlorineNSF/ANSI 422.1 mg/l0.31 mg/l85.2%0.25 mg/l88.6%

Test Data for PURITY C1000 AC

Substance Guidelines AverageInfluent ConcentrationMaximum Effluent ConcentrationMinimum Percent RemovalAverage Effluent ConcentrationAverage Percent Removal
ChlorineNSF/ANSI 422.1 mg/l0.05 mg/l97.4 %0.05 mg/l97.6 %

Test Data for PURITY Fresh C50

Substance Guidelines AverageInfluent ConcentrationMaximum Effluent ConcentrationMinimum Percent RemovalAverage Effluent ConcentrationAverage Percent Removal
ChlorineNSF/ANSI 422.0 mg/lND (0.05 mg/l) (not detectable)97.4 %ND(0.05 mg/l) (not detectable)>97.5 %

Test Data for PURITY Finest C500

Substance Guidelines AverageInfluent ConcentrationMaximum Effluent ConcentrationMinimum Percent RemovalAverage Effluent ConcentrationAverage Percent Removal
ChlorineNSF/ANSI 422.0 mg/lND (0.05 mg/l) (not detectable)97.4 %ND(0.05 mg/l) (not detectable)>97.5 %
  • Values calculated on basis of the C50

** Values calculated on basis of the C500

Testing Conditions:

Flow Rate: 0.25 GPM pH: 7.5 + / - 0.5

Pressure: 60 + / - 3 psgi Temperature: 20 + / - 3^

Refer to your Instruction Guide for more specific product and warranty information and to avoid contamination from improper handling and installation. Performance will vary based on local water conditions. The substances reduced by this product are not necessarily in your water.

Buyer's Signature

Date

Seller's Signature

Date

This appliance meets the domestic water treatment appliance Standards AS/NZS 3497 and AS/NZS 4348 for the following water treatment process:

ClassTreatment typeFunctionPass
IMicrobiological StatusBacteriostaticWill stop bacteria increasingN/A
II Microbiological Treatment
Bacteria removalVirus removalProtozoa removalWill remove or inactivate bacteriaWill remove or inactivate virusWill remove or inactivate Crypto-sporidium and GiardiaN/AN/AN/A
IIITurbidity and particulate reductionReduces cloudinessN/A
IVTaste and odour reductionReduces tastes and odours
VChemical treatmentDecreases chlorine

LEGEND:

=pass

N/A = Not Applicable

1 Éléments

DOnonHnTeJIbHaonZnIg rONOBhIX YacTeNΦnBtpoB cepm
PURITY C c coeHHeHnMy John Guest:
12ΦHKcpyUOuNE KNNcbI

2 Obuine cBeHnna

2.1 Ha3naYeHne n o6JaCTn npImeHeHHa

CnCTemaФиьТрацИN PURITY C pa3pa6oTaHa KOMnaHnei BRITA cneuaJIbHoДЯ npIMeHnB INdycTpIN OSeCTBeHHOrO NITaHnI DЯ OBeceNeHnI NOCToHNO BbICOKOr KoYeCTBa BOblY INDINuDAyIbHbIX NOTpe6nteJe. 3Ta CnCTema XapaKTePn3yeTcR IpocToTOI N HaDeJXHOCTbIOB 3KcIIpyatauN.

YHnKaJIbHOe ycIpoIcTBo IntelliBypass o6ecneuBaet nocToHHyIO npOnOpzIO CMeunBaHn BObl B TeueHne Bcero cPoka 3KcIIpyatauINΦNbTpA, He3aBNCIMO OT obema paCXoDa BObl NOTpe6JIouUIM M obopyuOBAHnEM. B pe3yIbTaTe 3TOrO nOdepXnBaETCBAICOKoe kaueCTBO BObl, CpeZnAJIbHo aADANTIpOBaHHOe K yCNOBnM npImHeHn I COCTABY MEcTHOH BObl.

HnHOaONHna 6nOKpyoJaa pyKoTka fNbTpa oEscneuNbaet npocToTy n 6e3OnacHocTb 3KcIpyataun 6NaOapra HndexHo hKcaun CMeHHoro KapTpNJaB a RTOOBHO uactn fNtbp Ta n ynpabNeHIO NOTOKOM BODbl.

CoBmecTmocTb cnTeMbI pInbTaqun BRITA PURITY C c nIeBbIMn npOdyKTamn npOBepena I NOdTBePjdeHa He3aBncMbIMn INCTuTyTam. CepTuΦnKauaN 3dEJIy yka3aHa Ha 3TNKeTke, a TAKKe Ha caTe www.brita.net.

2.1.1 Φилвтрbl PURITY C Queill ST

Фиьтуюше картуджи PURITY C Quell ST снжаот karбогашиу ќестоь (KH) пптбевоь BODОрвОДнОВ ВОДы,празOTВраця Tem caMbIM obpa3OBaHne n3BecTKOBbIX OTLOJOHeN B NOTpe6JIHOUeM OБOPyOBOAHIN. B 3aBnCmOCTn OT hAcTpoKn bypass noHbI KaIbUЯ, marHnI N MeTaNIOB MOrY T 6bITb Bbl6OpOHy ydaIeHbI n3 ПИТБЕВОВ BОДы B npOceCE φИЛТРaциN.

ПOMМО 3ТОВО ФИЛБТРУЮДМ MaTePиАЛ CHИЖаEТ MYTHOCТь, CODEрЖaHne OprAHUYeCKNx 3aRpy3HeHn, a TAKKe IprIMeCeI, yXyДшAOJOUX Bkyc N 3aJax, TAKNX KAK XJOp, BФИЛbTpate n B BOde bypass.

TINHbIMN oBnactaMn npimeHeHnaPbTOB PURITY C Quell ST ABnIOTcKoPeMaunHbl, BeHNrROBbIe aBTOMaTbI dJIa XOJOnHbIX n ropauX HAnNTKOB, a TaKKe napOKOBekTOMaTbI INHbIe CTmepbl.

2.1.2 Φильtp PURITY Finest C

ФиьтpoBaHHa BODa ФиьТpa PURITY Finest C, NO3BOJЯET nprirotOBtB KoPe c yHnKaJIbHbIM apomatom (ocO6eHNo 3cnpceco), n rIy6okm noJIHOteMbIM BKycOM. KpeMa Ha KoPe noJIyuaOTcR pIoTHbIe N HacblIeHHbIe.

Фиьт PRUITY Finest C yMeHbShaet obuJIO JecTKoCTb (GH) nTbeBOB BODonpoBOHOBbl, Tem cambIM NCKIQUaR BO3MOXHOCTb Oba3OBaHnR IN3BeCTKObBIX, INrncobbIX OTIOKeHn B notpe6JIouOeM o6OpyIDOBaHn.

B npocece npoteKaHn 3 nntbeBoi BoDbI n3bnpaTeJbHO n3BJIeKaIOTcN OHb KaJIbCnI N MaHn, a TaKKe IOHb MeTaJnla.

Bolee toro, Maepn an pfunbtpa cHxkaet He ToIbKO MyTHocTb n CoedePkaHne opraHnuecknx 3arpa3HeHn, Ho n ypoBeHb BeIeCTB, KOTOpbIe yXyDHaHT BKyc n 3anax BoIb, TAKNX KaK OCTaToCHbI Xnop, B pfunbtpaTe n B BoIe bypass.

Фильtp PURITY Finest C obiyuH noJb3yeTcЯДя KoFemaunH.

BHMHHe: pNbTp PURITY Finest C He noDxOaNT dIy IcNoIb3oBaHna C napOKOBekTOMaMn INHbIMn CTmepamn. He peKomeHdyeTcra KcNpyataunr qNlbtpa c nCnoIb3oBaHne M Bobl OT yMaRHTeJI (T.e. ycTaHOBka nocNe yMaRHTeJI). KapTpNDXn PURITY Finest C HAdnEeHT 3KcNpyATnpOBaTB C hAcTPOkOcmseWbAHn 0 %.

2.1.3 Φильтг PURITY Fresh C

Финьт PURITY Fresh C yмeньшаeТ муTHOCь, содерхаHne oprанчecKx 3aRpy3HeHn, a TaKke BeUeCTB, уxuДшaIOUx BKyc N 3aIax ПИТbeBOВ BODbl, TAKX KaK XlOp I erO COeDINHeHn.

Yactnbl, KOTOpbIe yxuHaOT cyHKunHOaHbHocTb NOTpe6JIOUeO 6OpyDObAHn, 3aepKNaHTc. Htp-cntema PURITY Fresh C 6bIpa3pa6oTaHa cneuaIbHo dIyIyUeHn Bkyca n CBExectn BObl Ira KoemauHH IN BEHNHROBbIX ABTomATOB.

2.2「apaHTnHbIe 06aTeJIbCTBa

HaФиltbpI cepH PURITY CpacnpoctpaHReTc npedycmOTpeHHa 3aKOHm rapaHTnCpOKOM OINrO.ΓapaHTnHbIe Tpe6OBaHnI npHIMaOTc TOnbKO npu ycNoBn CO6NIODeHnI ONb3OBaTeNm Bcex yka3AHn HacToJzero PykoBODCTBa.

2.3 XpaHeHne n TpaHcnOpTnpoBka

Co6IIOaIte yCIOBnXpaHEnn I TpaHCnOpTnpOBKn, yka3aHHbIe B pa3dJe 9 «TexHnueckne napaMeTpbl».

ДанhoePykoBoDcTBo no 3KcnnyaTaunn CneJyET paccMaTpNaBaTb KaK YacTb N3dEInn I XpaHnTb erO B TeueHne BCero Cpoka Cnyx6bl ΦnIbTp-CnCTeMbI, a B Cnyuae CMeHbI BnaJeBla - NepeDaTb erO cNeDuOuSeMy BnaDeNbU.

2.4пека /утлзця

YnakoBouHbIM MaTePnaJI npriOdoH IJI NOBTOpHO IOCNOJb3OBaHnIy. Bce MaTePnaJIbI DOJXHbI 6bITb YtINn3InPOBaHbIB COOTBeTCTBmC MeCTHbIM 3aKOHOdaTeJIbCTBOM. Otpa6oTaBUne CMeHHbIE KApTpIaIXn YtINn3InPyuTe, NoKaNyIcTa, corJaCHO MeCTHbIM HOpMaTUBHbIM npabUHaM.

3 HctpyKuHn no 3KcNpyatauHn 6e3onacHOCTn

3.1 KBaIInΦIuPObaHHbI nepcoHaJI

YCTAHOBKoI HnBtp-CnCTeMb I ee TexHnueckm O6cnykBaHneM DOJXKeH 3aHIMaTbcKOMTeHThbl N yNoJIHOMOeHHbI nepcoHaJ.

3.2 Правильна зацян

Be30Ka3Ha n 6e3oNaChA eKcNpyataun H3dJIy oBecnueNBaeTc npu yCNOBn co6JIOHeHn N3IOKeHHbIX B daHHOM PykoOcCTBe yka3aHn NO MOHTaKy, 3KcNpyataun IN TexHnueCKOMy 6cbnykBaHnIO. IcNoIb3yIte ToIbKO Te CMeHHbIe KapTpIaXn, KOToPbIe IpeDHa3HaueHbl dJa fNlbTp-CnCTEmbl.

3.3 OrpaHnueHne OTBeTcTBeHHOCTN

Ipn yctaHOBKe pnlbTp-cnCTeMb i 3aMeHe CMeHHoro KaptpnJa cNeJeYET B TOUHOCTn CO6JIHOdaTb yka3aHn DaHHoro PykoBoIDCTBa. KomnaHn BRITA He Hecet OTBeTcTBeHHocTb 3a yuep6 (B TOM YNCJIe KOCBeHHb), KOTOpB MoKET BO3HNKHyTb BCJeDCTBne HECO6JIIODeHn yKa3aHn NO MOHTaKy n EKCIIpyatauN.

3.4 CneuaJIbHbIe yka3aHnNo mepam 6e3OnacHOCTn

  • Дя сиьтсntem BRITA cneуet nCnoB3OBaTb BODonpoBOnHyO Body nITbeBOrO kaeeCTBa. Φиьтсntembl BRITA cepn PURITY C noDxOJaT K nCnoB3OBaHIO TOIbKO dЯ XoIoHOB BOdBi, ImeIoSei Tempeatypy B npdeJax DnaNa3OHa, yka3aHHoro B rnaBe 9.
    B Cnyuae noctynenno ounnaIbHoro yka3aHnO Heo6xmoCTN KINrTb BODonpoBDHyOBdyCneJyET BBIECTn n3 3KcIIpyataun CnCTemy pntpaun. Pocne OTMeHbI 3TOrO yka3aHnREo6xmo 3aMeHHTb CMeHHbIK KapTPnIX N OCHNTb COeHNHeHn.
    B COOTBETCTBUN C CAHITAPHBIMN HOPMAMN cHINbTpBI NOJLeKAT CNEUaJIbHOI IPOeDype 6pa6oTKn CEpe6pOM. B BOy MoKeT NOnactb He3HaHTeJIbHOE KOJIueCTBO CEpe6pa, yTO a6COJIOTHO 6e3OpOBBy IN COOTBETCTByeT peKOMeHdaCuaM BcEMnPHoj OprAHn3aunno OxpaHe 3dOpOBBy (BO3) nIITbeBOI BObl.
    Kak npabnlo, pekomehnyetc KINrTb BOOnpOBOHyo BDOy dIg ONpeJeHHbIX rpynn IIOdei (Haepmep, IIOu C Ocna6JIeHHbIM NMMyHHTeTOM, MNaDeHcbl). 3TO OTHOCTCn I K fNtBtpOBaHHo BOE.
    BnmaHIO IHOe C 3a6OJIeBAHNEM NOeK IIN dIaIIIN3bIX NaIeHTOB: B npOecce fNtpaun MOKeT He3HaHTeJIbHO IOBicITbcra CoepKaHne KaIIa. EcNI Bbl cTpaJaTe 3a6OJIeBAHNEM NOeK / INI DOJXHbI pIuDEpXINBaTbcra CNEuaJIbHOI KaIIeBOI DNeTBI, Mbl peKOMeHdyem PpeBapNTeJIbHO IpOKOHcyJIbTInpOBaTbcra C BpaQOM.
    ΦNJIbTpAT OTHOCHTcK KaTEROpu 2 corJaHcHO KnaCCnФkaCm EN 1717.
    BRITA pekomehnyet He BbIOHTb fIbTp-cnCTemy HaOIO r3 3KcNpyaTcu. Ecnn CnCTema fIbtpauu BRITA PURITY C He nCNoJIb3OBaIacb HeCKoJIbKO dHei, Mbl pekomehdyem npomblte ee COOTBeTCTByIOUIM OObemOM BoIby, yKa3aHHbIM B HHXeCNe dyUoJe Ta6NIue.

4.3 MoHTaK cMeHHoro KapTpnuJa

BRITA Purity Fresh C - MoHTaK cMeHHoro KapTpnuJa - 1

  • Notaryt haKnaKy 3aunTHoro KOJNaUka ⑦ BBepX, CHaTb 3aunTHbI KOJNaUOK.
    BnHnte DaTy cNeIyUoSei 3aMeHbI KapTpNJa B CneuHaBHOe NoJe Ha
    fNbtpyUoEiM KapTpNJa E IIN COOTBeTCTBeHHO B MObHOM npJIOKeHH
    FilterManager 6.
    BCTaBbTe CmEHbI KApTpNIX 6 B rOIOBHyIO uactb cHJIbTpa 1 BepTnKaJIbHO.
    BHMaHHe: KapTpNIX BO3MOXHO yCTaHOBNTb TOJIbKO TOrda, KOrda 6NoKIpUoJyA pykoRTka 2 Ha rOIOBHO uACTn cHJIbTpa OTkpblTa.
    Tenepb noBepHnte 6JokpyuOyU pyKoAry ② do ynpa.

4.4 BBoD B 3KcNlyaTaUko

BRITA Purity Fresh C - BBoD B 3KcNlyaTaUko - 1

  • OtkpoTe IoIauy BoIbI BkJIouHte 3JIeKtpOnuTahne Ntpe6JIOUeO obOpdyObaHn.
  • Pn NOMOUI npOMbIOUHO KIanaHa 8 CInBaIte BOy u3 fNtpa Do Tex nop, noka OTfNtpoBaHHa BOda He cTaHET npo3paHOn I6e3 ny3bIpKOB. No kpaHe Mepe, DBA OBeMa NyCTORO KapTpua (rnaBa 9) HxKHO CnITb. PnmeuHne: npOMbIOUHbI uHaH 9 NOMeCTnte B KaKyIO-Ni6o EMKocTb COOTBEcTBByIOUeO pa3Mepa dIra CInBa BObl.
  • Поверпесильтссему на пpeДмет поTeчek.

5 3aMeHa cMeHHoro KapTpNiJka

3aMeHy cMeHHbIX KapTpndJKei PURITY C cneJeT npOn3BODntb nocIe BbIpabOTkn (nCToUeHn) erO pecypca (rnaBa 6), B COOTBeTcTBnC TexHnueCKmN ycNoBnMn npOn3BODnteN nIIH He no3dHee, yem uepe3 12 MeceB nocIe BBOda B 3KcPnyaTuIO, B 3aBNCIMOCTN OT TORO, KaKoe ycNoBne 6yDeT DOCTNRHyTo paHbWe.

BhimaHne: npn 3aMeHe CmEHoro KapTpndka TuaTeNbHO o6cneDyIe BCE ocTaNbHbIe DeTaNn PhnbTpa! DepeKTHbIe cJeDyET 3aMeHntb, 3aRpy3HeHHbIe cJeDyET noocntlb. Ipeed 3aMeHoi npIMnte BO BhimaHne yka3aHnno OeknPyatauun N be3oNaChocTn (rnaBa 3). Nocne xpaHeHn u TpaHCnpTnpOBKn npn TempepaType Hxke 0^ cJeDyET BbIepXaTb n3deJIne B OTkpblToN 3aBOdckoyn ynakobke He MeHee 24 Yacob nepeD BBOdom B ekCnPyatauU npn TempepaType OkpykaIouee CpeDbI, yka3aHHoB rnaBe 9 «TexHueckne napaMeTpbI».

PpimueaHne: npo OTkpBTo6IOKnpyuOe pyKoTke nepeKpbBaetcnoDa BODbIB CMeHHbIKapTpNk. Pnp 3tOM pbltp pa6oTaET B peXmE KOpOTKO kpyra C npMbIM NOTOKOM BOblYepe3 rONOBHy OacTh b pnlbTpa OT BXOda ④ KBxOdy ③ .Pnp Heo6xoJMoCTn nepeKpoTeNoaCyBObl IN BbIKIOUHTe 3JIeKTPoNTaHne NOtpe6nIoUero o6OpydoBaHna.

  • OTKpoTe 6nokpyuOyU pyKoAry ②.
  • AktiBnyTe (HaKMITE) npOMbIOUHbI KJIaNaH BΦnIbTp-CnCTeMe.
  • I3BNeKInTe Otpa6oTabuM CMeHbI KApTpNJxK UTO NcNOJb3OBAHHbI KApTpNJxT JxKeJeE HO

8,TEM CAMbIM CHN3NB daBHeHne

6 n3 rONOBHOn qactn cnBtpa 1, He 3a6bIB,

PnmeHne: KapTpNIXK MOxHO NOBepHyTb Ha 90^ B HacTeHHOM KpeINeHIN.

  • BbIIOJIHnTe DeIeCTBnIy, yKa3aHHbIe B rnaBax 4.3 n 4.4.

6 Ta6nucbI pecypcoB qnlbtpoB n Hactpoek bypass

clientservices@brita.co.uk

www.brita.co.uk

BRITA Italia S.r.l.

Via Zanica, 19K

1-24050 Grassobbio (BG)

tel: +39 (0) 35 19 96 46 39

fax: +39 (0) 35 19 96 22 56

professionalitalalia@brita.net

www.brita.it

BRITA GmbH

Offic e Netherlands

PL-05-850OzarowMazowiecki

tel +48 (0) 22721 24 20

fax +48 (0) 22 721 24 49

brita@brita.pl

www.brita.pl

BRITA Iberia, S.L.U.

C/ Valencia 307 2^0 - 4^a

E - 08009 - Barcelona

Tel. +34 (0) 93 342 75 70

Fax. +34 (0) 93 342 75 71

ppd-es@brita.net

www.profesional.brita.es

BRITA Wasser

Filter-Systeme AG

Gassmatt 6

CH-6025 Neudorf/LU

Tel +41 (0) 41 932 42 30

Distributors Pty Ltd

Level 9, 123 Epping Road,

North Ryde, NSW, 2113, Australia

Tel +61 2 9486 4200

Fax +61 2 9486 4222

professional@brita.com.au

www.britacom.au

BRITA Purity Fresh C - Filter-Systeme AG - 1

Filter management app

Download our free of charge BRITA

Professional FilterManager app and

I get a reminder for your next fi Itern

exchange - automatically, wherever

you are.

For smartphone and tablets.

For more information please visit:

professional.brita.net/app

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : BRITA

Model : Purity Fresh C

Category : Water filter