VARIATION OF BODY FAT THROUGHOUT THE DAY Levels of body hydration, lifestyle and daily habits can inuence the detection of the percentage of body fat. A detection performed during the early hours of the morning will calculate a higher percentage of fat because after a long nights sleep, the body tends to be dehydrated. For a more accurate reading and in order to compare different detections it is recommendable to use the product at the same hour of the day and under the same conditions. Before measuring it is important to remember that: - The percentage could be lower after having taken a bath - The percentage could be higher after eating or drinking - Detections could be irregular during a woman’s menstrual cycle - The percentage of water in our body can be reduced after having been ill or after heavy physical activity, as these conditions make us sweat more than usual. WHAT IS THE PERCENTAGE OFWATER IN THE BODY? The percentage of water present in the human body corresponds to the quantity of liquids expressed in a percentage ,according to the total weight of the individual, and it is calculated using a particular scientic formula, also used by expert dieticians. It is important to know that the water inside our body performs a fundamental function and is in all tissue and body organs: approximately 50-65% of our body is made of water. Thanks to these scales it is possible to keep the percentage of water under control, which is fundamental for correct functioning of our body. The percentage value of water present in a healthy individual is as follows: WOMEN from 45-60% MEN from 50-65% VARIATION OF THE PERCENTAGE OFWATER THROUGHOUT THE DAY To obtain a reliable detection it is recommended to measure the percentage of water in the evening (before dinner) as hydration levels are more normal during this hour of the day. In any case, to relate various measurements it is always recommendable to respect established hours.The percentage of water tends to be lower if detected in the morning and this is because the body dehydrates during sleep and above all because during the night liquids tend to concentrate in the torso (whereas during the day thanks to the force of gravity they spread out in a homogeneous manner). Factors that tend to modify the percentage of water are: sleeping,6
eating and/or drinking, physical activity, having a bath, consumption of medicines, physical conditions and urination.
IMPORTANTWARNINGS AND SAFETY RULES
The values obtained by this body fatMonitor are indicative data that for no reason whatsoever should replace a doctor’s opinion. Do not forget: self-measuring means control, not diagnosis or treatment. Unusual values should always be discussed with your doctor. Under no circumstances should you modify the dosage of any medicine prescribed by your doctor. The scales should not be used by: - People with pacemakers or any other internal device as the weak electric signal could in fact interfere with correct functioning of the device. - People with oedema, osteoporosis or fever - People in dialysis - If taking medicine for cardiovascular problems - Pregnant women - Athletes that practise more than 10 hours of intensive training per week - People who have a resting pulse frequency that is equal to or below 60 beats per minute. Only use the scales for the intentions indicated in this instruction manual and exclusively for domestic use. Any other type of use is to be considered improper and therefore dangerous. Check that the appliance is whole and is not damaged before use. If in doubt, do not use the product and consult a specialised after sales centre. To not attempt to repair the product yourself, always go to a specialised after sales centre. To avoid any interference it is recommendable to use the product away from appliances with a strong magnetic eld. Never place the scales on wet or slippery surfaces. Never immerse the product in water and never put it away in a damp place. Always keep the product away from sources of heat, direct sunlight, cutting objects or similar objects. When the appliance is not used for a long time, it is recommendable to remove the battery as leaking of uids could damage the product. Also, seeing that the quality of batteries varies between models, the warranty does not cover damage caused by any possible leaking of uids. Never leave the product unattended when children are present and always put it away out of their reach. FEATURES Capacity: 180kg Division: 0.1kg Weight unit: kg / lb / st8
Height unit : cm Display LCD Battery: 1 x CR2032 (test battery is included) User No.: 10 Age range: 10-80 Fat grade indication : increment of 0,1 % Water grade indication : increment of 0,1 % Overload indication Battery replacement indication Instructions: Read through these user’s istructions carefully before using the machine. The scale are intended for personal use only and not for medical or commercial use. Always make sure that the machine is on a hard,at surface and only use it indoors. Operation: For weight only : The following scale turns on in response to pressure. .Step on the scale ; the display show your weight. and select the weight unit : kg/lb/st by the key placed near the battery compartment. Stand normally on the scale with your weight distributed evenly on your two legs .Wait until the scale stabilizes your weight after the number on the display ashes twice. The scale will be auto off if no further using after few seconds . For weight , body fat percentage and body uid percentage: Press the SET key for seconds to set your persnal data When the screen shows “P1” Choose one of the memory slots 0-9 using the “ or ” key ,When the code number ashes on the screen and once you reach your target number, please press “SET” to conrm. (The scale can store data for 10 people) Then to choose Male or Female using the “ or ”key ,when the gender symbol ashes on the screen and then press “SET” to conrm . Then press “ or ” key to reach your target age (10-80) , when“AGE” and the number ashes on the screen and then press “SET” to conrm . Then press “ or ” key to reach your target height (100-240cm) when the number ash on the screen and then press “SET” to conrm. Finally, the screen will shows data of “height” & “Age” which been alrady settled ,and also with 0.0kg . Carry out the above steps to measure your body weight , body fat percentage and body uid percentage:8
Step on the scale gently and keep your bare feet in touch with the electrodes .Stand still and erect to get your weight measured and your body fat ,Fluid percentage will be displayed respectively on the screen within seconds . These results will be repeated for seconds and the scale will be auto off if no further using. Values for the percentage of body fat Age Woman Man Slim Normal Lighty over- weight Over-weight Slim Normal Lighty over- weight Over-weight 10-16 < 18% 18-28% 29-35 % > 35% < 10% 10-18% 19-23 % > 23 % 17-39 <20% 20-32 % 33¬38 % >38 % < 12 % 12-20 % 21-25 % >25 % 40-55 < 23 % 23-35 % 36-41 % > 41% <13 13-21 % 22-26 % > 26% 56-80 < 24% 24-36% 37-42 % > 42% <14% 14-22% 23-27% >27% Values for the percentage of body uid: Age Woman Man Low Normal High Low Normal High 10-16 57% 57-67% 67% 58% 58-72% 72% 17-39 47% 47-57% 57% 53% 53-67% 67% 40-55 42% 42-52% 52% 47% 47-61% 61% 56-80 37% 37-47% 42% 42% 42-56% 56% Error message / maintenance: “EEEE” appears in the display when the scale are overloaded “LO” appears on the display when the batteries need to be replaced. The supplied batteries are for trial use only and they may have a shorter life. “Err” appears on the display when the measurement cannot be carried out correctly Tip: Dry your feet again and try to stand as still as possible. Attention: Please take off shoes and socks and keep your bare feet in touch with the electrodes when taking body fat ,uid ,percentage measurement. The glass platform may be pretty slippery when wet ,thus please make sure both the glass and your feet are dry before use . Please use soft tissue with alcohol or glass cleaner to clean the surface if it is dirty. No soap or other chemicals.Keep it away from water,heat and extrem coldness. The scale is high precision measuring device.Never jump or stomp on the scale or disassemble it and please handle it carefully to avoid breaking when moving it.10
The scale is for family use only and not situable for professional use. Body fat ,Fluid rates measured only.You should consult a doctor when you undertake any diet or exercise program. Please check the batteries if the scale malfunctions ,Change new batteries if necessary .For other problems,Please contact the local dealer or our comoany directly by phone or E-mail. Caution: Persons with pacemakers should not use this product. Persons with metal implants will be unable to abtain accurate measurement. To ensure accuracy ,We suggest you take measurement at a xed time every day (e.g.19:00- 21:00).
CLEANING AND MAINTENANCE
Use a soft cloth to clean the platform. It is also possible to use a slightly dampened cloth.Do not use chemical or abrasive substances. After cleaning the platform make sure it is completely dry before carrying out a measurement. If the surface is wet or damp it could become slippery. Always position the scales on a stable and at surface. Avoid rugs and similar objects. Avoid jumping on the scales, dropping them or subjecting them to particular knocks. As well as for precision, the internal mechanisms are in fact very delicate, and could easily be damaged. Avoid exposing the product to electromagnetic waves that could cause the loss of data in the memory. The seller is not responsible for loss of data memorised in the scales. Note: All indications and diagrams are based on the latest information available when the manual was printed and may be subject to change. WARNINGS These scales should not to be used to weigh objects or substances in commercial transactions, to produce medicines, to calculate tolls, tariffs, taxes, premiums, nes, remunerations, indemnities or fees of a similar kind determined by weight. These BFW scales are to be used for keeping one’s own personal body weight, and percentages of fat and water, under control and are not to be used for making diagnoses or for medical treatment. Values that may seem unusual or outside the norm should always be discussed with your doctor. In order to avoid danger to the user of this device, the doses of any drug or therapy prescribed by one’s own doctor should in no circumstances be modied on the basis of data calculated by this device. Specications and designs are based on the latest information available at the time of printing and subject to change without notice. The product is made conforming with all the applicable European regulations.10
DISPOSAL The device (including its removable parts and accessories) must not be disposed of together with municipal waste at the end of its life, but in compliance with European Directive 2002/96/EC. Since it must be handled separately from household waste, either carry it to a separately-collected waste disposal centre for electrical and electronic appliances or give it back to the retailer on purchasing a new device with the same purpose. Any infringement will be severely prosecuted. The batteries used in this device must be disposed of in the special bins at the end of their life. NOTE: Specications and designs are based on the latest information available at the time of printing and subject to change without notice.
Joycare S.p.A., a company with a sole shareholder, offers a period of 3 year warranty after the date of purchase. The warranty does not cover damage caused by accidental breakage, transportation, incorrect maintenance or cleaning, misuse, tampering or repairs carried out by non authorised third parties. The following is also excluded: damage caused by incorrect product installation, and damage caused by wear and tear, obviously including parts subject to wear and tear. In order to obtain the replacement/repair of products under warranty in cases other than those mentioned above, but which are instead caused by manufacturing defects, please contact your local importer/distributer. Goods that are not held to be in good condition because of the aforesaid causes must be accompanied by this certicate, duly lled-in, as well as a receipt for the goods (invoices and transport documents) and purchasing documentation. Please keep the original packaging of the product.