F 163 C - Heating Jøtul - Free user manual and instructions
Find the device manual for free F 163 C Jøtul in PDF.
User questions about F 163 C Jøtul
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Heating in PDF format for free! Find your manual F 163 C - Jøtul and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. F 163 C by Jøtul.
USER MANUAL F 163 C Jøtul
Installation manual with technical data
1.0 Relationship to the authorities 4
2.0 Technical data 4
3.0 Safety 8
4.0 Installation 9
5.0 Daily use 12
6.o Service. 13
7.0 Maintenance 13
8.o Optional Equipment 14
9.o Warranty. 14

On all our products there is a label indicating the serial number and year. Write this number in the place indicated in the installation instructions.
Always quote this serial number when contacting your retailer or Jøtul.
Serial no.
1.0 Relationship to the authorities
Installation of a fireplace must be according to local codes and regulations in each country.
All local regulations, including those that refer to national and European standards, shall be complied with when installing the product.
Before use read the Installation and Operating Instructions carefully. Prior to using the product the installation must be inspected by a qualified person.
A name plate of heat-resistant material is affixed to the product on the underside of the burnchamber (Fig. 3 B). This contains information about identification and documentation for the product.
2.0 Technical data
Material: Cast iron Cast iron
Finish: Paint Paint/ena
Fuel: Wood Wood
Log length, max: 33 cm 33 cm
Flue outlet: Top/rear Top/rear
Flue pipe dimension: 150mm,177cm 150mm,177cm^2
cross section cross section
Weight F 162 / F 163: 115kg 115kg
Weight F 162 C / F 163 C: 134 kg 134 kg
Optional equipment: Cover for rear leg, Cover for rear leg,
soapstone top soapstone top
not for F 162 C (not for F 162 C
/F163C) /F163C)
Dimensions, distances: See fig.1 See fig.1
Technical data according to EN 13240
Flue gas mass flow: 5,0 g/s 5,0 g/s
Recommended
chimney draught: 12 Pa 12 Pa
Efficiency: 83% @5,9 kW 82% @5,9 kW
CO emission (13% O): 0,06% 0,10%
CO emission (13% O_2^·) 792 mg/Nm³ 1242 mg/Nm³
Flue gas temperature: 260^ 260^
Operational type: Intermittent Intermittent
Intermittent combustion is here taken to mean normal use of a fireplace. I.e. that a new flame chamber is lit as soon as the fuel has burnt down to the appropriate quantity of embers.

Min. distance to combustible wall, base model
180^
Jotul F162 C/F163 C


* With semi-insulated chimney / covered flue pipe down towards the product.
g00061-Po8

Jotul F 162 C/F 163 C
*** for F 162 C only

**Jotul F 162 C / F 163 C with semi-insulated chimney /
covered flue pipe down towards the product.
JotulF162/F163
13/14
537
1 1
137 300
***200
1 + u1 - 1 = ( 1 + u) u1 < 1 = u
*** for F 162 C only
The outside air connection may be fitted directly to the product through:
- Through a flexible supply hose from the outside or chimney (only if the chimney has its own duct for external air) and to the product's outside air connector.

Fig. 2a, through an outside wall Important! The knockout for the outside air connection must be removed from the inside. Use safety goggles.
Tip: It is a great advantage if the rear leg is dismounted before removing the knockout.
- Lay the product carefully down on its side. You can put the cardboard packaging on the floor to protect it from scratches, etc.
- Remove the rear leg.
- Use a heavy mallet and strike hard in the middle of the knockout.


Fig. 2b, through the floor and ground plate

Fig. 2c, through the floor and basement

Fig. 2d, indirectly through an outside wall
3.0 Safety
NBI To guarantee optimal performance and safety, Jøtul stoves must be fitted by a qualified installer.
Any modifications to the product by the distributor, installer or consumer may result in the product and safety features not functioning as intended. The same applies to the installation of accessories or optional extras not supplied by Jotul. This may also be the case if parts that are essential to the functioning and safety of the fireplace have been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable for the product and the right to make a complaint becomes null and void.
3.1 Fire Prevention Measures
There is a certain element of danger every time you use your fireplace. The following instructions must therefore be followed:
- The minimum safety distances when installing and using the fireplace are given in fig. 1.
- Ensure that furniture and other flammable materials are not too close to the fireplace. Flammable materials should not be placed within 1 metre of the fireplace.
- Allow the fire to burn out. Never extinguish the flames with water.
- The fireplace becomes hot when lit and may cause burns if touched.
- Only remove ash when the fireplace is cold. Ash can contain hot embers and should therefore be placed in a non-flammable container.
- Ash should be placed outdoors or be emptied in a place where it will not present a potential fire hazard.
In case of chimney fire:
- Close all hatches and vents.
- Keep the firebox door closed.
- Check the loft and cellar for smoke.
- Call the fire service.
- Before use after a fire an expert must check the fireplace and the chimney in order to ensure that it is fully functional.
4.o Installation
N.B. Check that the fireplace is free of any damage prior to commencing installation.
The product is heavy! Make sure you have assistance when erecting and installing the fireplace.
4.1 Floor
Foundations
Ensure that the floor is strong enough for the fireplace. See «2.0 Technical data» for weights. It is recommended that flooring which is not fastened to the foundations - so-called floating flooring - is removed during installation.
Combustible floor protection
If the fireplace is to be mounted on a combustible floor, cover the floor under and in front of the fireplace with a plate of metal or other non- combustible material. The recommended minimum thickness is 0,9 mm.
Any flooring made of combustible material, such as linoleum, carpets, etc. should be removed from under the floor plate.
The plate must be in accordance with national laws and regulations.
Contact your local building authority regarding restrictions and installation requirements.
4.2 Walls (fig. 1a)
Distance to wall made of combustible material
You may use the fireplace with an uninsulated flue pipe provided the distances to walls made of combustible materials are as shown in fig. 1.
Distance to wall with insulated flue pipe: Se fig.1.
Distance to walls covered by a firewall (fig. 1b and fig. 1c)
Contact your local building authority regarding restrictions and installation requirements.
Firewall requirement
The firewall must be at least 100 mm thick and be made of brick, concrete-stone or light concrete. Other materials and constructions with satisfactory documentation may also be used.
Distance to non combustible walls
By non combustible one means a non load-bearing wall of solid brickwork/concrete.
Contact your local building authority regarding restrictions and installation requirements.
4.3 Chimneys and flue pipes
- The fireplace can be connected to a chimney and flue pipe approved for solid fuel fired appliances with flue gas temperatures specified in «2.0 Technical data».
- The chimney's cross-section must be at least as big as the flue pipe's cross-section. See «2.0 Technical data» when calculating the correct chimney cross-section.
- Several solid fuel fired appliances can be connected to the same chimney if the chimney's cross-section is sufficient.
- Connection to the chimney must be carried out in accordance with the installation instructions from the supplier of the chimney.
- Before making a hole in the chimney the fireplace should be test-mounted in order to correctly mark the position of the fireplace and the hole in the chimney. See fig.1 for minimum dimensions.
- Ensure that the flue pipe is inclined all the way up to the chimney.
- Use a flue pipe bend with a sweeping hatch that allows it to be swept.
Be aware of the fact that it is particularly important that connections have a certain flexibility in order to prevent movement in the installation leading to cracks.
N.B. A correct and sealed connection is very important for the proper functioning of the product.
Chimney draught; See «2.o Technical data». If the draught is too strong you can install and operate a flue damper to control the draught.
4.4 Assembly prior to installation
The product is delivered in a single packing case.
After unpacking the stove check that the stove is free of any damage and that the regulating handles works.
4.5 Selfclosing doormechanism
The product is delivered with a selfclosing doormechanism. If wanted this can be removed.

Fig. 3
- Unscrew the screw and nut (fig. 3 A).
- Unhook and remove the spring.
ENGLISH
4.6 Fitting the flue pipe with the rear outlet
The product is supplied from the factory with the smoke outlet fitted for the top outlet.
NB! Proceed as follows for installation with a rear outlet:

Fig. 4
- Lift the baffle (Fig. 4 A) up carefully.
- Remove one of the side burn plates by lifting them up a little and then out. (Be aware if using tools, that vermiculite plates may be damaged by rough handling).
- Remove the baffle.
- Remove the other side burn plate.
- Remove the exhaust deflectors (Fig.4 B).

Fig. 5
- Unscrew the screws (fig. 5 A) and remove the smoke outlet (fig. 5 B) from the top outlet from the inside of the burn chamber.

Fig. 6a
- Unscrew the screws (fig. 6a c) and remove the cover (fig. 6a B) from the rear outlet from the inside of the burn chamber.

Fig. 6b
- Knock out the removable cover plates (fig. 6b A).
- Attach the smoke outlet (fig. 6a A) on the inside of the burn chamber where the cover was.
- Install the cover (fig. 6a B) where the smoke outlet was.
- Refit the exhaust deflectors (fig. 4 B) and the baffle plate (fig. 4 A).
4.7 Control of functions
When the product is set up, always check the control functions. These shall move easily and function satisfactorily.
Jotul F 162, F 162 C, F 163 and F 163 C are equipped with the following control:
Ignition vent/air vent
Ignition
Fig. 7a

- Open the ignition vent and air vent by pulling the handle all the way out. (Use a glove or something similar to protect your hand in case the handles are hot.)

- Place two logs at the bottom of the burn chamber and pile the kindling in layers.
- Finally, place a medium-sized log on the top of the pile.
- Place 2 or 3 briquettes or kindling sticks under the top layer of kindling and light the fire.
Heating
Fig. 7b

- Leave the ignition-/air vent 26mm (fig. 7 B) open when the wood has caught fire properly and is burning well.
- Close the door.
- You can then regulate the rate of combustion to give the heat you want by adjusting the air vent.
- Check that the afterburning (secondary combustion) starts. This is best indicated by yellow, flickering flames in front of the holes under the baffle.
Adding firewood
Stoke the stove frequently but only add small amounts of fuel at a time. If the stove is filled too full, the heat created may cause extreme stress in the chimney. Add fuel to the fire in moderation. Avoid smouldering fires as this produces the most pollution. The fire is best when it is burning well and the smoke from the chimney is almost invisible.
4-7 Danger of overheating
The fireplace must never be used in a manner that causes overheating
Overheating occurs when there is too much fuel and/or too much air so that too much heat develops. A sure sign of overheating is when parts of the fireplace glow red. If this happens, reduce the air vent opening immediately.
Seek professional advice if you suspect that the chimney is not drawing properly (too much/too little draught). For further information, see «4.0 Installation» (Chimney and flue pipe).
ENGLISH
5.0 Daily use
Odours when using the fireplace for the first time
When the fireplace is used for the first time, it may emit an irritating gas which may smell slightly. This happens because the paint dries. The gas is not toxic but the room should be thoroughly ventilated. Let the fire burn with a high draught until all traces of the gas have disappeared and no smoke or odours can be detected.
5.1 Operation
Heating advice
NB: Logs that have been stored outdoors or in a cold room should be brought indoors 24 hours before use to bring them up to room temperature.
There are various ways of heating the stove but it is always important to be careful about what you put in the stove. See the section on "Wood quality".
Wood quality
By quality wood we mean most well-known types of wood such as birch, spruce and pine.
The logs should be dried so that the moisture content is no more than 20% .
To achieve this, the logs should be cut during the late winter. They should be split and stacked in a way that ensures good ventilation. The wood stacks should be covered to protect the logs from rain. The logs should be brought indoors during early autumn and stacked/stored for use in the coming winter.
Be especially careful never to use the following materials as fuel in your fireplace:
Household rubbish, plastic bags, etc.
-
Painted or impregnated timber (which is extremely toxic).
-
Laminated wooden planks.
Driftwood
These may harm the product and are also pollutants.
NB: Never use petrol, paraffin, methylated spirit or similar liquids to light the fire. You may cause serious injury to yourself and damage to the product.
Wood consumption
Use of wood, with nominal heat emission: Approx. 1,6 kg/h. Another important factor for proper fuel consumption is that the logs are the correct size. The size of the logs should be:
Kindling:
Length: 23-33 cm
Diameter: 2 - 5 cm
Amount per fire: 6 - 8 pieces
Daily use
Firewood (split logs):
Length: 23-33 cm
Diameter: Approx. 8 cm
Intervals for adding wood: Approximately every 45 minutes
Size of the fire: 1,2kg
Amount per load: 2 pieces
Nominal heat emission is achieved when the air vent is open approximately 57% .
Maximum use
Max. load: 2,9 kg/h (max. 3 pieces per loac/2,2 kg per load)
5.2 Ash removal
Jotul F162/F162 C/F163/F163 C have an ash pan which makes it easy to remove the ash.

Fig. 8

-
Scrape the ash through the grate (fig. 8 A) in the base plate and into the ash pan. Use a glove to grab the handle on the ash pan.
-
Make sure that the ash pan doesn't fill up so high that it keeps ash from coming through the grate into the pan.
6.o Service
Warning! Any unauthorised change to the product is not allowed. Only use original spare parts.
6.1 Changing the burn plates/inner bottom plate

Fig.9

- Lift the baffle (Fig. 9 A) up carefully.
- Remove one of the side burn plates (Fig. 9 E) by lifting them up a little and then out. (Be aware if using tools, that vermiculite plates may be damaged by rough handling).
- Remove the baffle.
- Remove the other side burn plate.
- Unscrew the M8x25 mm screw on the rear burn plate (Fig. 9 F) and remove the burn plate.
- Then lift up and remove the inner bottom plate (Fig. 9 C). Follow the same procedure for installation, but in the opposite sequence.
6.2 Changing the baffle plate
Follow step 1-3 under Fig.9.
- Access is then easy to the smoke deflectors (Fig. 9 B) if they need to be removed. They are situated on 1 knob on the side and on the air manifold (fig. 9 D).
- Edge them down and remove them through the door. For re-installation follow the same procedure in the opposite sequence.
7.o Maintenance
7.1 Cleaning and soot removal
Soot deposits may build up on the internal surfaces of the fireplace during use. Soot is a good insulator and will therefore reduce the fireplace's heat output. If soot deposits accumulate when using the product, they can easily be removed by using a soot remover.
In order to prevent a water and tar layer from forming in the fireplace, you should regularly allow the fire to burn hot in order to remove the layer. An annual internal cleaning is necessary to get the best heating effect from your product. It is a good idea to do this when cleaning the chimney and flue pipes.
7.2 Sweeping flue pipes to the chimney
Flue pipes must be swept through the flue pipe sweeping hatch or through the door opening.
One of the baffles will have to be removed first in order to do this.
7.3 Inspection of the fireplace
Jotul recommends that you carefully inspect your fireplace yourself after it has been swept/cleaned. Check all visible surfaces for cracks. Also check that all joints are sealed and that the gaskets are in the correct position. Any gaskets showing signs of wear or deformation must be replaced.
Thoroughly clean the gasket grooves, apply ceramic glue (available from your local Jotul dealer) and press the gasket well into place. The joint will dry quickly.
7.4 Exterior maintenance
Painted products may change colour after several years' usage. The surface should be cleaned and brushed free of any loose particles before new paint is applied.
ENGLISH
8.o Optional equipment
8.1 Leg cover - outside air connection
Cat.no.51012329
8.2 Soapstone top - 50 mm, complete
Important! Soapstone top can not be used with Jøtul F 162 C / Jøtul F 163 C.
Cat.no.51012327
9.o Warranty
Jøtul AS provides its customers with a ten-year warranty with the right to return external cast-iron items if they show defects as a result of faulty materials and/or manufacturing after the initial purchase/installation of the fireplace. The buyer is entitled to return the goods provided that the fireplace has been installed in compliance with current laws and regulations and in compliance with Jøtul's installation and operating instructions.
The warranty does not cover:
The installation of optional extras, for example, to rectify local draught conditions, air supply or other circumstances beyond Jotul's control. The warranty does not cover consumables, such as burn plates, smoke baffles, fire grates, bottom grates, brick refractories, dampers and gaskets as they deteriorate over time due to normal wear and tear. The warranty does not cover damage caused as a result of using unsuitable fuel when lighting the fire, such as driftwood, impregnated and painted wood, plank offcuts, chipboard, etc. Overheating may easily occur if unsuitable fuel is used, i.e. the fireplace becomes red hot, which causes the paint to discolour and the cast iron parts to crack.
The warranty is not valid for damage caused while the product is in transit from the distributor to the delivery address. The warranty is not valid either for damage caused by the use of non-original parts.
Table des matieres
Massastroom rookgas: 5,0 g/s 5,0 g/s
Quality control of stoves and fireplaces
Checked
Utfort Kontrollpunkt
Controlled item
Jotul pursue a policy of constant product development. Products supplied may therefore differ in specification, colour and type of accessories from those illustrated and described in the brochure.
Jotul AS has a quality system that conforms to NS-EN ISO 9001 for product development, manufacturing, and distribution of stoves and fireplaces. This policy gives our customers quality and safety piece of mind as a result of Jotul's vast experience dating back to when the company first started in 1853.
EasyManual