Güde PRO 2200 A - Water pump

PRO 2200 A - Water pump Güde - Free user manual and instructions

Find the device manual for free PRO 2200 A Güde in PDF.

📄 64 pages English EN Download 💬 AI Question
Notice Güde PRO 2200 A - page 15
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about PRO 2200 A Güde

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Water pump in PDF format for free! Find your manual PRO 2200 A - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PRO 2200 A by Güde.

USER MANUAL PRO 2200 A Güde

ENGLISH Please read the instructions carefully before starting the machine.

English TECHNICAL DATA | SPECIFIED CONDITIONS OF USE | SAFETY INSTRUCTIONS MAINTENANCE | GUARANTEE | EC-DECLARATION OF CONFORMITY 11

FRANÇAIS CARACTÉRISTIQUES TECHNIQUES | UTILISATION CONFORME à LA DESTINATION | CONSIGNES DE SECURITÉ | ENTRETIEN | GARANTIE | DÉCLARATION DE CONFORMITÉ CE 15

Art.No .75800 .75805 .75810

Service connection. 230V~50Hz .230V~50Hz.. 230V~50Hz

Motor output P1. 1100 W 2200 W 2200 W

Max. head of delivery 9 m 17 m 17 m

Max.immersion. 5m .5m.

Max. delivered quantity 19800 l/h .42000 l/h .42000 l/h

Max.suction. 20 mm 20 mm 20 mm

Max. Water temperature. 35°C 35°C 35°C

Hose connection. 2^ IG 3IG..2,5'IG

IP68 Degree of protection.. IP68 IP68 IP68

Weight. 21,5 kg 31 kg 31 kg

Güde PRO 2200 A - 1

Güde PRO 2200 A - 2

Read and understand the operating instructions before using the appliance. Abide by all the safety

measures stated in the service manual. Act responsibly toward third parties.

In case of any doubts about connection and operation refer please to our customer center

Specified Conditions Of Use

The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm and agriculture and only for water. Respecting technical data and safety precautions.

Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.

The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
Do not use the pump for drinking water!
The pump must not be used to pump waste water.

Safety Instructions

WARNING!

Electric shock! There is a risk of an injury caused by electric shock!

This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device.

Children should be supervised to ensure that they do not play with the device. Always keep children and unauthorised persons out of reach of the appliance.

Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA ).

Before putting into operation, a qualified electrician must check whether electric safety measures required are in place. Any national regulations in this regard must be complied with.

Electric connection to a socket.

It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.

Check the voltage. Technical data given on the type label must correspond with electric network voltage.

Only use splash proof extension cables approved for outdoor purposes.

Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!

Check the cable and/or socket for damages before the appliance putting into operation.

12

ENGLISH

To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.

Protect the feeder cable from excessive temperatures, oil and sharp edges.

Unplug the device prior to submersion, upon termination of operation, in the course of defect removal and prior to performing maintenance procedures.

If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).

The pump must not in any case run without fillings.

Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.

The temperature of the drained liquid must not exceed +35^

If the lubricant escapes the fluid could become contaminated.

If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.

The user is responsible to third parties if pump (dumping stations, etc.) is used.

Güde PRO 2200 A - ENGLISH - 1

Risk of injury around the crusher on the atom of the pump.

Touch the appliance on the top on the handle only. Do not touch the rotating tool.

Requirements for operating staff

The operating staff must carefully read the Operating Instructions before using the appliance.

Qualification: Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.

Minimum age: Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.

Training: Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary.

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If you seek help, state the following pieces of information:

  1. Accident site
  2. Accident type
  3. Number of injured persons
  4. Injury type(s)

Maintenance

Güde PRO 2200 A - Maintenance - 1

Before carrying out any work on the machine, connect the plug from the socket.

Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.

The machine must not be used under any circumstances if the machine or the safety devices are damaged.

Refer all servicing to customer service. Use only original accessories and original spare parts.

To ensure long service life of the pump seal we recommend rinsing the pump with clean water in regular intervals.

At winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with appropriate oil (for example, with vegetable oil).

Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.

Oil products must not come into contact with skin, eyes and clothing.

Make sure the oil products do not enter the soil.

Guarantee

Guarantee claims as per guarantee card attached.

The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.

The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee..

GüDE cannot be held responsible for damages incurred in consequence of unqualified installation or unskilled handling of the pump.

The device has to be checked on a regular basis to ensure perfect functioning.

Let us refer to the fact we do not assume any responsibility - according to standards in force - for damage eventually caused by our appliances in the below-mentioned cases: Unprofessional repairs executed by unauthorised service centres; Use in conflict with the designed purpose, or failure to observe the use as designed; Pump overload with a continuous run; Damage as a result of icing or any other fault caused by climatic influences; Identical regulations apply for accessory parts.

To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).

Service

Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guide.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference:

Serial No.:

Art. No:

Year of production:

Symbols

Güde PRO 2200 A - Symbols - 1

Read the Operating Instructions

Güde PRO 2200 A - Symbols - 2

Before carrying out any work on the machine, disconnect the plug from the socket.

Güde PRO 2200 A - Symbols - 3

Cable pulling / transport prohibited

Güde PRO 2200 A - Symbols - 4

Staying in the transportation medium prohibited

Güde PRO 2200 A - Symbols - 5

Warning against dangerous electric voltage

Güde PRO 2200 A - Symbols - 6

Warning against automatic starting

Güde PRO 2200 A - Symbols - 7

Do not touch the rotating tool.

Güde PRO 2200 A - Symbols - 8

2 people are needed for implementation.

Güde PRO 2200 A - Symbols - 9

Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.

Dispose the waste oil in an environment-friendlyly manner!

Güde PRO 2200 A - Symbols - 10

Protect against humidity

Güde PRO 2200 A - Symbols - 11

This side up

EC-Declaration of Conformity

GÜDE GmbH & Co. KG

We, hereby declare the conception and construction of the below mentioned appliances correspond - at the type of construction being launched - to appropriate basic safety and hygienic requirements of EC Directives. In case of any change to the appliance not discussed with us the Declaration expires.

Plunge pump

PRO 1100 A #75800

PRO 2200 A #75805

PRO 2201 S #75810

Appropriate EU Directives

2006/95 EG, 2004/108 EG

Harmonised standards used

EN 55014-1:2006 + A1:2009

EN 55014-2:1997 + A1:2001 + A2:2008

EN 61000-3-2:2006 + A1:2009 + A2:2009

EN 61000-3-3:2008

EN 50366:2003 + A1:2006

EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 +

A2:2006 + A13:2008 + A14:2010

EN 60335-2-41:2003 + A1:2004 + A2:2010

Güde PRO 2200 A - Harmonised standards used - 1

Güde PRO 2200 A - Harmonised standards used - 2

Wolpertshausen, 2012-01-13 Helmut Arnold

Managing Director

Technical documentation Joachim Bürkle

Inspection and maintenance plan

Time interval Description Any other details
As needed Cleaning and rinsing outFunction check of the floating switch
After 12 months Oil change→5 10 W - 40, max 100 ml

Failures - causes - removal

Failures Causes Removal
Engine does not start No power supply. Blocked pump wheel Floating switch in shutdown positionCheck the voltage Visually inspect the pump wheel for foreign objects Check the water levelSwitch the pump off, water level must go up. Remove the obstruction
Pump does not suck Water level too low Blocked pump wheel
Insufficient amount of water pumpedThe crusher wheel is dirty Water level quickly drops down Maximum head of delivery exceeded Broken pipingClean the crusher wheel Ensure sufficient inflow Check the transport line Check the transport line

\section*{Caracteristiques Techniques}

Cod.ord: 75800 .75805 .75810

Allacciamento. 230V\~50Hz .230V\~50Hz .230V\~50Hz

→ 10 W - 40, max 100 ml

Ako n3TeKaT CMA3OuH CpeCTBa MoKe Da Ce CTnIHe Do 3aMbpcBaHa He TeuHOCTa.

Korato NOMnata Ce n3noJ3Ba B e3epa, KlaeHn N T.H. IN B CbOTBeTHN BOONPOBOHN CTaHn HEnpeMeHHO Tp6Ba Da Ce cna3BaT cbueCTByBaunTe HOPMn 3a ynotpe6a Ha NOMn B daJeHaT TaBpxkaba.

Iotpe6nten oTROBAPcnpa TpeTu nua 0o ce OTHACdo yNtpe6ata Ha nomnata (BOOONPOBOHn CTAHm n T.H.)

A CbuecTBBya pnck 3a HapaHbaHe okono TpowaKaTa Ha dbHOTo Ha NOMnTa.

IokocBaTe ypea cmo OTrope 3a dpbKkata. He IOKOCBaTe BbpTnue Ce INHCTpyMeHT.

N3nCKBaHmna 3a 06cnyKBaHe

Ppeynynoptpe6aHa ypeDa 06cnykBaunr Tpr6Ba BHMaTeHNO da npOye YnTBAHeTo 3a 06cnykBaHe.

Kbainnka:OcbeHnoIpo6Ho noyehne OT cneuaanCT 3a H3NOJ3BaHeTo Ha ypeHa He e Heo6xOIMHa HIKaKBA cneuaJHa KBaINnKaJna.

MnHmMaHa Bb3pact: Cypeda Morat da pa6oTcamaNoIuca, KOnTo ca HABbpwnn 16rOHN.

N3KJIUOHeHn npaBn 3n0nI3BaHeTo Ha HeNbJHOJIeTHn cAmo, aKO TOBa CTaBa nO BpeMe Ha npofoecnoHaJIHOto o6yueHne C cEi NoCTnraHe Ha yMeHne NOD HaI3Opa Ha o6yuaBIoTO Iuie.

06yehne: N3noJ3BaHeTo Ha ypea n3nCKBa cAmO cbOTBeTHo NOyAbaHe OT CneuAnCT, peCn. yTbTBAHe 3a 06cnyjBaHe. CneuaHNo 06yehne He e HEO6xOIMo.

Kolarov Technologic O.O.D.

Jordan Bogdar 4

BG-8800 Sliven

Tel: 00359/886568083

Fax: 00359/44680404

Austria

Güde GmbH & Co. KG

Albrechtsberg 12

SK-03301 Liptovsky Hrdok

Tel: 0042/1445225151

Fax: 0042/1445225151

Romania

SC COM LANKA SRL BAIA MARE

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Güde

Model : PRO 2200 A

Category : Water pump