ModelLSC (Light Shower)
Power supply230 V ~ 50 Hz
Power consumptionApprox. 72 W
Light intensity10,000 Lux at 10 cm
Light sources2 fluorescent tubes (daylight, 36 W each, type PHILIPS PL-L36W/865/4P)
Tube lifespanApprox. 8,000 hours of average use
Dimensions (L x W x H)Approx. 310 mm x 255 mm x 555 mm
WeightApprox. 2.7 kg
Cable lengthApprox. 1.8 m
Protection classClass I
Moisture protection ratingIP20
Operating conditions+5 °C to +45 °C, relative humidity 30 - 90 %
Storage conditions+5 °C to +50 °C, relative humidity 30 - 90 %
Recommended use distance20 to 60 cm from the screen
Recommended maximum usage time2 hours per day (depending on distance)
Main functionsLight therapy for seasonal affective disorder (SAD), fatigue, lack of energy, mood changes
Cleaning and maintenanceSoft cloth slightly damp (mild soap solution), do not immerse, let cool before cleaning
Safety instructionsDo not use by persons (including children) with reduced capacities without supervision, do not stare at the lit screen for long periods, unplug before cleaning
Spare parts and repairabilityReplacement of fluorescent tubes by an authorized professional; replace tubes in pairs, same type
Article number45210
EAN number40 15588 45210 9

Frequently Asked Questions - LSC MEDISANA

What is the Medisana LSC light shower used for?
The device is designed for light therapy and works against seasonal affective disorder (SAD), also known as 'winter blues'. It helps compensate for the lack of light in autumn and winter, reducing symptoms such as fatigue, mood changes, and lack of energy.
What is the ideal distance between me and the device during a session?
The recommended distance is between 20 and 60 cm from the luminous screen. The closer you are, the shorter the usage time should be: about 30 minutes at 20 cm, 1 hour at 40 cm, and 2 hours at 60 cm.
How long can I use the device per day?
The maximum usage time is 2 hours per day. The best time is between 6 am and 8 pm. For optimal results, use it for at least five consecutive days.
Can I do other things during a light therapy session?
Yes, you can read, watch TV, or work on a computer, as long as you stay within 60 cm of the screen. It is not necessary to look directly at the screen continuously.
How to clean the LSC light shower?
Before cleaning, turn off the device and unplug it. Let it cool completely. Use a soft, lint-free cloth, slightly dampened with a mild soap solution, then wring it well. Never immerse the device in water and do not use harsh products.
When should the fluorescent tubes be replaced?
The tubes have a lifespan of about 8,000 hours. If a tube is defective, it must be replaced. Entrust this operation to an authorized professional, as the device must be disassembled. Always replace both tubes at the same time, with tubes of the same type (PHILIPS PL-L36W/865/4P).
Are there any contraindications for using this device?
Consult your doctor before use if you suffer or have suffered from major depression, if you are hypersensitive to light, if you have an eye disease, if you are taking certain medications (psychotropics, antimalarials), or if you have high blood pressure.
Can I use the device if I wear contact lenses?
There is no specific contraindication in the instructions, but it is recommended not to stare directly at the lit screen for extended periods. If you have concerns, consult an ophthalmologist.
Does the device get hot?
The device may heat up during use. After each session, let it cool for at least 15 minutes before storing or touching it. Do not cover it during operation.
What is the warranty for the Medisana LSC device?
Medisana provides a warranty of 3 years from the date of purchase (upon presentation of proof of purchase). Excluded from the warranty are damages due to incorrect use, unauthorized interventions, transport damage, and normal wear and tear (such as fluorescent tubes).

User questions about LSC MEDISANA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Light therapy in PDF format for free! Find your manual LSC - MEDISANA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LSC by MEDISANA.

USER MANUAL LSC MEDISANA

G B Phototherapy Unit LSC

Please read carefully!

1 Safety Information 9
2 Useful Information 12
3 Operation 13
4 Miscellaneous 14
5 Warranty 16

FR Mode d'emploi

1 Consignes de sécurité ..... 17
2 Informations utiles 20
3 Application 21
4 Divers 22
5 Garantie 24

Please fold out this page and leave it folded out for quick reference.

1 fluorescent screen
2 cord with plug
3 top cover
4 stand
5 rear base
6 rear part
7 front base
8 ON/OFF button

FR 1 Ecran luminescent

2 Câble avec fiche

Taishan Anson Electrical Appliances Co.Ltd Dragon Mountain Industrial Estate, Duanfen, Thaishan, Guangdong Province, China

Distributed & imported by MEDISANA AG Jagenbergstraße 19 • 41468 NEUSS • Deutschland

EC REP

CARLA Sarl • Zone Artisanale • F-67570 La Claquette • France

natural_image Simple icon of an open book with a lowercase 'i' in the front page, no text or symbols present.

IMPORTANT INFORMATION! RETAIN FOR FUTURE USE!

Read the instruction manual carefully before using this device, especially the safety instructions, and keep the instruction manual for future use. Should you give this device to another person, it is vital that you also pass on these instructions for use.

Explanation of symbols

MEDISANA LSC - Explanation of symbols - 1

This instruction manual belongs to this device. It contains important information about starting up and operation. Read the instruction manual thoroughly. Non-observance of these instructions can result in serious injury or damage to the device.

MEDISANA LSC - Explanation of symbols - 2

WARNING These warning notes must be observed to prevent any injury to the user.

MEDISANA LSC - Explanation of symbols - 3

CAUTION These notes must be observed to prevent any damage to the device.

MEDISANA LSC - Explanation of symbols - 4

NOTE These notes give you useful additional information on the installation or operation.

IP20

Ingress protection IP20

MEDISANA LSC - Explanation of symbols - 5

Electrical safety rating: class I

MEDISANA LSC - Explanation of symbols - 6

Lot number

MEDISANA LSC - Explanation of symbols - 7

Manufacturer

MEDISANA LSC - Explanation of symbols - 8

Date of manufacture

Proper use

- The LSC phototherapy unit provides a light bath to treat seasonal affective disorder (SAD), also known as the "winter blues".

Contraindication

- Before using the appliance, consult your doctor if you:

— suffer or have suffered from serious depression
— are hypersensitive to light
— suffer from eye disease
— take certain drugs, for example psychotropic or antimalarial drugs
— suffer from high blood pressure

MEDISANA LSC - Contraindication - 1

Safety Information

about the power supply

  • Before connecting the device to your power supply, please ensure that the supply voltage stated on the rating plate is compatible with your mains supply.
  • Do not use the appliance if it is damaged, if its power cord or plug is damaged, if it is not in perfect working order, or if it has been dropped or fallen into water.
  • If you notice any damage, dispose of the appliance or have it repaired by an authorised service centre. Do not attempt to repair the device yourself in the event of a malfunction since this will invalidate the warranty.
  • Only insert the plug into a power socket when the appliance is switched off.
  • Do not touch the mains plug if you are standing in water and only ever touch the plug when your hands are dry.
  • If the device falls into water, do not try to pick it up. Instead pull the plug out immediately.
  • Keep the appliance and its power cord away from hot surfaces, naked flames and other heat sources.
  • Lay the power cord so that there is no danger of tripping over it.
  • Switch off all functions after use and pull the plug out of the power socket.
  • Always pull on the plug itself when disconnecting the device from the power supply. Never pull on the power cord!
  • Never carry, pull or rotate the device by the mains cable and never pinch the cable between other objects. Do not wind the cord around the appliance.

specific groups of people

  • This device is not designed to be used by persons (including children) with limited physical, sensory or mental abilities, or by persons with insufficient experience and/or knowledge, unless under observation by a person responsible for their safety, or unless they have been instructed in the use of the device.
  • Children must be supervised to ensure that they do not play with the device.
  • On first using the appliance, you may experience eye fatigue or headache. This is normal and soon passes. If the symptoms persist, consult your doctor and stop using the appliance.

- Consult your doctor if using the appliance leads to hyperactivity, exhaustion, depression, restlessness, sleep disorders or other health problems. In this case, stop using the appliance immediately.

operating the unit

  • Use the device only according to its intended purpose as specified in the instruction manual. The warranty will be invalidated if the device is used for purposes other than those for which it is intended.
  • Before each use, check the appliance, power cord and plug for damage. Never use the appliance if it is damaged or if its power cord or plug is damaged.
  • If you notice any damage, dispose of the appliance or have it repaired by an authorised service centre.
  • The appliance is designed for private households only and not for commercial use.
  • Only use the appliance in enclosed rooms, never outside or in damp rooms.
  • Place the device on a firm, level surface during use so that it cannot tip over.
  • The appliance is not designed for lighting rooms. Do not use it in rooms which have no lighting of their own.
  • Do not look directly at the fluorescent screen for any length of time when it is switched on.
  • Do not leave the appliance unattended when it is in operation. This is especially important when children are using it.
  • Do not cover up the appliance during operation or while it is cooling down.
  • After each use and before cleaning, switch off the appliance using the ON/OFF button ⑧ and unplug the power cord from the socket.

maintenance and cleaning

  • You may only clean the device yourself. If the device malfunctions please do not repair it yourself as this leads to the automatic expiry of all guarantee rights. Consult your specialist dealer and only have repairs, such as replacing the power cord, performed by authorised service centres or similarly qualified specialist to avoid any risk of danger.
  • Do not immerse the device in water or other fluids.
  • If, nonetheless, liquid should penetrate the device, unplug the mains cable immediately.
  • After each use and before cleaning, switch off the appliance using the ON/OFF button ⑧ and unplug the power cord from the socket. Risk of electric shock!
  • Be careful when handling fluorescent lamps – they can easily break.
  • Do not touch the appliance, the power cord or the plug with damp or wet hands, as this can lead to electric shock.
  • Do not expose the appliance to direct sunlight or high temperatures. Protect it from dust and moisture.
  • Do no use abrasive cleaning agents.

Thank you very much

Thank you for your confidence in us and congratulations!

The LSC phototherapy unit is a quality product from MEDISANA. To get the best use of your MEDISANA LSC phototherapy unit and to ensure a long service life, we recommend that you carefully read the following instructions on using and taking care of it.

2.1 Items supplied and packaging

Please check first of all that the device is complete and is not damaged in any way. If in doubt, do not use it. Send it to a service point.

The following parts are included:

• 1 MEDISANA LSC phototherapy unit
• 2 Instruction manuals

The packaging can be reused or recycled. Please dispose properly of any packaging material no longer required.

If you notice any transport damage during unpacking, please contact your dealer without delay.

MEDISANA LSC - Items supplied and packaging - 1

WARNING

Please ensure that the polythene packing is kept away from the reach of children! Risk of suffocation!

2.2 Special features of the LSC phototherapy unit

Many people suffer from symptoms of tiredness in winter due to the lack of sunlight.

The LSC phototherapy unit provides a light bath to treat seasonal affective disorder (SAD), also known as the "winter blues".

It is an appropriate and effective method of compensating for the lack of sunlight in the autumn and winter without resorting to drugs.

Possible applications

The appliance is used to counteract the following symptoms of winter depression:

  • Fatigue
  • Mood swings
  • Listlessness
  • Sleepiness
  • Lack of concentration
  • Lack of appetite

Time, frequency and duration of use

The most effective time of day to use the phototherapy unit is between 6 in the morning and 8 in the evening. You can use the unit for up to 2 hours daily.

You can use the phototherapy unit as often as you like. However, the treatment is most effective if you use it on at least five successive days.

The length of time you can use the LSC phototherapy unit depends on how far you are away from it:

Distance to panel Maximum duration of use

60 cm approx. 2 hours

40 cm approx. 1 hour

20 cm approx. 30 minutes

3 Operating

3.1

Usage

  1. Fold down the stand ④ which can be found on the back of the device and place the device on a stable, level surface (e.g. a table). and place the appliance on a stable, level surface (such as a table).

  2. Connect the power plug ② to a socket and switch on the appliance using the ON/OFF button ⑧.

  3. Sit at a distance of 20 - 60 cm from the fluorescent screen ① in front of the unit so that the light easily reaches you. You do not have to sit facing the unit.

  4. The duration of the treatment depends on how far you are sitting from the unit (see "2.2 Special features of the LSC phototherapy unit").

  5. You can take a break or stop at any time. As long as you do not move more than 60 cm away from the unit, you can do other things during the treatment, such as read or watch television.

  6. Do not look directly at the fluorescent screen 1 for any length of time when it is switched on. It is enough to regularly turn your face towards it.

  7. Always switch off the appliance using the ON/OFF button ⑧ and unplug it from the socket when it is not in use.

  8. Let the appliance cool down for at least 15 minutes before putting it away or touching it.

MEDISANA LSC - Usage - 1

NOTE

To carry the device more easily, use the grip recess in the upper section of the rear side.

3.2 Changing the fluorescent lamps

On average, the fluorescent lamps need to be changed after approximately 8000 hours' use. If a lamp fails, it must be replaced.

In order to change a fluorescent lamp, the appliance must be completely disassembled. Have the lamps changed by your specialist dealer, an authorised service centre or a qualified specialist to prevent damage to the appliance.

MEDISANA LSC - Changing the fluorescent lamps - 1

WARNING

  • Used fluorescent lamps must be disposed of in accordance with the applicable regulations on environmentally harmful waste. If you have any questions about disposal, contact your local authority or your dealer.
  • Before changing the fluorescent lamps, the device must always be switched off using the ON/OFF switch ⑧ and the power plug ⑤ must be disconnected from the mains socket. Beware of electric shock.
  • Be careful when handling fluorescent lamps – they can easily break.
  • Always replace fluorescent lamps with lamps of the same type. Always replace both lamps at the same time.

4 Miscellaneous

4.1 Cleaning and maintenance

  • Before cleaning the appliance, switch it off using the ON/OFF button ⑧ and pull the power plug ⑤ out of the socket. Risk of electric shock!
  • Let the appliance cool down completely before cleaning it.
  • Do not immerse the device in water or other fluids.
  • When cleaning the device, never use aggressive cleaning agents, scouring agents or solvents; neither should you use scouring pads, steel wool or tough brushes. This can damage the surfaces.
  • Clean the appliance using a soft, lint-free cloth, if necessary dampened with mild, warm soapy water and well wrung out. Do not allow water to penetrate the appliance.
  • Only use the appliance again after cleaning once it is completely dry.
  • Do not expose the unit to direct sunlightor high temperature; protect it against dust and moisture.
  • Keep the appliance in a safe, dry place, preferably in the original packaging.

4.2

Disposal
MEDISANA LSC - 4.2 - 1

MEDISANA LSC - 4.2 - 2

This product must not be disposed of together with domestic waste.

All users are obliged to hand in all electrical or electronic devices, regardless of whether or not they contain toxic substances, at a municipal or commercial collection point so that they can be disposed of in an environmentally acceptable manner.

Consult your municipal authority or your dealer for information about disposal.

4.3

Technical specifications

Name and model : MEDISANA LSC Phototherapy Unit

Voltage supply : 230 V\~ 50 Hz

Power consumption : approx. 72 W

Illuminance : 10 000 lux at 10 cm

Illuminant : 2 x 36 W daylight fluorescent lamps

(PHILIPS, PL-L36W/865/4P)

Electrical safety rating : class I

Ingress protection : IP20

Operating conditions : + 5 °C to + 45 °C,

30 - 90 % relative humidity

Storage conditions: + 5 °C to + 50 °C

30 - 90 % relative humidity

Dimensions : approx. 310 mm x 255 mm x 555 mm

Weight : approx. 2.7 kg

Power cable length : approx. 1.8 m

Article No. : 45210

EAN Code : 40 15588 45210 9

Electromagnetic compatibility:

The device complies with the EN 60601-1-2 standard for electromagnetic compatibility.

Inquire at MEDISANA for details on this measurement data.

C€0197

In accordance with our policy of continual product improvement, we reserve the right to make technical and optical changes without notice.

Warranty and repair terms

Please contact your dealer or the service centre in case of a claim under the warranty. If you have to return the unit, please enclose a copy of your receipt and state what the defect is.

The following warranty terms apply:

  1. The warranty period for MEDISANA products is three years from date of purchase. In case of a warranty claim, the date of purchase has to be proven by means of the sales receipt or invoice.
  2. Defects in material or workmanship will be removed free of charge within the warranty period.
  3. Repairs under warranty do not extend the warranty period either for the unit or for the replacement parts.

  4. The following is excluded under the warranty:

a. All damage which has arisen due to improper treatment, e.g. non-observance of the user instructions.
b. All damage which is due to repairs or tampering by the customer or unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the consumer or during transport to the service centre.
d. Accessories which are subject to normal wear and tear (fluorescent lamps etc.).

  1. Liability for direct or indirect consequential losses caused by the unit are excluded even if the damage to the unit is accepted as a warranty claim.

MEDISANA LSC - Warranty and repair terms - 1

Taishan Anson Electrical Appliances Co.Ltd Dragon Mountain Industrial Estate, Duanfen, Thaishan, Guangdong Province, China

Distributed & imported by MEDISANA AG Jagenbergstraße 19 • 41468 NEUSS • Germany

EC REP

CARLA Sarl • Zone Artisanale • F-67570 La Claquette • France

The service centre address is shown on the attached leaflet.

MEDISANA LSC - EC REP - 1

natural_image Simple icon of an open book with a lowercase 'i' inside, no text or symbols present.

REMARQUE IMPORTANTE! TOUJOURS CONSERVER!

Taishan Anson Electrical Appliances Co.Ltd Dragon Mountain Industrial Estate, Duanfen, Thaishan, Guangdong Province, China

Distributed & imported by MEDISANA AG Jagenbergstraße 19 • 41468 NEUSS • Allemagne

EC REP

CARLA Sarl • Zone Artisanale • F-67570 La Claquette • France

Taishan Anson Electrical Appliances Co.Ltd Dragon Mountain Industrial Estate, Duanfen, Thaishan, Guangdong Province, China

Distributed & imported by MEDISANA AG Jagenbergstraße 19 • 41468 NEUSS • Germania

EC REP

CARLA Sarl • Zone Artisanale • F-67570 La Claquette • France

natural_image Simple icon of an open book with a lowercase 'i' inside, no text or symbols present.

Taishan Anson Electrical Appliances Co.Ltd Dragon Mountain Industrial Estate, Duanfen, Thaishan, Guangdong Province, China

Distributed & imported by MEDISANA AG Jagenbergstraße 19 • 41468 NEUSS • Alemania

EC REP

CARLA Sarl • Zone Artisanale • F-67570 La Claquette • France

natural_image Simple icon of an open book with a lowercase 'i' inside, no text or symbols present.

NOTAS IMPORTANTES! GUARDAR SEM FALTA!

Taishan Anson Electrical Appliances Co.Ltd Dragon Mountain Industrial Estate, Duanfen, Thaishan, Guangdong Province, China

Distributed & imported by MEDISANA AG Jagenbergstraße 19 • 41468 NEUSS • Alemanha

EC REP

CARLA Sarl • Zone Artisanale • F-67570 La Claquette • France

natural_image Simple icon of an open book with a lowercase 'i' inside, no text or symbols present.

Taishan Anson Electrical Appliances Co.Ltd Dragon Mountain Industrial Estate, Duanfen, Thaishan, Guangdong Province, China

Distributed & imported by MEDISANA AG Jagenbergstraße 19 • 41468 NEUSS • Duitsland

EC REP

CARLA Sarl • Zone Artisanale • F-67570 La Claquette • France

natural_image Simple icon of an open book with a lowercase 'i' in the center, no text or symbols present.

Taishan Anson Electrical Appliances Co.Ltd Dragon Mountain Industrial Estate, Duanfen, Thaishan, Guangdong Province, China

Distributed & imported by MEDISANA AG Jagenbergstraße 19 • 41468 NEUSS • Saksa

EC REP

CARLA Sarl • Zone Artisanale • F-67570 La Claquette • France

natural_image Simple icon of an open book with a lowercase 'i' inside, no text or symbols present.

OBSERVERA! SPARA!

Taishan Anson Electrical Appliances Co.Ltd Dragon Mountain Industrial Estate, Duanfen, Thaishan, Guangdong Province, China

Distributed & imported by MEDISANA AG Jagenbergstraße 19 • 41468 NEUSS • Tyskland

EC REP

CARLA Sarl • Zone Artisanale • F-67570 La Claquette • France

natural_image Simple icon of an open book with a lowercase 'i' in the front page, no text or symbols present.

Taishan Anson Electrical Appliances Co.Ltd Dragon Mountain Industrial Estate, Duanfen, Thaishan, Guangdong Province, China

Distributed & imported by MEDISANA AG Jagenbergstraße 19 • 41468 NEUSS • Γερμανία

EC REP

CARLA Sarl • Zone Artisanale • F-67570 La Claquette • France

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : MEDISANA

Model : LSC

Category : Light therapy