X80/20 PROTEC - Booster pump SPIDO - Free user manual and instructions
Find the device manual for free X80/20 PROTEC SPIDO in PDF.
User questions about X80/20 PROTEC SPIDO
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Booster pump in PDF format for free! Find your manual X80/20 PROTEC - SPIDO and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. X80/20 PROTEC by SPIDO.
USER MANUAL X80/20 PROTEC SPIDO
EU declaration of conformity
We, DIPRA, declare in our sole responsibility that the product identified below comply with the basic requirements imposed by the EU directives specified below including all subsequent amendments.
Directive 2000/14/CE annex. V
Suction line
Suction filter
3A 3B Non-return valve (x2)
4 Pressure line
5 Shut-off cock
6 Suction port
Pressure port
8 Filling opening for water
9 Drain screw for water
10 Pump housing
1 Terminal box
Probe switch
13Armoured hose
Pressure switch
Pressure gauge
16 Pressure tank
Tank valve with protective cap
18
19 Temperature sensor
HMT: Max. delivery height.
HA: Suction head (between the surface of water and the pump)
HI : Difference between surface of the liquid to be pumped and entrance of the suction line (min 0.3m)
Please read through these operating instructions carefully to make sure that you can fully benefit from all features.
TABLE OF CONTENTS
- General safety information
- Technical Data
- Range of use
- Scope of delivery
- Installation
- Electrical connection
- Putting into operation
- Setting the pressure switch
- Operating the pump with a SPIDO prefilter
- Maintenance and troubleshooting
- Warranty - Service
1. GENERAL SAFETY INFORMATION
Please read through these operating instructions carefully and make yourself conversant with the control elements and the proper use of this product. We shall not be liable in the case of damage caused as a result of the non-observation of instructions and provisions of the present operating instructions. Any damage caused as a result of the non-observation of the instructions and regulations contained in the present operating instructions shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand them on together with the device should you ever dispose of it.
- The pump must not be used by children. The pump may be used by persons with reduced physical, sensory or mental capabilities or lack of experience and / or knowledge if they have been supervised or instructed in the safe use of the equipment and have understood the resulting hazards. Children are not allowed to play with the device.
- Keep the appliance and its cord out of reach of children.
- The pump must not be used when people are in the water.
- The pump must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA .
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Disconnect the device from the power supply and let it cool down before cleaning and maintenance is performed and before the device is stored.
Always protect electrical parts against moisture. During cleaning or operation, they must not be immersed in water or
other liquids to ensure that an electrical shock is prevented. Never hold the device under running.
- Notes and instructions with the following symbols require particular attention :

Any non-observance of these instructions involves the danger of bodily harm to people and/or damage to property.

Any non-observation of this instruction bears the risk of an electrical shock which may cause damage to persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be informed immediately, at the latest within 8 days after the date of purchase.
2. TECHNICAL DATA
| Model | X80/20 PROTEC |
| Mains voltage / Frequency (V / Hz) | 230/50 |
| Nominal performance (Watts) | 800 |
| Protection type (IP) | 44 |
| Suction port | F26/34 (1") |
| Pressure port | F26/34 (1") |
| Max. flow rate (Qmax) (1) (l/h) | 3300 |
| Max. pressure (3) (bar) | 4,6 |
| HMI Max. delivery height (Hmax) (1) (m) | 46 |
| HA Max. suction height (m) | 9 |
| Vessel material | STEEL |
| Tank volume (l) | 22 |
| Max. size of the solids being pumped (mm) | 3 |
| Min. fluid temperature (℃) | 5 |
| Max. fluid temperature (Tmax) (℃) | 35 |
| Length of connection cable (m) | 1,5 |
| Cable type | H05-RN-F |
| Weight (net) (kg) | 13,4 |
| Guaranteed sound power level (LWA) (2) (dB) | 81 |
| Measured sound power level (LWA) (2) (dB) | 77 |
| ACS | YES |
| Dimensions (L x D x H) (mm) | 485 x 270 x 551 |
1) The values were determined with free, unreduced in- an outlet.
2) Noise emission values obtained according to the EN 12639 regulation. Measurement method according to EN ISO 3744.
| Preset of the pressure switch | |
| Cut-in pressure (bar) | 2 |
| Cut-out pressure (bar) | 3,5 |
3) The theoretically achievable pressure of the pump unit of the domestic water supply can reach the value specified under "Max pressure". Consult a qualified specialist, to adapt the pressure circuit to your requirements if necessary, see also the chapter "Setting the pressure switch".
3. RANGE OF USE
The typical areas of use of booster sets include: Automatic domestic water supply with grey water (according to the versions) from wells and cisterns, automated irrigation of gardens and garden beds and sprinkling, pressure boosting within the domestic water supply system. The device is not suited for use in swimming pools. This product is intended for
private use in the home area and not for commercial or industrial purposes or for continuous circulating.

The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or other hazardous liquids.
Please observe the max. and min. temperatures of the liquids to be discharged stated in the technical data.
4. SCOPE OF DELIVERY
The scope of the delivery of this product includes: one booster set with a connection cord, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional accessories may be necessary (see Chapter 7, 8 and 9).
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an environmental-friendly manner.
5. INSTALLATION
5.1. GENERAL INSTALLATION INFORMATION

During the entire process of installation, the device must not be connected to the electrical mains.

The pump should be installed in a dry place with an ambient temperature not to exceed 40^ and not to fall below 5^ . The pump entire connection system have to be protect-frost and other climatic influences.

When installing the device, please make sure that the motor is sufficiently ventilated.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the pump and cause considerable damage. Therefore, please use Teflon tape to seal the contact surfaces between the threaded sections of the lines and the connection with the pump. This use of sealing material such as Teflon tape is the only way to ensure an airtight assembly.
When tightening threaded connections, please do not apply excessive force which may cause damage. When laying the connection pipes, you should make sure that the pump is not exposed to any form of weight, vibration or tension. Moreover, the connection lines must not contain any kinks or an adverse slope.
Please observe the illustrations, too, which are contained in the present operating instructions. The numeric and other details included in brackets below refer to these illustrations.
5.2. INSTALLATION OF THE SUCTION LINE

The intake of the suction line has to be equipped with a check valve 3A (or non
return valve) and an intake filter.
It is mandatory to install a second non-return valve between the suction pipe and the pump.
This valve prevents leakage on the suction line causes continuous operation of the pump.
Please use a suction line (1) having the same diameter as the suction port (6) of the pump. If the suction height (HA) exceeds 4m , however, it is recommendable to use a 25% larger diameter - including appropriate reducer elements for the connectors.
The intake of the suction line has to be equipped with a check valve 3A - or non-return valve - and an intake filter (2). The filter will keep away larger dirt particles contained in the water which might clog or even damage the piping. The check valve will prevent the pressure to escape after the pump has cut out. Moreover, it simplifies the venting of the suction line by enabling water to be filled in. The check valve with the intake filter - i.e. the entirety of the intake section of the suction port - must be immersed by at least 0.3m below the surface of the liquid to be pumped (HI). This will prevent air from being taken in. In addition, please ensure a sufficient distance of the suction line from both the ground and the sides of water courses, rivers, ponds etc in order to prevent stones, plants etc from being sucked in.
It is mandatory to install a check valve between the suction pipe and the inlet of the pump.
This non-return valve prevents back pressure in the suction pipe.
5.3. INSTALLATION OF THE PRESSURE LINE
The pressure line (4) conveys the liquids to be discharged from the pump to the point of withdrawal. To avoid dynamic flow losses, one should use a pressure line having at least the same diameter as the pressure port (7) of the pump. Also, to facilitate maintenance work, it is recommendable to install a shut-off cock (5) after the pump and check valve. This is a useful feature since it can be closed when the pump has to be dismantled and will thus prevent the pressure line from draining to empty.
5.4. STATIONARY INSTALLATION

With regard to the electrical connection in the case of stationary installation, please ensure an adequate visibility and accessibility of the plug.
For stationary installation, please fasten the pump on a suitable, solid surface. To reduce vibration, it is recommended to apply an anti-vibration material - for instance a rubble layer - between the pump and the installation surface (16).
5.5. USING THE PUMP FOR GARDEN PONDS AND SIMILAR PLACES

Operating the pump next to garden ponds and similar places is generally only admissible if no persons are in contact with the water.

The use of the pump as a recycling pump or as a closed circuit pump is prohibited.
If the pump is used for garden ponds and similar places it has to be operated using a residual current circuit-breaker (FI switch) with a nominal trigger current of ≤ 30mA . Please ask your electrical services provider whether your installation site complies with this condition.
The pump must not be used in such locations unless it is set up firmly and flood-proof, a minimum distance of two metres away from the border of the water body and secured against falling into the water by a solid holding device. For this purpose the device is to be bolted down firmly to the ground at the fastening points provided (please refer to the chapter titled "Stationary installation").
6. ELECTRICAL CONNECTION

- The unit is equipped with a mains connection cable and a mains plug. It must only be replaced by qualified staff to avoid any danger. Please do not use the mains connection cable to carry the pump, and do not use this cable to pull off the plug from the socket, either. Protect the mains connection cable and mains plug from heat, oil or sharp edges.
- The values stated in the technical details have to correspond to the mains voltage. The person responsible for the installation has to make sure that the electrical connection is earthed in compliance with the applicable standards.
- The electrical connection has to be equipped with a highly sensitive residual current circuit-breaker (FI switch): = 30mA .
- Only use an extension cable with a cable section (3 × 1.0 ~mm^2) and rubber sheath which at least corresponds to that of the unit's own connection cable (see "Technical data", cable type) and which is labelled with the relevant abbreviation according to the VDE (German Association for Electrical, Electronic & Information Technologies). The mains plug and other connections must be splash-proof.
- Pay attention to the illustrations in this manual. The numeric and other details included in brackets
below refer to these illustrations.
- Prior to putting the pump into operation for the very first time, the pump housing should be fully vented - i.e. filled with water - even in the case of self-priming units. If this venting is omitted, the pump will not suck in the liquid to be discharged. It is highly recommendable, yet not mandatory, to vent the intake line as well, i.e. to fill it with water.
- The pump must only be operated in the performance range indicated on the type plate.

Dry-running - i.e. operating the pump without discharging water - is to be avoided since the absence of water may cause the pump to run hot. This may cause considerable damage on
the device. Moreover, this means that very hot water will be enclosed within the system so that there is a hazard of scalding. If the pump has run hot, please pull off the mains plug and allow the system to cool down.
- Please do not expose the pump to moisture (e.g. when operating sprinklers). Do not expose the unit to rain, either. Make sure that no dripping connections are located above the pump. The pump should not be used in wet or moist environments. Make sure that the pump and the electrical plug connections are arranged in a flood-proof place.
- The pump must not be running with the feeder line closed.
- As long as the device is connected to the electrical mains, one must never reach with one's hands into the opening of the pump.
Each time the pump is put into operation, please make sure that the pump is set up securely and firmly standing. The unit must always be positioned upright on an even surface.
Please inspect the pump visually prior to each use. This applies in particular to the mains connection line and the mains plug. Make sure that all screws are firmly tightened, and verify the perfect condition of all connections. A damaged pump must not be used. In any case of damage, the pump has to be inspected by qualified service staff.
Prior to the first time the pump is put into operation, the pump housing (10) has to be fully vented. To do so, please fill the pump housing (10) through the filling opening (8) completely with water. Please check to make sure that no leakage occurs. Subsequently, close the filling opening airtight again. It is highly recommended to vent the suction line (1) as well, i.e. to fill it with water. In this case, however, the pump will require some time before it will have sucked in the liquid to be pumped and proceed to the actual discharging function. In addition, this way of proceeding may require the pump to be filled several times. This depends on the length and diameter of the suction line. After filling, please
open any shutting device (5) in the pressure line, for instance a water tap, to enable the air to escape during sucking in.
Plug the mains plug into a 220-240V AC socket. If the pump is equipped with a switch ON position. The pump will start running immediately. As soon as the liquid is being discharged evenly and without air mixture, the system is ready for operation. You may then close the shutoff valve in the pressure line again. The pump will cut out upon reaching the cutout pressure. If the pump was out of operation for some extended period of time, the steps described above have to be repeated for a renewed putting into operation.
ANTI DRY-RUNNING FEATURE
Some of the SPIDO. booster sets - more specifically, the SPIDO PROTEC series - are equipped with an anti dry-running feature. This protection system prevents the pump from damage which may be caused by its operation with an insufficient water level or by an overheating of the hydraulic system.
If the temperature inside the pump reaches 60 - 70^ , the anti dry-running feature will cut off the power supply of the motor. In this way the pump will cut out, and a warning indicator lamp will light up on the terminal box.
Once the protection system having become activated, the resumption of operation requires the switch at the terminal box to be set to "0". Please pull off the pump's mains plug from the mains socket and allow the entire hydraulic section to cool down. Subsequently, you should eliminate the cause of the malfunction. Then set the switch at the terminal box to "1". Afterwards, plug the pump's mains plug into the mains socket again. If the warning indicator lamp does not light up again, the pump will cut in. However, if the warning indicator actually goes on again, please repeat the above steps to resume operation.
8. SETTING THE PRESSURE SWITCH

Changing the preset cut-in and cut-out pressure must only be done by qualified staff.
The electrical pumps of the SPIDO series will cut in as soon as the cut-in pressure is reached as a result of a pressure drop occurring within the system - as a rule, by opening of a faucet or any other consumer element. Cutting-out occurs after the consumer element concerned has been shut off and the pressure in the system has increased again to reach the cut-out pressure. The pressure switch is ex-factory set (see 2. Technical data). Experience has shown that these values are ideally suited for most installations. Should any modification of these settings be required, please contact your installation or electrical specialist. Any change in the pressure switch setting must be accompanied by an adjustment of the tank air pressure (0.2 bar less than
the starting pressure).
9. PREFILTER (NOT INCLUDED)
Abrasive matters contained in the liquid being discharged - such as sand - accelerate wear and tear and reduce the performance of the pump. When discharging liquids containing such matters, the installation of a prefilter is recommended. This useful accessory it will efficiently filter sand and similar particles out of the liquids, thus minimise wear and tear and extend the lifetime of the pump.
The proper functioning of the filter should be checked on a regular basis. If necessary, please clean replace the filter mesh.
10. MAINTENANCE AND TROUBLESHOOTING

Prior to carrying out any maintenance work, the pump must be separated from the electrical mains. If you fail to separate the
unit from mains, there is a risk of an inadvertent start of the pump.

We decline any liability for damage caused by inappropriate repair attempts. Any damage caused by inappropriate repair
attempts will avoid all warranty claims.
Regular maintenance and thorough care will reduce the danger of possible malfunction and contribute to an extension of the lifetime of your unit.

If you notice that the pump runs continuously without stopping, beyond one minute after closing the valves: check that
the pressure reached on the pressure gauge is higher than the switch stop setting.
YES > contactor problem > contact your dealer
NO > disconnect the pump from the mains and see if the pressure drops by itself while the valves are closed.
YES> the pump is not in question and there is a leak on the suction column that is not watertight (return to the well - leak on pipe or check valve missing or defective) or backflow.
NO> the pump is worn or clogged> contact your dealer.

If you suddenly notice that your booster has ran continuously without interruption (more than 30 minutes), to avoid any risk of burns
or breakage of an accessory:
1- Open the taps to relieve the pressure in the circuit
2- Turn off the pump and allow it to cool
3- Check the installation of the pump: suction line sealing and other accessories, proper operation of the pressure switch.
To prevent possible malfunction, it is recommended to check the occurring pressure and the energy consumption at regular intervals. Also, the pre-pressure (atmospheric pressure) in the pressure tank should be checked regularly. To do so, please
separate the pump from mains, then open any consumer component in the pressure line - for instance, a water tap - to release the pressure from the hydraulic system. Subsequently, unscrew the protection cap of the tank valve (17). On the tank valve, please use a pressure gauge to check the pre-pressure. It should read cut-in pressure -0.2b (ex: 2-0,2=1,8bar), otherwise it has to be corrected. If any water is leaking out of the tank valve, the membrane is defective and should be replaced.
If the device is not in use over some extended period of time, both the pump and the pressure tank should be emptied using the devices provided for this purpose. Water left in the pump may freeze in case of frost and thus cause considerable damage. Please store the pump in a dry, frost- protected place.
In the case of malfunction, you should first of all check whether it was caused by an operating error or some other reason which cannot be attributed to a defect of the device - for instance a power failure.
The list below shows some possible malfunctions of the device, possible causes and tips on their elimination. All the measures referred to may only be carried out with the pump being separated from the electrical mains. If you yourself feel unable to eliminate any of these malfunctions, please contact the customer service department or your point of sales. Any repair beyond the scope specified below must only be performed by qualified staff. Please bear in mind that all warranty claims will become void in the case of damage caused by inappropriate repair attempts, and that we decline any liability for any ensuing damage.
| Malfunction | Possible cause | Elimination |
| The pump is not discharging any liquid, the motor is not running. | No current. | Please use a device complying with GS (German technical supervisory authority) to check for the presence of voltage (safety information to be observed!). Please verify. |
| Thermal motor protection feature has triggered. | Separate the pump from the electrical mains, allow the system to cool down, eliminate cause. | |
| The capacitor is defective. | Please contact the customer service department. | |
| The motor shaft is jamming. | Check the cause, eliminate the reason for the jamming of the pump. | |
| Wrong setting of the pressure switch. | Please contact the customer service department. | |
| The motor is running, but the pump is not discharging any liquid. | The pump housing is not filled with liquid. | Fill the pump housing with liquid (please refer to "Putting into operation" section). |
| Air penetrates into the intake line. | Check to make sure that :a.) the connection points of the intake line are tight.b.) the inlet opening of the intake line including the check valve (non-return valve) are immersed into the liquids being discharged.c.) the check valve (non-return valve) with the filter is tight and not jammed.d.) no siphons (i.e. permanently liquid-filled loops), kinks, counter-slopes or narrow spots are present along the intake lines. | |
| Suction height and/or discharge height too great. | Change the arrangement of the installation so that the suction height and/or discharge height will not exceed the max. value. | |
| The pump stops after a short time of operation because the thermal motor protection feature has triggered. | The electrical supply does not correspond to the information given on the type plate. | Please use a device complying with GS (German technical supervisory authority) to check the voltage of the lines of the connection cord (safety information to be observed!). |
| Pump or intake line are blocked by solids. | Remove possible congestion. | |
| Liquid is too viscous. | Pump may not be suitable for this liquid. If feasible, the liquid should be thinned. | |
| Temperature of liquid or environment is too high. | Make sure that the temperature of the liquid being pumped and the environment do not exceed the max. admissible values. | |
| Pump is running dry. | Eliminate causes of dry-running. | |
| The pump cuts in and out too frequently. | The membrane of the pressure tank is damaged. | Have the membrane or the entire pressure tank replaced by qualified staff. |
| Insufficient pressure in the pressure tank. | Use the tank valve to increase the pressure until it reaches the needed value. Before that, please open a consumer in the pressure line (e.g. a faucet) to depressurise the system. | |
| Air penetrates into the intake line. | Refer to section 2.2. | |
| Check valve (non-return valve) is jammed or not tight. | Eliminate the cause of blocking the check valve (non-return valve) or replace it if damaged. | |
| The pump does not reach the desired pressure. | Pump is blocked | Please contact the customer service department. |
| Air penetrates into the intake line. | Refer to section 2.2. | |
| The pump does not cut out. | Cut-out pressure set too low. | Please contact the customer service department. |
| Air penetrates into the intake line. | Refer to section 2.2. |
11. WARRANTY - SERVICE
This pump is guaranteed 2 years from the day of purchase. This warranty includes the free replacement of defective parts or the device, the choice being left to the free initiative of the seller, subject to use in accordance with the instructions.
This guarantee also covers all the consequences of defects or hidden defects (article 1641 and following of the Civil Code).
Conditions of validity of the guarantee: The appliance must always have been handled correctly, according to the instructions in this manual. The unit must not have been modified or repaired or otherwise serviced by anyone other than the Authorized Service Center.
The warranty no longer applies in the following cases:
-
Non-compliance with the instructions (in particular no protection against frost, sand pumping, dry running, incorrect electrical connection ...)
-
Attempt to repair the device
- Technical modifications of the device
- Use of spare parts other than original ones.
- Damage / malicious acts (falling or signs of shock on the device).
- Inappropriate use (ex: industrial use, continuous operation), and in particular: passage of hard and heavy particles (pebbles), passage of an excessive amount of sand, salt water, water with high content of limestone...
- Failure to maintain or clean
Parts excluded from the warranty, beyond the first 6 months (in case these parts are supplied with the pump): hanging line, fitting, drain hose, butt and discharge rod, valve, plugs, filter wrench, filter and tank bladder.
An intervention under warranty or exchange by a new product during the warranty period does not extend the initial warranty period.
Support for devices under warranty is provided by the product dealer. The product must be accompanied by all its accessories and the receipt or the original invoice and a letter explaining the reason for the return or the symptoms of failure noted.
PLEASE NOTE :
- Should your device fail to function properly, please verify first whether an operating error or another cause is present which cannot be attributed to a defect of the device.
-
In case you have to take or send in your defective device for repair, please be sure to enclose the following documents :
-
Sales receipt (sales slip)
-
A description of the occurring defect (a description as accurate as possible will expedite the repair work).
- In case you have to take or send in your defective device for repair, please remove any attached parts which do not belong to the original condition of the device. If any attached parts of this kind should be missing upon the return of the device, we shall not be liable for them.
For a list of available parts, please contact your dealer.
DIPRA is working to supply main spare parts of this pump during 5 years, starting from the construction date of the pump written on the rating label
In the case of warranty claims or malfunction, please contact your point of sale. Repair from After Sale Service during the guarantee does not extend its initial duration.

For EC countries only
Do not throw electric appliances in your dustbin!
According to EU guideline 2012/19/EU concerning old electric and electronic appliances and its implementation in national law, such appliances must be collected separately and fed into an environment-friendly recycling system. Please consult your local waste management system for advice on recycling.

EasyManual