Product type Mobile air conditioner "all in one"
Brand VORTICE
Model ARTIK M12
Power supply 230-240 V ~ 50 Hz (check the rating plate)
Operating modes Cooling, Fan, Dehumidification, Auto, Super Cool
Fan speeds Low, Medium, High
Temperature range 0 °C to 50 °C (display), default setting 24 °C
Timer Programmable from 1 to 24 hours (delayed start or stop)
Night function Automatically increases temperature by 1 °C per hour for 2 hours, minimum speed, stops after 12h
Remote control Yes, with 3V lithium battery type CR2025
Self-diagnosis Displays E1 or E2 in case of anomaly
Cooling modes Normal and Super Cool (with water tank)
Condensation tank Manual drain or continuous drainage with provided hose
Hot air exhaust hose Extendable length from 300 to 1500 mm, do not extend further
Filters Washable air filter + activated carbon filter (supplied)
Maintenance Clean the body with a damp cloth (water < 40°C, mild soap); clean filters with vacuum or water (< 40°C)
Safety Do not use outdoors; do not cover; unplug before cleaning; wait 3 min before restarting; do not use without filters
Spare parts and repairability Use original Vortice parts; entrust repairs to an authorized service center
Electrical installation Proper grounding; do not use adapter or extension cord
Included accessories Flexible hose, window panels, round connector, cap, remote control, activated carbon filter, drainage hose, Super Cool tank

Frequently Asked Questions - ARTIK M12 VORTICE

How to install the hot air exhaust hose?
Mount the round connector (13) on the end of the flexible hose (10). Insert the assembly into the perforated panel (12) or directly into a hole with diameter > 152 mm in a wall or window. Use the cap (14) to seal the hole when the appliance is not in use.
What to do if the condensation tank is full?
The Condensation tank full indicator lights up and the appliance emits a beep. Turn off the appliance, place a container under the drain outlet, remove the rubber cap to empty the water, then replace the cap and turn on again. For continuous drainage, connect the provided hose to the outlet and place the other end at a lower drain.
How to activate Super Cool mode?
The Super Cool mode requires the special tank to be full of water. Open the door, extract the tank, fill it with water and replace it. Super Cool mode activates automatically when conditions allow.
Why is the air conditioner not working?
Check that the plug is properly inserted, there is no power outage, the tank full indicator is not flashing, and the ambient temperature is higher than the set temperature. If nothing works, contact an authorized Vortice service center.
How to clean the filters?
Use a vacuum cleaner or gently shake the filters to remove dust. Rinse them with cold water (< 40°C), let them dry completely before reinstalling. Never operate the appliance without filters.
What is the function of the remote control?
The remote control allows you to control all functions of the air conditioner: on/off, mode, speed, temperature, timer and Night function. It uses a 3V lithium battery type CR2025.
Can I use the air conditioner outdoors?
No, the appliance is designed for indoor use only. Do not expose it to rain, sun or other weather conditions.
How long should I wait before restarting the air conditioner?
To protect the compressor, wait at least 3 minutes before restarting the appliance after turning it off.
What to do if the display shows 'E1' or 'E2'?
These codes indicate a malfunction. Turn off the appliance and contact an authorized Vortice after-sales service for inspection.
How to set the timer?
Press the TIMER button to set the operating time (1 to 24 hours). The appliance will turn off automatically at the end of the period. When it is off, the timer is used to set a delayed start.

User questions about ARTIK M12 VORTICE

2 questions about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

How to clean and maintain the VORTICE ARTIK M12 air conditioner?
Frequently Asked Questions - 28 d
Response Notice-Facile

Cleaning the unit's body

Before any operation, unplug the device from the electrical outlet.

Use a cloth dampened with lukewarm water (less than 40°C) and neutral soap. Avoid solvents or aggressive detergents that could damage the casing.

Filter maintenance

The filters should be cleaned regularly:

  • Use a vacuum cleaner or gently shake the filters to remove dust
  • Rinse them with cold water (maximum temperature 40°C)
  • Allow them to dry completely before reinstalling

Warning: Never turn on the device without the filters in place.

Condensation tank management

The tank can be emptied manually by removing the rubber plug and letting the water flow into a container. You can also connect the provided hose to the drainage outlet for continuous drainage - position the other end of the hose lower than the outlet.

End-of-season maintenance

Before long-term storage:

  • Unplug the device and wrap the power cord in its compartment
  • Completely empty the condensation tank
  • Clean the filters
  • Run the device in fan mode for several hours during good weather for complete drying
  • Store the device in its original packaging, without heavy objects on top
Respond (be the first)
What are the characteristics of the VORTICE ARTIK M12 drainage pipe?
Frequently Asked Questions - 06/22/2026
Response Notice-Facile

Diameter: The pipe connector must fit into a hole with a diameter greater than 152 mm.

Length: The flexible pipe provided with the device can be extended from 300 to 1500 mm. The manual recommends using the minimum possible extension to avoid any malfunction.

Important: The length of the pipe has been specifically calculated according to the specifications of the ARTIK M12. It is not recommended to replace or extend it beyond these limits, as this could alter the performance of the device.

Related accessories:

  • Round connector - to be mounted on the end of the pipe
  • Cap - to seal the drainage hole when the device is not in use
  • Window panels - to facilitate installation

Commercial references: No specific reference for the pipe is mentioned in the manual. For replacement parts, contact an authorized Vortice service with your ARTIK M12 model reference.

Respond (be the first)

Download the instructions for your Portable air conditioner in PDF format for free! Find your manual ARTIK M12 - VORTICE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ARTIK M12 by VORTICE.

USER MANUAL ARTIK M12 VORTICE

COD. 5.471.084.074

22/01/2014

Before installing and using your product, read these instructions carefully. Vortice will not accept any responsibility for damage to property or personal harm resulting from failure to abide by the conditions listed below. Following these instructions will ensure long service life and overall electrical and mechanical reliability. Keep this instruction booklet in a safe place for reference purposes.

Table of Contents EN

Description and operation....12

Safety....12

Tips for saving electricity....13

Components 13

Installation 14

Function....16

Removing condensation 18

Maintenance/Cleaning....18

Trouble-shooting 19

Important information regarding

eco-compatible disposal....19

Élimination condensation 26

Entretien / Nettoyage....26

1 pannello comandi;

Line drawing of a server unit connected to a cable or hose, no text or symbols present

Line drawing of a car air conditioner unit connected to a horizontal pipe with a circular valve (no text or symbols)

ITALIANO

N.B:

ITALIANO

- estrarre la tanica, aprirla tramite la manopola (fig 19) e riempirla d'acqua;

Line drawing of an air conditioner unit with open doors and a smaller device (no text or symbols)

ITALIANO

Smaltimento condensa

Description and operation

VORT-KRYO POLAR 10, 12 “all in one” portable air-conditioning units are self-contained systems that can be deployed as and when needed.

Safety

VORTICE ARTIK M12 - Safety - 1

Attention:

this symbol indicates that care must be taken to avoid injury to the user

  • Do not use this appliance for functions other than those described in this booklet.
  • After removing the appliance from its packaging, ensure that it is complete and undamaged: if in doubt, consult a Vortice certified technical support centre. Do not leave packaging within the reach of children or differently able persons.
  • Do not sit or place any object on the unit.
  • Certain fundamental rules must be observed when using any electrical appliance including: never touch appliances with wet or damp hands; never touch appliances while barefoot; never allow children or unsupervised differently able persons to use it.
  • This appliance is not suitable for use by children or by individuals with reduced physical, sensorial or mental capacities or by inexperienced or untrained individuals, unless they are supervised or instructed in its use by a person responsible for their safety. Children must always be supervised to ensure that they do not play with the appliance.
  • Do not us the appliance near inflammable substances and vapours (alcohol, insecticides, petrol, etc.).
  • If you decide to stop using the appliance, switch it off and disconnect it from the power supply. Put the appliance away, out of the reach of children or differently able persons.

VORTICE ARTIK M12 - Attention: - 1

Caution:

this symbol indicates that care must be taken to avoid damaging the appliance

  • Do not make modifications of any kind to this appliance.
  • Do not use the appliance outdoors.
  • To protect the compressor from damage, once the appliance has been switched off, it is best to wait at least 3 minutes before turning it on again.
  • Do not expose the appliance to the elements (rain, sun, etc.)
  • Always use and transport the appliance in the vertical position.
  • Do not use the appliance if it is less than 50 cm from a wall, a piece of furniture or curtains.
  • Do not cover the appliance intake or outlet grilles.
  • Do not leave objects standing on the appliance.

  • Do not use the appliance in damp or wet conditions.

  • Do not move drag the appliance from one position to another by the power cable.
  • If the power cable is damaged, have it replaced immediately by an authorised Vortice Service Centre.
  • When the appliance is not being used, switch it off and disconnect the plug from the power supply.

- Always use and transport the appliance in the vertical position.

- Regularly inspect the appliance for defects. If the appliance does not function correctly, switch it off and contact the Vortice Service Department immediately.

- The electrical system to which the appliance is connected must conform to applicable standards.

- The appliance must be connected to an efficient earthing system in accordance with applicable electrical safety standards.

- If in doubt, ask a qualified electrician to check your system.

- Only connect the appliance to the mains if the system can meet the maximum electrical power demanded by the unit.

- If the power socket is of a different type to the plug fitted to the appliance, ask a qualified technician to replace the plug with one of the right type. Avoid the use of adapters, multiplugs and/or extensions.

- Do not pull on the power cable or place it near sources of heat and always uncoil it completely to prevent dangerous overheating.

- Should the appliance be dropped or receive a heavy blow, have it checked immediately at a Vortice Service Department.

- If the appliance does not function correctly and/or develops a fault, turn it off and contact a Vortice Service Department immediately. Make sure that only genuine original Vortice spares are used for any repairs.

• Always turn the unit off when it is not in use.

- Never use the plug to turn the appliance on and off. Always use the switch on the control panel.

- Do not use this appliance without filters.

- Specifications for the power supply must correspond to the electrical data on the product ID plate A (fig.1)

ENGLISH

1
A

Tips for saving electricity.

  • Do not use the appliance rooms that are bigger than the recommended volume (model 10 - 60 m 3 , model 12 - 72 m 3 ).
  • Keeps doors and windows closed.
  • Keep blinds and shutters closed when the sun is at its hottest.
  • Make sure the filters are always clean (See Maintenance/Cleaning).
  • When the required room temperature has been reached, turn the temperature and fan speed settings down.

Components

Front (fig.2)
2
Diagram of a portable air conditioner unit with numbered parts labeled 1 to 4

1 Control panel;
2 Cold air outlet grille;
3 Handle;
4 Wheels;

Rear (fig 3)
3
Labeled diagram of an air conditioner unit with numbered parts for identification

5 Air filter;
6 Air intake grille;
7 Cable housing;
8 Hot air outlet grille;
9 Condensation drainage hole with plug;

Accessories supplied (fig.4)
4
Diagram showing labeled components of a flexible hose and solar panel, including parts numbered 10 to 17.

10 Hot air extraction hose
11 Window panel (to be fitted to the space left for the hot air extraction hose);
12 Window panel (to be fitted to the space left for the hot air extraction hose) with a hole for fitting the hose;
13 Rounded connector for the hose, to be fitted to the hole in the window or in the wall where the hot air is to be extracted from;
14 Blanking cap for connector mentioned in point 13;
15 Remote control unit;
16 Active carbon filter;
17 Condensation drainage hose;

ENGLISH

Installation

Installation of hot air extraction hose. Use the window panel (fig.5)

5 36 cm

The hot air extraction hose supplied with the appliance can be extended by 300 to 1500 mm (figs 7,8); It is best to use the smallest possible extension (fig.9).

Line drawing of a computer tower connected to a ring and cable (no text or symbols)

  • Fit the rounded connector (13) to the end of the hose (10).
  • Insert the end of the hose into the hole in the panel (12).
  • If the panel is too big, cut it to fit the window.
  • Extract the hot air through the window or wall (fig.6)

6 36 cm

  • Fit the rounded connector (13) to the end of the extraction hose.
  • Make a hole (of more than 152 mm diameter) in the window or wall to accommodate the rounded connector.

When the appliance is disconnected from the window or wall, use the blanking cap (14) to cover the hole.

Line drawing of a desktop air conditioner unit connected to a wall-mounted cable (no text or symbols)

Line drawing of a mechanical device with a valve and circular component (no text or symbols)

ENGLISH

Take care not to form kinks in the hose (fig.10) where hot air could be trapped and then on escaping set off the automatic thermal cut-out system.

Line drawing of a car air conditioner unit connected to a wall-mounted device with a circular symbol (no text or labels)

N.B.

The length of the hose has been carefully calculated to match the specifications of the appliance. You are advised not to replace the hose or extension as this may lead to a fault developing.

Fitting the active carbon filters

Remove the filter holder frame from the appliance (fig.11)

11

Remove the filter fastening device from the frame (fig.12)

Diagram showing two panels of a solar panel with an arrow indicating transformation (no text or symbols)

Remove the filter from its packaging (fig.13)

Line drawing of a solar panel with a bandage, no text or symbols present

ENGLISH

Insert the filter into the frame (fig.14)

14

Fit the filter and reassemble the fastening device (fig.15)

15

Refit the filter holder to the appliance

Function

Control panel (fig.16)

16 23 9 2 10 3 11 4 22 21 8 20 19 VORTICE 5 18 7 17 16 15 14 13

Buttons

1 On/off
2 Timer
3 "Night time" function
4 Temperature "UP"
5 Temperature "DOWN"
7 Operation mode
8 Fan speeds

Indicators

9 Power Supply

10 Timer

11 "Night" function

13 Display

14 Slot for receiving signal from remote control unit

15 Fan mode

16 Dry mode

17 Cooling mode

18 Automatic mode

19 Minimum speed

20 Medium speed

21 High speed

22 Condensation tank full

23 Compressor on

Functions

Switching On/Off

Press ON/OFF: the appliance comes on in Cooling Mode at minimum speed; the preset temperature is 24° C

All the indicator lights come on at the same time; the display shows ambient temperature from 0° C to 50° C to turn the appliance off, press the ON/OFF button.

Setting operating mode

Press the MODE button to select the required operating mode: Fan, Dry, Cooling, Auto. The indicator light for the mode selected will come on.

If the room temperature drops below the set limit, the Cooling Mode automatically cuts out and the appliance continues to operate in Fan Mode at the preset speed. If room temperature rises to above the preset limit, the appliance automatically goes back to Cooling Mode.

Setting the temperature

Use the Temperature “UP” and Temperature “DOWN” buttons to set the required temperature.

While the temperature is being set, the display shows the reading. When a temperature has been set, the display will return to showing room temperature.

The appliance preset temperature is 24° C

Setting fan speed

Press SPEED to select the required fan speed setting: Minimum, Medium, Maximum. The indicator light for the mode selected will come on at the same time.

ENGLISH

Setting the timer

Press TIMER to set the required operating time (from 1 to 24 hours): the Timer light will come on and the display will show how long the appliance is set to run for. After this period, the appliance will switch itself off automatically.

By pressing the button when the appliance is switched off, the appliance can be set to start at a later time. (e.g. pressing 2 means the appliance will start working 2 hours later)

Setting Night mode

If you press SLEEP while the appliance is in Cooling Mode, the preset temperature will increase by 1° C after one hour and by a further 1° C after the second hour.

In “Night” mode, fan speed is automatically set to its lowest level. Pressing SLEEP again, the temperature and fan speed return to their preset levels.

N.B.

The appliance switches itself off automatically after operating for 12 hours of continuous running in Night mode.

N.B.

Night mode can only be activated if the appliance is in Cooling mode i.e. it is not an option in Fan or Dry operating mode.

Auto-diagnosis

The appliance can carry out auto-diagnosis. In the event of a malfunction, the display on the control panel will show “E1” or “E2”. In such event, contact an authorised Vortice Service Centre.

N.B.

All the functions mentioned above can be activated from the remote control unit provided (fig.17).

17 788°C 22h SLEEP MODE SPEED SPEED TEMP TIMER

Use 3 Volt (CR2025) lithium batteries in the remote control unit.

"Super Cool" mode

To ensure that the appliance works properly in

"Super Cool" mode, make sure that the tank is filled.

The procedure is as follows:

- remove the tank, open the lid with the handle (fig.19) and fill it with water;

19
Line drawing of an air conditioner unit with open doors and a separate close-up view (no text or symbols)

- replace the tank.

The filter can be removed and cleaned (fig. 20).

20
Technical line drawing of a portable air fryer with internal components and ventilation slots (no text or symbols)

ENGLISH

Removing condensation

When the appliance is operating in Cooling or Dry mode, humidity extracted from the air is collected in an internal tank. If the tank reaches full, the compressor and motor cut out automatically. At the same time, the “condensation tank full” light comes on. An alarm will also sound. When the tank is full, carry out the following instructions: (fig.21)

21
Diagram of a device with a cable being inserted into a box, showing mechanical components and motion arrows (no text or symbols)

1 Turn the appliance off taking care not to move it so as to prevent spilling water from the tank.
2 Place a basin under the appliance drain hole.
3 Remove the drain handle and the rubber cap to let the condensation flow out.
4 When the basin is nearly full, replace the rubber cap and empty the basin.
5 Repeat as above until the condensation tank is empty.
6 Replace the rubber cap and handle.
7 Turn the appliance on again. The “condensation tank full” light should now be off.
Should you prefer to use the appliance without having to empty the tank every so often, proceed as follows: (fig.22)

22
Line drawing of a device with a handle and cable, showing no text or symbols

1 Remove the drain handle and the rubber cap and set them aside for future use.
2 Connect one end of the continuous condensation drainage hose (supplied) to the appliance drain hole and place the other end in a drain.
3 The hose can be connected to an extension hose that has an external diameter of 18mm.

N.B.

Needless to say, the drain must be at a lower level than the drain hole on the appliance. Should you opt for continuous drainage, the “condensation tank full” light is deactivated.

Maintenance/Cleaning

Cleaning the appliance body

N.B.

Before starting any cleaning work, remove the plug from the main socket.

Clean the appliance with a damp cloth, warm water (no hotter than 40° C) and a neutral detergent. Do not use aggressive solvents or detergents.

Cleaning the filters

Use a vacuum cleaner or delicately shake the filters to remove any dust. Next rinse the filters under running water (no hotter than 40° C) and allow them to dry before refitting.

N.B.

Never turn the appliance on without the filters.

End of season servicing

Remove the plug and rewind the cable (fig.23).

23
Technical line drawing of a portable air conditioner unit with ventilation grilles and cooling fans (no text or symbols)

Completely empty the condensation tank.

Clean the filters.

On a warm day, turn the appliance on for several hours in Fan mode to thoroughly dry the inside of the unit.

You are advised to use the original packaging materials and not to place heavy items on top of the appliance.

ENGLISH

Trouble-shooting

In the event of malfunction, before contacting an authorised Vortice Service Centre, you are advised to carry out the following checks:

The appliance is not working

Is it plugged in?

Is there a power failure?

Are the compressor or “condensation tank full” lights flashing?

Is room temperature lower than the set level?

The appliance is not performing well

Is sunlight entering and heating the room? (If so, close the curtains, if present)

Are there doors or windows open?

Is the room over-crowded?

Is there a source of heat in the room?

The appliance works but seems to have no effect

Is the filter dirty or blocked?

Are the inlet and/or outlet grilles obstructed?

Is room temperature lower than the preset level?

The appliance is very noisy

Is the appliance sitting on the level or in an unusual position that may give rise to vibration?

Is the floor level?

The compressor is not working

The compressor thermal cut-out may have been activated due to excessive room temperature. Wait for a few minutes then try to restart the appliance

N.B.

Never attempt to repair or dismantle the appliance, Always contact an authorised Vortice Service Centre.

Important information on eco-compatible disposal

IN CERTAIN EUROPEAN UNION COUNTRIES THIS PRODUCT DOES NOT FALL WITHIN THE REQUIREMENTS OF THE NATIONAL LAWS IMPLEMENTING DIRECTIVE RAEE, AND IN THESE COUNTRIES THE PRODUCT IS NOT SUBJECT TO SEPARATE DISPOSAL OPERATIONS AT THE END OF ITS WORKING LIFE.

This product complies to European Directive 2002/96/EC.

At the end of its useful life, the product marked with the crossed out wheeled bin must be disposed of separately from urban waste. It must be taken to a differentiated disposal centre for electrical and electronic appliances or be returned to the retailer when a new equivalent appliance is bought.

VORTICE ARTIK M12 - Important information on eco-compatible disposal - 1

Subject to current legislation on waste disposal, the user is legally responsible for taking the appliance at the end of its useful life to a suitable disposal centre.

Appropriate differentiated waste collection for subsequent recycling, treatment and environment-friendly disposal of the discarded equipment helps to prevent possible negative environmental and health effects and encourages recycling of the component materials of the equipment.

For further information about available waste disposal systems, contact your local waste disposal service or the shop where you bought the product.

The manufacturers and importers comply with their responsibility for recycling, treating, and environmentally compatible disposal of waste both directly and collectively.

FRANÇAIS

Line drawing of a desktop air conditioner unit connected to a wall-mounted cable (no text or symbols)

Line drawing of a steam fan with a valve and circular component (no text or symbols)

FRANÇAIS

N.B :

FRANÇAIS

FRANÇAIS

Élimination condensation

1 Bedienblende

Line drawing of a server unit connected to a cable, showing internal components and wiring (no text or symbols)

Line drawing of a mechanical device with a valve and circular component (no text or symbols)

DEUTSCH

Achtung:

DEUTSCH

DEUTSCH

DEUTSCH

Line drawing of a server rack connected to a cable, no text or symbols present

Line drawing of a mechanical device with a valve and circular component (no text or symbols)

ESPAÑOL

NOTA:

Extraer el filtro del envase (fig.13)

13
Line drawing of a solar panel with a blade extending from its side (no text or symbols)

ESPAÑOL

ESPAÑOL

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : VORTICE

Model : ARTIK M12

Category : Portable air conditioner