Product type Wall-mounted hood
Brand FALMEC
Model QUASAR MURALE
Use Above domestic cooktops
Minimum distance above a gas hob 65 cm
Evacuation version Extractor (external evacuation) or air recirculation (charcoal filters)
Number of motor speeds 3 + 1 timed intensive speed
Automatic shut-off timer Yes, 15 minutes
Lighting Halogen, max 20 W, 12 V, G4 base
Metal grease filters Washable, monthly cleaning recommended
Activated charcoal filters Replacement every 3-4 months depending on use
Filter saturation alarm Yes, after approximately 30 hours of operation
Remote control Optional (available on certain versions)
Exterior maintenance Soft cloth, neutral soap or denatured alcohol
Interior maintenance Do not clean electrical parts with liquids or solvents
Safety Mandatory grounding, safety distance, do not use with open flame
Electrical supply See rating plate inside the hood
Warranty Yes, conditions on the back of the manual
Maximum weight of suspended objects 1.5 kg
Installation By a qualified installer, wall support bar

Frequently Asked Questions - QUASAR MURALE FALMEC

What is the minimum distance between the hood and the hob?
The minimum distance between the highest part of the cooking appliance and the lowest part of the hood must be at least 65 cm for a gas cooker. Check the instructions of your cooking appliance if they are higher.
How to clean the metal filters?
The metal grease filters should be cleaned every month in hot water with a little detergent. Avoid bending them and let them dry completely before reassembling.
When should the activated charcoal filters be replaced?
Activated charcoal filters cannot be washed and must be replaced on average every 3 to 4 months, depending on use. Follow the instructions in point H2 of the manual for replacement.
What does the red light on the timer button mean?
The red light indicates that the metal filters need cleaning. It comes on after approximately 30 hours of operation. To deactivate the alarm, press the timer button for a few seconds until the red light goes out.
Can I use the hood without external evacuation?
Yes, the hood can operate in air recirculation mode by installing activated charcoal filters. In this mode, the air is purified and returned to the kitchen. Remove the non-return valve when switching to filtration mode.
How to use the optional remote control?
The remote control allows you to control the light (light button), speeds (+ and -), and the timer. Maximum range 5 meters. In case of interference, you can change the remote control code (see manual).
How to change the hood bulb?
First unplug the appliance. Open the panel fully by pressing PUSH. Replace the halogen bulb (max 20 W, 12 V, G4 base) with a similar lamp. Close the panel.
What to do if the panel does not close properly?
If the panel does not close, repeat the full opening operation by pressing PUSH to the indicated angle (see figure), then close again. Check that nothing obstructs the closure.
Can the hood be used simultaneously with gas appliances?
Yes, but make sure the room is sufficiently ventilated. When the hood operates with other combustion appliances, the depression in the room must not exceed 4 Pa (in accordance with standards).
How to deactivate the filter saturation alarm?
To deactivate the alarm (red light), press the timer button for a few seconds until the red light goes out. Turn off and then on the hood to check that the alarm has disappeared.

User questions about QUASAR MURALE FALMEC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Wall hood in PDF format for free! Find your manual QUASAR MURALE - FALMEC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. QUASAR MURALE by FALMEC.

USER MANUAL QUASAR MURALE FALMEC

INSTRUCTIONS BOOKLET

Dear Sir/Madam, congratulations!

You have purchased a prestigious range hood of guaranteed quality. For best results, we suggest that you carefully follow the operating and maintenance instructions provided in this booklet; in addition, to order spare charcoal filters, use the special coupon on the cover.

FALMEC QUASAR MURALE - 1

WARNINGS

FALMEC QUASAR MURALE - WARNINGS - 1

This instruction booklet must be kept together with the appliance for future reference. If the appliance is sold or consigned to other parties, check that the booklet is supplied with it, to ensure that the new user has the correct information on the operation of the range hood and is aware of the warnings. These warnings have been provided for your safety and the safety of others. As a result, please read them carefully before installing and operating the appliance.

This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely. Young children should be supervised to ensure they do not play with the appliance.

The appliance must be installed by qualified personnel, in accordance with the standards in force. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Any modifications that may be required to the electrical system for the installation of the range hood must only be made by qualified electricians.

It is dangerous to modify or attempt to modify the characteristics of this system. In the event of malfunctions or if repairs are required to the appliance, do not attempt to solve the problems directly.

Repairs performed by unqualified persons may cause damage. For all repair and other work on the appliance, contact an authorized service/spare parts center.

Always check that all the electrical parts (lights, exhaust device) are off when the appliance is not being used. Read the entire instruction booklet before performing any operations on the range hood.

The range hood must only be used for the exhaust of cooking fumes in home kitchens. The manufacturer disclaims all liability for any other use of the appliance.

The maximum weight of any object placed above the hood, or hung to it (if possible) must not exceed 1.5 kilos. After installing the stainless steel hood, clean it in order to remove any residue of the protective glue, and stains of grease or oil. The manufacturer recommends its cleaning cloth available for purchase. The manufacturer accepts no liability in case of damage caused by the use of different detergent types.

FALMEC QUASAR MURALE - WARNINGS - 2

TECHNICAL SPECIFICATIONS

The technical data pertaining to the electric appliance. The technical specifications of the appliance are shown on the rating plates located inside the range hood.

(Section reserved for qualified installers of the range hood)

Minimum distance: distance between the pan supports of the cooker and the bottom-most section of the hood. When the hood is positioned above a gas equipment this minimum distance must be at least 65 cm (see picture C1) or even more, if this is specified in the instructions for use of the gas cooker.

In the outside exhaust version, the diameter of the fume discharge duct must be no smaller than the range hood connection.

In the horizontal sections, the duct must slope slightly (around 10%) upwards, so as to better convey the air outside of the room.

Avoid using angled pipes, make sure that the pipes are at least of the minimum length.

Comply with the current regulations on air discharge into the atmosphere. If a boiler, stove, fireplace, etc. that uses gas or other fuels is being used at the same time, make sure the room where the fumes are extracted is well ventilated, in compliance with the current regulations.

Mounting instruction: see section "O" of the booklet.

FALMEC QUASAR MURALE - (Section reserved for qualified installers of the range hood) - 1

ELECTRICAL CONNECTIONS

(Section reserved for qualified installers)

WARNING!

Before doing any work inside the range hood, disconnect the appliance from the mains power supply.

Check that the wires inside the range hood are not disconnected or cut; if this is the case, contact your nearest service centre. The electrical connections must be performed by qualified personnel.

The connections must be performed in compliance with the legal standards in force. Check that the relief valve and the electrical system are able to support the load of the appliance (see the technical specifications in point B).

Some types of appliance are supplied with a cable without plug; in this case, "standardised" plugs must be used, keeping in mind that:

  • the yellow-green wire must be used for the earth,
  • The blue/white wire must be used for the neutral.
  • The brown/black wire must be used for the phase; the cable must not come into contact with hot parts (over 75°C).
  • Fit a plug that is suitable for the load to the power cable, and connect it to a suitable power outlet.

For appliances that come supplied with cable and plug, please ensure they are plugged into a circuit suitable for this appliance.

Please refer to a qualified person. (See technical specifications in point B).

The manufacturer declines all liability if the safety standards are not observed.

FALMEC QUASAR MURALE - WARNING! - 1

RANGE HOOD WITH OUTSIDE

DISCHARGE (exhaust)

In this version, the fumes and steam from the kitchen are conveyed outside through an exhaust duct.

The exhaust conveyor that protrudes from the upper part of the range hood must be connected to a duct that carries the fumes and steam outside. In this version, the charcoal filters, if fitted, should be removed; to do this, see the instructions in point F. There must be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels, according to the standard.

Deviation for Germany:

When the range hood and appliances supplied with energy other than electricity are simultaneously in operation, the negative pressure in the room must not exceed 4 Pa (4x10 E-5 bar).

FALMEC QUASAR MURALE - DISCHARGE (exhaust) - 1

RECIRCULATING RANGE

HOOD (with filter)

In this version, the air passes through charcoal filters for purification, and is then recirculated back into the kitchen.

Check that the charcoal filters are fitted to the motor, and if not, install them as described in the instructions in point H.

If the hood is of filtering type, remove the non-return valve fitted at the motor's outlet.

FALMEC QUASAR MURALE - HOOD (with filter) - 1

For maximum efficiency, the third speed should be used when there are strong odours or a lot of steam, the second speed in normal conditions, and the first speed for keeping the air clean with minimum energy consumption.

The range hood should be switched on when starting to cook, and left on until the odours disappear.

FALMEC QUASAR MURALE - HOOD (with filter) - 2

OPERATION

1. ELECTRONIC CONTROL PANEL (Quasar Top)

Light pushbutton

  • ON: light on (the pushbutton is lit);
  • OFF: light off;

Pushbutton -

Press to reduce motor speed

Speed 1, 2 and 3 are indicated by the number of LEDs that light up (excluding the light and the timer LEDs).

Pushbutton +

Press to increase motor speed

Speed 1, 2 and 3 are indicated by the number of LEDs that light up (excluding the light and the timer LEDs).

(In the 4-speed version, the pushbutton + blinks. The fourth speed remains on for a set duration of time. After 15 minutes, the motor returns to the third speed.)

Mode pushbutton

Function: it turns the hood motor on and off.

The function "desired speed" enables starting the motor at the speed that was selected before the hood was last turned off.

Optional: version with remote control (some versions only).

WARNING:

Install the hood away from sources of electromagnetic waves, as these could affect the correct operation of the electronic system.

Maximum operating distance: 5 metres. The maximum operating distance could be less than 5 metres in case of electromagnetic interference by other equipment.

Light pushbutton on remote control: light on/off.

  • and + pushbutton: increase/decrease speed (to start the motor, press either the + or the - pushbutton).

Timer pushbutton: see instructions below.

Instructions for changing the code (only in case of malfunctions caused by interferences):

Disconnect the hood from the power supply.

Remove the cover of the remote control, change the code with the levers.

Connect the hood to the power supply and make sure the lights and the motors are off.

Press the timer pushbutton for 2 seconds. When the red LED of the control panel lights up, press any of the buttons on the control panel.

Timer and 'filter clogged' alarm pushbutton

  • This function allows the automatic turning off of the hood after running for 15 minutes at the speed previously set (the pushbutton shows a flickering light).
  • After about 30 hours of running, the pushbutton indicates the need for washing the metal filters (the pushbutton shows a solid red light). To disable the alarm, press the pushbutton for a few seconds until the red light turns off. Then turn the hood off and on again to check that the alarm has disappeared.

FALMEC QUASAR MURALE - Timer and 'filter clogged' alarm pushbutton - 1

2. ELECTRONIC CONTROL PANEL (Quasar Glass)

Mode push-button

Function: it turns the hood motor on and off.

The function "desired speed" enables starting the motor at the speed that was selected before the hood was last turned off.

Push-button -

Press to reduce motor speed

Display

It indicates the current speed

Push-button +

Press to increase motor speed

Timer

This function allows the automatic turning off of the hood after running for 15 minutes at the speed previously set (the display shows a flickering light).

Light pushbutton

FALMEC QUASAR MURALE - Light pushbutton - 1

  • ON: light on
  • OFF: light off

Note: In order to maintain the correct functionality of the hood we recommend you to clean, periodically, the front part of the glass. To rinse and dry carefully use a soft cloth. Chemical and abrasive products are strictly forbidden.

FALMEC QUASAR MURALE - Light pushbutton - 2

FILTERS REMOVING AND REPLACING'S INSTRUCTIONS

1. METAL FILTERS

Open the panel (see fig. H3). Use handle A to remove the metal grease filter.

FALMEC QUASAR MURALE - METAL FILTERS - 1

2. CHARCOAL FILTERS

To replace the charcoal filters, proceed as follows: remove the metal filters as described above. The two filters located at the ends of the motor can now be easily accessed.

To install the new filters see picture.

To order new filters, use the coupon enclosed with this booklet or provided by the distributor.

FALMEC QUASAR MURALE - CHARCOAL FILTERS - 1

3. INSTRUCTION FOR REMOVABLE PANEL

Follow the instructions on fig.H3 to remove the panel.

FALMEC QUASAR MURALE - INSTRUCTION FOR REMOVABLE PANEL - 1

LIGHTING ASSEMBLY AND REPLACEMENT

SPOTLIGHT

How to replace a square halogen light:

a) Check that the equipment is disconnected from the power supply. b) Open the panel completely till 90° (see figure) pressing the PUSH button. c) Replace the lamp with a similar one (halogen, max 20 W, 12 Volt, G4 connection). d) Close the panel. If the panel does not close correctly, repeat the operation at point b.

FALMEC QUASAR MURALE - SPOTLIGHT - 1

FALMEC QUASAR MURALE - SPOTLIGHT - 2

FALMEC QUASAR MURALE - SPOTLIGHT - 3

MAINTENANCE AND CLEANING

Constant maintenance ensures the correct operation and efficiency of the appliance over time. Special attention should be paid to the metal grease-trapping filters and the charcoal filters. Frequent cleaning of the filters and their supports will ensure that fats and grease do not accumulate on the range hood, with the consequent risk of fire.

1. METAL GREASE-TRAPPING FILTERS

These trap the fat and grease particles suspended in the air, and therefore should be washed every month in hot water and detergent, without bending them. Wait until they are completely dry before repositioning them. To remove and replace these filters, see the instructions in point H1. This operation should be performed at regular intervals.

2. CHARCOAL FILTERS

These trap the odours present in the stream of air that passes through them. The air is purified by passing a number of times through the filters and being recirculated into the kitchen. The charcoal filters cannot be cleaned, and should be replaced on average every 3-4 months (according to use). To replace the charcoal filters, see the instructions in point H2.

3. CLEANING THE OUTSIDE OF THE APPLIANCE

The outside of the range hood should be cleaned using a damp cloth and neutral liquid detergent or denatured alcohol.

In case of fingerprint-less finish (fasteel) clean only with water and neutral soap using a soft cloth, rinse and wipe dry thoroughly. Do not use products that contain abrasive substances, rough cloths or cloths specifically designed for cleaning steel. Using abrasive substances or rough

cloths will inevitably damage the finish of steel. The steel surface will be irrevocably damaged if the instructions above are not complied with. Keep these instructions together with the instructions for use of your hood.

The manufacturer accepts no liability for any damage caused by non-compliance with the instructions above.

4. CLEANING THE INSIDE OF THE APPLIANCE

The electrical parts or parts of the motor assembly inside the range hood must not be cleaned using liquids or solvents.

FALMEC QUASAR MURALE - CLEANING THE INSIDE OF THE APPLIANCE - 1

Do not use abrasive products.

All the above operations must be performed after having disconnected the appliance from the mains power supply.

FALMEC QUASAR MURALE - CLEANING THE INSIDE OF THE APPLIANCE - 2

SAFETY WARNINGS

C E

FALMEC QUASAR MURALE - C E - 1

The electrical system features an earth connection in compliance with international safety standards; furthermore, it is compliant with the European standard for electromagnetic compatibility.

Do not connect the appliance to flues (from boilers, fireplaces, etc.). Make sure the mains voltage corresponds to the values on the rating plate located inside the range hood. The minimum safety distance between the cooktop and the range hood must be at least 65 cm.

Never cook on "open" flames under the range hood.

Check deep-fryers during use: superheated oil may be flammable.

  • Ensure there is adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels.
  • Do not flambé under the range hood.
  • The exhaust air must not be discharged into a flue which is used for exhausting fumes from appliances burning gas or other fuels.
  • Ensure that all regulations concerning the discharge of exhaust air have been fulfilled before you use the appliance.

FALMEC QUASAR MURALE - C E - 2

Before performing any cleaning or maintenance operations, disconnect the appliance by unplugging it or using the main switch. The manufacturer disclaims all liability for any damage that may be directly or indirectly caused to people, things and animals due to the failure to follow all the instructions provided in this booklet and above all the warnings relating to the installation, operation and maintenance of the appliance.

FALMEC QUASAR MURALE - C E - 3

WARRANTY

The new equipment is covered by warranty.

The warranty conditions are provided by the distributor.

FALMEC QUASAR MURALE - WARRANTY - 1

The manufacturer is not liable for any inaccuracies in this booklet resulting from printing or transcription errors. The manufacturer reserves the right to modify its products as it considers necessary or in the interests of the user, without compromising their essential safety and operating characteristics.

MOUNTING INSTRUCTIONS, RANGE HOODS WITH BOX

Step 1

  • Rest the support bar against the wall (A-Fig. O1) at a height from the cooktop determined by the sum of the distance X + 517.8 mm.
  • Check the horizontal alignment with a spirit level and mark the 2 holes to be drilled at the ends of the bar.
  • Drill the holes, insert 2 x 8 mm dia. screw anchors, and fasten the bar using the corresponding screws.

Step 2

  • Hook the range hood to the support bar (Fig. O2).
  • Adjust the alignment of the range hood using the screws on the brackets (Fig. O2). The top screw (B) adjusts the distance from the wall, the bottom screw (C) adjusts the height.

Step 3

  • To prevent the range hood from detaching due to pressure from below, fasten it to the wall using a screw anchor and screw, through the corresponding hole (Fig. O3) on the rotor box or inside the hood.
  • Insert the duct (E) on the ducting connection (D). Hood assembly instructions.

Step 4 (optional)

Place element (G) onto the chimney until it is fully inserted.

  • Fix the extension (H) to element (G), sliding it to the desired height.
  • Once having found the optimum position, rest the bracket (L) against the wall, check the horizontal alignment using a spirit level and mark the 2 holes to be drilled at the ends.
  • Drill the holes, insert 2 x 4 mm diameter screw anchors and fasten the bracket (L) using the corresponding screws.
  • Tighten the extension (H) to the bracket (L) using the screws (M).

FALMEC QUASAR MURALE - Step 4 (optional) - 1

NOTES

FALMEC QUASAR MURALE - NOTES - 1

1. ELECTRONIC CONTROL PANEL (Quasar Top)

Light button

1. ELECTRONIC CONTROL PANEL (Quasar Glass)

Mode button

SAFETY MEASURES

FALMEC QUASAR MURALE - SAFETY MEASURES - 1

It is very important that this instruction manual is kept together with the appliance for possible future consultation.

When selling the appliance or transferring it to another person, the manual must be attached to the appliance so that the new user is aware of how to use it and the corresponding safety measures to be observed.

This manual has been prepared for the safety of the user and those around them, so please read it carefully before installing and using the appliance.

Children and vulnerable people are not allowed to use the appliance without adequate supervision by responsible persons who can ensure safe use of the appliance.

The responsible person must ensure that children do not play with the device.

Installation work must be carried out by competent, qualified specialists in accordance with current standards.

Any necessary extraction or modification in the electrical block must be carried out only by competent personnel.

Changing or attempting to change the characteristics of the device is dangerous! In case of incorrect operation of the extractor, do not attempt to fix the malfunction yourself.

Repairs carried out by incompetent personnel may cause damage.

Extractor with exhaust to the outside

In this mode, fumes and steam from cooking are discharged outside through a pipe. The exhaust pipe, which protrudes from the upper part of the extractor, must be connected to a pipe that leads fumes and steam outside the room, see fig. In this mode, filters with activated carbon are removed, if they are installed; how to remove them, see paragraph. If the kitchen extractor is used simultaneously with other appliances operating on gas or other fuel, the room must have sufficient ventilation.

FALMEC QUASAR MURALE - Extractor with exhaust to the outside - 1

Extractor with air recirculation (with filters)

In this mode, air passes through filters with activated carbon, then is returned to the kitchen.

Make sure that the charcoal filters are installed on the motor, see fig. 6, otherwise install them as indicated in the instructions.

It is recommended to use the third speed for strong odors and large amounts of steam, the second speed for normal conditions, and the first speed for air purification at low electricity consumption.

It is recommended to turn on the extractor when you start cooking and leave it running until strong odors disappear.

FALMEC QUASAR MURALE - Extractor with air recirculation (with filters) - 1

OPERATION

1. ELECTRONIC CONTROL KEYS (Quasar Top)

Illuminated key

  • ON: illumination on (lamp indicator); OFF: illumination off;

Button -

When this button is pressed, the motor speed decreases.

Speeds 1, 2, 3 are indicated by the number of lit lamps, not counting the lamps for the timer illumination.

Button +

The illumination button is pressed: light on/off.

Button -/+: decrease/increase of speed (to start the motor, you can press either the + button or the - button).

Timer button: see below for instructions.

For installation/replacement of the lamp.

These rules must be kept together with the operating instructions for the extractor. The manufacturer accepts no claims in case of non-compliance with these rules.

4. CLEANING OF INTERNAL PARTS

Clean the electrical parts and parts inside the motor of the extractor with the help of liquid and solvent.

FALMEC QUASAR MURALE - CLEANING OF INTERNAL PARTS - 1

Do not use abrasive sponges.

Perform all operations, having previously disconnected the device from the electrical supply.

FALMEC QUASAR MURALE - CLEANING OF INTERNAL PARTS - 2

SAFETY PRECAUTIONS

FALMEC QUASAR MURALE - SAFETY PRECAUTIONS - 1

The electrical connection diagram for grounding is in accordance with international safety standards; moreover, it complies with European standards for protection against radio interference.

Do not connect the appliance to flues that remove smoke from fuel-burning appliances (boilers, fireplaces, etc.). Make sure that the mains voltage matches the value indicated on the data plate attached inside the hood.

For safety, the distance between the cooking surface and the hood must be at least 65 cm.

Never prepare food over an open flame under the hood. Watch the fryers: overheated oil may catch fire.

  • Make sure that the room has adequate ventilation if the hood is used together with other appliances that operate on gas or other fuels.
  • Do not leave open flames under the hood.
  • Do not connect the appliance to flues that remove smoke from fuel-burning appliances (boilers, fireplaces, etc.).
  • Make sure that all applicable regulations regarding the discharge of air from the room are observed before using the hood.

FALMEC QUASAR MURALE - SAFETY PRECAUTIONS - 2

Before performing any cleaning or maintenance operations, switch off the appliance, unplug it from the socket, or use the main switch. The manufacturer is not responsible for any damage, direct or indirect, to persons, objects, or pets resulting from failure to follow the instructions given in the user manual, especially regarding the rules for installation, use, and maintenance of the appliance.

FALMEC QUASAR MURALE - SAFETY PRECAUTIONS - 3

WARRANTY

The new appliance is covered by a legal warranty.

The warranty conditions are fully detailed on the last page of this publication.

FALMEC QUASAR MURALE - WARRANTY - 1

Installation instructions for the hood with recirculation kit

Step 1

- Place the flue support (A, fig. 1) at the desired height, which is the sum of the heights +517.8 mm. - Using a spirit level, check the horizontal position, and mark the drilling points at the edges of the support. - Drill the holes, insert 2 wall plugs of 8 mm diameter, and secure the support with screws.

Step 2

  • Insert the outlet device into the hole, see fig. 02.
  • Adjust the surface of the outlet device using the screws on the bracket, see fig. 02. The upper screw adjusts the distance from the wall, the lower one adjusts the vertical position.

Step 3

  • To avoid scratches caused by force applied from below, close the plug with the cap using the screwdriver through the special hole, see fig. 03, on the cap or screw the plug in.
  • Install the filter E on the supply pipe D.

Step 4

- Slide the tube fully in so that it is completely covered. - Insert the extension into the socket and adjust to the desired height. - Position the bracket L horizontally using a spirit level, and mark the holes through the 2 holes. - Drill the holes, insert 2 dowels with a diameter of 4 mm, and secure the bracket L with screws. - Screw the extension to the bracket L.

Note

Note

Note

Note

Note

Legislative Decree of 30/06/2003 n. 196 - art. 7

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : FALMEC

Model : QUASAR MURALE

Category : Wall hood