VFI 10000 CG PF1 - Alimentation sans coupure PowerWalker - Free user manual and instructions
Find the device manual for free VFI 10000 CG PF1 PowerWalker in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Uninterruptible Power Supply (UPS) |
| Model | VFI 10000 CG PF1 |
| Brand | PowerWalker |
| Power Capacity | 10000 VA / 9000 W |
| Topology | Online Double Conversion |
| Input Voltage Range | 160-275 VAC |
| Output Voltage | 220/230/240 VAC ± 1% |
| Output Frequency | 50/60 Hz ± 0.2% (auto-sensing) |
| Waveform | Pure Sine Wave |
| Battery Type | Sealed Lead-Acid, maintenance-free |
| Number of Batteries | 2 x 12V / 9Ah (or equivalent, internal) |
| Typical Backup Time (full load) | Approximately 5-10 minutes |
| Dimensions (W x D x H) | 437 x 650 x 88 mm (2U rackmount/tower) |
| Weight | Approximately 25 kg |
| Interfaces | USB, RS-232, SNMP slot (optional) |
| Input/Output Connections | Hardwired terminal block or IEC outlets |
| Protection Features | Overload, short circuit, surge, over-temperature, battery deep-discharge |
| Operating Temperature | 0-40°C |
| Humidity | 0-95% non-condensing |
| Noise Level | < 55 dBA at 1m |
| Maintenance | Periodic battery check and cleaning of vents |
Frequently Asked Questions - VFI 10000 CG PF1 PowerWalker
What is the typical backup runtime of the PowerWalker VFI 10000 CG PF1 at full load?
At full load (10000 VA), the backup time is approximately 5 to 10 minutes. Actual runtime may vary based on battery condition and load characteristics.
How do I replace the batteries in the UPS?
The UPS uses internal sealed lead-acid batteries. To replace, turn off the UPS, disconnect from mains, open the battery compartment, and disconnect the battery terminals. Replace with same type and rating. Always recycle old batteries properly. Consult manual for details.
Can the UPS communicate with a computer?
Yes, the UPS has USB and RS-232 ports for monitoring and shutdown software. An optional SNMP card can be installed for network management.
What is the input voltage range?
The UPS accepts an input voltage range of 160 to 275 VAC without using battery power, providing stable output.
Is this UPS suitable for use with sensitive equipment?
Yes, it produces a pure sine wave output with voltage regulation of ±1%, making it ideal for servers, medical equipment, and other sensitive loads.
What does 'VFI' stand for?
VFI stands for Voltage and Frequency Independent, meaning the UPS operates in online double-conversion mode, isolating the load from power disturbances.
How often should the batteries be replaced?
Battery lifespan is typically 3-5 years depending on usage and temperature. Regular tests are recommended to ensure capacity.
Can the UPS be mounted in a rack?
Yes, the VFI 10000 CG PF1 is designed as a 2U rackmount/tower convertible unit. Rackmount kit may be included or optional.
What alarms or indicators does the UPS have?
The UPS features LED indicators for power, battery, fault, and overload. Audible alarms sound for battery mode, low battery, and faults.
Is the UPS covered by warranty?
PowerWalker typically offers a 2-year warranty on the UPS and batteries. Extended warranty options may be available. Check your purchase documentation.